ON NCP1253 Current-mode pwm current-mode pwm power supply Datasheet

NCP1253
Current-Mode PWM
Controller for Off-line
Power Supplies
The NCP1253 is a highly integrated PWM controller capable of
delivering a rugged and high performance offline power supply in a
tiny TSOP−6 package. With a supply range up to 28 V, the controller
hosts a jittered 65 kHz or 100 kHz switching circuitry operated in peak
current mode control. When the power on the secondary side starts to
decrease, the controller automatically folds back its switching
frequency down to a minimum level of 26 kHz. As the power further
goes down, the part enters skip cycle while limiting the peak current.
To avoid sub harmonic oscillations in CCM operation, adjustable
slope compensation is available via the series inclusion of a simple
resistor in the current sense signal.
Besides the auto−recovery timer−based short−circuit protection, an
Over Voltage Protection on the VCC pin protects the whole circuitry in
case of optocoupler destruction or adverse open loop operation.
http://onsemi.com
1
TSOP−6
CASE 318G
STYLE 13
MARKING DIAGRAM
Features
53xAYWG
G
• Fixed−Frequency 65 kHz or 100 kHz Current−Mode Control
Operation
1
• Frequency Foldback Down to 26 kHz and Skip−Cycle in Light Load
•
•
•
•
•
•
•
•
Conditions
Adjustable Ramp Compensation
Internally Fixed 4 ms soft−start
Timer−based Auto−Recovery or Latched Short−Circuit Protection
Frequency Jittering in Normal and Frequency Foldback Modes
Latched OVP on VCC
Up to 28 V VCC Operation
Extremely Low No−load Standby Power
These are Pb−Free Devices
Typical Applications
• Ac−dc Converters for TVs, Set−top Boxes and Printers
• Offline Adapters for Notebooks and Netbooks
53
x
A
Y
W
G
= Specific Device Code
= A, 2, C, or D
= Assembly Location
= Year
= Work Week
= Pb−Free Package
(Note: Microdot may be in either location)
PIN CONNECTIONS
GND
1
6
DRV
FB
2
5
VCC
NC
3
4
CS
(Top View)
ORDERING INFORMATION
See detailed ordering and shipping information in the package
dimensions section on page 2 of this data sheet.
© Semiconductor Components Industries, LLC, 2012
January, 2012 − Rev. 0
1
Publication Order Number:
NCP1253/D
NCP1253
Vbulk
.
Vout
.
.
NCP1253
1
6
2
5
3
4
ramp
comp.
Figure 1. Typical Application Schematic
PIN FUNCTION DESCRIPTION
Pin No.
Pin Name
Function
1
GND
−
Description
2
FB
Feedback pin
3
NC
Non−connected pin
4
CS
Current sense + ramp compensation
5
VCC
Supplies the controller – protects the IC
6
DRV
Driver output
The controller ground.
Hooking an optocoupler collector to this pin will allow
regulation.
The pin is electrically inert and can be grounded if necessary
This pin monitors the primary peak current but also offers a
means to introduce slope compensation.
This pin is connected to an external auxiliary voltage. An OVP
comparator monitors this pin and offers a means to latch the
converter in fault conditions.
The driver’s output to an external MOSFET gate.
