SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
bq241xx Synchronous Switched-Mode, Li-Ion and Li-Polymer Charge-Management
IC With Integrated Power FETs (bqSWITCHER™)
1 Features
2 Applications
•
•
•
•
•
1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Ideal For Highly Efficient Charger Designs For
Single-, Two-, or Three-Cell Li-Ion and Li-Polymer
Battery Packs
bq24105 Also for LiFePO4 Battery (see Using
bq24105 to Charge the LiFePO4 Battery)
Integrated Synchronous Fixed-Frequency PWM
Controller Operating at 1.1 MHz With 0% to 100%
Duty Cycle
Integrated Power FETs for Up To 2-A Charge
Rate
High-Accuracy Voltage and Current Regulation
Available in Both Stand-Alone (Built-In Charge
Management and Control) and System-Controlled
(Under System Command) Versions
Status Outputs for LED or Host Processor
Interface Indicates Charge-In-Progress, Charge
Completion, Fault, and AC-Adapter Present
Conditions
20-V Maximum Voltage Rating on IN and OUT
Pins
High-Side Battery Current Sensing
Battery Temperature Monitoring
Automatic Sleep Mode for Low Power
Consumption
System-Controlled Version Can Be Used in NiMH
and NiCd Applications
Reverse Leakage Protection Prevents Battery
Drainage
Thermal Shutdown and Protection
Built-In Battery Detection
Available in 20-Pin, 3.50 mm × 4.50 mm VQFN
Package
Handheld Products
Portable Media Players
Industrial and Medical Equipment
Portable Equipment
3 Description
The bqSWITCHER™ series are highly integrated Liion and Li-polymer switch-mode charge management
devices targeted at a wide range of portable
applications. The bqSWITCHER™ series offers
integrated synchronous PWM controller and power
FETs, high-accuracy current and voltage regulation,
charge preconditioning, charge status, and charge
termination, in a small, thermally enhanced VQFN
package. The system-controlled version provides
additional inputs for full charge management under
system control.
The bqSWITCHER™ charges the battery in three
phases: conditioning, constant current, and constant
voltage. Charge is terminated based on userselectable minimum current level. A programmable
charge timer provides a safety backup for charge
termination. The bqSWITCHER™ automatically
restarts the charge cycle if the battery voltage falls
below an internal threshold. The bqSWITCHER™
automatically enters sleep mode when VCC supply is
removed.
Device Information
PART NUMBER
bq241xx
PACKAGE
VQFN (20)
(1)
BODY SIZE (NOM)
3.50 mm × 4.50 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Typical 1-Cell Application
LOUT
BQ24100
VIN
CIN
1.5 KW
10 mF
1.5 KW
Adapter
Present
1.5 KW
Done
Charge
3
IN
OUT 1
4
IN
OUT 20
6
VCC
RSNS
10 mH
D1
PGND 17
COUT
0.1W
10 mF
Battery
Pack
Pack+
Pack-
MMBZ18VALT1
103AT
2
STAT1 PGND 18
19 STAT2
5
PG
7
TTC
SNS 15
BAT 14
ISET1 8
7.5 KW RISET1
VTSB
7.5 KW
CTTC
16 CE
ISET2 9
0.1 mF
10 VSS
13 NC
0.1 mF
9.31 KW
RT1
442 KW
RT2
RISET2
TS 12
VTSB 11
0.1 mF
0.1 mF
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
Table of Contents
1
2
3
4
5
6
7
Features ..................................................................
Applications ...........................................................
Description .............................................................
Revision History.....................................................
Device Options.......................................................
Pin Configuration and Functions .........................
Specifications.........................................................
7.1
7.2
7.3
7.4
7.5
7.6
7.7
8
1
1
1
2
4
5
6
Absolute Maximum Ratings ..................................... 6
ESD Ratings.............................................................. 6
Recommended Operating Conditions....................... 7
Thermal Information .................................................. 7
Electrical Characteristics........................................... 7
Dissipation Ratings ................................................. 10
Typical Characteristics ............................................ 10
Detailed Description ............................................ 11
8.1
8.2
8.3
8.4
Overview .................................................................
Functional Block Diagram .......................................
Feature Description.................................................
Device Functional Modes........................................
11
12
13
22
9
Application and Implementation ........................ 24
9.1 Application Information............................................ 24
9.2 Typical Application ................................................. 24
9.3 System Examples ................................................... 28
10 Power Supply Recommendations ..................... 32
11 Layout................................................................... 32
11.1 Layout Guidelines ................................................. 32
11.2 Layout Example .................................................... 34
11.3 Thermal Considerations ........................................ 34
12 Device and Documentation Support ................. 35
12.1
12.2
12.3
12.4
12.5
12.6
12.7
Device Support......................................................
Documentation Support ........................................
Related Links ........................................................
Community Resources..........................................
Trademarks ...........................................................
Electrostatic Discharge Caution ............................
Glossary ................................................................
35
35
35
35
35
36
36
13 Mechanical, Packaging, and Orderable
Information ........................................................... 36
4 Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from Revision O (March 2010) to Revision P
•
Page
Added ESD Ratings table, Feature Description section, Device Functional Modes, Application and Implementation
section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and
Mechanical, Packaging, and Orderable Information section .................................................................................................. 1
Changes from Revision M (August 2008) to Revision N
Page
•
Added part number bq24104.................................................................................................................................................. 1
•
Added part number bq24104 to the Ordering Information ..................................................................................................... 4
•
Deleted Product Preview from bq24104RHLR ....................................................................................................................... 4
•
Deleted Product Preview from bq24104RHLT ....................................................................................................................... 4
•
Added bq24104 to the Terminal Functions table.................................................................................................................... 5
•
Added part number bq24104 to the Deglitch time.................................................................................................................. 8
•
Added bq24104 to Table 2. .................................................................................................................................................. 16
•
Added part number bq24104 to Figure 16 .......................................................................................................................... 28
Changes from Revision L (December 2007) to Revision M
Page
•
Changed specifications and symbols for (cold, hot, and cutoff) temperature thresholds....................................................... 8
•
Changed equation definitions ............................................................................................................................................... 13
•
Changed equation definitions ............................................................................................................................................... 27
Changes from Revision K (November 2007) to Revision L
Page
•
Changed Added figure almost identical to Figure 3. Changed RISET2 to 20 kohms. ......................................................... 31
•
Added Changed resistor bridge values 301 to 143, 100 to 200 Kohms............................................................................... 31
2
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
Changes from Revision J (October 2007) to Revision K
Page
•
Changed From: CIU To: CDY................................................................................................................................................. 4
•
Added bq24109 to VOREG ....................................................................................................................................................... 7
•
Added part number bq24109 to VLOWV .................................................................................................................................. 8
•
Changed Deglitch time for temperature fault, TS, bq24109 typical value From: 1000 To: 500 ............................................. 8
•
Changed From: Single-cell or two-cell To: one-, two-, or three-cell applications. Deleted text............................................ 13
Changes from Revision I (August 2007) to Revision J
Page
•
Added part number bq24109 ................................................................................................................................................. 1
•
Added part number bq24109 to the Ordering Information ..................................................................................................... 4
•
Added bq24109 to the Terminal Functions table.................................................................................................................... 5
•
Added part number bq24109 to the Deglitch time.................................................................................................................. 8
•
Added bq24109 to Table 2. .................................................................................................................................................. 16
Changes from Revision H (July 2007) to Revision I
Page
•
Added part number bq24103A .............................................................................................................................................. 1
•
Changed device size From: 5,5 mm x 3.5 mm To: 4,5 mm x 3.5 mm ................................................................................... 1
•
Added part number bq24103A to the Ordering Information ................................................................................................... 4
•
Added bq24103A to the Terminal Functions table. ................................................................................................................ 5
•
Added part numbers bq24103Ana d bq24113A to VOREG ..................................................................................................... 7
•
Added part number bq24103A to VLOWV ................................................................................................................................ 8
•
Added part number bq24103A to Figure 16 ........................................................................................................................ 28
Changes from Revision G (June 2007) to Revision H
Page
•
Changed Figure 1 ................................................................................................................................................................ 10
•
Changed Figure 2 ................................................................................................................................................................ 10
•
Added D1 to diode MMBZ18VALT1 in Figure 13................................................................................................................. 24
•
Added D1 to diode MMBZ18VALT1 in Figure 16 ................................................................................................................ 28
•
Added D1 to diode MMBZ18VALT1 in Figure 17 ................................................................................................................ 29
•
Added D1 to diode MMBZ18VALT1 and Note A to Figure 18. ............................................................................................ 29
Changes from Revision F (January 2007) to Revision G
Page
•
Added bq24113A to the data sheet and the Ordering Information......................................................................................... 4
•
Added bq24113A to the Terminal Functions table. ................................................................................................................ 5
•
Changed bq24113A added to Figure 18 ............................................................................................................................. 29
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
3
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
5 Device Options
(1)
(2)
(3)
4
CHARGE REGULATION VOLTAGE (V)
INTENDED APPLICATION
PART NUMBER
(1) (2) (3)
4.2 V
Stand-alone
bq24100
1 or 2 cells selectable (CELLS pin, 4.2 V or 8.4 V)
Stand-alone
bq24103
1 or 2 cells selectable (CELLS pin, 4.2 V or 8.4 V)
Stand-alone
bq24103A
1 or 2 cells selectable (CELLS pin, 4.2 V or 8.4 V)
(Blinking status pins)
Stand-alone
bq24104
Externally programmable (2.1 V to 15.5 V)
Stand-alone
bq24105
4.2 V (Blinking status pins)
Stand-alone
1 or 2 cells selectable (CELLS pin, 4.2 V or 8.4 V)
System-controlled
bq24113
1 or 2 cells selectable (CELLS pin, 4.2 V or 8.4 V)
System-controlled
bq24113A
Externally programmable (2.1 V to 15.5 V)
System-controlled
bq24115
bq24108
bq24109
The RHL package is available in the following options:
T – taped and reeled in quantities of 250 devices per reel
R – taped and reeled in quantities of 3000 devices per reel
This product is RoHS-compatible, including a lead concentration that does not exceed 0.1% of total product weight, and is suitable for
use in specified lead-free soldering processes.
