For heavy-duty applications, contactors designed to switch up to 2750 amps Protection and intelligence combined ■ The LT6-P electronic multifunction protection relay is ideally suited to high performance applications. It provides protection for your motors in virtually any application or operating condition. ■ It enables automatic control of different methods of starting: ■ ■ ■ CV1 Contactors ■ ■ ■ ■ ■ For loads up to 950 amps inductive, 1000 amps resistive Voltage up to 660 VAC or 440 VDC Frequency up to 200 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles ■ All the functionalities are programmable with parameters entered locally or using a PC software. ■ It integrates into all the most complex automation systems through its communication functions on UNITELWAY®, JBUS™, MODBUS® protocols. Thermal Overload Relays from 6 to 2750 A Manual Starter and Protector The TELEMECANIQUE GV2 and GV3 devices incorporate a manual disconnect, overload relay and instantaneous magnetic trip mechanism in one compact device. They can be used as standalone manual starters or to protect each branch circuit of a group motor installation. in hard ambient conditions: high temperature, dust, humidity with severe duty: fast operating cycles, use of DC injection braking. cross-line (reversing or non-reversing) star/delta 2-speed ■ Contactors and Request document 8539CT9201R6/97 The LT3-S thermistor relay provides complementary protection by direct measurement of the temperature of motors equipped with PTC thermistor probes, for operation: ■ ■ INTEGRAL™ Self-Protected Starters TELEMECANIQUE ® INTEGRAL self-protected starters combine circuit breaker, contactor and dual function overload relay for coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated protection. INTEGRAL starters can reduce panel space requirements by 40 to 60%. 18A, 32A and 63A models are available. Protect your motor from damaging over-temperatures Request document 252OCT9501R6/97 Enclosed IEC Starters D-Line starters and INTEGRAL self-protected starters are available in metal NEMA Type 1 and 12 enclosures. These enclosed devices utilize INSTAKIT ™ components for the addition of cover mounted pilot devices. INSTAKIT components are pre-wired control operator kits that use a universal connector for quick, easy installation. Request following documents 9502HO9401R0996 - INSTAKIT pre-wired starter access 9502HO9402R0996 - D-Line non-combination starters 9502HO9403R0996 - INTEGRAL starters 8502CT0101 - IEC SMCE contactors and starters 8502BR0102-TeSys-The New D-LINE D-Line, K-Line and F-Line contactors and overload relays are the largest selling motor starting and protection devices in the world. They offer starting for motors up to 800 hp at 480 AC volts and switching of resistive loads up to 1350 amps. They are UL-listed, CSA-certified and CE-marked for use in North America and around the world. CV3 Contactors ■ ■ ■ ■ ■ For loads up to 1800 amps inductive, 2750 amps resistive Voltage up to 1000 VAC or 1500 VDC Frequency up to 400 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles Visit the Square D web site at www.SquareD.com Order Number 8502BR0101 Printed in U.S.A. © 2001 Schneider Electric All Rights Reserved Schneider Electric Brands Get more with the world’s Power & Control specialist. Front mounted additional blocks Coil Suffixes ■■ ▲▲ Low Consumption DC DC Hz 50/60 50* 60* 24 V 48 V 72 V 110 V 120 V 208 V 220 V 230 V 240 V 250 V 380 V 400 V 415 V 440 V B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7 B5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 B6 BD E6 ED SD F6 FD G6 L6 M6 MD U6 UD Q6 R6 RD* ▼▼ 1 2 4 3 2 1 - LA1-KN20 LA1-KN11 LA1-KN02 1 2 3 4 LA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04 2 1 - 1 2 NO NC NC NO NO NC LAD-N20 LAD-N11 LAD-N02 4 3 2 1 - 1 2 3 4 1 LAD-N40 LAD-N31 LAD-N22 LAD-N13 LAD-N04 1 1 NO 1 LAD-C22 2 LA1-DX20 2 2 2 1 1 1 2 1 40/400 FW FW MW MW MW 1 2 F M P U Q V N R QW QW QW QW Contactors 220/230 380/400 415 V 500 V 660/690 1000 V 200 V 230 V 460/480 575 V V V V V A A AWG kW kW kW kW kW kW HP HP HP HP AC DC Low Consumption DC (< 2.4 W) A1 A2 6 20 10 1.5 2.2 2.2 3 3 1.5 3 3 LC1-K06 ● ● ■ ■ LP1-K06 ● ● ■ ■ LP4-K06 ● ● 3 10 01 Part number suffixes to specify power pole/ auxiliary contact configuration 01 004 008 0.11 Standard overload relays 0.16 LR2-K0301 0.36 0.54 1.2 9 25 10 2.2 4 4 5.5 5.5 2 5 7.5 LC1-D09 ■ ■ LC1-D09 ■ ■ LC1-D09 12 25 10 3 5.5 5.5 7.5 7.5 3 7.5 10 LC1-D12 LC1-D02 LC1-D02 18 32 8 4 7.5 9 10 10 5 10 15 LC1-D18 LC1-D18 LC1-D18 ■■ ■■ 25 40 6 5.5 1111 11 15 15 7.5 15 20 LC1-D25 LC1-D25 LC1-D25 ■■ ■■ 32 50 6 7.5 15 15 18.5 18.5 10 20 30 ■■ ■■ 40 60 3 11 18.5 22 22 30 10 30 30 50 80 3 15 22 25 30 33 15 40 40 65 80 3 18.5 30 37 37 37 20 50 50 80 125 2 22 37 45 55 45 30 60 60 LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ 10 01 3.7 10 LR2-K0320 0.25 LRD-02 