OPTIONS
Controller
Frequency
OCP Latched
OCP Auto−Recovery
NCP1253ASN65T1G
65 kHz
Yes
No
NCP1253BSN65T1G
65 kHz
No
Yes
NCP1253ASN100T1G
100 kHz
Yes
No
NCP1253BSN100T1G
100 kHz
No
Yes
ORDERING INFORMATION
Package
Marking
OCP
Protection
Switching
Frequency
(kHz)
NCP1253ASN65T1G
53A
Latch
65
NCP1253BSN65T1G
532
Auto
Recovery
65
NCP1253ASN100T1G
53C
Latch
100
NCP1253BSN100T1G
53D
Auto
Recovery
100
Device
Package
Shipping†
TSOP−6
(Pb−Free)
3000 / Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
http://onsemi.com
2
NCP1253
IpFlag
BO
Vcc logic
management
and fault timer
UVLO
vdd
20us time
constant
VOVP
power
on reset
S
Q
Q
vdd
Rlim
Vcc
R
Power on
65 kHz
100 kHz
clock
reset
Frequency
modulation
Clamp
S
Q
Q
R
Frequency
foldback
Drv
Vfold
Vskip
Rramp
VDD
4 ms
SS
The soft−start is activated during:
Vlimit
IpFlag
− the startup sequence
− the auto−recovery burst mode
RFB
/ 4.2
VFB < 1.05 V ? setpoint = 250 mV
FB
CS
LEB
250 mV
peak current
freeze
GND
Figure 2. Internal Circuit Architecture
http://onsemi.com
3
NCP1253
MAXIMUM RATINGS TABLE
Symbol
VCC
Rating
Power Supply voltage, Vcc pin, continuous voltage
Maximum voltage on low power pins CS, and FB
Value
Unit
28
V
−0.3 to 10
V
RqJ−A
Thermal Resistance Junction−to−Air
360
°C/W
TJ,max
Maximum Junction Temperature
150
°C
−60 to +150
°C
2
kV
200
V
Storage Temperature Range
ESD Capability, Human Body Model, all pins
ESD Capability, Machine Model
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. This device series contains ESD protection and exceeds the following tests: Human Body Model 2000 V per Mil−Std−883, Method 3015.
Machine Model Method 200 V.
2. This device contains latch−up protection and exceeds 100 mA per JEDEC Standard JESD78.
ELECTRICAL CHARACTERISTICS
(For typical values TJ = 25°C, for min/max values TJ = −40°C to +125°C, Max TJ = 150°C, VCC = 12 V unless otherwise noted)
Rating
Pin
Min
Typ
Max
Unit
VCC increasing level at which driving pulses are authorized
5
16
18
20
V
VCC(min)
VCC decreasing level at which driving pulses are stopped
5
8.2
8.8
9.4
V
VCCHYST
Hysteresis VCCON−VCC(min)
5
6
−
−
V
Symbol
VCCON
VZENER
Clamped VCC when latched off @ ICC = 500 mA
5
−
7
−
V
ICC1
Start−up current
5
−
−
15
mA
ICC2
Internal IC consumption with IFB = 50 mA, FSW = 65 kHz and CL = 0
5
−
1.4
2.2
mA
ICC3
Internal IC consumption with IFB = 50 mA, FSW = 65 kHz and CL = 1 nF
5
−
2.1
3.0
mA
ICC2
Internal IC consumption with IFB = 50 mA, FSW = 100 kHz and CL = 0
5
−
1.7
2.5
mA
ICC3
Internal IC consumption with IFB = 50 mA, FSW = 100 kHz and CL = 1 nF
5
−
3.1
4.0
mA
ICCstby
Internal IC consumption while in skip mode (VCC = 12 V, driving a typical
6 A/600 V MOSFET)
5
ICCLATCH
Current flowing into VCC pin that keeps the controller latched –
TJ = 0 to 125°C
5
32
mA
ICCLATCH
Current flowing into VCC pin that keeps the controller latched –
TJ = −40°C to 125°C
5
40
mA
550
mA
DRIVE OUTPUT
Tr
Output voltage rise−time @ CL = 1 nF, 10−90% of output signal
6
−
40
−
ns
Tf
Output voltage fall−time @ CL = 1 nF, 10−90% of output signal
6
−
30
−
ns
ROH
Source resistance
6
−
13
−
W
ROL
Sink resistance
6
−
6
−
Peak source current, VGS = 0 V (Note 3)
6
300
mA
Peak sink current, VGS = 12 V (Note 3)
6
500
mA
VDRVlow
DRV pin level at VCC close to VCC(min) with a 33 kW resistor to GND
6
8
−
−
V
VDRVhigh
DRV pin level at VCC= 28 V – DRV unloaded
6
10
12
14
V
Isource
Isink
W
3. Guaranteed by design
CURRENT COMPARATOR
IIB
Input Bias Current @ 0.8 V input level on pin 4
4
VLimit1
Maximum internal current setpoint – TJ = 25 °C
4
0.744
0.8
0.856
V
VLimit2
Maximum internal current setpoint – TJ = −40° to 125 °C
4
0.72
0.8
0.88
V
http://onsemi.com
4
0.02
mA
NCP1253