TJ = –40°C to 125°C
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
6 Pin Configuration and Functions
OUT
OUT
RHL Package
20-Pin VQFN
Top View
1
2
20 19
3
18
4
17
5
16
6
15
7
14
8
13
9 10
STAT2 or NC
PGND
PGND
CE
SNS
BAT
CELLS or FB or NC
TS
VTSB
11 12
VSS
STAT1
IN
IN
PG
VCC
TTC or CMODE
ISET1
ISET2
bq24100, 03, 03A, 04, 05, 08, 09, 13, 13A, 15
Pin Functions
PIN
bq24100,
bq24108,
bq24109
bq24103,
bq24103A
bq24104
bq24105
bq24113,
bq24113A
bq24115
BAT
14
14
14
14
14
I
Battery voltage sense input. Bypass it with a 0.1 μF capacitor to PGND if
there are long inductive leads to battery.
CE
16
16
16
16
16
I
Charger enable input. This active low input, if set high, suspends charge
and places the device in the low-power sleep mode. Do not pull up this
input to VTSB.
I
Available on parts with fixed output voltage. Ground or float for single-cell
operation (4.2 V). For two-cell operation (8.4 V) pull up this pin with a
resistor to VCC.
7
I
Charge mode selection: low for precharge as set by ISET2 pin and high
(pull up to VTSB or <7 V) for fast charge as set by ISET1.
13
I
Output voltage analog feedback adjustment. Connect the output of a
resistive voltage divider powered from the battery terminals to this node to
adjust the output battery voltage regulation.
Charger input voltage.
NAME
CELLS
13
13
CMODE
7
FB
IN
ISET1
13
I/O
DESCRIPTION
3, 4
3, 4
3, 4
3, 4
3, 4
I
8
8
8
8
8
I/O
Charger current set point 1 (fast charge). Use a resistor to ground to set
this value.
I/O
Charge current set point 2 (precharge and termination), set by a resistor
connected to ground. A low-level CMODE signal selects the ISET2 charge
rate, but if the battery voltage reaches the regulation set point,
bqSWITCHER™ changes to voltage regulation regardless of CMODE
input.
ISET2
9
9
9
N/C
13
19
19
-
No connection. This pin must be left floating in the application.
1
1
O
20
20
20
O
Charge current output inductor connection. Connect a zener TVS diode
between OUT pin and PGND pin to clamp the voltage spike to protect the
power MOSFETs during abnormal conditions.
5
5
5
5
O
17,18
17,18
17,18
17,18
17, 18
SNS
15
15
15
15
15
I
Charge current-sense input. Battery current is sensed via the voltage drop
developed on this pin by an external sense resistor in series with the
battery pack. A 0.1-μF capacitor to PGND is required.
STAT1
2
2
2
2
2
O
Charge status 1 (open-drain output). When the transistor turns on
indicates charge in process. When it is off and with the condition of STAT2
indicates various charger conditions (See Table 1)
OUT
PG
PGND
9
9
1
1
1
20
20
5
Copyright © 2004–2015, Texas Instruments Incorporated
Power-good status output (open drain). The transistor turns on when a
valid VCC is detected. It is turned off in the sleep mode. PG can be used to
drive a LED or communicate with a host processor.
Power ground input
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
5
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
Pin Functions (continued)
PIN
NAME
bq24100,
bq24108,
bq24109
bq24103,
bq24103A
bq24104
bq24105
STAT2
19
19
19
TS
12
12
12
TTC
7
7
7
bq24113,
bq24113A
12
bq24115
12
VCC
6
6
6
6
6
VSS
10
10
10
10
10
VTSB
11
11
11
11
11
Exposed
Thermal
Pad
Pad
Pad
Pad
Pad
I/O
DESCRIPTION
O
Charge status 2 (open-drain output). When the transistor turns on
indicates charge is done. When it is off and with the condition of STAT1
indicates various charger conditions (See Table 1)
I
Temperature sense input. This input monitors its voltage against an
internal threshold to determine if charging is allowed. Use an NTC
thermistor and a voltage divider powered from VTSB to develop this
voltage. (See Figure 4)
I
Timer and termination control. Connect a capacitor from this node to GND
to set the bqSWITCHER™ timer. When this input is low, the timer and
termination detection are disabled.
I
Analog device input. A 0.1 μF capacitor to VSS is required.
Analog ground input
O
Pad
TS internal bias regulator voltage. Connect capacitor (with a value
between a 0.1-μF and 1-μF) between this output and VSS.
There is an internal electrical connection between the exposed thermal
pad and VSS. The exposed thermal pad must be connected to the same
potential as the VSS pin on the printed circuit board. The power pad can
be used as a star ground connection between VSS and PGND. A common
ground plane may be used. VSS pin must be connected to ground at all
times.
7 Specifications
7.1 Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN
Supply voltage (with respect to
VSS)
Input voltage (with respect to
VSS and PGND)
IN, VCC
MAX
UNIT
20
V
STAT1, STAT2, PG, CE, CELLS, SNS, BAT
–0.3
20
V
OUT
–0.7
20
V
7
V
VTSB
3.6
V
ISET1, ISET2
3.3
V
±1
V
mA
CMODE, TS, TTC
Voltage difference between SNS and BAT inputs (VSNS – VBAT)
Output sink
STAT1, STAT2, PG
10
Output current (average)
OUT
2.2
A
Operating free-air temperature, TA
–40
85
°C
Junction temperature, TJ
–40
125
°C
300
°C
150
°C
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds
Storage temperature, Tstg
(1)
–65
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
7.2 ESD Ratings
VALUE
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
V(ESD)
Electrostatic discharge
Charged-device model (CDM), per JEDEC specification JESD22-C101
(2)
(1)
(2)
6
(1)
UNIT
±2000
±500
V
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
7.3 Recommended Operating Conditions
MIN
Supply voltage, VCC and IN (Tie together)
4.35
Operating junction temperature range, TJ
(1)
(2)
NOM
(1)
MAX
16
–40
UNIT
(2)
V
125
°C
The IC continues to operate below Vmin, to 3.5 V, but the specifications are not tested and not specified.
The inherent switching noise voltage spikes should not exceed the absolute maximum rating on either the IN or OUT pins. A tight layout
minimizes switching noise.
7.4 Thermal Information
bq241xx
THERMAL METRIC
(1)
RHL (VQFN)
UNIT
20 PINS
RθJA
Junction-to-ambient thermal resistance
39.2
°C/W
RθJC(top)
Junction-to-case (top) thermal resistance
39.3
°C/W
RθJB
Junction-to-board thermal resistance
15.8
°C/W
ψJT
Junction-to-top characterization parameter
0.6
°C/W
ψJB
Junction-to-board characterization parameter
15.8
°C/W
RθJC(bot)
Junction-to-case (bottom) thermal resistance
3.6
°C/W
(1)
For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
7.5 Electrical Characteristics
TJ = 0°C to 125°C and recommended supply voltage range (unless otherwise stated)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
INPUT CURRENTS
VCC > VCC(min), PWM switching
I(VCC)
I(SLP)
VCC supply current
Battery discharge sleep current, (SNS,
BAT, OUT, FB pins)
10
VCC > VCC(min), PWM NOT switching
5
VCC > VCC(min), CE = HIGH
315
0°C ≤ TJ ≤ 65°C, VI(BAT) = 4.2 V,
VCC < V(SLP) or VCC > V(SLP) but not in charge
3.5
0°C ≤ TJ ≤ 65°C, VI(BAT) = 8.4 V,
VCC < V(SLP) or VCC > V(SLP) but not in charge
5.5
0°C ≤ TJ ≤ 65°C, VI(BAT) = 12.6 V,
VCC < V(SLP) or VCC > V(SLP) but not in charge
7.7
mA
μA
μA
VOLTAGE REGULATION
VOREG
VIBAT
CELLS = Low, in voltage regulation
4.2
CELLS = High, in voltage regulation
8.4
Output voltage, bq24100/08/09
Operating in voltage regulation
4.2
Feedback regulation REF for bq24105/15
only (W/FB)
IIBAT = 25 nA typical into pin
2.1
Output voltage, bq24103/03A/04/13/13A
Voltage regulation accuracy
TA = 25°C
V
V
–0.5%
0.5%
–1%
1%
150
2000
–10%
10%
CURRENT REGULATION - FAST CHARGE
IOCHARGE
Output current range of converter
VLOWV ≤ VI(BAT) < VOREG,
V(VCC) - VI(BAT) > V(DO-MAX)
mA
100 mV ≤ VIREG≤ 200 mV,
V
VIREG
Voltage regulated across R(SNS) Accuracy
V(ISET1)
Output current set voltage
Copyright © 2004–2015, Texas Instruments Incorporated
IREG
+
1V
RSET1
1000,
Programmed Where
5 kΩ ≤ RSET1 ≤ 10 kΩ, Select RSET1 to
program VIREG,
VIREG(measured) = IOCHARGE + RSNS
(–10% to 10% excludes errors due to RSET1
and R(SNS) tolerances)
V(LOWV) ≤ VI(BAT) ≤ VO(REG),
V(VCC) ≤ VI(BAT) × V(DO-MAX)
1
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
V
7
