ETC2 OM5008ST Hermetic jedec to-257aa high efficiency, soft recovery rectifier Datasheet

OM5008ST
OM5009ST
HERMETIC JEDEC TO-257AA HIGH EFFICIENCY,
SOFT RECOVERY RECTIFIER
14 Amp, 400 & 600 Volts, 35 nsec trr
FEATURES
•
•
•
•
•
•
•
Small Size
Ultra Fast Recovery
Soft Recovery Behavior
Extremely Low Losses At High Switching Speeds
Low IRM Rating
Hermetic And Isolated Package
Available Screened To MIL-S-19500, TX, TXV And S Levels
DESCRIPTION
This soft recovery, high speed rectifier is ideally suited for high performance in high
voltage switching applications. The performance of this rectifier minimizes losses in
power conversion and motor control circuits complementing the switching
characteristics of power MOSFETs, IGBTs, and bipolar transistors.
ABSOLUTE MAXIMUM RATINGS TC = 25°C
Peak Inverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 & 600 V
Maximum Average D.C. Output Current @ TC = 100°C . . . . . . . . . . . . . . . . . . . . . . . . . . 14 A
Surge Current (Non-Repetitve 8.3 nsec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 A
Thermal Resistance, Junction-To-Case. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5° C/W
Operating and Storage Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +150°C
3.2
MECHANICAL OUTLINE
PIN CONNECTION
.200
.190
.420
.410
.045
.035
.665
.645
.150
.140
.537
.527
.430
.410
.038 MAX.
.750
.500
.045
.035
4 11 R0
.200 TYP.
.005
.120 TYP.
3.2 - 37
Cathode
Anode
OM5008ST - OM5009ST
ELECTRICAL CHARACTERISTICS
Type
Maximum
Forward Voltage
@ 14 A
Tj = 25° C
Tj = 150° C
PIV
OM5008ST
400
OM5009ST
600
1.75 V
Maximum
Reverse Current
@ .8x PIV
Tj = 25° C
Tj = 125° C
1.65 V
100 µA
Maximum
Reverse
Recovery
Time
3.0 mA
35
TURN-OFF CHARACTERISTICS
Symbols
Test Conditions
Min.
Typ.
Max.
Units
-
-
35
ns
-
4
6
A
IF = 0.5 A; IR = 1 A; TJ = 25°C
Trr
IF = 1 A; di/dt = -15 A/µs; VR = 30 V; TJ = 25°C
VR = 350 V; IF = 12 A
IRM
L .05 µH; TJ = 100°C; diF/dt = -100 A/µs
DEFINITION OF TURN-OFF CHARACTERISTICS
i,v
i
diF
dt
IF
trr
tfRM
O
Qrr
IRM
TYPICAL REVERSE CURRENT
100
IR = Reverse Current, mA
3.2
50
10
TJ = 150°C
5
TJ = 125°C
TJ = 25°C
1
20
40
60
% of VRRM
80
100
tf
t
0.25 - VRM
diF
dt
0.9 - IRM
VR
TYPICAL FORWARD VOLTAGE
IF = Instantaneous Forward Current (Amps)
V
100
50
TJ = 125°C
30
20
10
TJ = 25°C
5
3
2
1
1.1
1.3
1.5
1.7
VF = Instantaneous Voltage (Volts)