ELECTRICAL CHARACTERISTICS
(For typical values TJ = 25°C, for min/max values TJ = −40°C to +125°C, Max TJ = 150°C, VCC = 12 V unless otherwise noted)
Symbol
Rating
Pin
Min
Typ
Max
Unit
Default internal voltage set point for frequency foldback trip point – 45% of
Vlimit
4
357
mV
Internal peak current setpoint freeze (≈31% of Vlimit)
4
250
mV
TDEL
Propagation delay from current detection to gate off−state
4
100
TLEB
Leading Edge Blanking Duration
4
300
ns
TSS
Internal soft−start duration activated upon startup, auto−recovery
−
4
ms
CURRENT COMPARATOR
Vfold
Vfreeze
150
ns
INTERNAL OSCILLATOR
fOSC
Oscillation frequency (65 kHz version)
−
61
65
71
kHz
fOSC
Oscillation frequency (100 kHz version)
−
92
100
108
kHz
Dmax
Maximum duty−ratio
−
76
80
84
%
fjitter
Frequency jittering in percentage of fOSC
−
±5
%
fswing
Swing frequency
−
240
Hz
Feedback Section
Rup
Internal pull−up resistor
2
20
kW
Req
Equivalent ac resistor from FB to GND
2
16
kW
Iratio
Pin 2 to current setpoint division ratio
−
4.2
Feedback voltage below which the peak current is frozen
2
1.05
V
1.5
V
Vfreeze(FB)
FREQUENCY FOLDBACK
Vfold
Frequency foldback level on the feedback pin – ≈45% of maximum peak
current
−
Ftrans
Transition frequency below which skip−cycle occurs
−
Vfold,end
End of frequency foldback feedback level, Fsw = Fmin
Vskip
Skip
hysteresis
22
26
30
kHz
350
mV
Skip−cycle level voltage on the feedback pin
−
300
mV
Hysteresis on the skip comparator
−
30
mV
INTERNAL SLOPE COMPENSATION
Vramp
Internal ramp level @ 25°C (Note 4)
4
2.5
V
Rramp
Internal ramp resistance to CS pin
4
20
kW
4. A 1 MW resistor is connected from pin 4 to the ground for the measurement.
PROTECTIONS
VOVP
Latched Overvoltage Protection on the VCC rail
5
TOVPdel
Delay before OVP confirmation on the VCC rail
5
Internal auto−recovery fault timer duration
−
Timer
http://onsemi.com
5
24
25.5
100
130
27
V
160
ms
20
ms
NCP1253
TYPICAL CHARACTERISTICS
100 kHz
65 kHz
Figure 3. Dmax vs. Junction Temperature
Figure 4. Fosc vs. Junction Temperature
Figure 5. Ftrans vs. Junction Temperature
Figure 6. ICC1 vs. Junction Temperature
100 kHz
100 kHz
65 kHz
65 kHz
Figure 7. ICC2 vs. Junction Temperature
Figure 8. ICC3 vs. Junction Temperature
http://onsemi.com
6
NCP1253
TYPICAL CHARACTERISTICS
Figure 9. VLimit vs. Junction
Temperature
Figure 10. VCC(ON) vs. Junction
Temperature
Figure 11. VCC(min) vs. Junction
Temperature
Figure 12. VCC(Hyst) vs. Junction
Temperature
Figure 13. ICCLatch vs. Junction
Temperature
Figure 14. TLEB vs. Junction
Temperature
http://onsemi.com
7
NCP1253
TYPICAL CHARACTERISTICS
Figure 15. TDEL vs. Junction
Temperature
Figure 16. TSS vs. Junction Temperature
Figure 17. Vfold vs. Junction
Temperature
Figure 18. Vfold(FB) vs. Junction
Temperature
Figure 19. Vfold_end vs. Junction
Temperature
Figure 20. Vskip vs. Junction
Temperature
http://onsemi.com
8
NCP1253
Figure 21. Vfreeze vs. Junction
Temperature
Figure 22. Vfreeze(FB) vs. Junction
Temperature
Figure 23. Timer vs. Junction
Temperature
Figure 24. VOVP vs. Junction
Temperature
http://onsemi.com
9
NCP1253
APPLICATION INFORMATION
Introduction
The NCP1253 implements a standard current mode
architecture where the switch−off event is dictated by the
peak current setpoint. This component represents the ideal
candidate where low part−count and cost effectiveness are
the key parameters, particularly in low−cost ac−dc adapters,
open−frame power supplies etc. Capitalizing on the
NCP1200 series success, the NCP1253 brings all the
necessary components normally needed in today modern
power supply designs, bringing several enhancements such
as a VCC OVP or an adjustable slope compensation signal.