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
Electrical Characteristics (continued)
TJ = 0°C to 125°C and recommended supply voltage range (unless otherwise stated)
PARAMETER
K(ISET1)
Output current set factor
TEST CONDITIONS
MIN
VLOWV ≤ VI(BAT) < VO(REG) ,
V(VCC) ≤ VI(BAT) + V(DO-MAX)
TYP
MAX
1000
UNIT
V/A
PRECHARGE AND SHORT-CIRCUIT CURRENT REGULATION
VLOWV
Precharge to fast-charge transition voltage
threshold, BAT,
bq24100/03/03A/04/05/08/09 ICs only
t
Deglitch time for precharge to fast charge
transition,
IOPRECHG
V(ISET2)
K(ISET2)
Precharge current set factor
68
71.4
75
%VO(REG)
Rising voltage;
tRISE, tFALL = 100 ns, 2-mV overdrive
20
30
40
ms
Precharge range
VI(BAT) < VLOWV, t < tPRECHG
15
200
mA
Precharge set voltage, ISET2
VI(BAT) < VLOWV, t < tPRECHG
100
mV
1000
V/A
100 mV ≤ VIREG-PRE ≤ 100 mV,
V
VIREG-PRE
Voltage regulated across RSNS-Accuracy
IREG*PRE
+ 0.1V
RSET2
1000,
(PGM) Where
1.2 kΩ ≤ RSET2 ≤ 10 kΩ, Select RSET1
to program VIREG-PRE,
VIREG-PRE (Measured) = IOPRE-CHG × RSNS
(–20% to 20% excludes errors due to RSET1
and RSNS tolerances)
–20%
20%
15
200
CHARGE TERMINATION (CURRENT TAPER) DETECTION
ITERM
Charge current termination detection range
VI(BAT) > VRCH
VTERM
Charge termination detection set voltage,
ISET2
VI(BAT) > VRCH
K(ISET2)
Termination current set factor
tdg-TERM
100
mV
1000
Charger termination accuracy
VI(BAT) > VRCH
Deglitch time for charge termination
Both rising and falling,
2-mV overdrive tRISE, tFALL = 100 ns
–20%
mA
V/A
20%
20
30
40
ms
TEMPERATURE COMPARATOR AND VTSB BIAS REGULATOR
%LTF
Cold temperature threshold, TS, % of bias
VLTF = VO(VTSB) × % LTF/100
72.8%
73.5%
74.2%
%HTF
Hot temperature threshold, TS, % of bias
VHTF = VO(VTSB) × % HTF/100
33.7%
34.4%
35.1%
%TCO
Cutoff temperature threshold, TS, % of
bias
VTCO = VO(VTSB) × % TCO/100
28.7%
29.3%
29.9%
0.5%
1%
1.5%
20
30
40
LTF hysteresis
Deglitch time for temperature fault, TS
Both rising and falling,
2-mV overdrive tRISE, tFALL = 100 ns
tdg-TS
Deglitch time for temperature fault, TS,
bq24109, bq24104
VO(VTSB)
TS bias output voltage
VCC > VIN(min),
I(VTSB) = 10 mA 0.1 μF ≤ CO(VTSB) ≤ 1 μF
VO(VTSB)
TS bias voltage regulation accuracy
VCC > IN(min),
I(VTSB) = 10 mA 0.1 μF ≤ CO(VTSB) ≤ 1 μF
ms
500
3.15
–10%
V
10%
BATTERY RECHARGE THRESHOLD
VRCH
tdg-RCH
Recharge threshold voltage
Below VOREG
75
100
125
mV/cell
Deglitch time
VI(BAT) < decreasing below threshold,
tFALL = 100 ns 10-mV overdrive
20
30
40
ms
STAT1, STAT2, AND PG OUTPUTS
VOL(STATx)
Low-level output saturation voltage, STATx
IO = 5 mA
0.5
VOL(PG)
Low-level output saturation voltage, PG
IO = 10 mA
0.1
V
CE CMODE, CELLS INPUTS
VIL
Low-level input voltage
IIL = 5 μA
VIH
High-level input voltage
IIH = 20 μA
0
0.4
1.3
VCC
V
TTC INPUT
tPRECHG
Precharge timer
tCHARGE
Programmable charge timer range
t(CHG) = C(TTC) × K(TTC)
Charge timer accuracy
0.01 μF ≤ C(TTC) ≤ 0.18 μF
8
Submit Documentation Feedback
1440
2160
s
25
1800
572
minutes
-10%
10%
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
Electrical Characteristics (continued)
TJ = 0°C to 125°C and recommended supply voltage range (unless otherwise stated)
PARAMETER
KTTC
Timer multiplier
CTTC
Charge time capacitor range
VTTC_EN
TTC enable threshold voltage
TEST CONDITIONS
MIN
TYP
MAX
2.6
0.01
V(TTC) rising
UNIT
min/nF
μF
0.22
200
mV
SLEEP COMPARATOR
VSLP-ENT
Sleep-mode entry threshold
VSLP-EXIT
Sleep-mode exit hysteresis,
tdg-SLP
Deglitch time for sleep mode
2.3 V ≤ VI(OUT) ≤ VOREG, for 1 or 2 cells
VCC ≤ VIBAT
+5 mV
VCC ≤ VIBAT
+75 mV
VI(OUT) = 12.6 V, RIN = 1 kΩ
bq24105/15 (1)
VCC ≤ VIBAT
-4 mV
VCC ≤ VIBAT
+73 mV
40
160
2.3 V ≤ VI(OUT)≤ VOREG
VCC decreasing below threshold,
tFALL = 100 ns, 10-mV overdrive,
PMOS turns off
VCC decreasing below threshold,
tFALL = 100 ns, 10-mV overdrive,
STATx pins turn off
V
mV
μs
5
20
30
40
3.50
ms
UVLO
VUVLO-ON
IC active threshold voltage
VCC rising
3.15
3.30
IC active hysteresis
VCC falling
120
150
V
mV
PWM
Internal P-channel MOSFET on-resistance
Internal N-channel MOSFET on-resistance
fOSC
7 V ≤ VCC ≤ VCC(max)
400
4.5 V ≤ VCC ≤ 7 V
500
7 V ≤ VCC ≤ VCC(max)
130
4.5 V ≤ VCC ≤ 7 V
mΩ
150
Oscillator frequency
1.1
Frequency accuracy
–9%
MHz
9%
DMAX
Maximum duty cycle
DMIN
Minimum duty cycle
100%
tTOD
Switching delay time (turn on)
20
ns
tsyncmin
Minimum synchronous FET on time
60
ns
0%
Synchronous FET minimum current-off
threshold (2)
50
400
mA
BATTERY DETECTION
IDETECT
Battery detection current during time-out
fault
VI(BAT) < VOREG – VRCH
IDISCHRG1
Discharge current
tDISCHRG1
Discharge time
IWAKE
Wake current
tWAKE
Wake time
IDISCHRG2
Termination discharge current
tDISCHRG2
Termination time
2
mA
VSHORT < VI(BAT) < VOREG – VRCH
400
μA
VSHORT < VI(BAT) < VOREG – VRCH
1
s
VSHORT < VI(BAT) < VOREG – VRCH
2
mA
VSHORT < VI(BAT) < VOREG – VRCH
0.5
s
Begins after termination detected,
VI(BAT) ≤ VOREG
400
μA
262
ms
OUTPUT CAPACITOR
COUT
Required output ceramic capacitor range
from SNS to PGND, between inductor and
RSNS
CSNS
Required SNS capacitor (ceramic) at SNS
pin
4.7
10
μF
47
μF
0.1
PROTECTION
VOVP
OVP threshold voltage
ILIMIT
Cycle-by-cycle current limit
VSHORT
Short-circuit voltage threshold, BAT
(1)
(2)
Threshold over VOREG to turn off P-channel
MOSFET, STAT1, and STAT2 during charge
or termination states
110
117
2.6
3.6
4.5
A
VI(BAT) falling
1.95
2
2.05
V/cell
121
%VO(REG)
For bq24105 and bq24115 only. RIN is connected between IN and PGND pins and needed to ensure sleep entry.
N-channel always turns on for approximately 60 ns and then turns off if current is too low.
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
9
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
Electrical Characteristics (continued)
TJ = 0°C to 125°C and recommended supply voltage range (unless otherwise stated)
PARAMETER
ISHORT
Short-circuit current
TSHTDWN
Thermal trip
TEST CONDITIONS
MIN
VI(BAT) ≤ VSHORT
TYP
MAX
35
UNIT
65
Thermal hysteresis
mA
165
°C
10
°C
7.6 Dissipation Ratings
θJA
θJC
TA < 40°C
POWER RATING
DERATING FACTOR
ABOVE TA = 40°C
46.87°C/W
2.5°C/W
1.81 W
0.021 W/°C
PACKAGE
RHL
(1)
(1)
This data is based on using the JEDEC High-K board, and the exposed die pad is connected to a copper pad on the board. This is
connected to the ground plane by a 2x3 via matrix.
7.7 Typical Characteristics
100
100
VI = 9 V
90
90
VI = 5 V
Efficiency - %
Efficiency - %
VI = 16 V
80
VI = 16 V
70
V(BAT) = 4.2 V
1-Cell
60
70
V(BAT) = 8.4 V
2-Cell
60
50
50
0
0.5
1
1.5
I(BAT) - Charge Current - A
Figure 1. Efficiency vs Charge Current
10
80
Submit Documentation Feedback
2
0
0.5
1
1.5
2
I(BAT) - Charge Current - A
Figure 2. Efficiency vs Charge Current
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
8 Detailed Description
8.1 Overview
The bqSWITCHER™ supports a precision Li-ion or Li-polymer charging system for single cell or two cell
applications. The device has a battery detect scheme that allows it to automatically detect the presence and
absence of a battery. When the battery is detected, charging begins in one of three phases (depending upon
battery voltage): precharge, constant current (fast-charge current regulation), and constant voltage (fast-charge
voltage regulation). The device will terminate charging when the termination current threshold has been reached
and will begin a recharge cycle when the battery voltage has dropped below the recharge threshold (VRCG).
Precharge, constant current, and termination current can be configured through the ISET1 and ISET2 pins,
allowing for flexibility in battery charging profile. During charging, the integrated fault monitors of the device, such
as battery short detection (VSHORT), thermal shutdown (internal TSHTDWN and TS pin), and safety timer expiration
(TTC pin), ensure battery safety.
bqSWITCHER™ has three status pins (STAT1, STAT2, and PG) to indicate the charging status and input
voltage (AC adapter) status. These pins can be used to drive LEDs or communicate with a host processor.