0.4 0.63 LRD-03 LRD-04 1 LRD-05 1.6 LRD-06 2.5 LRD-07 4 25 LR2-K0307 30 4 6 7 10 LRD-10 12 18 LRD-08 LRD-14 23 LRD-21 48 65 LRD-3355 LRD-3359 LRD-3353 LRD-3357 23 11.5 40 LRD-3322 3.7 8 14 0.16 LRD-01 LR2-K0304 LR2-K0308 LR2-K0314 0.1 1.2 2.6 5.5 LR2-K0312 Class 10 0.8 1.8 17 0.36 LR2-K0301 LR2-K0305 LR2-K0307 Direct mounting on the contactor 0.23 LR2-K0302 LR2-K0304 Multifunction overload relays 10 01 12 20 10 3 5.5 5.5 4 4 3 7.5 10 LC1-K12● ● ■ ■ LC1-K12● ● ■ ■ LP4-K12 ● ● 3 004 008 10 00 9 20 10 2.2 4 4 4 4 3 5 5 LC1-K09 ● ● ■ ■ LP1-K09 ● ● ■ ■ LP4-K09 ● ● 3 32 37 55 32 LRD-32 50 70 80 104 LRD-3361 LRD-3365 LR2-K0312 12 LRD-12 18 LR2-K0321 5.5 LRD-16 8 9 LRD-22 13 0.2 A 17 LRD-35 25 30 LRD-3363 5A LT6-P0M005FM 63 38 25 A LT6-P0M025FM (1) Except LC1-D115, LC1-D150 (2) Only LCI, LPI (3) For LP4-D For more information refer to publication 8502CT0101 80 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ Max. inductive current AC3 Max. resistive current AC1 Max. wire size 11 LA1-DY20 1 - 30s NC LAD-S2 NO NO 0.1 - 3s LAD-T0 1 - 30s LAD-T2 10 - 180s LAD-T4 NC 0.1 - 3s LAD-R0 1 - 30s LAD-R2 10 - 180s LAD-R4 LAD-8N11(1) LAD-8N20(1) LAD-8N02(1) *Except K Maximum 3 phase horsepower ratings 2 NO ▼ …400 Maximum 3 phase power ratings per IEC 947-4 2 LA1-DZ40 LA1-DZ31 NC NO NC AC/DC AC BL EL SL NO NO NO NC 115 250 250 MCM 30 55 59 75 80 75 40 75 100 150 250 250 MCM 40 75 80 90 100 90 50 100 125 LC1-D115 ■ ■ LC1-D150 7 LC1-D115 LC1-D150 ■ ■ ■■ 60 100 LR9-D5367 LR9-D5369 90 150 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■ AC 2 1 - NO NC 115 175 Ø 30 55 59 75 80 65 30 40 75 100 150 200 3/Ø 40 7755 80 90 100 65 40 50 100 125 LC1-F115 ■ ■ 185 200 3/Ø 55 9900 100 110 110 100 50 60 125 150 LC1-F150 ■ ■ 30 LC1-F185 ■ ■ 225 200 300 MCM 63 110 110 129 129 100 60 75 150 150 265 285 300 MCM 75 132 140 160 160 147 60 75 150 200 330 360 300 MCM 100 160 180 200 220 160 75 100 200 250 400 420 600 MCM 110 200 220 257 280 185 100 125 250 300 LC1-F225 ■ ■ LC1-F265 ■ ■ LC1-F330 ■ ■ LC1-F400 ■ ■ 132 50 LR9-F5357 500 700 2 x 600 MCM 147 250 280 355 335 335 150 200 400 500 LC1-F500 ■ ■ 630 1000 3 x 600 MCM 200 335 375 400 450 450 250 300 600 800 800 1000 3 x 600 MCM 250 450 450 450 475 450 450 800 900 LC1-F630 ■ ■ LC1-F800 ▼ ▼ 220 LR9-F5371 200 LR9-F5363 48 80 60 330 LR9-F7375 100 LR9-F7379 LR9-F5367 300 500 LR9-F5369 LR9-F7381 90 LT6-P0M005FM + LTC-CT•001 150 1A 5A 380 630 630 780 1350 4 x 750 MCM 450 900 900 LC1-F780 ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ NO NC NO NC NO NC Built-in auxiliary contacts 750 1000 800 1250 2 x 80mm x 5mm55552 x 80mm x 5mm5555 220 280 400 500 425 590 500 600 560 670 530 530 LC1BL3 ❍▼ 22 LC1BM3 ❍▼ 22 2 2 1500 2000 3 x 100mm x 5mm5555 425 750 800 750 750 670 LC1BP3 ❍▼ 22 1800 2750 4 x 100mm x 5mm5555 500 900 900 900 900 750 LC1BR3 ❍▼ A A AWG kW kW kW kW kW kW HP HP HP HP AC DC 22 1A + LR2D1305 5A + LR2D1310 2750 A 2750 A Front mounted additional blocks Coil Suffixes ■■ ▲▲ Low Consumption DC DC Hz 50/60 50* 60* 24 V 48 V 72 V 110 V 120 V 208 V 220 V 230 V 240 V 250 V 380 V 400 V 415 V 440 V B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7 B5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 B6 BD E6 ED SD F6 FD G6 L6 M6 MD U6 UD Q6 R6 RD* ▼▼ 1 2 4 3 2 1 - LA1-KN20 LA1-KN11 LA1-KN02 1 2 3 4 LA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04 2 1 - 1 2 NO NC NC NO NO NC LAD-N20 LAD-N11 LAD-N02 4 3 2 1 - 1 2 3 4 1 LAD-N40 LAD-N31 LAD-N22 LAD-N13 LAD-N04 1 1 NO 1 LAD-C22 2 LA1-DX20 2 2 2 1 1 1 2 1 40/400 FW FW MW MW MW 1 2 F M P U Q V N R QW QW QW QW Contactors 220/230 380/400 415 V 500 V 660/690 1000 V 200 V 230 V 460/480 575 V V V V V A A AWG kW kW kW kW kW kW HP HP HP HP AC DC Low Consumption DC (< 2.4 W) A1 A2 6 20 10 1.5 2.2 2.2 3 3 1.5 3 3 LC1-K06 ● ● ■ ■ LP1-K06 ● ● ■ ■ LP4-K06 ● ● 3 10 01 Part number suffixes to specify power pole/ auxiliary contact configuration 01 004 008 0.11 Standard overload relays 0.16 LR2-K0301 0.36 0.54 1.2 9 25 10 2.2 4 4 5.5 5.5 2 5 7.5 LC1-D09 ■ ■ LC1-D09 ■ ■ LC1-D09 12 25 10 3 5.5 5.5 7.5 7.5 3 7.5 10 LC1-D12 LC1-D02 LC1-D02 18 32 8 4 7.5 9 10 10 5 10 15 LC1-D18 LC1-D18 LC1-D18 ■■ ■■ 25 40 6 5.5 1111 11 15 15 7.5 15 20 LC1-D25 LC1-D25 LC1-D25 ■■ ■■ 32 50 6 7.5 15 15 18.5 18.5 10 20 30 ■■ ■■ 40 60 3 11 18.5 22 22 30 10 30 30 50 80 3 15 22 25 30 33 15 40 40 65 80 3 18.5 30 37 37 37 20 50 50 80 125 2 22 37 45 55 45 30 60 60 LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ 10 01 3.7 10 LR2-K0320 0.25 LRD-02 0.4 0.63 LRD-03 LRD-04 1 LRD-05 1.6 LRD-06 2.5 LRD-07 4 25 LR2-K0307 30 4 6 7 10 LRD-10 12 18 LRD-08 LRD-14 23 LRD-21 48 65 LRD-3355 LRD-3359 LRD-3353 LRD-3357 23 11.5 40 LRD-3322 3.7 8 14 0.16 LRD-01 LR2-K0304 LR2-K0308 LR2-K0314 0.1 1.2 2.6 5.5 LR2-K0312 Class 10 0.8 1.8 17 0.36 LR2-K0301 LR2-K0305 LR2-K0307 Direct mounting on the contactor 0.23 LR2-K0302 LR2-K0304 Multifunction overload relays 10 01 12 20 