• Current−mode operation with internal ramp
compensation: implementing peak current mode control
at a fixed 65 kHz or 100 kHz frequency, the NCP1253
offers an internal ramp compensation signal that can
easily by summed up to the sensed current. Sub harmonic
oscillations can thus be compensated via the inclusion of
a simple resistor in series with the current−sense
information.
• Low startup current: reaching a low no−load standby
power always represents a difficult exercise when the
controller draws a significant amount of current during
start−up. Thanks to its proprietary architecture, the
NCP1253 is guaranteed to draw less than 15 mA
maximum, easing the design of low standby power
adapters.
• EMI jittering: an internal low−frequency modulation
signal varies the pace at which the oscillator frequency is
modulated. This helps spreading out energy in conducted
noise analysis. To improve the EMI signature at low
power levels, the jittering will not be disabled in
frequency foldback mode (light load conditions).
• Frequency foldback capability: a continuous flow of
pulses is not compatible with no−load/light−load standby
power requirements. To excel in this domain, the
controller observes the feedback pin and when it reaches
a level of 1.5 V, the oscillator then starts to reduce its
switching frequency as the feedback level continues to
decrease. When the feedback pin reaches 1.05 V, the peak
current setpoint is internally frozen and the frequency
continues to decrease. It can go down to 26 kHz (typical)
reached for a feedback level of 350 mV roughly. At this
•
•
•
point, if the power continues to drop, the controller enters
classical skip−cycle mode.
Internal soft−start: a soft−start precludes the main power
switch from being stressed upon start−up. In this
controller, the soft−start is internally fixed to 4 ms.
Soft−start is activated when a new startup sequence
occurs or during an auto−recovery hiccup.
Latched OVP on Vcc: it is sometimes interesting to
implement a circuit protection by sensing the VCC level.
This is what NCP1253 does by monitoring its VCC pin.
When the voltage on this pin exceeds 25.5 V typical, the
pulses are immediately stopped and the part latches off.
When the user cycles the VCC down or the converter
recovers from a brown−out event, the circuit is reset and
the part enters a new start−up sequence.
Short−circuit protection: short−circuit and especially
over−load protections are difficult to implement when a
strong leakage inductance between auxiliary and power
windings affects the transformer (the aux winding level
does not properly collapse in presence of an output short).
Here, every time the internal 0.8 V maximum peak
current limit is activated, an error flag is asserted and a
time period starts, thanks to an internal timer. When the
fault is validated, all pulses are stopped and the controller
enters an auto−recovery burst mode, with a soft−start
sequence at the beginning of each cycle. As soon as the
fault disappears, the SMPS resumes operation. Please
note that some version offers an auto−recovery mode as
we just described, some do not and latch off in case of a
short circuit.
Start−up Sequence
The NCP1253 start−up voltage is made purposely high to
permit large energy storage in a small VCC capacitor value.
This helps to operate with a small start−up current which,
together with a small Vcc capacitor, will not hamper the
start−up time. To further reduce the standby power, the
start−up current of the controller is extremely low, below
15 mA. The start−up resistor can therefore be connected to
the bulk capacitor or directly to the mains input voltage if
you wish to save a few more mW.
http://onsemi.com
10
NCP1253
R3
100k
R2
100k
D2
1N4007
D1
1N4007
R1
200k
Cbulk
22uF
input
mains
D6
1N4148
D5
1N4935
Vcc
D4
1N4007
D3
1N4007
C1
4.7uF
aux.
