Carling DA1-B0-34-450-121 Circuit breaker Datasheet

D-Series
Circuit Breaker
Designed for snap-on-back panel rail mounting on either
a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din
Rail, allowing rapid and simple mounting and removal
of the breaker. It features recessed, wire-ready, touchproof, shock-resistant terminals, suitable for automatic
screwdriver assembly, as well as “Dead Front” construction
characteristics.
Available with a Visi-Rocker two-color actuator, which
can be specified to indicate either the ON or the TRIPPED/
OFF mode, or solid color rocker or handle type actuators.
All actuator types fit in the same industry standard panel
cutouts.
Features:
ŠŠ 0.02 - 50 Amps
ŠŠ 480 VAC or 65 VDC
ŠŠ 1-4 poles (Handle)
ŠŠ 1-3 poles (Rocker)
ŠŠ Choice of Time Delays
ŠŠ DIN rail mounting
ŠŠ Precise temperature independent operation
ŠŠ Wiping contacts – mechanical linkage with two-step
ŠŠ Finger safe terminals
ŠŠ Common trip linkage between poles – ensures that an
overload in one pole will trip all adjacent poles
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
2 | D-Series Circuit Breaker - General Specifications
Electrical
Mechanical
Maximum Voltage
Endurance
AC, 480 wye/277 VAC
(See Table A), 50/60 Hz, 65VDC
Standard Current Coils 0.100, 0.250, 0.500, 0.750, 1.00,
2.50, 5.00, 7.50, 10.0, 15.0, 20.0,
25.0, 30.0, 35.0, 40.0 & 50.0.
Other ratings available - consult factory.
Standard Voltage Coils DC - 6V, 12V; AC - 120V, other
ratings available, see ordering
scheme.
Insulation Resistance
Minimum of 100 Megohms at 500
VDC.
Dielectric Strength
UL, CSA: 1960 V 50/60 Hz for one
minute between all electrically
isolated terminals. D-Series circuit
breakers comply with the 8mm
spacing and 3750V 50/60 Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces and between
adjacent poles per Publications
EN 60950 and VDE 0805.
Resistance, Impedance Values from Line to Load Terminal
- based on Series Trip Circuit
Breaker
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
Trip Free
Trip Indication
10,000 ON-OFF operations @ 6
per minute; with rated Current
and Voltage.
All D-Series Circuit Breakers will
trip on overload, even when
actuator is forcibly held in the ON
position.
The operating actuator moves
positively to the OFF position
when an overload causes the
breaker to trip.
Physical
Number of Poles
Internal Circuit Config.
Weight
Standard Colors
Mounting
Rocker Type: 1-3; Handle Type:
1-4
Switch Only and Series Trip with
current or voltage trip coils.
Approximately 128 grams/pole
(Approximately 4.57 ounces/pole)
Housing - Black; Actuator - See
Ordering Scheme.
Mounts on a standard 35mm
Symmetrical DIN Rail (35 x 7.5 or
35 x 15mm per DIN EN5002).
Environmental
Designed and tested in accordance with requirements of
specification MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Pulse Tolerance Curves
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short
curves tested @ 90% of rated
current.
Vibration
Withstands 0.060” excursion from
10-55 Hz, and 10 Gs 55-500 Hz,
at rated current per Method 204C,
Test Condition A. Instantaneous
and ultra-short curves tested at
90% of rated current.
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 8098% RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature -40° C to +85° C
*Manufacturer reserves the right to change product specification without prior notice.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
D-Series Circuit Breaker - General Specifications | 3
Electrical Tables
Table A: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a
Component Supplementary Protector.
Table A Notes:
1
DC and 1Phase 277 V ratings are 1 or 2 poles breaking. Three phase ratings are 3 poles breaking.
2
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 150 A for 250V rating and 125 A for 277 and 480 V ratings.