10 3 5.5 5.5 4 4 3 7.5 10 LC1-K12● ● ■ ■ LC1-K12● ● ■ ■ LP4-K12 ● ● 3 004 008 10 00 9 20 10 2.2 4 4 4 4 3 5 5 LC1-K09 ● ● ■ ■ LP1-K09 ● ● ■ ■ LP4-K09 ● ● 3 32 37 55 32 LRD-32 50 70 80 104 LRD-3361 LRD-3365 LR2-K0312 12 LRD-12 18 LR2-K0321 5.5 LRD-16 8 9 LRD-22 13 0.2 A 17 LRD-35 25 30 LRD-3363 5A LT6-P0M005FM 63 38 25 A LT6-P0M025FM (1) Except LC1-D115, LC1-D150 (2) Only LCI, LPI (3) For LP4-D For more information refer to publication 8502CT0101 80 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ Max. inductive current AC3 Max. resistive current AC1 Max. wire size 11 LA1-DY20 1 - 30s NC LAD-S2 NO NO 0.1 - 3s LAD-T0 1 - 30s LAD-T2 10 - 180s LAD-T4 NC 0.1 - 3s LAD-R0 1 - 30s LAD-R2 10 - 180s LAD-R4 LAD-8N11(1) LAD-8N20(1) LAD-8N02(1) *Except K Maximum 3 phase horsepower ratings 2 NO ▼ …400 Maximum 3 phase power ratings per IEC 947-4 2 LA1-DZ40 LA1-DZ31 NC NO NC AC/DC AC BL EL SL NO NO NO NC 115 250 250 MCM 30 55 59 75 80 75 40 75 100 150 250 250 MCM 40 75 80 90 100 90 50 100 125 LC1-D115 ■ ■ LC1-D150 7 LC1-D115 LC1-D150 ■ ■ ■■ 60 100 LR9-D5367 LR9-D5369 90 150 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■ AC 2 1 - NO NC 115 175 Ø 30 55 59 75 80 65 30 40 75 100 150 200 3/Ø 40 7755 80 90 100 65 40 50 100 125 LC1-F115 ■ ■ 185 200 3/Ø 55 9900 100 110 110 100 50 60 125 150 LC1-F150 ■ ■ 30 LC1-F185 ■ ■ 225 200 300 MCM 63 110 110 129 129 100 60 75 150 150 265 285 300 MCM 75 132 140 160 160 147 60 75 150 200 330 360 300 MCM 100 160 180 200 220 160 75 100 200 250 400 420 600 MCM 110 200 220 257 280 185 100 125 250 300 LC1-F225 ■ ■ LC1-F265 ■ ■ LC1-F330 ■ ■ LC1-F400 ■ ■ 132 50 LR9-F5357 500 700 2 x 600 MCM 147 250 280 355 335 335 150 200 400 500 LC1-F500 ■ ■ 630 1000 3 x 600 MCM 200 335 375 400 450 450 250 300 600 800 800 1000 3 x 600 MCM 250 450 450 450 475 450 450 800 900 LC1-F630 ■ ■ LC1-F800 ▼ ▼ 220 LR9-F5371 200 LR9-F5363 48 80 60 330 LR9-F7375 100 LR9-F7379 LR9-F5367 300 500 LR9-F5369 LR9-F7381 90 LT6-P0M005FM + LTC-CT•001 150 1A 5A 380 630 630 780 1350 4 x 750 MCM 450 900 900 LC1-F780 ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ NO NC NO NC NO NC Built-in auxiliary contacts 750 1000 800 1250 2 x 80mm x 5mm55552 x 80mm x 5mm5555 220 280 400 500 425 590 500 600 560 670 530 530 LC1BL3 ❍▼ 22 LC1BM3 ❍▼ 22 2 2 1500 2000 3 x 100mm x 5mm5555 425 750 800 750 750 670 LC1BP3 ❍▼ 22 1800 2750 4 x 100mm x 5mm5555 500 900 900 900 900 750 LC1BR3 ❍▼ A A AWG kW kW kW kW kW kW HP HP HP HP AC DC 22 1A + LR2D1305 5A + LR2D1310 2750 A 2750 A Front mounted additional blocks Coil Suffixes ■■ ▲▲ Low Consumption DC DC Hz 50/60 50* 60* 24 V 48 V 72 V 110 V 120 V 208 V 220 V 230 V 240 V 250 V 380 V 400 V 415 V 440 V B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7 B5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 B6 BD E6 ED SD F6 FD G6 L6 M6 MD U6 UD Q6 R6 RD* ▼▼ 1 2 4 3 2 1 - LA1-KN20 LA1-KN11 LA1-KN02 1 2 3 4 LA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04 2 1 - 1 2 NO NC NC NO NO NC LAD-N20 LAD-N11 LAD-N02 4 3 2 1 - 1 2 3 4 1 LAD-N40 LAD-N31 LAD-N22 LAD-N13 LAD-N04 1 1 NO 1 LAD-C22 2 LA1-DX20 2 2 2 1 1 1 2 1 40/400 FW FW MW MW MW 1 2 F M P U Q V N R QW QW QW QW Contactors 220/230 380/400 415 V 500 V 660/690 1000 V 200 V 230 V 460/480 575 V V V V V A A AWG kW kW kW kW kW kW HP HP HP HP AC DC Low Consumption DC (< 2.4 W) A1 A2 6 20 10 1.5 2.2 2.2 3 3 1.5 3 3 LC1-K06 ● ● ■ ■ LP1-K06 ● ● ■ ■ LP4-K06 ● ● 3 10 01 Part number suffixes to specify power pole/ auxiliary contact configuration 01 004 008 0.11 Standard overload relays 0.16 LR2-K0301 0.36 0.54 1.2 9 25 10 2.2 4 4 5.5 5.5 2 5 7.5 LC1-D09 ■ ■ LC1-D09 ■ ■ LC1-D09 12 25 10 3 5.5 5.5 7.5 7.5 3 7.5 10 LC1-D12 LC1-D02 LC1-D02 18 32 8 4 7.5 9 10 10 5 10 15 LC1-D18 LC1-D18 LC1-D18 ■■ ■■ 25 40 6 5.5 1111 11 15 15 7.5 15 20 LC1-D25 LC1-D25 LC1-D25 ■■ ■■ 32 50 6 7.5 15 15 18.5 18.5 10 20 30 ■■ ■■ 40 60 3 11 18.5 22 22 30 10 30 30 50 80 3 15 22 25 30 33 15 40 40 65 80 3 18.5 30 37 37 37 20 50 50 80 125 2 22 37 45 55 45 30 60 60 LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ 10 01 3.7 10 LR2-K0320 0.25 LRD-02 0.4 0.63 LRD-03 LRD-04 1 LRD-05 1.6 LRD-06 2.5 LRD-07 4 25 LR2-K0307 30 4 6 7 10 LRD-10 12 18 LRD-08 LRD-14 23 LRD-21 48 65 LRD-3355 LRD-3359 LRD-3353 LRD-3357 23 11.5 40 LRD-3322 3.7 8 14 0.16 LRD-01 LR2-K0304 LR2-K0308 LR2-K0314 0.1 1.2 2.6 5.5 LR2-K0312 Class 10 0.8 1.8 17 0.36 LR2-K0301 LR2-K0305 LR2-K0307 Direct mounting on the contactor 0.23 LR2-K0302 LR2-K0304 Multifunction overload relays 10 01 12 20 10 3 5.5 5.5 4 4 3 7.5 10 LC1-K12● ● ■ ■ LC1-K12● ● ■ ■ LP4-K12 ● ● 3 004 008 10 00 9 20 10 2.2 4 4 4 4 3 5 5 LC1-K09 ● ● ■ ■ LP1-K09 ● ● ■ ■ LP4-K09 ● ● 3 32 37 55 32 LRD-32 50 70 80 104 LRD-3361 LRD-3365 LR2-K0312 12 LRD-12 18 LR2-K0321 5.5 LRD-16 8 9 LRD-22 13 0.2 A 17 LRD-35 25 30 LRD-3363 5A LT6-P0M005FM 63 38 25 A LT6-P0M025FM (1) Except LC1-D115, LC1-D150 (2) Only LCI, LPI (3) For LP4-D For more information