Precharge
Phase
Voltage Regulation and
Charge Termination Phase
Current Regulation Phase
Regulation Voltage
Regulation Current
Charge Voltage
VLOW
VSHORT
Charge Current
Precharge
and Termination
ISHORT
UDG-04037
Programmable
Safety Timer
Precharge
Timer
Figure 3. Typical Charging Profile
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
11
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
8.2 Functional Block Diagram
Protection PMOS FET is OFF when not charging
or in SLEEP to prevent discharge of battery
when IN < BAT
Rsns
IN
OUT
VIN
Sense FET
IN
Poff VCC PG
CHARGE
SLEEP
10
Synch
V(150 mA)
VCC-6V
PGND
VCC
Sense FET
Vuvlo UVLO/POR
POR
Icntrl
6V
VTSB
VTSB
Co
10 F
Temp
VCC
TG
VCC-6V
V(3.6A)
2.1V
+
Pack-
PGND
VCC
PkILim
Voltage
Reference
Pack+
H
OUT
Isynch
BG
TG
Lo
I
VCC/10
RAMP
(Vpp=VCC/10)
Gate
Drive
to FB
FB
SPIN
ONLY
BG
SYNCH
VCC-6V
MOD
OSC
Q S
MOD
Q R
VCC
OVP
RAMP
PkILim or OVP
TIMEOUT FAULT
SUSPEND
TERM
UVLO/POR
SNS
VCC
+
-
Ibat Reg
+
-
∗
TIMEOUT
COMPENSATION
1k
PG
SUSPEND
SLEEP
+
-
VCC
+
CLAMP
BAT
VCC
VCC
UVLO/
POR
1V
50 mV
VTSB
CE
CE
BAT
Vbat Reg
+
2.1V
Vrch
CONTROL
LOGIC
(STATE
MACHINE)
20uA
20uA
Term_Det
SNS+
VCC
LowV
TERM
SLEEP
SUSPEND
FB
1C
1V
VSHORT
DISCHARGE
Wake
PkILim
CELLS (bq24103/04/13)
FB (bq24105/15)
N/C (bq24100)
VTSB
2C
Vreg
+
-
ISET1
FASTCHG
Disable
WAKE
VCC
FB
SPIN
BAT
BAT_PRS_
disch
CHARGE
VCC
BAT
Charge
RSET1
PRE-CHARGE
STAT1
SYNCH
Charge
STAT2
0.1V
Discharge
SLEEP
SNS
+
1k
-
Vovp
OVP
BAT
OVP
2.1V
TERM
VCC
0.25V
Vrch 30ms
Dgltch
DSABL_TERM
1V
TTC
TIMER CLK
Term &
Timer
Disable
0.75V
TIMER
FF CHAIN
0.5V
PRE-CHG
TIMEOUT
VSS
bqSWITCHER
RESET
FAST CHG
TIMEOUT
LowV 30ms
Dgltch
BAT_PRS_dischg
VSHORT
BAT
+
-
ISET2
PRE-CHG
Disable
RSET2
+
-
FASTCHG
Disable
VTSB
0.1V
30ms
dgltch
Term_Det
VTSB
TS
LTF
SUSPEND
TS
SPIN
TEMP
SUSPEND
HTF
TCO
bq2410x
∗Patent Pending #36889
12
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
8.3 Feature Description
8.3.1 PWM Controller
The bq241xx provides an integrated fixed 1-MHz frequency voltage-mode controller with Feed-Forward function
to regulate charge current or voltage. This type of controller is used to help improve line transient response,
thereby simplifying the compensation network used for both continuous and discontinuous current conduction
operation. The voltage and current loops are internally compensated using a Type-III compensation scheme that
provides enough phase boost for stable operation, allowing the use of small ceramic capacitors with very low
ESR. There is a 0.5 V offset on the bottom of the PWM ramp to allow the device to operate between 0% to 100%
duty cycle.
The internal PWM gate drive can directly control the internal PMOS and NMOS power MOSFETs. The high-side
gate voltage swings from VCC (when off), to VCC-6 (when on and VCC is greater than 6 V) to help reduce the
conduction losses of the converter by enhancing the gate an extra volt beyond the standard 5 V. The low-side
gate voltage swings from 6 V, to turn on the NMOS, down to PGND to turn it off. The bq241xx has two back to
back common-drain P-MOSFETs on the high side. An input P-MOSFET prevents battery discharge when IN is
lower than BAT. The second P-MOSFET behaves as the switching control FET, eliminating the need of a
bootstrap capacitor.
Cycle-by-cycle current limit is sensed through the internal high-side sense FET. The threshold is set to a nominal
3.6 A peak current. The low-side FET also has a current limit that decides if the PWM Controller will operate in
synchronous or non-synchronous mode. This threshold is set to 100 mA and it turns off the low-side NMOS
before the current reverses, preventing the battery from discharging. Synchronous operation is used when the
current of the low-side FET is greater than 100 mA to minimize power losses.
8.3.2 Temperature Qualification
The bqSWITCHER™ continuously monitors battery temperature by measuring the voltage between the TS pin
and VSS pin. A negative temperature coefficient thermistor (NTC) and an external voltage divider typically
develop this voltage. The bqSWITCHER™ compares this voltage against its internal thresholds to determine if
charging is allowed. To initiate a charge cycle, the battery temperature must be within the V(LTF)-to-V(HTF)
thresholds. If battery temperature is outside of this range, the bqSWITCHER™ suspends charge and waits until
the battery temperature is within the V(LTF)-to-V(HTF) range. During the charge cycle (both precharge and fast
charge), the battery temperature must be within the V(LTF)-to-V(TCO) thresholds. If battery temperature is outside of
this range, the bqSWITCHER™ suspends charge and waits until the battery temperature is within the V(LTF)-toV(HTF) range. The bqSWITCHER™ suspends charge by turning off the PWM and holding the timer value (that is,
timers are not reset during a suspend condition). Note that the bias for the external resistor divider is provided
from the VTSB output. Applying a constant voltage between the V(LTF)-to-V(HTF) thresholds to the TS pin disables
the temperature-sensing feature.
VO(VTSB) ´ RTHCOLD ´ RTHHOT ´
1 - 1
VLTF
VHTF
RT2 =
RTHHOT ´
(
VO(VTSB)
-1
VHTF
VO(VTSB)
-1
VLTF
RT1 =
1 +
1
RT2 RTHCOLD
)
- RTHCOLD ´
(
VO(VTSB)
-1
VLTF
)
Where:
VLTF = VO(VTSB) ´ % LTF¸100 / 100
VHTF = VO(VTSB) ´ % HTF¸100 / 100
Copyright © 2004–2015, Texas Instruments Incorporated
(1)
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
13
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
Feature Description (continued)
VCC
Charge Suspend
Charge Suspend
V(LTF)
Temperature Range
to Initiate Charge
V(HTF)
V(TCO)
Charge Suspend
Temperature Range
During Charge Cycle
Charge Suspend
VSS
Figure 4. TS Pin Thresholds
8.3.3 Battery Preconditioning (Precharge)
On power up, if the battery voltage is below the VLOWV threshold, the bqSWITCHER™ applies a precharge
current, IPRECHG, to the battery. This feature revives deeply discharged cells. The bqSWITCHER™ activates a
safety timer, tPRECHG, during the conditioning phase. If the VLOWV threshold is not reached within the timer period,
the bqSWITCHER™ turns off the charger and enunciates FAULT on the STATx pins. In the case of a FAULT
condition, the bqSWITCHER™ reduces the current to IDETECT. IDETECT is used to detect a battery replacement
condition. Fault condition is cleared by POR or battery replacement.
The magnitude of the precharge current, IO(PRECHG), is determined by the value of programming resistor, R(ISET2),
connected to the ISET2 pin.
K (ISET2) V (ISET2)
I O(PRECHG) +
R(ISET2) R(SNS)
ǒ
Ǔ
where
•
•
•
•
RSNS is the external current-sense resistor
V(ISET2) is the output voltage of the ISET2 pin
K(ISET2) is the V/A gain factor
V(ISET2) and K(ISET2) are specified in the Electrical Characteristics table.
(2)
8.3.4 Battery Charge Current
The battery charge current, IO(CHARGE), is established by setting the external sense resistor, R(SNS), and the
resistor, R(ISET1), connected to the ISET1 pin.
In order to set the current, first choose R(SNS) based on the regulation threshold VIREG across this resistor. The
best accuracy is achieved when the VIREG is between 100mV and 200mV.
V IREG
R (SNS) +
I OCHARGE
(3)
If the results is not a standard sense resistor value, choose the next larger value. Using the selected standard
value, solve for VIREG. Once the sense resistor is selected, the ISET1 resistor can be calculated using the
following equation:
14
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
Feature Description (continued)
R ISET1 +
K ISET1
RSNS
V ISET1
I CHARGE
(4)
8.3.5 Battery Voltage Regulation
The voltage regulation feedback occurs through the BAT pin. This input is tied directly to the positive side of the
battery pack. The bqSWITCHER™ monitors the battery-pack voltage between the BAT and VSS pins. The
bqSWITCHER™ is offered in a fixed single-cell voltage version (4.2 V) and as a one-cell or two-cell version
selected by the CELLS input. A low or floating input on the CELLS selects single-cell mode (4.2 V) while a highinput through a resistor selects two-cell mode (8.4 V).
For the bq24105 and bq24115, the output regulation voltage is specified as:
(R1 + R2)
VOREG =
x VIBAT
R2
(5)
where R1 and R2 are resistor divider from BAT to FB and FB to VSS, respectively.
The bq24105 and bq24115 recharge threshold voltage is specified as:
(R1 + R2)
VRCH =
x 50 mV
R2
(6)
8.3.6 Charge Termination and Recharge
The bqSWITCHER™ monitors the charging current during the voltage regulation phase. Once the termination
threshold, ITERM, is detected, the bqSWITCHER™ terminates charge. The termination current level is selected by
the value of programming resistor, R(ISET2), connected to the ISET2 pin.
