Holtek HT7530-1 100ma low power ldo Datasheet

HT75xx-1
100mA Low Power LDO
Features
· Low power consumption
· High output current : 100mA
· Low voltage drop
· Output voltage accuracy: tolerance ±3%
· Low temperature coefficient
· TO92, SOT89 and SOT23-5 package
· High input voltage (up to 24V)
Applications
· Battery-powered equipment
· Audio/Video equipment
· Communication equipment
General Description
The HT75xx-1 series is a set of three-terminal high current low voltage regulator implemented in CMOS technology. They can deliver 100mA output current and
allow an input voltage as high as 24V. They are available with several fixed output voltages ranging from
2.1V to 12.0V. CMOS technology ensures low voltage
drop and low quiescent current.
Although designed primarily as fixed voltage regulators,
these devices can be used with external components to
obtain variable voltages and currents.
Selection Table
Note:
Part No.
Output Voltage
HT7521-1
2.1V
HT7523-1
2.3V
HT7525-1
2.5V
HT7527-1
2.7V
HT7530-1
3.0V
HT7533-1
3.3V
HT7536-1
3.6V
HT7540-1
4.0V
HT7544-1
4.4V
HT7550-1
5.0V
HT7560-1
6.0V
HT7570-1
7.0V
HT7580-1
8.0V
HT7590-1
9.0V
HT75A0-1
10.0V
HT75C0-1
12.0V
Package
TO92
SOT89
SOT23-5
Marking
75xx-1 (for TO92)
75xx-1 (for SOT89)
75xx-1# (for SOT89)
75xx-1+ (for SOT89)
5xx1 (for SOT23-5)
5xx1# (for SOT23-5)
5xx1+ (for SOT23-5)
²xx² stands for output voltages.
Both lead free and green compound devices are available. Note the symbol marks below:
²#² stands for lead free devices.
Blank and ²+² stands for green compound devices, which are Lead-free and Halogen-free.
For the TO92 package, the symbol mark will be at the end of the date code. Whereas for the SOT89 and
SOT23-5, the symbol mask will be located at the end of IC marking.
Rev. 2.20
1
April 30, 2013
HT75xx-1
Block Diagram
V IN
V O U T
V re f
G N D
Pin Assignment
T O 9 2
S O T 8 9
7 5 x x -1
S O T 2 3 -5
N C
F r o n t V ie w
7 5 x x -1
G N D
V IN
V O U T
G N D
V IN
G N D
V IN
N C
T o p V ie w
5 x x 1
V O U T
G N D
V IN
V O U T
G N D
V IN
V O U T
S id e V ie w
V O U T
Absolute Maximum Ratings
Supply Voltage .........................................-0.3V to 26V
Storage Temperature ...........................-50°C to 125°C
Operating Temperature ..........................-40°C to 85°C
Note: These are stress ratings only. Stresses exceeding the range specified under ²Absolute Maximum Ratings² may
cause substantial damage to the device. Functional operation of this device at other conditions beyond those listed
in the specification is not implied and prolonged exposure to extreme conditions may affect device reliability.
Thermal Information
Symbol
qJA
PD
Parameter
Thermal Resistance
(Junction to Ambient)
(Assume no ambient airflow,
no heat sink)
Power Dissipation
Package
Max.
Unit
SOT23-5
500
°C/W
SOT89
200
°C/W
TO92
200
°C/W
SOT23-5
0.20
W
SOT89
0.50
W
TO92
0.50
W
Note: PD is measured at Ta= 25°C
Rev. 2.20
2
April 30, 2013
HT75xx-1
Electrical Characteristics
HT7521-1, +2.1V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VOUT
Output Voltage
4.1V
IOUT
Output Current
4.1V
DVOUT
Load Regulation
4.1V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
¾
4.1V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
2.037
2.1
2.163
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
3.1V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.37
¾
mV/°C
VIN
4.1V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT7523-1, +2.3V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VOUT
Output Voltage
4.3V
IOUT
Output Current
4.3V
DVOUT
Load Regulation
4.3V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
E T
O U T
¾
4.3V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
2.231
2.3
2.369
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
3.3V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.39
¾
mV/°C
VIN
4.3V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
3
April 30, 2013
HT75xx-1
HT7525-1, +2.5V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VOUT
Output Voltage
4.5V
IOUT
Output Current
4.5V
DVOUT
Load Regulation
4.5V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
¾
4.5V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Typ.