refer to publication 8502CT0101 80 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ Max. inductive current AC3 Max. resistive current AC1 Max. wire size 11 LA1-DY20 1 - 30s NC LAD-S2 NO NO 0.1 - 3s LAD-T0 1 - 30s LAD-T2 10 - 180s LAD-T4 NC 0.1 - 3s LAD-R0 1 - 30s LAD-R2 10 - 180s LAD-R4 LAD-8N11(1) LAD-8N20(1) LAD-8N02(1) *Except K Maximum 3 phase horsepower ratings 2 NO ▼ …400 Maximum 3 phase power ratings per IEC 947-4 2 LA1-DZ40 LA1-DZ31 NC NO NC AC/DC AC BL EL SL NO NO NO NC 115 250 250 MCM 30 55 59 75 80 75 40 75 100 150 250 250 MCM 40 75 80 90 100 90 50 100 125 LC1-D115 ■ ■ LC1-D150 7 LC1-D115 LC1-D150 ■ ■ ■■ 60 100 LR9-D5367 LR9-D5369 90 150 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■ AC 2 1 - NO NC 115 175 Ø 30 55 59 75 80 65 30 40 75 100 150 200 3/Ø 40 7755 80 90 100 65 40 50 100 125 LC1-F115 ■ ■ 185 200 3/Ø 55 9900 100 110 110 100 50 60 125 150 LC1-F150 ■ ■ 30 LC1-F185 ■ ■ 225 200 300 MCM 63 110 110 129 129 100 60 75 150 150 265 285 300 MCM 75 132 140 160 160 147 60 75 150 200 330 360 300 MCM 100 160 180 200 220 160 75 100 200 250 400 420 600 MCM 110 200 220 257 280 185 100 125 250 300 LC1-F225 ■ ■ LC1-F265 ■ ■ LC1-F330 ■ ■ LC1-F400 ■ ■ 132 50 LR9-F5357 500 700 2 x 600 MCM 147 250 280 355 335 335 150 200 400 500 LC1-F500 ■ ■ 630 1000 3 x 600 MCM 200 335 375 400 450 450 250 300 600 800 800 1000 3 x 600 MCM 250 450 450 450 475 450 450 800 900 LC1-F630 ■ ■ LC1-F800 ▼ ▼ 220 LR9-F5371 200 LR9-F5363 48 80 60 330 LR9-F7375 100 LR9-F7379 LR9-F5367 300 500 LR9-F5369 LR9-F7381 90 LT6-P0M005FM + LTC-CT•001 150 1A 5A 380 630 630 780 1350 4 x 750 MCM 450 900 900 LC1-F780 ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ NO NC NO NC NO NC Built-in auxiliary contacts 750 1000 800 1250 2 x 80mm x 5mm55552 x 80mm x 5mm5555 220 280 400 500 425 590 500 600 560 670 530 530 LC1BL3 ❍▼ 22 LC1BM3 ❍▼ 22 2 2 1500 2000 3 x 100mm x 5mm5555 425 750 800 750 750 670 LC1BP3 ❍▼ 22 1800 2750 4 x 100mm x 5mm5555 500 900 900 900 900 750 LC1BR3 ❍▼ A A AWG kW kW kW kW kW kW HP HP HP HP AC DC 22 1A + LR2D1305 5A + LR2D1310 2750 A 2750 A Front mounted additional blocks Coil Suffixes ■■ ▲▲ Low Consumption DC DC Hz 50/60 50* 60* 24 V 48 V 72 V 110 V 120 V 208 V 220 V 230 V 240 V 250 V 380 V 400 V 415 V 440 V B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7 B5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 B6 BD E6 ED SD F6 FD G6 L6 M6 MD U6 UD Q6 R6 RD* ▼▼ 1 2 4 3 2 1 - LA1-KN20 LA1-KN11 LA1-KN02 1 2 3 4 LA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04 2 1 - 1 2 NO NC NC NO NO NC LAD-N20 LAD-N11 LAD-N02 4 3 2 1 - 1 2 3 4 1 LAD-N40 LAD-N31 LAD-N22 LAD-N13 LAD-N04 1 1 NO 1 LAD-C22 2 LA1-DX20 2 2 2 1 1 1 2 1 40/400 FW FW MW MW MW 1 2 F M P U Q V N R QW QW QW QW Contactors 220/230 380/400 415 V 500 V 660/690 1000 V 200 V 230 V 460/480 575 V V V V V A A AWG kW kW kW kW kW kW HP HP HP HP AC DC Low Consumption DC (< 2.4 W) A1 A2 6 20 10 1.5 2.2 2.2 3 3 1.5 3 3 LC1-K06 ● ● ■ ■ LP1-K06 ● ● ■ ■ LP4-K06 ● ● 3 10 01 Part number suffixes to specify power pole/ auxiliary contact configuration 01 004 008 0.11 Standard overload relays 0.16 LR2-K0301 0.36 0.54 1.2 9 25 10 2.2 4 4 5.5 5.5 2 5 7.5 LC1-D09 ■ ■ LC1-D09 ■ ■ LC1-D09 12 25 10 3 5.5 5.5 7.5 7.5 3 7.5 10 LC1-D12 LC1-D02 LC1-D02 18 32 8 4 7.5 9 10 10 5 10 15 LC1-D18 LC1-D18 LC1-D18 ■■ ■■ 25 40 6 5.5 1111 11 15 15 7.5 15 20 LC1-D25 LC1-D25 LC1-D25 ■■ ■■ 32 50 6 7.5 15 15 18.5 18.5 10 20 30 ■■ ■■ 40 60 3 11 18.5 22 22 30 10 30 30 50 80 3 15 22 25 30 33 15 40 40 65 80 3 18.5 30 37 37 37 20 50 50 80 125 2 22 37 45 55 45 30 60 60 LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ 10 01 3.7 10 LR2-K0320 0.25 LRD-02 0.4 0.63 LRD-03 LRD-04 1 LRD-05 1.6 LRD-06 2.5 LRD-07 4 25 LR2-K0307 30 4 6 7 10 LRD-10 12 18 LRD-08 LRD-14 23 LRD-21 48 65 LRD-3355 LRD-3359 LRD-3353 LRD-3357 23 11.5 40 LRD-3322 3.7 8 14 0.16 LRD-01 LR2-K0304 LR2-K0308 LR2-K0314 0.1 1.2 2.6 5.5 LR2-K0312 Class 10 0.8 1.8 17 0.36 LR2-K0301 LR2-K0305 LR2-K0307 Direct mounting on the contactor 0.23 LR2-K0302 LR2-K0304 Multifunction overload relays 10 01 12 20 10 3 5.5 5.5 4 4 3 7.5 10 LC1-K12● ● ■ ■ LC1-K12● ● ■ ■ LP4-K12 ● ● 3 004 008 10 00 9 20 10 2.2 4 4 4 4 3 5 5 LC1-K09 ● ● ■ ■ LP1-K09 ● ● ■ ■ LP4-K09 ● ● 3 32 37 55 32 LRD-32 50 70 80 104 LRD-3361 LRD-3365 LR2-K0312 12 LRD-12 18 LR2-K0321 5.5 LRD-16 8 9 LRD-22 13 0.2 A 17 LRD-35 25 30 LRD-3363 5A LT6-P0M005FM 63 38 25 A LT6-P0M025FM (1) Except LC1-D115, LC1-D150 (2) Only LCI, LPI (3) For LP4-D For more information refer to publication 8502CT0101 80 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ Max. inductive current AC3 Max. resistive current AC1 Max. wire size 11 LA1-DY20 1 - 30s NC LAD-S2 NO NO 0.1 - 3s LAD-T0 1 - 30s LAD-T2 10 - 180s LAD-T4 NC 0.1 - 3s LAD-R0 1 - 30s LAD-R2 10 - 180s LAD-R4 LAD-8N11(1) LAD-8N20(1) LAD-8N02(1) *Except K Maximum 3 phase horsepower ratings 2 NO ▼ …400 Maximum 3 phase power