3
UL recognition and CSA Acceptance at 480 volts refers to 3 and 4 pole versions, used only in a 3 phase WYE connected circuit or 2 pole versions connected with 2 poles breaking 1 phase and backed up with series fusing per note 2
Agency Certifications
UL Recognized
UL Standard 1077
UL Listed
UL Standard 508
Component Recognition Program
as Protectors, Supplementary
(Guide QVNU2, File E75596)
Switches, Industrial Control
(Guide NRNT2, File E148683)
CSA Accepted
Component Supplementary
Protector under Class 3215 30,
File 047848 0 000
CSA Standard C22.2 No. 235
VDE Certified
EN60934, VDE 0642 under File
No. 10537
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
4 | D-Series Handle & Rocker – Ordering Scheme
D A 3
1
Series
2
Actuator
3
Poles
B0
4
Circuit
10
5
Frequency
& Delay
1 SERIES
D
450
6
Current Rating
1 2 1
7
Terminal
8
Actuator
Color
9
Mounting/
Voltage
Handle2
A
Handle, one per pole
B
Handle, one per multipole unit
Visi-Rocker3
C
Indicate ON, vertical legend
D
Indicate ON, horizontal legend
E
Indicate ON, no legend (VDE approval not available with no legend)
F
Indicate OFF, vertical legend
G
Indicate OFF, horizontal legend
H
Indicate OFF, no legend (VDE approval not available with no legend)
Single Color Rocker3
J
Vertical legend
K
Horizontal legend
L
No legend (VDE approval not available with no legend)
CODE
AMPERES
020
025
030
050
075
080
085
210
215
220
225
230
235
240
245
250
255
260
265
270
275
0.020
0.025
0.030
0.050
0.075
0.080
0.085
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
280
285
410
512
413
414
415
517
420
522
425
527
430
532
435
436
440
445
547
450
455
460
465
470
572
475
480
485
490
495
610
710
611
711
612
712
613
614
615
616
617
618
0.800
0.850
1.000
1.250
1.300
1.400
1.500
1.750
2.000
2.250
2.500
2.750
3.000
3.250
3.500
3.600
4.000
4.500
4.750
5.000
5.500
J24
J48
K20
L40
19.000
20.000
21.000
22.000
23.000
24.000
25.000
26.000
27.000
28.000
29.000
30.000
32.000
35.000
40.000
45.000
50.000
24 AC, 20 AC
48 AC, 40 AC
120 AC, 65 AC
240 AC, 130 AC
7 TERMINAL
1
#10 Screw & Pressure Plate for Direct Wire Connection
2
#10 Screw without Pressure Plate
3 POLES
One
Two
Three
Four
4 CIRCUIT
Switch Only (No Coil)4
Series Trip (Current)
Series Trip (Voltage)
5 FREQUENCY & DELAY
03
105
11
12
14
16
205
21
22
24
619
620
621
622
623
624
625
626
627
628
629
630
632
635
640
645
650
6.000
6.500
7.000
7.250
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
OR VOLTAGE COIL (VOLTS, MIN. TRIP RATING)5
A06 6 DC, 5 DC
A48 48 DC, 40 DC
A12 12 DC, 10 DC
A65 65 DC, 55 DC
A18 18 DC, 15 DC
J06 6 AC, 5 AC
A24 24 DC, 20 DC
J12 12 AC, 10 AC
A32 32 DC, 25 DC
J18 18 AC, 15 AC
A0
B0
C0
10
Agency
Approval
7 CURRENT RATING (AMPERES)
2 ACTUATOR1
1
2
3
4
C
DC 50/60Hz, Switch Only
DC Instantaneous
DC Ultra Short
DC Short
DC Medium
DC Long
50/60Hz Instantaneous
50/60Hz Ultra Short
50/60Hz Short
50/60Hz Medium
26
32
34
36
426
446
466
526
546
566
50/60Hz Long
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short, Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
Notes:
1
Handle breakers available up to four poles. Rocker breakers available up to three poles.
2
Actuator Code:
A: Multi-pole units factory assembled with common handle tie.
B: Handle location as viewed from front of breaker:
2 pole - left pole
3 pole - center pole
4 pole - two handles at center poles
3
Multipole rocker breakers have one rocker per breaker, as viewed from the front of the
panel. Two pole - left pole. Three pole - center pole
4
≤ 30A, select Current Rating code 630. 31-50A, select Current Rating code 650.
5
Voltage coil only available with delay codes 10 & 20.
6
Available to 50A max with circuit code BO only.
7
Color shown is visi and legend with remainder of rocker black.
8
≥ 300V: Three pole breaker 3Ø or 2 pole breaker 1Ø, UL/CSA limited to 30 FLA max.
9
VDE Approval requires Dual (I-O, ON-OFF) or I-O markings
8 ACTUATOR COLOR & LEGEND
Actuator or
Visi-Color Marking:
Color
I-O ON-OFF Dual
White
A
B
1
Black
C
D
2
Red
F
G
3
Green
H
J
4
Blue
K
L
5
Yellow
M
N
6
Gray
P
Q
7
Orange
R
S
8
9 MOUNTING/VOLTAGE
MOUNTING STYLE
Threaded Insert
1
6-32 x 0.195 inches
8
C
6-32 X 0.195 inches
2
ISO M3 x 5mm
D8
ISO M3 x 5mm
Marking Color:
Single Color
Rocker/Handle
Black
White
White
White
White
Black
Black
Black
Visi-Rocker
(Actuator Black)7
White
N/A
Red
Green
Blue
Yellow
Gray
Orange
VOLTAGE
< 300
≥ 300
< 300
≥ 300
10 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
D9
VDE Certified, UL Recognized & CSA Accepted
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
D-Series – Circuit & Terminal Diagram | 5
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
6 | D-Series Rocker – Form & Fit Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
3
Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON.
4
For pole orientation with horizontal legend, rotate front view clockwise 90°.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
D-Series – Form & Fit Drawings | 7
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.010 [.25] unless otherwise specified.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
East Region Sales Office, CT • [email protected]
Midwest Region Sales Office, IL • [email protected]
West Region Sales Office, CA • [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China • [email protected]
Shanghai, China • [email protected]
Pune, India • [email protected]
Kaohsiung, Taiwan • [email protected]
Yokohama, Japan • [email protected]
Europe/Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: [email protected]
GmbH, Germany • [email protected]
SAS, France • [email protected]
REV_CB_D_01_2014