Max.
2.425
2.5
2.575
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
3.5V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.41
¾
mV/°C
VIN
4.5V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Min.
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT7527-1, +2.7V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
Output Voltage
4.7V
IOUT
Output Current
4.7V
DVOUT
Load Regulation
4.7V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
E T
O U T
¾
4.7V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
2.619
2.7
2.781
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
3.7V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.43
¾
mV/°C
VIN
VOUT
D V
Unit
4.7V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
4
April 30, 2013
HT75xx-1
HT7530-1, +3.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VIN
VOUT
Output Voltage
5.0V
IOUT
Output Current
5.0V
DVOUT
Load Regulation
5.0V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
5.0V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
¾
5.0V
Conditions
IOUT=10mA
¾
Min.
Typ.
Max.
2.91
3.0
3.09
V
60
100
¾
mA
60
150
mV
1mA£IOUT£50mA
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
4.0V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.45
¾
mV/°C
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT7533-1, +3.3V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
Output Voltage
5.5V
IOUT
Output Current
5.5V
DVOUT
Load Regulation
5.5V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
E T
O U T
¾
5.5V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
3.201
3.3
3.399
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
4.5V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.5
¾
mV/°C
VIN
VOUT
D V
Unit
5.5V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
5
April 30, 2013
HT75xx-1
HT7536-1, +3.6V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VOUT
Output Voltage
5.6V
IOUT
Output Current
5.6V
DVOUT
Load Regulation
5.6V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
¾
5.6V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Typ.
Max.
3.492
3.6
3.708
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
4.6V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.6
¾
mV/°C
VIN
5.6V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Min.
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT7540-1, +4.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
Output Voltage
6.0V
IOUT
Output Current
6.0V
DVOUT
Load Regulation
6.0V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
E T
O U T
¾
6.0V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
3.88
4.0
4.12
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
5.0V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.7
¾
mV/°C
VIN
VOUT
D V
Unit
6.0V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
6
April 30, 2013
HT75xx-1
HT7544-1, +4.4V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VOUT
Output Voltage
6.4V
IOUT
Output Current
6.4V
DVOUT
Load Regulation
6.4V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
¾
6.4V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Typ.
Max.
4.268
4.4
4.532
V
60
100
¾
mA
1mA£IOUT£50mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
5.4V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.7
¾
mV/°C
VIN
6.4V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Min.
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT7550-1, +5.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
Output Voltage
7.0V
IOUT
Output Current
7.0V
DVOUT
Load Regulation
7.0V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
E T
O U T
¾
7.0V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
4.85
5.0
5.15
V
100
150
¾
mA
1mA£IOUT£70mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
6.0V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.75
¾
mV/°C
VIN
VOUT
D V
Unit
7.0V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
7
April 30, 2013
HT75xx-1
HT7560-1, +6.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VOUT
Output Voltage
8.0V
IOUT
Output Current
8.0V
DVOUT
Load Regulation
8.0V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
¾
8.0V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
5.82
6.0
6.18
V
150
¾
¾
mA
1mA£IOUT£70mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
7.0V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.85
¾
mV/°C
VIN
8.0V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT7570-1, +7.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
Output Voltage
9.0V
IOUT
Output Current
9.0V
DVOUT
Load Regulation
9.0V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
E T
O U T
¾
9.0V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
6.79
7.0
7.21
V
150
¾
¾
mA
1mA£IOUT£70mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
8.0V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±0.95
¾
mV/°C
VIN
VOUT
D V
Unit
9.0V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
8
April 30, 2013
HT75xx-1
HT7580-1, +8.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VOUT
Output Voltage
10V
IOUT
Output Current
10V
DVOUT
Load Regulation
10V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
¾
10V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
7.76
8.0
8.24
V
150
¾
¾
mA
1mA£IOUT£70mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
9.0V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±1.10
¾
mV/°C
VIN
10V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT7590-1, +9.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
Output Voltage
11V
IOUT
Output Current
11V
DVOUT
Load Regulation
11V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
E T
O U T
¾
11V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
Min.
Typ.
Max.
