LEM HTA1000-S Current transducer hta 100~1000- Datasheet

Current Transducer HTA 100..1000-S
IPN = 100 A
For the electronic measurement of DC, AC and pulsed currents,
with a galvanic isolation between the primary (high power) circuit
and the secondary (electronic) circuit.
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
100
200
300
400
500
600
1000
ÎP
VOUT
RL
VC
IC
Vb
Vd
Ris
± 300
± 600
± 900
± 1000
± 1000
± 1000
± 1000
Overload capacity (Ampere Turns)
Analogue output voltage @ ± IPN
Load resistance
TA = 0 .. + 70°C
TA = - 25 .. + 85°C
Supply voltage (± 5 %)
Current consumption (max)
Rms rated voltage1)
Rms voltage for AC isolation test, 50 Hz, 1 mn
Isolation resistance @ 500 VDC
Type
Features
HTA 100-S
HTA 200-S
HTA 300-S
HTA 400-S
HTA 500-S
HTA 600-S
HTA 1000-S
30000
±4
>1
>3
± 15
25
500
3
> 500
• Open loop transducer using Hall
Effect
• Panel mounting - Horizontal or
Vertical
A
V
kΩ
kΩ
V
mA
V
kV
MΩ
Accuracy - Dynamic performance data
Accuracy 2) @ IPN, TA = 25°C, @ ± 15 V
Linearity 2)
X
ε
L
VOE
VOM
VOT
TCε G
tr
di/dt
f
Electrical offset voltage @ IP = 0, TA = 25°C
Residual offset voltage @ IP = 0
after an overload of 3 x IPN
Thermal drift of offset voltage TA = - 25 .. + 85°C
Thermal drift of gain TA = - 25 .. + 85°C
Response time @ 90 % of IP
di/dt accurately followed
Frequency bandwidth (- 3 dB) 3)
±1
± 0.5
Max
± 10
± 10
±1
± 0.05
<3
> 50
DC .. 50
%
%
mV
mV
mV/°K
%/°K
µs
A/µs
kHz
Ambient operating temperature
Ambient storage temperature
Mass
Standards Safety
EMC
Deviation in output when tested to EN 61000-4-6
Deviation in output when tested to EN 61000-4-4
Notes :
1)
2)
3)
•
•
•
•
•
•
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external
interference
• Current overload capability
• Low power consumption
• Wide dynamic range, 100 to 1000 A
in one package.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptable Power Supplies
• Switched Mode Power Supplies
- 25 .. + 85
°C
- 25 .. + 85
°C
230
g
EN50178 (1994)
EN50082-2 (1992)
EN50081-1 (1992)
< 10
% of IPN
< 10
% of IPN
Overvoltage Category III, Pollution Degree 2
Excludes the electrical offset
Refer to derating curves in the technical file to avoid excessive core
heating at high frequency
LEM Components
Advantages
(UPS)
General data
TA
TS
m
• Insulated plastic case to UL 94-V0.
(SMPS)
• Power supplies for welding
applications.
001107/1
www.lem.com
Dimensions HTA 100..1000-S (in mm)
Bottom view
Left view
Secondary terminals
Terminal
Terminal
Terminal
Terminal
1
2
3
4
: supply voltage + 15 V
: supply voltage - 15 V
: output
: 0V
Front view
Mechanical characteristics
• General tolerance
• Primary through-hole
• Connection of secondary
Remarks
± 0.5 mm
Ø 32 mm
Molex 5045-04-A
• VOUT is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
90°C.
• This is a standard model. For different versions (supply
voltages, secondary connections, unidirectional measurements, operating temperatures, etc.) please contact us.
LEM have a policy of continual product improvement and the company reserves the right to revise the above specification without prior notice.