K (ISET2) V TERM
I TERM +
R(ISET2) R(SNS)
ǒ
Ǔ
where
•
•
•
•
R(SNS) is the external current-sense resistor
VTERM is the output of the ISET2 pin
K(ISET2) is the A/V gain factor
VTERM and K(ISET2) are specified in the Electrical Characteristics table
(7)
As a safety backup, the bqSWITCHER™ also provides a programmable charge timer. The charge time is
programmed by the value of a capacitor connected between the TTC pin and GND by the following formula:
t CHARGE + C(TTC) K(TTC)
where
•
•
A
•
•
•
•
C(TTC) is the capacitor connected to the TTC pin
K(TTC) is the multiplier
(8)
new charge cycle is initiated when one of the following conditions is detected:
The battery voltage falls below the VRCH threshold.
Power-on reset (POR), if battery voltage is below the VRCH threshold
CE toggle
TTC pin, described as follows.
To disable the charge termination and safety timer, the user can pull the TTC input below the VTTC_EN threshold.
Going above this threshold enables the termination and safety timer features and also resets the timer. Tying
TTC high disables the safety timer only.
8.3.7 Sleep Mode
The bqSWITCHER™ enters the low-power sleep mode if the VCC pin is removed from the circuit. This feature
prevents draining the battery during the absence of VCC.
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
15
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
Feature Description (continued)
8.3.8 Charge Status Outputs
The open-drain STAT1 and STAT2 outputs indicate various charger operations as shown in Table 1. These
status pins can be used to drive LEDs or communicate to the host processor. Note that OFF indicates that the
open-drain transistor is turned off.
Table 1. Status Pins Summary
Charge State
STAT1
STAT2
Charge-in-progress
ON
OFF
Charge complete
OFF
ON
Charge suspend, timer fault, overvoltage, sleep mode, battery absent
OFF
OFF
Table 2. Status Pins Summary (bq24104, bq24108 and bq24109 Only)
STAT1
STAT2
Battery absent
Charge State
OFF
OFF
Charge-in-progress
ON
OFF
Charge complete
OFF
ON
Battery over discharge, VI(BAT) < V(SC)
ON/OFF (0.5 Hz)
OFF
Charge suspend (due to TS pin and internal thermal protection)
ON/OFF (0.5 Hz)
OFF
Precharge timer fault
ON/OFF (0.5 Hz)
OFF
Fast charge timer fault
ON/OFF (0.5 Hz)
OFF
OFF
OFF
Sleep mode
8.3.9 PG Output
The open-drain PG (power good) indicates when the AC-to-DC adapter (that is, VCC) is present. The output turns
on when sleep-mode exit threshold, VSLP-EXIT, is detected. This output is turned off in the sleep mode. The PG pin
can be used to drive an LED or communicate to the host processor.
8.3.10 CE Input (Charge Enable)
The CE digital input is used to disable or enable the charge process. A low-level signal on this pin enables the
charge and a high-level VCC signal disables the charge. A high-to-low transition on this pin also resets all timers
and fault conditions. Note that the CE pin cannot be pulled up to VTSB voltage. This may create power-up
issues.
8.3.11 Timer Fault Recovery
As shown in Figure 4, bqSWITCHER™ provides a recovery method to deal with timer fault conditions. The
following summarizes this method.
Condition 1 VI(BAT) above recharge threshold (VOREG - VRCH) and timeout fault occurs.
Recovery method: bqSWITCHER™ waits for the battery voltage to fall below the recharge threshold. This could
happen as a result of a load on the battery, self-discharge or battery removal. Once the battery falls below the
recharge threshold, the bqSWITCHER™ clears the fault and enters the battery absent detection routine. A POR
or CE toggle also clears the fault.
Condition 2 Charge voltage below recharge threshold (VOREG – VRCH) and timeout fault occurs
Recovery method: In this scenario, the bqSWITCHER™ applies the IDETECT current. This small current is used to
detect a battery removal condition and remains on as long as the battery voltage stays below the recharge
threshold. If the battery voltage goes above the recharge threshold, then the bqSWITCHER™ disables the
IDETECT current and executes the recovery method described in Condition 1. Once the battery falls below the
recharge threshold, the bqSWITCHER™ clears the fault and enters the battery absent detection routine. A POR
or CE toggle also clears the fault.
16
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
8.3.12 Output Overvoltage Protection (Applies to All Versions)
The bqSWITCHER™ provides a built-in overvoltage protection to protect the device and other components
against damages if the battery voltage gets too high, as when the battery is suddenly removed. When an
overvoltage condition is detected, this feature turns off the PWM and STATx pins. The fault is cleared once VIBAT
drops to the recharge threshold (VOREG – VRCH).
8.3.13 Functional Description For System-Controlled Version (bq2411x)
For applications requiring charge management under the host system control, the bqSWITCHER™ (bq2411x)
offers a number of control functions. The following section describes these functions.
8.3.14 Precharge and Fast-Charge Control
A low-level signal on the CMODE pin forces the bqSWITCHER™ to charge at the precharge rate set on the
ISET2 pin. A high-level signal forces charge at fast-charge rate as set by the ISET1 pin. If the battery reaches
the voltage regulation level, VOREG, the bqSWITCHER™ transitions to voltage regulation phase regardless of the
status of the CMODE input.
8.3.15 Charge Termination and Safety Timers
The charge timers and termination are disabled in the system-controlled versions of the bqSWITCHER™. The
host system can use the CE input to enable or disable charge. When an overvoltage condition is detected, the
charger process stops, and all power FETs are turned off.
8.3.16 Battery Detection
For applications with removable battery packs, bqSWITCHER™ provides a battery absent detection scheme to
reliably detect insertion and/or removal of battery packs.
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
17
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
POR or VRCH
Detection routine runs on power up
and if VBAT drops below refresh
threshold due to removing battery
or discharging battery.
Yes
Enable
I(DETECT)
for t(DETECT)
VI(BAT)<V(LOWV)
No
BATTERY
PRESENT,
Begin Charge
No
BATTERY
PRESENT,
Begin Charge
Yes
Apply I(WAKE)
for t(WAKE)
VI(BAT) >
VO(REG)
-VRCH
Yes
BATTERY
ABSENT
Figure 5. Battery Absent Detection for bq2410x ICs only
The voltage at the BAT pin is held above the battery recharge threshold, VOREG – VRCH, by the charged battery
following fast charging. When the voltage at the BAT pin falls to the recharge threshold, either by a load on the
battery or due to battery removal, the bqSWITCHER™ begins a battery absent detection test. This test involves
enabling a detection current, IDISCHARGE1, for a period of tDISCHARGE1 and checking to see if the battery voltage is
below the short circuit threshold, VSHORT. Following this, the wake current, IWAKE is applied for a period of tWAKE
and the battery voltage is checked again to ensure that it is above the recharge threshold. The purpose of this
current is to attempt to close an open battery pack protector, if one is connected to the bqSWITCHER™.
Passing both of the discharge and charge tests indicates a battery absent fault at the STAT pins. Failure of either
test starts a new charge cycle. For the absent battery condition, typically the voltage on the BAT pin rises and
falls between 0V and VOVPthresholds indefinitely.
18
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
VBAT
Battery
Connected
VOREG
No
Battery
Detected
2V/cell
No
Battery
Detected
Yes
Battery
Detected
IWAKE
IBAT
- IDISCHRG1
t DISCHRG1
tWAKE
t DISCHRG1
Figure 6. Battery Detect Timing Diagram
8.3.16.1 Battery Detection Example
In order to detect a no battery condition during the discharge and wake tests, the maximum output capacitance
should not exceed the following:
a. Discharge (IDISCHRG1 = 400 μA, tDISCHRG1 = 1s, VSHORT = 2V)
I
´t
CMAX _ DIS = DISCHRG1 DISCHRG1
VOREG - VSHORT
CMAX _ DIS =
400 mA ´ 1 s
4.2 V - 2 V
CMAX _ DIS = 182 mF
(9)
b. Wake (IWAKE = 2 mA, tWAKE = 0.5 s, VOREG – VRCH = 4.1V)
IWAKE ´ t WAKE
CMAX _ WAKE =
(VOREG - VRCH ) - 0 V
CMAX _ WAKE =
2 mA ´ 0.5 s
(4.2 V - 0.1 V ) - 0 V
CMAX _ WAKE = 244 mF
(10)
Based on these calculations the recommended maximum output capacitance to ensure proper operation of the
battery detection scheme is 100 μF which will allow for process and temperature variations.
Figure 7 shows the battery detection scheme when a battery is inserted. Channel 3 is the output signal and
Channel 4 is the output current. The output signal switches between VOREG and GND until a battery is inserted.
Once the battery is detected, the output current increases from 0 A to 1.3 A, which is the programmed charge
current for this application.
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
19
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
Figure 7. Battery Detection Waveform When a Battery is Inserted
Figure 8 shows the battery detection scheme when a battery is removed. Channel 3 is the output signal and
Channel 4 is the output current. When the battery is removed, the output signal goes up due to the stored energy
in the inductor and it crosses the VOREG – VRCH threshold. At this point the output current goes to 0 A and the IC
terminates the charge process and turns on the IDISCHG2 for tDISCHG2. This causes the output voltage to fall down
below the VOREG – VRCHG threshold triggering a Battery Absent condition and starting the battery detection
scheme.
Figure 8. Battery Detection Waveform When a Battery is Removed
8.3.17 Current Sense Amplifier
BQ241xx family offers a current sense amplifier feature that translates the charge current into a DC voltage.
Figure 9 is a block diagram of this feature.
20
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
OUT
ICHARGE
SNS
RSNS
+
KISET2
BAT
+
-
+
FASTCHG
Disable
ISET2
RISET2
Figure 9. Current Sense Amplifier
The voltage on the ISET2 pin can be used to calculate the charge current. Equation 11 shows the relationship
between the ISET2 voltage and the charge current:
VISET2 K(ISET2)
I CHARGE +
R SNS R ISET2
(11)
This feature can be used to monitor the charge current (see Figure 10) during the current regulation phase
(Fastcharge only) and the voltage regulation phase. The schematic for the application circuit for this waveform is
shown in Figure 13.