Unit
8.73
9.0
9.27
V
150
¾
¾
mA
1mA£IOUT£70mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
10V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±1.15
¾
mV/°C
VIN
VOUT
D V
Unit
11V
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
9
April 30, 2013
HT75xx-1
HT75A0-1, +10.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VIN
VOUT
Output Voltage
12V
IOUT
Output Current
12V
DVOUT
Load Regulation
12V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
O U T
VIN
D V D
D T
E T
Note:
12V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
¾
12V
Conditions
IOUT=10mA
Min.
Typ.
Max.
9.7
10.0
10.3
V
150
¾
¾
mA
1mA£IOUT£70mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
11V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±1.25
¾
mV/°C
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
HT75C0-1, +12.0V Output Type
Symbol
Parameter
Ta=25°C
Test Conditions
VIN
VOUT
Output Voltage
14V
IOUT
Output Current
14V
DVOUT
Load Regulation
14V
VDIF
Voltage Drop (Note)
ISS
Current Consumption
D V
D V
IN
O U T
´ V
VIN
D V D
D T
Note:
Unit
E T
O U T
14V
Line Regulation
¾
Input Voltage
¾
Temperature Coefficient
a
¾
14V
Min.
Typ.
Max.
Unit
11.64
12.0
12.36
V
150
¾
¾
mA
1mA£IOUT£70mA
¾
60
150
mV
IOUT=1mA, DVOUT=2%
¾
100
¾
mV
No load
¾
2.5
5.0
mA
13V£VIN£24V
IOUT=1mA
¾
0.2
¾
%/V
¾
¾
24
V
¾
±1.45
¾
mV/°C
Conditions
IOUT=10mA
¾
¾
IOUT=10mA
-40°C<Ta<85°C
Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the
output voltage from the value at VIN = VOUT+2V with a fixed load.
Rev. 2.20
10
April 30, 2013
HT75xx-1
Typical Performance Characteristics
Rev. 2.20
11
April 30, 2013
HT75xx-1
Rev. 2.20
12
April 30, 2013
HT75xx-1
Rev. 2.20
13
April 30, 2013
HT75xx-1
Application Circuits
Basic Circuit
V
IN
V
H T 7 5 x x -1
S e r ie s
IN
C 1
1 0 m F
V
V
O U T
C 2
1 0 m F
G N D
C o m m o n
O U T
C o m m o n
S in g le p o in t G N D
High Output Current Positive Voltage Regulator
T r1
V
V
IN
H T 7 5 x x -1
S e r ie s
IN
R 1
V
V
O U T
G N D
C 1
1 0 m F
C o m m o n
O U T
C 2
1 0 m F
C o m m o n
S in g le p o in t G N D
Short-Circuit Protection for Tr1
V
R s
IN
T r1
V
R 1
C 1
1 0 m F
IN
H T 7 5 x x -1
S e r ie s
O U T
C 2
1 0 m F
S in g le p o in t G N D
14
V
O U T
G N D
C o m m o n
Rev. 2.20
V
C o m m o n
April 30, 2013
HT75xx-1
Circuit for Increasing Output Voltage
V
V
IN
IN
V
H T 7 5 x x -1
S e r ie s
C 1
1 0 m F
G N D
IS
V
O U T
C 2
1 0 m F
S
V
O U T
R 1
X X
R 2
C o m m o n
S in g le p o in t G N D
C o m m o n
R2
) + ISS R2
R1
VOUT = VXX ( 1 +
Circuit for Increasing Output Voltage
V
V
IN
IN
V
H T 7 5 x x -1
S e r ie s
C 1
1 0 m F
G N D
IS
V
O U T
C 2 V
1 0 m F
S
X X
O U T
R 1
D 1
C o m m o n
S in g le p o in t G N D
C o m m o n
VOUT = VXX + VD1
Constant Current Regulator
V
V
IN
IN
V
H T 7 5 x x -1
S e r ie s
C 1
1 0 m F
G N D
IS
O U T
C 2
1 0 m F V
S
X X
R
A
IO
U T
R
L
C o m m o n
IOUT =
VXX
+ ISS
RA
Dual Supply
IC 1
V
V
IN
IN
H T 7 5 x x -1
S e r ie s
IC 2
V
C 1
1 0 m F
IN
H T 7 5 x x -1
S e r ie s
G N D
V
O U T
O U T
V
C 2
1 0 m F
C o m m o n
Rev. 2.20
O U T
C 3
1 0 m F
G N D
V
V
O U T
R 1
C o m m o n
15
April 30, 2013
HT75xx-1
Package Information
Note that the package information provided here is for consultation purposes only. As this information may be updated
at regular intervals users are reminded to consult the Holtek website for the latest version of the package information.