C3
47uF
Figure 25. The Startup Resistor Can Be Connected to the Input Mains for Further Power Dissipation Reduction
The first step starts with the calculation of the needed VCC
capacitor which will supply the controller until the auxiliary
winding takes over. Experience shows that this time t1 can
be between 5 and 20 ms. Considering that we need at least
an energy reservoir for a t1 time of 10 ms, the Vcc capacitor
must be larger than:
CV CC w
I CCt 1
VCC on * VCC min
w
3m
10m
9
V ac,rmsǸ2
I CVCC,min +
VCC OnC VCC
2.5
w
18
4.7m
V ac,rmsǸ2
(eq. 1)
R start−up v
w 3.3 mF
2.5
w 34 mA
* VCC on
(eq. 3)
R start−up
To make sure this current is always greater than 49 mA, the
maximum value for Rstart−up can be extracted:
p
* VCC on
I CVCC,min
85
v
1.414
p
* 18
49m
(eq. 4)
v 413 kW
This calculation is purely theoretical, considering a
constant charging current. In reality, the take over time can
be shorter (or longer!) and it can lead to a reduction of the
Vcc capacitor. This brings a decrease in the charging current
and an increase of the start−up resistor, for the benefit of
standby power. Laboratory experiments on the prototype are
thus mandatory to fine tune the converter. If we chose the
400k resistor as suggested by Equation 4, the dissipated
power at high line amounts to:
Let us select a 4.7 mF capacitor at first and experiments in
the laboratory will let us know if we were too optimistic for
t1. The VCC capacitor being known, we can now evaluate the
charging current we need to bring the Vcc voltage from 0 to
the VCCon of the IC, 18 V typical. This current has to be
selected to ensure a start−up at the lowest mains (85 V rms)
to be less than 3 s (2.5 s for design margin):
I charge w
p
(eq. 2)
If we account for the 15 mA that will flow inside the
controller, then the total charging current delivered by the
start−up resistor must be 49 mA. If we connect the start−up
network to the mains (half−wave connection then), we know
that the average current flowing into this start−up resistor
will be the smallest when VCC reaches the VCCon of the
controller:
If we account for the 15 mA that will flow inside the
controller, then the total charging current delivered by the
start−up resistor must be 49 mA. If we connect the start−up
network to the mains (half−wave connection then), we know
that the average current flowing into this start−up resistor
will be the smallest when VCC reaches the VCCon of the
controller:
P Rstart,max +
V ac,peak
2
4R start−up
+
ǒ320
4
Ǹ2Ǔ
400k
2
+
105k
1.6Meg
(eq. 5)
+ 66 mW
Now that the first VCC capacitor has been selected, we
must ensure that the self−supply does not disappear when in
no−load conditions. In this mode, the skip−cycle can be so
deep that refreshing pulses are likely to be widely spaced,
inducing a large ripple on the VCC capacitor. If this ripple is
too large, chances exist to touch the VCCmin and reset the
controller into a new start−up sequence. A solution is to
grow this capacitor but it will obviously be detrimental to the
start−up time. The option offered in Figure 25 elegantly
http://onsemi.com
11
NCP1253
solves this potential issue by adding an extra capacitor on the
auxiliary winding. However, this component is separated
from the VCC pin via a simple diode. You therefore have the
ability to grow this capacitor as you need to ensure the
self−supply of the controller without jeopardizing the
start−up time and standby power.
In this case, the current is no longer made of 5 ms “holes”
and the part can be maintained at a low input voltage.
Experiments show that these 2 MW resistor help to maintain
the latch down to less than 50 Vrms, giving an excellent
design margin. Standby power with this approach was also
improved compared to Figure 25 solution. Please note that
these resistors also ensure the discharge of the X2−capacitor
up to a 0.47 mF type.
The de−latch of the SCR occurs when the injected current
in the VCC pin falls below the minimum stated in the
data−sheet (32 mA at room temp).
Triggering the SCR
The latched−state of the NCP1253 is maintained via an
internal thyristor (SCR). When the voltage on the Vcc pin
exceeds the internal latch voltage, the SCR is fired and
immediately stops the output pulses. When this happens, all
pulses are stopped and VCC is discharged to a fix level of 7 V
typically: the circuit is latched and the converter no longer
delivers pulses. To maintain the latched−state, a permanent
current must be injected in the part. If too low of a current,
the part de−latches and the converter resumes operation.