CH3 = Inductor Current
CH3
500 mA/div
CH1 = ISET2
CH3
0A
CH1
200 mV/div
CH2 = OUT
CH1
0V
CH2
16 V
CH2
10 V/div
t = Time = 200 ms/div
Figure 10. Current Sense Amplifier Charge Current Waveform
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
21
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
8.4 Device Functional Modes
Figure 11 shows the operational flow chart for a stand-alone charge operation.
POR
Check for Battery
Presence
Battery
Detect?
No
Indicate BATTERY
ABSENT
Yes
Suspend Charge
TS Pin
in LTF to HTF
Range?
No
Indicate CHARGE
SUSPEND
Yes
VBAT <VLOWV
Yes
Regulate
IPRECHG
Reset and Start
T30min timer
Indicate ChargeIn-Progress
No
Suspend Charge
Reset and Start
FSTCHG timer
TS pin
in LTF to TCO
range?
Regulate
Current or Voltage
Yes
No
Indicate CHARGE
SUSPEND
No
TS pin
in LTF to HTF
range?
Indicate ChargeIn-Progress
No
VBAT <VLOWV
Suspend Charge
TS Pin
in LTF to TCO
Range?
Yes
Yes
No
Indicate CHARGE
SUSPEND
Yes
No
T30min
Expired?
No
TS pin
in LTF to HTF
range?
FSTCHG Timer
Expired?
No
Yes
Yes
Yes
VBAT <VLOWV
Yes
No
- Fault Condition
- Enable I DETECT
No
ITERM detection?
Indicate Fault
No
Yes
Battery
Replaced?
(Vbat < Vrch?)
- Turn Off Charge
- Enable I DISCHG for
tDISCHG2
Indicate ChargeIn-Progress
*NOTE: If the TTC pin is
pulled low, the safety timer
and termination are
disabled; the charger
continues to regulate, and
the STAT pins indicate
charge in progress.
If the TTC pin is pulled high
(VTSB), only the safety
timer is disabled
(termination is normal).
Yes
Charge Complete
VBAT < VRCH ?
No
Indicate DONE
*
Battery Removed
Yes
Indicate BATTERY
ABSENT
Figure 11. Stand-Alone Version Operational Flow Chart
22
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
Device Functional Modes (continued)
Figure 12 shows the operational flow chart for a system-controlled charge operation.
POR
SLEEP MODE
No
Vcc > VI(BAT)
Checked at All
Times
No
Indicate SLEEP
MODE
Yes
/CE=Low
Yes
Regulate
IO(PRECHG)
CMODE=Low
Yes
Indicate ChargeIn-Progress
No
Yes
/CE=High
No
Regulate Current
or Voltage
Indicate ChargeIn-Progress
Yes
Yes
CMODE=High
or
VIBAT in VREG
Yes
No
CMODE=Low
No
No
/CE=High
Yes
Turn Off Charge
Indicate DONE
Yes
No
/CE=Low
Yes
Figure 12. System-Controlled Operational Flow Chart
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
23
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
9 Application and Implementation
NOTE
Information in the following applications sections is not part of the TI component
specification, and TI does not warrant its accuracy or completeness. TI’s customers are
responsible for determining suitability of components for their purposes. Customers should
validate and test their design implementation to confirm system functionality.
9.1 Application Information
The bqSWITCHER™ battery charger supports precision Li-ion or Li-polymer charging system for single- or twocell application. The design example below shows the design consideration for a 1-cell application.
9.2 Typical Application
LOUT
BQ24100
VIN
CIN
1.5 KW
10 mF
1.5 KW
Adapter
Present
1.5 KW
Done
Charge
3
IN
OUT 1
4
IN
OUT 20
6
VCC
2
STAT1 PGND 18
RSNS
10 mH
COUT
D1
PGND 17
Battery
Pack
0.1W
10 mF
Pack+
Pack-
MMBZ18VALT1
103AT
19 STAT2
5
PG
7
TTC
SNS 15
BAT 14
ISET1 8
7.5 KW RISET1
VTSB
7.5 KW
CTTC
16 CE
ISET2 9
0.1 mF
10 VSS
13 NC
9.31 KW
RT1
442 KW
RT2
RISET2
TS 12
VTSB 11
0.1 mF
0.1 mF
0.1 mF
Figure 13. Stand-Alone, 1-Cell Application
9.2.1 Design Requirements
For this design example, use the parameters listed in Table 3.
Table 3. Design Parameters
DESIGN PARAMETER
AC adapter voltage (VIN)
Battery charge voltage (number of cells in series)
EXAMPLE VALUE
16 V
4.2 V (1 cell)
Battery charge current (during fast charge phase)
1.33 A
Precharge and termination current
0.133 A
Safety timer
5 hours
Inductor ripple current
Charging temperature range
24
Submit Documentation Feedback
30% of fast charge current (0.4 A)
0°C to 45°C
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
9.2.2 Detailed Design Procedure
• VIN = 16 V
• VBAT = 4.2 V (1-Cell)
• ICHARGE = 1.33 A
• IPRECHARGE = ITERM = 133 mA
• Safety Timer = 5 hours
• Inductor Ripple Current = 30% of Fast Charge Current
• Initiate Charge Temperature = 0°C to 45°C
1. Determine the inductor value (LOUT) for the specified charge current ripple:
DI L + I CHARGE I CHARGERipple
L OUT +
L OUT +
ǒVINMAX * VBATǓ
VBAT
ƒ
V INMAX
DI L
4.2 (16 * 4.2)
(1.1 106) (1.33
16
0.3)
L OUT + 7.06 mH
(12)
Set the output inductor to standard 10 μH. Calculate the total ripple current with using the 10 μH inductor:
DI L +
DI L +
ǒVINMAX * VBATǓ
VBAT
ƒ
V INMAX
16
LOUT
4.2 (16 * 4.2)
(1.1 106) (10
10 *6)
DI L + 0.282 A
(13)
Calculate the maximum output current (peak current):
DI
I LPK + I OUT ) L
2
I LPK + 1.33 ) 0.282
2
I LPK + 1.471 A
(14)
Use standard 10 μH inductor with a saturation current higher than 1.471 A. (that is, Sumida CDRH74-100)
2. Determine the output capacitor value (OUT) using 16 kHz as the resonant frequency:
1
ƒo +
Ǹ
2p LOUT COUT
1
C OUT +
4p 2
ƒo
C OUT +
4p 2
(16
2
L OUT
1
10 3)2
(10
10 *6)
C OUT + 9.89 mF
(15)
Use standard value 10 μF, 25 V, X5R, ±20% ceramic capacitor (that is, Panasonic 1206 ECJ-3YB1E106M
3. Determine the sense resistor using the following equation:
V
R SNS + RSNS
I CHARGE
(16)
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
25
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
In order to get better current regulation accuracy (±10%), let VRSNS be between 100 mV and 200 mV. Use
VRSNS = 100 mV and calculate the value for the sense resistor.
R SNS + 100 mV
1.33 A
R SNS + 0.075 W
(17)
This value is not standard in resistors. If this happens, then choose the next larger value which in this case is
0.1 Ω. Using the same Equation 15 the actual VRSNS will be 133 mV. Calculate the power dissipation on the
sense resistor:
P RSNS + I CHARGE
P RSNS + 1.332
2
R SNS
0.1
P RSNS + 176.9 mW
(18)
Select standard value 100 mΩ, 0.25 W 0805, 1206 or 2010 size, high precision sensing resistor. (that is.,
Vishay CRCW1210-0R10F)
4. Determine ISET 1 resistor using the following equation:
K
V ISET1
R ISET1 + ISET1
RSNS I CHARGE
R ISET1 + 1000 1.0
0.1 1.33
R ISET1 + 7.5 kW
(19)
Select standard value 7.5 kΩ, 1/16W ±1% resistor (that is, Vishay CRCWD0603-7501-F)
5. Determine ISET 2 resistor using the following equation:
KISET2 VISET2
R ISET2 +
RSNS I PRECHARGE
R ISET2 + 1000 0.1
0.1 0.133
R ISET2 + 7.5 kW
(20)
Select standard value 7.5 kΩ, 1/16W ±1% resistor (that is, Vishay CRCWD0603-7501-F)
6. Determine TTC capacitor (TTC) for the 5.0 hours safety timer using the following equation:
t
C TTC + CHARGE
K TTC
C TTC + 300 m
2.6 mńnF
C TTC + 115.4 nF
(21)
Select standard value 100 nF, 16V, X7R, ±10% ceramic capacitor (that is, Panasonic ECJ-1VB1C104K).
Using this capacitor the actual safety timer will be 4.3 hours.
7. Determine TS resistor network for an operating temperature range from 0°C to 45°C.
26
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
VTSB
RT1
TS
RTH
RT2
103AT
Figure 14. TS Resistor Network
Assuming a 103AT NTC Thermistor on the battery pack, determine the values for RT1 and RT2 using the
following equations:
VO(VTSB) ´ RTHCOLD ´ RTHHOT ´
1 - 1
VLTF
VHTF
RT2 =
RTHHOT ´
(
VO(VTSB)
-1
VHTF
VO(VTSB)
-1
VLTF
RT1 =
1 +
1
RT2 RTHCOLD
)
- RTHCOLD ´
(
VO(VTSB)
-1
VLTF
)
Where:
VLTF = VO(VTSB) ´ % LTF¸100 / 100
VHTF = VO(VTSB) ´ % HTF¸100 / 100
(22)
RTH COLD + 27.28 kW
RTH HOT + 4.912 kW
RT1 + 9.31 kW
RT2 + 442 kW
(23)
9.2.2.1 Inductor, Capacitor, and Sense Resistor Selection Guidelines
The bqSWITCHER™ provides internal loop compensation. With this scheme, best stability occurs when LC
resonant frequency, fo is approximately 16 kHz (8 kHz to 32 kHz). Use Equation 24 to calculate the value of the
output inductor and capacitor. Table 4 provides a summary of typical component values for various charge rates.