Additional supplementary information with regard to packaging is listed below. Click on the relevant section to be
transferred to the relevant website page.
· Further Package Information (include Outline Dimensions, Product Tape and Reel Specifications)
· Packing Meterials Information
· Carton information
· PB FREE Products
· Green Packages Products
Rev. 2.20
16
April 30, 2013
HT75xx-1
3-pin TO92 Outline Dimensions
A
B
D
C
E
F
G
H
Symbol
Nom.
Max.
A
0.170
¾
0.200
B
0.170
¾
0.200
C
0.500
¾
¾
D
0.011
¾
0.020
E
0.090
¾
0.110
F
0.045
¾
0.055
G
0.045
¾
0.065
H
0.130
¾
0.160
a
0°
¾
10°
Symbol
A
Rev. 2.20
Dimensions in inch
Min.
Dimensions in mm
Min.
Nom.
Max.
4.32
¾
5.08
B
4.32
¾
5.08
C
12.70
¾
¾
D
0.28
¾
0.51
E
2.29
¾
2.79
F
1.14
¾
1.40
G
1.14
¾
1.65
H
3.30
¾
4.06
a
0°
¾
10°
17
April 30, 2013
HT75xx-1
3-pin SOT89 Outline Dimensions
I
A
J
B
C
E
D
G
F
Symbol
Dimensions in inch
Min.
Nom.
Max.
A
0.173
¾
0.181
B
0.059
¾
0.072
C
0.090
¾
0.102
D
0.035
¾
0.047
E
0.155
¾
0.167
F
0.014
¾
0.019
G
0.017
¾
0.022
H
¾
0.059
¾
I
55
¾
63
J
14
¾
17
Symbol
A
Rev. 2.20
H
Dimensions in mm
Min.
Nom.
Max.
4.39
¾
4.60
B
1.50
¾
1.83
C
2.29
¾
2.59
D
0.89
¾
1.19
E
3.94
¾
4.24
F
0.36
¾
0.48
G
0.43
¾
0.56
H
¾
1.50
¾
I
1.40
¾
1.60
J
0.36
¾
0.43
18
April 30, 2013
HT75xx-1
5-pin SOT23-5 Outline Dimensions
D
C
L
H
E
q
e
A
A 2
b
Symbol
Dimensions in inch
Min.
Nom.
Max.
0.039
¾
0.051
A1
¾
¾
0.004
A2
0.028
¾
0.035
A
b
0.014
¾
0.020
C
0.004
¾
0.010
D
0.106
¾
0.122
E
0.055
¾
0.071
e
¾
0.075
¾
H
0.102
¾
0.118
L
0.015
¾
¾
q
0°
¾
9°
Symbol
Rev. 2.20
A 1
Dimensions in mm
Min.
Nom.
Max.
A
1.00
¾
1.30
A1
¾
¾
0.10
A2
0.70
¾
0.90
b
0.35
¾
0.50
C
0.10
¾
0.25
D
2.70
¾
3.10
E
1.40
¾
1.80
e
¾
1.90
¾
H
2.60
¾
3.0
L
0.37
¾
¾
q
0°
¾
9°
19
April 30, 2013
HT75xx-1
Copyright Ó 2013 by HOLTEK SEMICONDUCTOR INC.
The information appearing in this Data Sheet is believed to be accurate at the time of publication.
However, Holtek assumes no responsibility arising from the use of the specifications described.
The applications mentioned herein are used solely for the purpose of illustration and Holtek
makes no warranty or representation that such applications will be suitable without further modification, nor recommends the use of its products for application that may present a risk to human
life due to malfunction or otherwise. Holtek¢s products are not authorized for use as critical components in life support devices or systems. Holtek reserves the right to alter its products without
prior notification. For the most up-to-date information, please visit our web site at
http://www.holtek.com.tw.
Rev. 2.20
20
April 30, 2013
Similar pages