ratings per IEC 947-4 2 LA1-DZ40 LA1-DZ31 NC NO NC AC/DC AC BL EL SL NO NO NO NC 115 250 250 MCM 30 55 59 75 80 75 40 75 100 150 250 250 MCM 40 75 80 90 100 90 50 100 125 LC1-D115 ■ ■ LC1-D150 7 LC1-D115 LC1-D150 ■ ■ ■■ 60 100 LR9-D5367 LR9-D5369 90 150 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■ AC 2 1 - NO NC 115 175 Ø 30 55 59 75 80 65 30 40 75 100 150 200 3/Ø 40 7755 80 90 100 65 40 50 100 125 LC1-F115 ■ ■ 185 200 3/Ø 55 9900 100 110 110 100 50 60 125 150 LC1-F150 ■ ■ 30 LC1-F185 ■ ■ 225 200 300 MCM 63 110 110 129 129 100 60 75 150 150 265 285 300 MCM 75 132 140 160 160 147 60 75 150 200 330 360 300 MCM 100 160 180 200 220 160 75 100 200 250 400 420 600 MCM 110 200 220 257 280 185 100 125 250 300 LC1-F225 ■ ■ LC1-F265 ■ ■ LC1-F330 ■ ■ LC1-F400 ■ ■ 132 50 LR9-F5357 500 700 2 x 600 MCM 147 250 280 355 335 335 150 200 400 500 LC1-F500 ■ ■ 630 1000 3 x 600 MCM 200 335 375 400 450 450 250 300 600 800 800 1000 3 x 600 MCM 250 450 450 450 475 450 450 800 900 LC1-F630 ■ ■ LC1-F800 ▼ ▼ 220 LR9-F5371 200 LR9-F5363 48 80 60 330 LR9-F7375 100 LR9-F7379 LR9-F5367 300 500 LR9-F5369 LR9-F7381 90 LT6-P0M005FM + LTC-CT•001 150 1A 5A 380 630 630 780 1350 4 x 750 MCM 450 900 900 LC1-F780 ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ NO NC NO NC NO NC Built-in auxiliary contacts 750 1000 800 1250 2 x 80mm x 5mm55552 x 80mm x 5mm5555 220 280 400 500 425 590 500 600 560 670 530 530 LC1BL3 ❍▼ 22 LC1BM3 ❍▼ 22 2 2 1500 2000 3 x 100mm x 5mm5555 425 750 800 750 750 670 LC1BP3 ❍▼ 22 1800 2750 4 x 100mm x 5mm5555 500 900 900 900 900 750 LC1BR3 ❍▼ A A AWG kW kW kW kW kW kW HP HP HP HP AC DC 22 1A + LR2D1305 5A + LR2D1310 2750 A 2750 A Front mounted additional blocks Coil Suffixes ■■ ▲▲ Low Consumption DC DC Hz 50/60 50* 60* 24 V 48 V 72 V 110 V 120 V 208 V 220 V 230 V 240 V 250 V 380 V 400 V 415 V 440 V B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7 B5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 B6 BD E6 ED SD F6 FD G6 L6 M6 MD U6 UD Q6 R6 RD* ▼▼ 1 2 4 3 2 1 - LA1-KN20 LA1-KN11 LA1-KN02 1 2 3 4 LA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04 2 1 - 1 2 NO NC NC NO NO NC LAD-N20 LAD-N11 LAD-N02 4 3 2 1 - 1 2 3 4 1 LAD-N40 LAD-N31 LAD-N22 LAD-N13 LAD-N04 1 1 NO 1 LAD-C22 2 LA1-DX20 2 2 2 1 1 1 2 1 40/400 FW FW MW MW MW 1 2 F M P U Q V N R QW QW QW QW Contactors 220/230 380/400 415 V 500 V 660/690 1000 V 200 V 230 V 460/480 575 V V V V V A A AWG kW kW kW kW kW kW HP HP HP HP AC DC Low Consumption DC (< 2.4 W) A1 A2 6 20 10 1.5 2.2 2.2 3 3 1.5 3 3 LC1-K06 ● ● ■ ■ LP1-K06 ● ● ■ ■ LP4-K06 ● ● 3 10 01 Part number suffixes to specify power pole/ auxiliary contact configuration 01 004 008 0.11 Standard overload relays 0.16 LR2-K0301 0.36 0.54 1.2 9 25 10 2.2 4 4 5.5 5.5 2 5 7.5 LC1-D09 ■ ■ LC1-D09 ■ ■ LC1-D09 12 25 10 3 5.5 5.5 7.5 7.5 3 7.5 10 LC1-D12 LC1-D02 LC1-D02 18 32 8 4 7.5 9 10 10 5 10 15 LC1-D18 LC1-D18 LC1-D18 ■■ ■■ 25 40 6 5.5 1111 11 15 15 7.5 15 20 LC1-D25 LC1-D25 LC1-D25 ■■ ■■ 32 50 6 7.5 15 15 18.5 18.5 10 20 30 ■■ ■■ 40 60 3 11 18.5 22 22 30 10 30 30 50 80 3 15 22 25 30 33 15 40 40 65 80 3 18.5 30 37 37 37 20 50 50 80 125 2 22 37 45 55 45 30 60 60 LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ LC1-D32 ■■ LC1-D40 ■■ LC1-D50 ■■ LC1-D65 ■■ LC1-D80 ■■ 10 01 3.7 10 LR2-K0320 0.25 LRD-02 0.4 0.63 LRD-03 LRD-04 1 LRD-05 1.6 LRD-06 2.5 LRD-07 4 25 LR2-K0307 30 4 6 7 10 LRD-10 12 18 LRD-08 LRD-14 23 LRD-21 48 65 LRD-3355 LRD-3359 LRD-3353 LRD-3357 23 11.5 40 LRD-3322 3.7 8 14 0.16 LRD-01 LR2-K0304 LR2-K0308 LR2-K0314 0.1 1.2 2.6 5.5 LR2-K0312 Class 10 0.8 1.8 17 0.36 LR2-K0301 LR2-K0305 LR2-K0307 Direct mounting on the contactor 0.23 LR2-K0302 LR2-K0304 Multifunction overload relays 10 01 12 20 10 3 5.5 5.5 4 4 3 7.5 10 LC1-K12● ● ■ ■ LC1-K12● ● ■ ■ LP4-K12 ● ● 3 004 008 10 00 9 20 10 2.2 4 4 4 4 3 5 5 LC1-K09 ● ● ■ ■ LP1-K09 ● ● ■ ■ LP4-K09 ● ● 3 32 37 55 32 LRD-32 50 70 80 104 LRD-3361 LRD-3365 LR2-K0312 12 LRD-12 18 LR2-K0321 5.5 LRD-16 8 9 LRD-22 13 0.2 A 17 LRD-35 25 30 LRD-3363 5A LT6-P0M005FM 63 38 25 A LT6-P0M025FM (1) Except LC1-D115, LC1-D150 (2) Only LCI, LPI (3) For LP4-D For more information refer to publication 8502CT0101 80 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ Max. inductive current AC3 Max. resistive current AC1 Max. wire size 11 LA1-DY20 1 - 30s NC LAD-S2 NO NO 0.1 - 3s LAD-T0 1 - 30s LAD-T2 10 - 180s LAD-T4 NC 0.1 - 3s LAD-R0 1 - 30s LAD-R2 10 - 180s LAD-R4 LAD-8N11(1) LAD-8N20(1) LAD-8N02(1) *Except K Maximum 3 phase horsepower ratings 2 NO ▼ …400 Maximum 3 phase power ratings per IEC 947-4 2 LA1-DZ40 LA1-DZ31 NC NO NC AC/DC AC BL EL SL NO NO NO NC 115 250 250 MCM 30 55 59 75 80 75 40 75 100 150 250 250 MCM 40 75 80 90 100 90 50 100 125 LC1-D115 ■ ■ LC1-D150 7 LC1-D115 LC1-D150 ■ ■ ■■ 60 100 LR9-D5367 LR9-D5369 90 150 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■ AC 2 1 - NO NC 115 175 Ø 30 55 59 75 80 65 30 40 