1
f0 +
Ǹ
2p
L OUT C OUT
(24)
Table 4. Output Components Summary
CHARGE CURRENT
0.5 A
1A
Output inductor, LOUT
22 μH
10 μH
4.7 μH
Output capacitor, COUT
4.7 μF
10 μF
22 μF (or 2 × 10 μF) ceramic
Sense resistor, R(SNS)
0.2 Ω
0.1 Ω
0.05 Ω
Copyright © 2004–2015, Texas Instruments Incorporated
2A
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
27
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
9.2.3 Application Curve
100
90
Efficiency - %
VI = 5 V
80
VI = 16 V
70
V(BAT) = 4.2 V
1-Cell
60
50
0
0.5
1
2
1.5
I(BAT) - Charge Current - A
Figure 15. Efficiency vs Charge Current
9.3 System Examples
BQ24103
BQ24104
VIN
CIN
1.5 KW
10 mF
1.5 KW
Adapter
Present
1.5 KW
Done
Charge
LOUT
3
IN
OUT 1
4
IN
OUT 20
6
VCC
RSNS
10 mH
COUT
D1
Battery
Pack
0.1W
10 mF
Pack-
MMBZ18VALT1
PGND 17
(see Note A)
2
Pack+
103AT
STAT1 PGND 18
19 STAT2
5
PG
7
TTC
SNS 15
BAT 14
ISET1 8
7.5 KW RISET1
VTSB
7.5 KW
CTTC
ISET2 9
16 CE
0.1 mF
RT1
442 KW
RT2
TS 12
10 VSS
0.1 mF
9.31 KW
RISET2
13 CELLS
VTSB 11
0.1 mF
0.1 mF
VIN
10 kW
Zener diode not needed for bq24103A and bq24104.
Figure 16. Stand-Alone, 2-Cell Application
28
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
System Examples (continued)
LOUT
BQ24105
VIN
1.5 KW
10 mF
CIN
1.5 KW
Adapter
Present
1.5 KW
Done
Charge
3
IN
OUT 1
4
IN
OUT 20
6
VCC
RSNS
10 mH
COUT
D1
Battery
Pack
Pack+
0.1W
10 mF
Pack-
MMBZ18VALT1
PGND 17
103AT
2
STAT1 PGND 18
19 STAT2
5
PG
7
TTC
SNS 15
BAT 14
7.5 KW RISET1
ISET1 8
VTSB
7.5 KW
CTTC
16 CE
ISET2 9
10 VSS
0.1 mF
9.31 KW
RT1
442 KW
RT2
RISET2
0.1 mF
TS 12
13 FB
VTSB 11
0.1 mF
301 KW
0.1 mF
100 KW
Figure 17. Stand-Alone, 2-Cell Application
BQ24113,
BQ24113A
VIN
3
IN
4
IN
6
VCC
2
STAT1 PGND 18
LOUT
OUT 1
10 mH
0.1 mF
CIN
10 mF
RSNS
OUT 20
D1
COUT
0.1W
10 mF
Pack+
Pack-
MMBZ18VALT1
PGND 17
(see Note A)
19 NC
Battery
Pack
103AT
SNS 15
5
PG
7
CMODE ISET1 8
BAT 14
7.5 KW RISET1
VTSB
7.5 KW
16 CE
10 VSS
13 CELLS
ISET2 9
9.31 KW
RT1
442 KW
RT2
RISET2
TS 12
VTSB 11
0.1 mF
0.1 mF
TO HOST CONTROLLER
Zener diode not needed for bq24113A.
Figure 18. System-Controlled Application
Figure 19 shows charging a battery and powering system without affecting battery charge and termination.
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
29
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
System Examples (continued)
RSYS
LOUT
BQ24100
VIN
CIN
1.5 KW
10 mF
1.5 KW
Adapter
Present
1.5 KW
Done
Charge
3
IN
OUT 1
4
IN
OUT 20
6
VCC
2
STAT1 PGND 18
PGND 17
RSNS
10 mH
D1
COUT
0.1W
Battery
Pack
Pack+
10 mF
Pack-
MMBZ18VALT1
103AT
19 STAT2
5
PG
7
TTC
SNS 15
BAT 14
7.5 KW
VTSB
ISET1 8
7.5 KW
CTTC
16 CE
9.31 KW
ISET2 9
0.1 mF
10 VSS
0.1 mF
13 NC
TS 12
VTSB 11
442 KW
0.1 mF
0.1 mF
Figure 19. Application Circuit for Charging a Battery and Powering a System
Without Affecting Termination
The bqSWITCHER™ was designed as a stand-alone battery charger but can be easily adapted to power a
system load, while considering a few minor issues.
Advantages:
1. The charger controller is based only on what current goes through the current-sense resistor (so precharge,
constant current, and termination all work well), and is not affected by the system load.
2. The input voltage has been converted to a usable system voltage with good efficiency from the input.
3. Extra external FETs are not needed to switch power source to the battery.
4. The TTC pin can be grounded to disable termination and keep the converter running and the battery fully
charged, or let the switcher terminate when the battery is full and then run off of the battery via the sense
resistor.
Other Issues:
1. If the system load current is large (≥ 1 A), the IR drop across the battery impedance causes the battery
voltage to drop below the refresh threshold and start a new charge. The charger would then terminate due to
low charge current. Therefore, the charger would cycle between charging and termination. If the load is
smaller, the battery would have to discharge down to the refresh threshold resulting in a much slower
cycling. Note that grounding the TTC pin keeps the converter on continuously.
2. If TTC is grounded, the battery is kept at 4.2 V (not much different than leaving a fully charged battery set
unloaded).
3. Efficiency declines 2-3% hit when discharging through the sense resistor to the system.
The following system example shows charging a battery and powering system without affecting battery charge
and termination.
30
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
System Examples (continued)
LOUT
BQ24105
VIN
CIN
1.5 KW
10 mF
1.5 KW
Adapter
Present
1.5 KW
Done
Charge
3
IN
OUT 1
4
IN
OUT 20
6
VCC
RSNS
10 mH
D1
COUT
Battery
Pack
Pack+
0.1W
10 mF
Pack-
MMBZ18VALT1
PGND 17
103AT
2
STAT1 PGND 18
19 STAT2
5
PG
7
TTC
SNS 15
BAT 14
ISET1 8
7.5 KW RISET1
VTSB
20 KW
CTTC
16 CE
ISET2 9
0.1 mF
10 VSS
0.1 mF
13 FB
9.31 KW
RT1
442 KW
RT2
RISET2
TS 12
VTSB 11
0.1 mF
0.1 mF
143 KW
200 KW
Figure 20. 1-Cell LiFePO4 Application
The LiFePO4 battery has many unique features such as a high thermal runaway temperature, discharge current
capability, and charge current. These special features make it attractive in many applications such as power
tools. The recommended charge voltage is 3.6 V and termination current is 50 mA. Figure 20 shows an
application circuit for charging one cell LiFePO4 using bq24105. The charge voltage is 3.6 V and recharge
voltage is 3.516 V. The fast charging current is set to 1.33 A while the termination current is 50 mA. This circuit
can be easily changed to support two or three cell applications. However, only 84 mV difference between
regulation set point and rechargeable threshold makes it frequently enter into recharge mode when small load
current is applied. This can be solved by lower down the recharge voltage threshold to 200 mV to discharge
more energy from the battery before it enters recharge mode again. See the application report, Using the
bq24105/25 to Charge LiFePO4 Battery, SLUA443, for additional details. The recharge threshold should be
selected according to real application conditions.
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
31
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
10 Power Supply Recommendations
For proper operation of bqSWITCHER™, VCC and IN (tied together) must be from 4.35 V to 16 V. Power limit
for the input supply must be greater than the maximum power required for charging the battery (plus any
additional load on the output of the switch-mode converter).
11 Layout
11.1 Layout Guidelines
It is important to pay special attention to the PCB layout. The following provides some guidelines:
• To obtain optimal performance, the power input capacitors, connected from input to PGND, should be placed
as close as possible to the bqSWITCHER™. The output inductor should be placed directly above the IC and
the output capacitor connected between the inductor and PGND of the IC. The intent is to minimize the
current path loop area from the OUT pin through the LC filter and back to the GND pin. The sense resistor
should be adjacent to the junction of the inductor and output capacitor. Route the sense leads connected
across the R(SNS) back to the IC, close to each other (minimize loop area) or on top of each other on adjacent
layers (do not route the sense leads through a high-current path). Use an optional capacitor downstream from
the sense resistor if long (inductive) battery leads are used.
• Place all small-signal components (CTTC, RSET1/2 and TS) close to their respective IC pin (do not place
components such that routing interrupts power stage currents). All small control signals should be routed
away from the high current paths.
• The PCB should have a ground plane (return) connected directly to the return of all components through vias
(3 vias per capacitor for power-stage capacitors, 3 vias for the IC PGND, 1 via per capacitor for small-signal
components). A star ground design approach is typically used to keep circuit block currents isolated (highpower/low-power small-signal) which reduces noise-coupling and ground-bounce issues. A single ground
plane for this design gives good results. With this small layout and a single ground plane, there is not a
ground-bounce issue, and having the components segregated minimizes coupling between signals.
• The high-current charge paths into IN and from the OUT pins must be sized appropriately for the maximum
charge current in order to avoid voltage drops in these traces. The PGND pins should be connected to the
ground plane to return current through the internal low-side FET. The thermal vias in the IC PowerPAD™
provide the return-path connection.
• The bqSWITCHER™ is packaged in a thermally enhanced MLP package. The package includes a thermal
pad to provide an effective thermal contact between the IC and the PCB. Full PCB design guidelines for this
package are provided in the application report entitled: QFN/SON PCB Attachment, SLUA271. Six 10-13 mil
vias are a minimum number of recommended vias, placed in the IC's power pad, connecting it to a ground
thermal plane on the opposite side of the PWB. This plane must be at the same potential as VSS and PGND
of this IC.
• See user's guide SLUU200 for an example of a good layout.