This current is characterized to 32 mA as a minimum but we
recommend including a design margin and select a value
around 60 mA. The test is to latch the part and reduce the
input voltage until it de−latches. If you de−latch at Vin =
70 Vrms for a minimum voltage of 85 Vrms, you are fine. If
it precociously recovers, you will have to increase the
start−up current, unfortunately to the detriment of standby
power.
The most sensitive configuration is actually that of the
half−wave connection proposed in Figure 25. As the current
disappears 5 ms for a 10 ms period (50 Hz input source), the
latch can potentially open at low line. If you really reduce the
start−up current for a low standby power design, you must
ensure enough current in the SCR in case of a faulty event.
An alternate connection to the above is shown below
(Figure 26):
1 Meg
N
L1
Frequency Foldback
The reduction of no−load standby power associated with
the need for improving the efficiency, requires a change in
the traditional fixed−frequency type of operation. This
controller implements a switching frequency foldback when
the feedback voltage passes below a certain level, Vfold, set
around 1.5 V. At this point, the oscillator enters frequency
foldback and reduces its switching frequency. The peak
current setpoint is following the feedback pin until its level
reaches 1.05 V. Below this value, the peak current freezes to
Vfold/4.2 (250 mV or 31% of the maximum 0.8−V setpoint)
and the only way to further reduce the transmitted power is
to diminish the operating frequency down to 26 kHz. This
value is reached at a feedback voltage level of 350 mV
typically. Below this point, if the output power continues to
decrease, the part enters skip cycle for the best noise−free
performance in no−load conditions. depicts the adopted
scheme for the part.
1 Meg
Vcc
Figure 26. The Full−wave Connection Ensures Latch
Current Continuity as well as a X2−Discharge Path.
http://onsemi.com
12
NCP1253
Frequency
Peak current setpoint
Fsw
FB
VCS
max
65 kHz
max
0.8 V
[0.36 V
min
26 kHz
350 mV
Vfold,end
1.5 V
Vfold
3.4 V
[0.25 V
VFB
min
Vfreeze Vfold
1.05 V
1.5 V
3.4 V
VFB
Figure 27. By Observing the Voltage on the Feedback Pin, the Controller Reduces its Switching Frequency for an
Improved Performance at Light Load
Auto−recovery Short−Circuit Protection
to the resistive starting network. When VCC reaches
VCCON, the controller attempts to re−start, checking for the
absence of the fault. If the fault is still there, the supply enters
another cycle of so−called hiccup. If the fault has
disappeared, the power supply resumes operations. Please
note that the soft−start is activated during each of the re−start
sequence.
In case of output short−circuit or if the power supply
experiences a severe overloading situation, an internal error
flag is raised and starts a countdown timer. If the flag is
asserted longer than 100 ms, the driving pulses are stopped
and VCC falls down as the auxiliary pulses are missing.
When it crosses VCC(min), the controller consumption is
down to a few mA and the VCC slowly builds up again thanks
15.9
4.32
14.8
9.90
3.35
6.05
vcc in volts
23.6
3.89
ilprim in amperes
Plot1
vdrv in volts
1 vcc
2 vdrv
3 ilprim
1
Vcc (t )
VDRV (t )
2.38
2
−2.72
−2.12
1.41
ILp (t )
SS
−11.5
−8.13
445m
500u
1.50m
2.50m
time in seconds
3.50m
4.50m
3
Figure 28. An Auto−Recovery Hiccup Mode is Entered in Case a Faulty Event Longer Than 100 ms is
Acknowledged by the Controller
Ramp compensation
CCM−operated
current−mode
converters.
These
oscillations take place at half the switching frequency and
occur only during Continuous Conduction Mode (CCM)
with a duty−cycle greater than 50%. To lower the current
loop gain, one usually injects between 50% and 100% of the
inductor downslope.