75 100 150 200 3/Ø 40 7755 80 90 100 65 40 50 100 125 LC1-F115 ■ ■ 185 200 3/Ø 55 9900 100 110 110 100 50 60 125 150 LC1-F150 ■ ■ 30 LC1-F185 ■ ■ 225 200 300 MCM 63 110 110 129 129 100 60 75 150 150 265 285 300 MCM 75 132 140 160 160 147 60 75 150 200 330 360 300 MCM 100 160 180 200 220 160 75 100 200 250 400 420 600 MCM 110 200 220 257 280 185 100 125 250 300 LC1-F225 ■ ■ LC1-F265 ■ ■ LC1-F330 ■ ■ LC1-F400 ■ ■ 132 50 LR9-F5357 500 700 2 x 600 MCM 147 250 280 355 335 335 150 200 400 500 LC1-F500 ■ ■ 630 1000 3 x 600 MCM 200 335 375 400 450 450 250 300 600 800 800 1000 3 x 600 MCM 250 450 450 450 475 450 450 800 900 LC1-F630 ■ ■ LC1-F800 ▼ ▼ 220 LR9-F5371 200 LR9-F5363 48 80 60 330 LR9-F7375 100 LR9-F7379 LR9-F5367 300 500 LR9-F5369 LR9-F7381 90 LT6-P0M005FM + LTC-CT•001 150 1A 5A 380 630 630 780 1350 4 x 750 MCM 450 900 900 LC1-F780 ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ NO NC NO NC NO NC Built-in auxiliary contacts 750 1000 800 1250 2 x 80mm x 5mm55552 x 80mm x 5mm5555 220 280 400 500 425 590 500 600 560 670 530 530 LC1BL3 ❍▼ 22 LC1BM3 ❍▼ 22 2 2 1500 2000 3 x 100mm x 5mm5555 425 750 800 750 750 670 LC1BP3 ❍▼ 22 1800 2750 4 x 100mm x 5mm5555 500 900 900 900 900 750 LC1BR3 ❍▼ A A AWG kW kW kW kW kW kW HP HP HP HP AC DC 22 1A + LR2D1305 5A + LR2D1310 2750 A 2750 A For heavy-duty applications, contactors designed to switch up to 2750 amps Protection and intelligence combined ■ The LT6-P electronic multifunction protection relay is ideally suited to high performance applications. It provides protection for your motors in virtually any application or operating condition. ■ It enables automatic control of different methods of starting: ■ ■ ■ CV1 Contactors ■ ■ ■ ■ ■ For loads up to 950 amps inductive, 1000 amps resistive Voltage up to 660 VAC or 440 VDC Frequency up to 200 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles ■ All the functionalities are programmable with parameters entered locally or using a PC software. ■ It integrates into all the most complex automation systems through its communication functions on UNITELWAY®, JBUS™, MODBUS® protocols. Thermal Overload Relays from 6 to 2750 A Manual Starter and Protector The TELEMECANIQUE GV2 and GV3 devices incorporate a manual disconnect, overload relay and instantaneous magnetic trip mechanism in one compact device. They can be used as standalone manual starters or to protect each branch circuit of a group motor installation. in hard ambient conditions: high temperature, dust, humidity with severe duty: fast operating cycles, use of DC injection braking. cross-line (reversing or non-reversing) star/delta 2-speed ■ Contactors and Request document 8539CT9201R6/97 The LT3-S thermistor relay provides complementary protection by direct measurement of the temperature of motors equipped with PTC thermistor probes, for operation: ■ ■ INTEGRAL™ Self-Protected Starters TELEMECANIQUE ® INTEGRAL self-protected starters combine circuit breaker, contactor and dual function overload relay for coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated protection. INTEGRAL starters can reduce panel space requirements by 40 to 60%. 18A, 32A and 63A models are available. Protect your motor from damaging over-temperatures Request document 252OCT9501R6/97 Enclosed IEC Starters D-Line starters and INTEGRAL self-protected starters are available in metal NEMA Type 1 and 12 enclosures. These enclosed devices utilize INSTAKIT ™ components for the addition of cover mounted pilot devices. INSTAKIT components are pre-wired control operator kits that use a universal connector for quick, easy installation. Request following documents 9502HO9401R0996 - INSTAKIT pre-wired starter access 9502HO9402R0996 - D-Line non-combination starters 9502HO9403R0996 - INTEGRAL starters 8502CT0101 - IEC SMCE contactors and starters 8502BR0102-TeSys-The New D-LINE D-Line, K-Line and F-Line contactors and overload relays are the largest selling motor starting and protection devices in the world. They offer starting for motors up to 800 hp at 480 AC volts and switching of resistive loads up to 1350 amps. They are UL-listed, CSA-certified and CE-marked for use in North America and around the world. CV3 Contactors ■ ■ ■ ■ ■ For loads up to 1800 amps inductive, 2750 amps resistive Voltage up to 1000 VAC or 1500 VDC Frequency up to 400 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles Visit the Square D web site at www.SquareD.com Order Number 8502BR0101 Printed in U.S.A. © 2001 Schneider Electric All Rights Reserved Schneider Electric Brands Get more with the world’s Power & Control specialist. For heavy-duty applications, contactors designed to switch up to 2750 amps Protection and intelligence combined ■ The LT6-P electronic multifunction protection relay is ideally suited to high performance applications. It provides protection for your motors in virtually