XP Power JPP130PM02 Dc-dc power supply Datasheet

AC-DC
130 Watts
xppower.com
JPP130 Series
•
High Power Density
•
Small Footprint
•
Up to Five DC Outputs
•
Wide Adjustment on Two Outputs
•
Short Circuit Protection with Auto Recovery
•
Power Fail Signal
•
Active Power Factor Correction
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
General
•
•
•
•
•
90-264 VAC
47-63 Hz
2.10 A at 115 VAC, 1.10 A at 230 VAC
35 A at 115 VAC, 70 A at 230 VAC
0.98 typical
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Transient Response
•
•
•
•
•
•
•
•
•
See table
User adjustable (see note 3)
2% except V2: 3%
See note 4
2 s max
12 ms max
15 ms min
±0.5% max
4% max. deviation, 500 µs recovery time
for a 25% load change
Ripple & Noise
• 65 mV for V1, 1% pk-pk on all other
outputs, 20 MHz BW
Overvoltage Protection • V1, V2 & V5 only: 112-132% of nominal
Temperature
• 0.04% / ºC
Coefficient
Remote Sense
• On 3.3 V output only: Compensates for
up to 0.5 V drop
Efficiency
Isolation
Power Density
Signals
MTBF
• 75% typical
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 7.2 W/In3
• PFD = TTL Level (see note 5)
• 200 kHrs per MIL-STD-217F
Environmental
Operating Temperature • -10 ºC to +60 ºC, derate from 100% load
at +40 ºC to 50% load at +60 ºC
Cooling
• 10 CFM
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature
• -40 ºC to + 85 ºC
Shock
• 20 G on 3 axis, 3 times each
Vibration
• 10-55 Hz, 0.15 at 1 octave/min for
30 mins on each 3 axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 FCC part 15 and VCCI level B
conducted and level A radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
• UL60950, CSA C22.2 No. 60950,
EN60950, CE Mark LVD
Output
V1(3, 4)
+5.1 V/12.0 A
+5.1 V/12.0 A
+5.1 V/12.0 A
+5.1 V/12.0 A
Output
V2
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
+12.0
+15.0
+24.0
V/6.0
V/4.8
V/3.0
V/6.0
V/4.8
V/3.0
V/6.0
V/4.8
V/3.0
V/6.0
V/4.8
V/3.0
V/6.0
V/4.8
V/3.0
V/6.0
V/4.8
V/3.0
V/6.0
V/4.8
V/3.0
V/6.0
V/4.8
V/3.0
Output
V3(3)
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Output
V4(3)
Output
V5(2, 3)
Model
Number
JPP130PD02
JPP130PD03
JPP130PD04
JPP130PT01
JPP130PT02
JPP130PT03
JPP130PT04
JPP130PT05
JPP130PT06
JPP130PT07
JPP130PT08
JPP130PT09
JPP130PQ01
JPP130PQ02
JPP130PQ03
JPP130PQ04
JPP130PQ05
JPP130PQ06
JPP130PQ07
JPP130PQ08
JPP130PQ09
JPP130PM01
JPP130PM02
JPP130PM03
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0
+5.0
+5.0
+5.0
+5.0
+5.0
to
to
to
to
to
to
24.0
24.0
24.0
24.0
24.0
24.0
V/1.0
V/1.0
V/1.0
V/1.0
V/1.0
V/1.0
A
A
A
A
A
A
-5.0
-5.0
-5.0
-5.0
-5.0
-5.0
-5.0
-5.0
-5.0
to
to
to
to
to
to
to
to
to
-24.0
-24.0
-24.0
-24.0
-24.0
-24.0
-24.0
-24.0
-24.0
V/1.0
V/1.0
V/1.0
V/1.0
V/1.0
V/1.0
V/1.0
V/1.0
V/1.0
A
A
A
A
A
A
A
A
A
3.3
3.3
3.3
3.3
3.3
3.3
V/12.0
V/12.0
V/12.0
V/12.0
V/12.0
V/12.0
A
A
A
A
A
A
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
Notes
1. Minimum 10 CFM required for 130 W operation.
2. V1 and V5 combined output power not to exceed 65 W; V2, V3 and V4 combined output power not to exceed 65 W; V3 and V4 combined output power
not to exceed 30 W.
3. Adjustable range: V1 and V5 are adjustable ±10%, V3 and V4 can be trimmed 5-24 VDC and are factory-set to 12 VDC nominal.
Accessible trim pots are assigned as VR1 for V1, VR2 for V5, VR3 for V3, VR4 for V4 and V2 is fixed.
VR3 and VR4 trim pots are SMD types are located underneath PCB.
4. Minimum load of 0.8 A is required on V1 to regulate V5 where fitted.
5. PFD = TTL low gives warning of at least 10 ms before V1 output drops below 95% of nominal. This signal also provides a minimum of 100 ms delay after
V1 is within regulation.
Mechanical Details
All dimensions are in inches (mm), tolerance: ±0.02 (±0.5) max
Weight: 0.71 lbs (320 g)
0.225 (5.72)
0.16 (4.0) Dia Mounting Hole (4 PLS)
6
DIRECTION
OF AIR FLOW
P3
N
L
P1
P4
1
4
2.55 (64.8)
3.00 (76.2)
P2
1
2
1
PIN CONNECTIONS
Pin
P1
P2
P3
1
Live
V1
-Sense (V5)
P4(1)
V5
2
Neutral
Com
+Sense (V5)
Com
3
-
Com
PFD signal
-
4
-
V3 or N/C
Com
-
5
-
V4 or N/C
-
-
6
-
V2 or N/C
-
-
Note:
1. P4 only applies to models which have an Output V5 in the
Models and Rating table.
Derating Curve
4.55 (115.6)
5.00 (127.0)
130
1.04 (26.4)
VR2 VR1
0.10 (2.54)
P2 & P4 Connectors: Can accept 18-12 AWG electric wires.
P1 Mating Connector: Molex 09-50-3031 and 2878 series crimp terminals or equivalent.
P3 Mating Connector: Molex 22-01-1043 and 40445 series crimp terminals or equivalent.
Output Power (W)
1.20 (30.48)
10 CFM
Forced-air Cooling
90
65 W
5 CFM
Forced-air Cooling
45 W
Convection Cooling
10 W
20
0.06 (1.60)
0
-10
0
10 20 30 40 50
Ambient Temperature (˚C)
60
04/04/05
AC-DC
JPP130
Models and Ratings
Similar pages