Data Delay MDU14-12.5M Quad, ecl-interfaced fixed delay line (series mdu14) Datasheet

MDU14
data 3 
delay
devices, inc.
QUAD, ECL-INTERFACED
FIXED DELAY LINE
(SERIES MDU14)
FEATURES
•
•
•
•
PACKAGES
Four independent delay lines
Fits 24-pin (400mil) DIP socket
Auto-insertable
Input & outputs fully 100K-ECL interfaced & buffered
MDU14-xx
DIP
MDU14-xxM Military DIP
GND
1
24
I1
O1
3
22
I2
O2
5
20
I3
GND
6
19
GND
GND
7
18
VEE
O3
9
16
I4
O4
11
13
GND
GND
N/C
O1
N/C
O2
GND
GND
N/C
O3
N/C
O4
N/C
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
DDU14-xxC4
DDU14-xxMC4
I1
N/C
I2
N/C
I3
GND
VEE
N/C
I4
N/C
N/C
GND
SMD
Mil SMD
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The MDU14-series device is a 4-in-1 digitally buffered delay line. The
signal inputs (I1-I4) are reproduced at the outputs (O1-O4), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
I1-I4
O1-O4
VEE
GND
SERIES SPECIFICATIONS
•
•
•
•
•
•
Signal Inputs
Signal Outputs
-5 Volts
Ground
DASH NUMBER SPECIFICATIONS
Minimum input pulse width: 40% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 500mw typical (no load)
Operating temperature: 0° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
O1
O2
O3
O4
100%
100%
100%
100%
Part
Number
MDU14-2
MDU14-2.5
MDU14-3
MDU14-4
MDU14-5
MDU14-6
MDU14-7
MDU14-8
MDU14-9
MDU14-10
MDU14-12.5
MDU14-15
MDU14-20
MDU14-25
Total
Delay (ns)
2.0 ± 1.0
2.5 ± 1.0
3.0 ± 1.0
4.0 ± 1.0
5.0 ± 1.0
6.0 ± 1.0
7.0 ± 1.0
8.0 ± 1.0
9.0 ± 1.0
10.0 ± 1.0
12.5 ± 1.0
15.0 ± 1.0
20.0 ± 1.0
25.0 ± 1.2
NOTE: Any dash number between 2 and 25
not shown is also available.
VCC
I1
I2
I3
I4
GND
Functional block diagram
 1997 Data Delay Devices
Doc #97042
12/15/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
MDU14
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The MDU14 tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 40% of the total delay and periods as
small as 80% of the total delay (for a symmetric
input), the delays may deviate from their values at
low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The MDU14 relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VEE
VIN
TSTRG
TLEAD
MIN
-7.0
VEE - 0.3
-55
MAX
0.3
0.3
150
300
UNITS
V
V
C
C
NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 85C)
PARAMETER
High Level Output Voltage
Low Level Output Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
Doc #97042
12/15/97
SYMBOL
VOH
VOL
VIH
VIL
IIH
IIL
MIN
-1.025
-1.810
-1.165
-1.810
TYP
MAX
-0.880
-1.620
-0.880
-1.475
340
0.5
UNITS
V
V
V
V
µA
µA
NOTES
VIH = MAX,50Ω to -2V
VIL = MIN, 50Ω to -2V
VIH = MAX
VIL = MIN
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2
MDU14
PACKAGE DIMENSIONS
24
22
20 19 18
16
13
.530
MAX.
1
3
5
6
7
9
11
1.300 MAX.
.015 .300
TYP. MAX.
.130
±.030
.018 TYP.
.012 TYP.
.100 TYP.
.400
TYP.
1.100 TYP.
MDU14-xx (Commercial DIP)
MDU14-xxM (Military DIP)
.020 TYP.
.040 TYP.
.010±.002
24 23 22 21 20 19 18 17 16 15 14 13
.882
±.005
.710 .590
±.005 MAX.
1
2
3
4
5
6
7
8
.090
9
.007
±.005
10 11 12
.100
1.100
1.280±.020
.280
MAX.
.050
±.010
MDU14-xxC4 (Commercial SMD)
MDU14-xxMC4 (Military SMD)
Doc #97042
12/15/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
MDU14
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
o
o
Ambient Temperature: 25 C ± 3 C
Supply Voltage (Vcc): -5.0V ± 0.1V
Input Pulse:
Standard 10KH ECL
levels
Source Impedance:
50Ω Max.
Rise/Fall Time:
2.0 ns Max. (measured
between 20% and 80%)
Pulse Width:
PWIN = 1.5 x Total Delay
Period:
PERIN = 10 x Total Delay
OUTPUT:
Load:
Cload:
Threshold:
50Ω to -2V
5pf ± 10%
(VOH + VOL) / 2
(Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
REF
PULSE
GENERATOR
OUT
I1
O1
IN
TRIG
I2
O2
TRIG
I3
DEVICE UNDER
TEST (DUT)
I4
OSCILLOSCOPE
O3
O4
Test Setup
PERIN
PWIN
TRISE
INPUT
SIGNAL
TFALL
VIH
80%
50%
20%
80%
50%
20%
TRISE
OUTPUT
SIGNAL
VIL
TFALL
VOH
50%
50%
VOL
Timing Diagram For Testing