The NCP1253 includes an internal ramp compensation
signal. This is the buffered oscillator clock delivered during
the on time only. Its amplitude is around 2.5 V at the
maximum duty−cycle. Ramp compensation is a known
means used to cure sub harmonic oscillations in
http://onsemi.com
13
NCP1253
2.5 V
0V
ON
latch
reset
20k
+
Rcomp
L.E.B
CS
−
Rsense
from FB
setpoint
Figure 29. Inserting a Resistor in Series with the Current Sense Information Brings Ramp Compensation and
Stabilizes the Converter in CCM Operation
In the NCP1253 controller, the oscillator ramp features a
2.5 V swing. If the clock operates at a 65 kHz frequency,
then the available oscillator slope corresponds to:
S ramp +
V ramp,peakD max
T SW
2.5 0.8
+
15m
S sense + S PR sense + 103k
If we select 50% of the downslope as the required amount
of ramp compensation, then we shall inject a ramp whose
slope is 17 mV/ms. Our internal compensation being of
133 mV/ms, the divider ratio (divratio) between Rcomp and
the internal 20 kW resistor is:
(eq. 6)
In our flyback design, let’s assume that our primary
inductance Lp is 770 mH, and the SMPS delivers 19 V with
a Np :Ns ratio of 1:0.25. The off−time primary current slope
Sp is thus given by:
N
SP +
P
LP
+
(19 ) 0.8)
770m
4
(eq. 8)
+ 34 kVńs or 34 mVńms
+ 133 kVńs or 133 mVńms
ǒV out ) V fǓ N s
0.33
divratio +
17m
+ 0.127
133m
(eq. 9)
The series compensation resistor value is thus:
R comp + R rampdivratio + 20k
(eq. 7)
0.127 [ 2.5 kW (eq. 10)
A resistor of the above value will then be inserted from the
sense resistor to the current sense pin. We recommend
adding a small 100 pF capacitor, from the current sense pin
to the controller ground for improved noise immunity.
Please make sure both components are located very close to
the controller.
+ 103 kAńs
Given a sense resistor of 330 mW, the above current ramp
turns into a voltage ramp of the following amplitude:
http://onsemi.com
14
NCP1253
PACKAGE DIMENSIONS
TSOP−6
CASE 318G−02
ISSUE U
D
H
ÉÉÉ
ÉÉÉ
6
E1
1
NOTE 5
5
2
L2
4
GAUGE
PLANE
E
3
L
b
C
DETAIL Z
e
0.05
M
A
SEATING
PLANE
c
A1
DETAIL Z
NOTES:
1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M, 1994.
2. CONTROLLING DIMENSION: MILLIMETERS.
3. MAXIMUM LEAD THICKNESS INCLUDES LEAD FINISH. MINIMUM
LEAD THICKNESS IS THE MINIMUM THICKNESS OF BASE MATERIAL.
4. DIMENSIONS D AND E1 DO NOT INCLUDE MOLD FLASH,
PROTRUSIONS, OR GATE BURRS. MOLD FLASH, PROTRUSIONS, OR
GATE BURRS SHALL NOT EXCEED 0.15 PER SIDE. DIMENSIONS D
AND E1 ARE DETERMINED AT DATUM H.
5. PIN ONE INDICATOR MUST BE LOCATED IN THE INDICATED ZONE.
DIM
A
A1
b
c
D
E
E1
e
L
L2
M
MIN
0.90
0.01
0.25
0.10
2.90
2.50
1.30
0.85
0.20
0°
MILLIMETERS
NOM
MAX
1.00
1.10
0.06
0.10
0.38
0.50
0.18
0.26
3.00
3.10
2.75
3.00
1.50
1.70
0.95
1.05
0.40
0.60
0.25 BSC
10°
−
STYLE 13:
PIN 1. GATE 1
2. SOURCE 2
3. GATE 2
4. DRAIN 2
5. SOURCE 1
6. DRAIN 1
RECOMMENDED
SOLDERING FOOTPRINT*
6X
0.60
6X
3.20
0.95
0.95
PITCH
DIMENSIONS: MILLIMETERS
*For additional information on our Pb−Free strategy and soldering
details, please download the ON Semiconductor Soldering and
Mounting Techniques Reference Manual, SOLDERRM/D.
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice
to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
“Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All
operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights
nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications
intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should
Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates,
and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death
associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal
Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: [email protected]
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5817−1050
http://onsemi.com
15
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
NCP1253/D
Similar pages