XP Power FCM 400 w continuous, 600 w peak Datasheet

ACDC
400 Watts
FCM Series
xppower.com
•
400 W Continuous, 600 W Peak
•
IT and Medical Approvals
•
80 V 275 VAC Operation
•
Low Noise Fan
•
Screw Terminals
•
5 V Standby, AC OK and Remote On/Off
•
3 Year Warranty
Specification
Input
General
• 80-275 VAC, derate output power
<90 VAC (see derating curve)
Input Frequency
• 47-63 Hz
Input Current
• 4.1 A at 115 VAC typical
2.1 A at 230 VAC with 400 W load
Inrush Current
• 60 A max at 264 VAC, cold start 25 °C
Power Factor
• >0.9
Earth Leakage Current • 260 µA max, 264 VAC, 60 Hz
Input Protection
• F10 A / 250 V internal fuse in line
and neutral
Input Voltage
Output
12-48 VDC (see tables)
±10% V1
±1% V1, ±5% V2
No minimum load required
1 s typical
50 ms
20 ms minimum
±0.5% maximum
±1% V1, ±5% V2
4% max. deviation, recovery to
within 1% in 500 µs for a 50-75-50%
load change
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overtemperature
• Auto reset
Protection
Overload Protection
• 150-165%, V1 only
Short Circuit Protection • Continuous, approximately constant
current
Temperature
• 0.05% / °C
Coefficient
Remote On/Off
• Uncommitted isolated optocoupler diode,
powered diode inhibits V1 & Fan
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 85% typical
• 4000 VAC input to output, 2 x MOPP,
1500 VAC input to ground, 1 x MOPP,
500 VAC output to ground
• PFC 70 kHz, main converter 65 kHz typical
• 8.6 W/in3
• AC OK, remote on/off, 5 V standby
• 236 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -10 °C to +70 °C, derate linearly
from +50 °C at 2.5% / °C to 50%
load at +70 °C
Cooling
• Forced cooled with integral fan
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 kHz, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55011/22 level B conducted
EN55011/22 level A radiated
• EN61000-3-2, class A
EN61000-3-2, class C for loads ≥50%
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, level 3, Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation
• IEC60950-1 CB report, UL60950-1, TUV,
EN60950-1, IEC60601-1 CB report, CSA
22.2 No.60601-1, ANSI/AAMI ES60601-1,
TUV60601-1, including risk management
Output Voltage V1
12 V
Output Current V1
Continuous
Peak(1)
33.3 A
50.0 A
Output Power
Continuous
Peak(1)
400 W
600 W
Standby Supply V2
5 V / 0.5 A
Model Number
FCM400PS12
15 V
26.6 A
40.0 A
5 V / 0.5 A
400 W
600 W
FCM400PS15
24 V
16.6 A
25.0 A
5 V / 0.5 A
400 W
600 W
FCM400PS24
28 V
14.2 A
21.4 A
5 V / 0.5 A
400 W
600 W
FCM400PS28
36 V
11.1 A
16.7 A
5 V / 0.5 A
400 W
600 W
FCM400PS36
48 V
8.3 A
12.5 A
5 V / 0.5 A
400 W
600 W
FCM400PS48
Notes
1. Peak Output Power - The peak duration is 500 ms maximum, average power must not exceed 400 W.
Mechanical Details
6.00 ±0.02
(152.4 ±0.5)
NOT INCLUDING OUTPUT
TERMINAL SCREWS
Input Connector
Tyco part #640445-5
OUTPUT VOLTAGE
ADJUSTMENT
Pin 1
Pin 2
Pin 3
2
OUTPUT TERMINALS
ALLOW CONNECTION
FROM EITHER TOP OR SIDE
1
4.00 ±0.02
(101.6 ±0.5)
J1 mates with Tyco MTA-156 & SL-156
product lines
OUTPUT TERMINALS
M4 SCREWS IN 2
POSITIONS. TORQUE
TO 90 cNm Max.
INPUT CONNECTOR
M3 MOUNTING HOLES (IN 4 POSITIONS). MAX. PENETRATION
BY SCREW TO BE 2.5mm FROM BOTTOM FACE OF CHASSIS
0.52
(13.3)
2.95
(75.0)
Line
Neutral
Earth
Pin 2
Pin 1
Pin 10
Pin 9
SIGNALS CONNECTOR CON8
10-WAY JST-BIOB-PDHSS
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
1
2
3
4
5
6
7
8
9
10
Signals Connector
5 V Standby Return
5 V Standby
5 V Standby Return
5 V Standby
5 V Standby Return
5 V Standby
Power Fail (Collector)
Power Fail (Emitter)
Remote On / Off (Cathode)
Remote On / Off (Anode)
Mating plug:
JST p/n PHDR-10VS
Contact:
26-22 AWG JST p/n
SPHD-001T-P0.5
3.94
(100.0)
Output Connector
Pin 1
+V1
Pin 2
V1 RTN
1.03
(26.2)
Notes
M3 MOUNTING HOLES (IN 2 POSITIONS). MAX. PENETRATION
BY SCREW TO BE 3.5mm FROM OUTSIDE FACE OF CHASSIS
1. Dimensions shown in inches (mm).
Tolerance: ±0.02 (±0.5)
2. Weight: 1.8 lb (800 g).
1.93 ±0.02
(49.0 ±0.5)
0.96
(24.3)
2.10
(53.4)
HEIGHT INCLUDES
EMBOSSED FAN COVER
3.35
(85.0)
Input Voltage & Temperature Derating
600
600
540
Output Power (W)
Peak Power Availability
400
360
500
Peak Power Availability
400
300
320
200
300
100
0
80
85
90
Input Voltage (VAC)
264
275
-10
0
10
40
Ambient Temperature (°C)
50
60
70
07-Nov-11
ACDC
FCM400
Models and Ratings