any application or operating condition. ■ It enables automatic control of different methods of starting: ■ ■ ■ CV1 Contactors ■ ■ ■ ■ ■ For loads up to 950 amps inductive, 1000 amps resistive Voltage up to 660 VAC or 440 VDC Frequency up to 200 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles ■ All the functionalities are programmable with parameters entered locally or using a PC software. ■ It integrates into all the most complex automation systems through its communication functions on UNITELWAY®, JBUS™, MODBUS® protocols. Thermal Overload Relays from 6 to 2750 A Manual Starter and Protector The TELEMECANIQUE GV2 and GV3 devices incorporate a manual disconnect, overload relay and instantaneous magnetic trip mechanism in one compact device. They can be used as standalone manual starters or to protect each branch circuit of a group motor installation. in hard ambient conditions: high temperature, dust, humidity with severe duty: fast operating cycles, use of DC injection braking. cross-line (reversing or non-reversing) star/delta 2-speed ■ Contactors and Request document 8539CT9201R6/97 The LT3-S thermistor relay provides complementary protection by direct measurement of the temperature of motors equipped with PTC thermistor probes, for operation: ■ ■ INTEGRAL™ Self-Protected Starters TELEMECANIQUE ® INTEGRAL self-protected starters combine circuit breaker, contactor and dual function overload relay for coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated protection. INTEGRAL starters can reduce panel space requirements by 40 to 60%. 18A, 32A and 63A models are available. Protect your motor from damaging over-temperatures Request document 252OCT9501R6/97 Enclosed IEC Starters D-Line starters and INTEGRAL self-protected starters are available in metal NEMA Type 1 and 12 enclosures. These enclosed devices utilize INSTAKIT ™ components for the addition of cover mounted pilot devices. INSTAKIT components are pre-wired control operator kits that use a universal connector for quick, easy installation. Request following documents 9502HO9401R0996 - INSTAKIT pre-wired starter access 9502HO9402R0996 - D-Line non-combination starters 9502HO9403R0996 - INTEGRAL starters 8502CT0101 - IEC SMCE contactors and starters 8502BR0102-TeSys-The New D-LINE D-Line, K-Line and F-Line contactors and overload relays are the largest selling motor starting and protection devices in the world. They offer starting for motors up to 800 hp at 480 AC volts and switching of resistive loads up to 1350 amps. They are UL-listed, CSA-certified and CE-marked for use in North America and around the world. CV3 Contactors ■ ■ ■ ■ ■ For loads up to 1800 amps inductive, 2750 amps resistive Voltage up to 1000 VAC or 1500 VDC Frequency up to 400 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles Visit the Square D web site at www.SquareD.com Order Number 8502BR0101 Printed in U.S.A. © 2001 Schneider Electric All Rights Reserved Schneider Electric Brands Get more with the world’s Power & Control specialist. For heavy-duty applications, contactors designed to switch up to 2750 amps Protection and intelligence combined ■ The LT6-P electronic multifunction protection relay is ideally suited to high performance applications. It provides protection for your motors in virtually any application or operating condition. ■ It enables automatic control of different methods of starting: ■ ■ ■ CV1 Contactors ■ ■ ■ ■ ■ For loads up to 950 amps inductive, 1000 amps resistive Voltage up to 660 VAC or 440 VDC Frequency up to 200 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles ■ All the functionalities are programmable with parameters entered locally or using a PC software. ■ It integrates into all the most complex automation systems through its communication functions on UNITELWAY®, JBUS™, MODBUS® protocols. Thermal Overload Relays from 6 to 2750 A Manual Starter and Protector The TELEMECANIQUE GV2 and GV3 devices incorporate a manual disconnect, overload relay and instantaneous magnetic trip mechanism in one compact device. They can be used as standalone manual starters or to protect each branch circuit of a group motor installation. in hard ambient conditions: high temperature, dust, humidity with severe duty: fast operating cycles, use of DC injection braking. cross-line (reversing or non-reversing) star/delta 2-speed ■ Contactors and Request document 8539CT9201R6/97 The LT3-S thermistor relay provides complementary protection by direct measurement of the temperature of motors equipped with PTC thermistor probes, for operation: ■ ■ INTEGRAL™ Self-Protected Starters TELEMECANIQUE ® INTEGRAL self-protected starters combine circuit breaker, contactor and dual function overload relay for coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated protection. INTEGRAL starters can reduce panel space requirements by 40 to 60%. 