ACDC 400 Watts FCM Series xppower.com • 400 W Continuous, 600 W Peak • IT and Medical Approvals • 80 V 275 VAC Operation • Low Noise Fan • Screw Terminals • 5 V Standby, AC OK and Remote On/Off • 3 Year Warranty Specification Input General • 80-275 VAC, derate output power <90 VAC (see derating curve) Input Frequency • 47-63 Hz Input Current • 4.1 A at 115 VAC typical 2.1 A at 230 VAC with 400 W load Inrush Current • 60 A max at 264 VAC, cold start 25 °C Power Factor • >0.9 Earth Leakage Current • 260 µA max, 264 VAC, 60 Hz Input Protection • F10 A / 250 V internal fuse in line and neutral Input Voltage Output 12-48 VDC (see tables) ±10% V1 ±1% V1, ±5% V2 No minimum load required 1 s typical 50 ms 20 ms minimum ±0.5% maximum ±1% V1, ±5% V2 4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change Ripple & Noise • 1% pk-pk, 20 MHz bandwidth Overvoltage Protection • 115-140% Vnom, recycle input to reset Overtemperature • Auto reset Protection Overload Protection • 150-165%, V1 only Short Circuit Protection • Continuous, approximately constant current Temperature • 0.05% / °C Coefficient Remote On/Off • Uncommitted isolated optocoupler diode, powered diode inhibits V1 & Fan Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • • Efficiency Isolation Switching Frequency Power Density Signals MTBF • 85% typical • 4000 VAC input to output, 2 x MOPP, 1500 VAC input to ground, 1 x MOPP, 500 VAC output to ground • PFC 70 kHz, main converter 65 kHz typical • 8.6 W/in3 • AC OK, remote on/off, 5 V standby • 236 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • -10 °C to +70 °C, derate linearly from +50 °C at 2.5% / °C to 50% load at +70 °C Cooling • Forced cooled with integral fan Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Operating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 kHz, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals • EN55011/22 level B conducted EN55011/22 level A radiated • EN61000-3-2, class A EN61000-3-2, class C for loads ≥50% • EN61000-3-3 • EN61000-4-3, level 3 Perf Criteria A • EN61000-4-4, level 3 Perf Criteria A • EN61000-4-5, installation class 3, Perf Criteria A • EN61000-4-6, level 3, Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation • IEC60950-1 CB report, UL60950-1, TUV, EN60950-1, IEC60601-1 CB report, CSA 22.2 No.60601-1, ANSI/AAMI ES60601-1, TUV60601-1, including risk management Output Voltage V1 12 V Output Current V1 Continuous Peak(1) 33.3 A 50.0 A Output Power Continuous Peak(1) 400 W 600 W Standby Supply V2 5 V / 0.5 A Model Number FCM400PS12 15 V 26.6 A 40.0 A 5 V / 0.5 A 400 W 600 W FCM400PS15 24 V 16.6 A 25.0 A 5 V / 0.5 A 400 W 600 W FCM400PS24 28 V 14.2 A 21.4 A 5 V / 0.5 A 400 W 600 W FCM400PS28 36 V 11.1 A 16.7 A 5 V / 0.5 A 400 W 600 W FCM400PS36 48 V 8.3 A 12.5 A 5 V / 0.5 A 400 W 600 W FCM400PS48 Notes 1. Peak Output Power - The peak duration is 500 ms maximum, average power must not exceed 400 W. Mechanical Details 6.00 ±0.02 (152.4 ±0.5) NOT INCLUDING OUTPUT TERMINAL SCREWS Input Connector Tyco part #640445-5 OUTPUT VOLTAGE ADJUSTMENT Pin 1 Pin 2 Pin 3 2 OUTPUT TERMINALS ALLOW CONNECTION FROM EITHER TOP OR SIDE 1 4.00 ±0.02 (101.6 ±0.5) J1 mates with Tyco MTA-156 & SL-156 product lines OUTPUT TERMINALS M4 SCREWS IN 2 POSITIONS. TORQUE TO 90 cNm Max. INPUT CONNECTOR M3 MOUNTING HOLES (IN 4 POSITIONS). MAX. PENETRATION BY SCREW TO BE 2.5mm FROM BOTTOM FACE OF CHASSIS 0.52 (13.3) 2.95 (75.0) Line Neutral Earth Pin 2 Pin 1 Pin 10 Pin 9 SIGNALS CONNECTOR CON8 10-WAY JST-BIOB-PDHSS Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin 1 2 3 4 5 6 7 8 9 10 Signals Connector 5 V Standby Return 5 V Standby 5 V Standby Return 5 V Standby 5 V Standby Return 5 V Standby Power Fail (Collector) Power Fail (Emitter) Remote On / Off (Cathode) Remote On / Off (Anode) Mating plug: JST p/n PHDR-10VS Contact: 26-22 AWG JST p/n SPHD-001T-P0.5 3.94 (100.0) Output Connector Pin 1 +V1 Pin 2 V1 RTN 1.03 (26.2) Notes M3 MOUNTING HOLES (IN 2 POSITIONS). MAX. PENETRATION BY SCREW TO BE 3.5mm FROM OUTSIDE FACE OF CHASSIS 1. Dimensions shown in inches (mm). Tolerance: ±0.02 (±0.5) 2. Weight: 1.8 lb (800 g). 1.93 ±0.02 (49.0 ±0.5) 0.96 (24.3) 2.10 (53.4) HEIGHT INCLUDES EMBOSSED FAN COVER 3.35 (85.0) Input Voltage & Temperature Derating 600 600 540 Output Power (W) Peak Power Availability 400 360 500 Peak Power Availability 400 300 320 200 300 100 0 80 85 90 Input Voltage (VAC) 264 275 -10 0 10 40 Ambient Temperature (°C) 50 60 70 07-Nov-11 ACDC FCM400 Models and Ratings