18A, 32A and 63A models are available. Protect your motor from damaging over-temperatures Request document 252OCT9501R6/97 Enclosed IEC Starters D-Line starters and INTEGRAL self-protected starters are available in metal NEMA Type 1 and 12 enclosures. These enclosed devices utilize INSTAKIT ™ components for the addition of cover mounted pilot devices. INSTAKIT components are pre-wired control operator kits that use a universal connector for quick, easy installation. Request following documents 9502HO9401R0996 - INSTAKIT pre-wired starter access 9502HO9402R0996 - D-Line non-combination starters 9502HO9403R0996 - INTEGRAL starters 8502CT0101 - IEC SMCE contactors and starters 8502BR0102-TeSys-The New D-LINE D-Line, K-Line and F-Line contactors and overload relays are the largest selling motor starting and protection devices in the world. They offer starting for motors up to 800 hp at 480 AC volts and switching of resistive loads up to 1350 amps. They are UL-listed, CSA-certified and CE-marked for use in North America and around the world. CV3 Contactors ■ ■ ■ ■ ■ For loads up to 1800 amps inductive, 2750 amps resistive Voltage up to 1000 VAC or 1500 VDC Frequency up to 400 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles Visit the Square D web site at www.SquareD.com Order Number 8502BR0101 Printed in U.S.A. © 2001 Schneider Electric All Rights Reserved Schneider Electric Brands Get more with the world’s Power & Control specialist. For heavy-duty applications, contactors designed to switch up to 2750 amps Protection and intelligence combined ■ The LT6-P electronic multifunction protection relay is ideally suited to high performance applications. It provides protection for your motors in virtually any application or operating condition. ■ It enables automatic control of different methods of starting: ■ ■ ■ CV1 Contactors ■ ■ ■ ■ ■ For loads up to 950 amps inductive, 1000 amps resistive Voltage up to 660 VAC or 440 VDC Frequency up to 200 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles ■ All the functionalities are programmable with parameters entered locally or using a PC software. ■ It integrates into all the most complex automation systems through its communication functions on UNITELWAY®, JBUS™, MODBUS® protocols. Thermal Overload Relays from 6 to 2750 A Manual Starter and Protector The TELEMECANIQUE GV2 and GV3 devices incorporate a manual disconnect, overload relay and instantaneous magnetic trip mechanism in one compact device. They can be used as standalone manual starters or to protect each branch circuit of a group motor installation. in hard ambient conditions: high temperature, dust, humidity with severe duty: fast operating cycles, use of DC injection braking. cross-line (reversing or non-reversing) star/delta 2-speed ■ Contactors and Request document 8539CT9201R6/97 The LT3-S thermistor relay provides complementary protection by direct measurement of the temperature of motors equipped with PTC thermistor probes, for operation: ■ ■ INTEGRAL™ Self-Protected Starters TELEMECANIQUE ® INTEGRAL self-protected starters combine circuit breaker, contactor and dual function overload relay for coordinated circuit protection. INTEGRAL starters are the only selfprotected starters to have UL/CSA verification for Type 2 coordinated protection. INTEGRAL starters can reduce panel space requirements by 40 to 60%. 18A, 32A and 63A models are available. Protect your motor from damaging over-temperatures Request document 252OCT9501R6/97 Enclosed IEC Starters D-Line starters and INTEGRAL self-protected starters are available in metal NEMA Type 1 and 12 enclosures. These enclosed devices utilize INSTAKIT ™ components for the addition of cover mounted pilot devices. INSTAKIT components are pre-wired control operator kits that use a universal connector for quick, easy installation. Request following documents 9502HO9401R0996 - INSTAKIT pre-wired starter access 9502HO9402R0996 - D-Line non-combination starters 9502HO9403R0996 - INTEGRAL starters 8502CT0101 - IEC SMCE contactors and starters 8502BR0102-TeSys-The New D-LINE D-Line, K-Line and F-Line contactors and overload relays are the largest selling motor starting and protection devices in the world. They offer starting for motors up to 800 hp at 480 AC volts and switching of resistive loads up to 1350 amps. They are UL-listed, CSA-certified and CE-marked for use in North America and around the world. CV3 Contactors ■ ■ ■ ■ ■ For loads up to 1800 amps inductive, 2750 amps resistive Voltage up to 1000 VAC or 1500 VDC Frequency up to 400 Hz Maximum of 5 NO or NC power poles Maximum of 7 NO or NC auxiliary poles Visit the Square D web site at www.SquareD.com Order Number 8502BR0101 Printed in U.S.A. © 2001 Schneider Electric All Rights Reserved Schneider Electric Brands Get more with the world’s Power & Control specialist.