WAVEFORMS: All waveforms are taken at Lout (IC Out pin). VIN = 7.6 V and the battery was set to 2.6 V, 3.5 V,
and 4.2 V for the three waveforms. When the top switch of the converter is on, the waveform is at ~7.5 V, and
when off, the waveform is near ground. Note that the ringing on the switching edges is small. This is due to a
tight layout (minimized loop areas), a shielded inductor (closed core), and using a low-inductive scope ground
lead (that is, short with minimum loop).
Precharge: The current is low in precharge; so, the bottom synchronous FET turns off after its minimum on-time
which explains the step between ≉0 V and -0.5 V. When the bottom FET and top FET are off, the current
conducts through the body diode of the bottom FET which results in a diode drop below the ground potential.
The initial negative spike is the delay turning on the bottom FET, which is to prevent shoot-through current as the
top FET is turning off.
Fast Charge: This is captured during the constant-current phase. The two negative spikes are the result of the
short delay when switching between the top and bottom FETs. The break-before-make action prevents current
shoot-through and results in a body diode drop below ground potential during the break time.
32
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
Layout Guidelines (continued)
Charge during Voltage Regulation and Approaching Termination: Note that this waveform, Figure 23, is similar to
the precharge waveform, Figure 21. The difference is that the battery voltage is higher so the duty cycle is
slightly higher. The bottom FET stays on longer because there is more of a current load than during precharge; it
takes longer for the inductor current to ramp down to the current threshold where the synchronous FET is
disabled.
Figure 21. Precharge Waveform
Figure 22. Fast Charge Waveform
Figure 23. Voltage Regulation and Approaching Termination Waveform
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
33
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
11.2 Layout Example
Figure 24. bq241xx PCB Layout
11.3 Thermal Considerations
The SWITCHER is packaged in a thermally enhanced MLP package. The package includes a thermal pad to
provide an effective thermal contact between the IC and the printed circuit board (PCB). Full PCB design
guidelines for this package are provided in the application report entitled: QFN/SON PCB Attachment, SLUA271.
The most common measure of package thermal performance is thermal impedance (θJA) measured (or modeled)
from the chip junction to the air surrounding the package surface (ambient). The mathematical expression for θJA
is:
T * TA
q (JA) + J
P
where
•
•
•
TJ = chip junction temperature
TA = ambient temperature
P = device power dissipation
(25)
Factors that can greatly influence the measurement and calculation of θJA include:
• Whether or not the device is board mounted
• Trace size, composition, thickness, and geometry
• Orientation of the device (horizontal or vertical)
• Volume of the ambient air surrounding the device under test and airflow
• Whether other surfaces are in close proximity to the device being tested
The device power dissipation, P, is a function of the charge rate and the voltage drop across the internal power
FET. It can be calculated from the following equation:
P = (VIN ´ lIN ) - (VBAT ´ IBAT )
(26)
Due to the charge profile of Li-xx batteries, the maximum power dissipation is typically seen at the beginning of
the charge cycle when the battery voltage is at its lowest. (See Figure 3).
34
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
www.ti.com
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
12 Device and Documentation Support
12.1 Device Support
12.1.1 Third-Party Products Disclaimer
TI'S PUBLICATION OF INFORMATION REGARDING THIRD-PARTY PRODUCTS OR SERVICES DOES NOT
CONSTITUTE AN ENDORSEMENT REGARDING THE SUITABILITY OF SUCH PRODUCTS OR SERVICES
OR A WARRANTY, REPRESENTATION OR ENDORSEMENT OF SUCH PRODUCTS OR SERVICES, EITHER
ALONE OR IN COMBINATION WITH ANY TI PRODUCT OR SERVICE.
12.2 Documentation Support
12.2.1 Related Documentation
For related documentation see the following:
• bq241xx User's Guide, SLUU200
• QFN/SON PCB Attachment, SLUA271
• Using the bq24105/25 to Charge LiFePO4 Battery, SLUA443
12.3 Related Links
The table below lists quick access links. Categories include technical documents, support and community
resources, tools and software, and quick access to sample or buy.
Table 5. Related Links
PARTS
PRODUCT FOLDER
SAMPLE & BUY
TECHNICAL
DOCUMENTS
TOOLS &
SOFTWARE
SUPPORT &
COMMUNITY
bq24100
Click here
Click here
Click here
Click here
Click here
bq24103
Click here
Click here
Click here
Click here
Click here
bq24103A
Click here
Click here
Click here
Click here
Click here
bq24104
Click here
Click here
Click here
Click here
Click here
bq24105
Click here
Click here
Click here
Click here
Click here
bq24108
Click here
Click here
Click here
Click here
Click here
bq24109
Click here
Click here
Click here
Click here
Click here
bq24113
Click here
Click here
Click here
Click here
Click here
bq24113A
Click here
Click here
Click here
Click here
Click here
bq24115
Click here
Click here
Click here
Click here
Click here
12.4 Community Resources
The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective
contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of
Use.
TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration
among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help
solve problems with fellow engineers.
Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and
contact information for technical support.
12.5 Trademarks
bqSWITCHER, PowerPAD, E2E are trademarks of Texas Instruments.
All other trademarks are the property of their respective owners.
Copyright © 2004–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
35
bq24100, bq24103, bq24103A, bq24104, bq24105
bq24108, bq24109, bq24113, bq24113A, bq24115
SLUS606P – JUNE 2004 – REVISED NOVEMBER 2015
www.ti.com
12.6 Electrostatic Discharge Caution
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
12.7 Glossary
SLYZ022 — TI Glossary.
This glossary lists and explains terms, acronyms, and definitions.
13 Mechanical, Packaging, and Orderable Information
The following pages include mechanical, packaging, and orderable information. This information is the most
current data available for the designated devices. This data is subject to change without notice and revision of
this document. For browser-based versions of this data sheet, refer to the left-hand navigation.
36
Submit Documentation Feedback
Copyright © 2004–2015, Texas Instruments Incorporated
Product Folder Links: bq24100 bq24103 bq24103A bq24104 bq24105 bq24108 bq24109 bq24113 bq24113A
bq24115
PACKAGE OPTION ADDENDUM
www.ti.com
15-Apr-2017
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
MSL Peak Temp
(2)
(6)
(3)
Op Temp (°C)
Device Marking
(4/5)
BQ24100RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIA
BQ24100RHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIA
BQ24103ARHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKO
BQ24103ARHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKO
BQ24103ARHLT
ACTIVE
VQFN
RHL
20
250
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKO
BQ24103ARHLTG4
ACTIVE
VQFN
RHL
20
250
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKO
BQ24103RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CID
BQ24103RHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CID
BQ24104RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
NXW
BQ24104RHLT
ACTIVE
VQFN
RHL
20
250
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
NXW
BQ24105RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIF
BQ24105RHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIF
BQ24108RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIU
BQ24108RHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIU
BQ24109RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 125
CDY
BQ24109RHLT
ACTIVE
VQFN
RHL
20
250
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 125
CDY
BQ24113ARHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKF
Addendum-Page 1
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
Orderable Device
15-Apr-2017
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
MSL Peak Temp
(2)
(6)
(3)
Op Temp (°C)
Device Marking
(4/5)
BQ24113ARHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKF
BQ24113ARHLT
ACTIVE
VQFN
RHL
20
250
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKF
BQ24113ARHLTG4
ACTIVE
VQFN
RHL
20
250
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CKF
BQ24113RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIJ
BQ24113RHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIJ
BQ24115RHLR
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIL
BQ24115RHLRG4
ACTIVE
VQFN
RHL
20
3000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-2-260C-1 YEAR
-40 to 85
CIL
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5)
Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
Addendum-Page 2
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
15-Apr-2017
(6)
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF BQ24105 :
• Automotive: BQ24105-Q1
NOTE: Qualified Version Definitions:
• Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects
Addendum-Page 3
PACKAGE MATERIALS INFORMATION
www.ti.com
12-May-2015
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
BQ24100RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24103ARHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24103ARHLT
VQFN
RHL
20
250
180.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24103RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24104RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24104RHLT
VQFN
RHL
20
250
180.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24105RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.3
8.0
12.0
Q1
BQ24105RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24108RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24109RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24109RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.3
8.0
12.0
Q1
BQ24109RHLT
VQFN
RHL
20
250
180.0
12.4
3.8
4.8
1.3
8.0
12.0
Q1
BQ24109RHLT
VQFN
RHL
20
250
180.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24113ARHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24113ARHLT
VQFN
RHL
20
250
180.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24113RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
BQ24115RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.3
8.0
12.0
Q1
BQ24115RHLR
VQFN
RHL
20
3000
330.0
12.4
3.8
4.8
1.6
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
12-May-2015
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
BQ24100RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24103ARHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24103ARHLT
VQFN
RHL
20
250
210.0
185.0
35.0
BQ24103RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24104RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24104RHLT
VQFN
RHL
20
250
210.0
185.0
35.0
BQ24105RHLR
VQFN
RHL
20
3000
370.0
355.0
55.0
BQ24105RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24108RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24109RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24109RHLR
VQFN
RHL
20
3000
370.0
355.0
55.0
BQ24109RHLT
VQFN
RHL
20
250
195.0
200.0
45.0
BQ24109RHLT
VQFN
RHL
20
250
210.0
185.0
35.0
BQ24113ARHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24113ARHLT
VQFN
RHL
20
250
210.0
185.0
35.0
BQ24113RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
BQ24115RHLR
VQFN
RHL
20
3000
370.0
355.0
55.0
BQ24115RHLR
VQFN
RHL
20
3000
367.0
367.0
35.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its
semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers
should obtain the latest relevant information before placing orders and should verify that such information is current and complete.
TI’s published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated
circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and
services.
Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is
accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced
documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements
different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the
associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Buyers and others who are developing systems that incorporate TI products (collectively, “Designers”) understand and agree that Designers
remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have
full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products
used in or for Designers’ applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with
respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous
consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and
take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will
thoroughly test such applications and the functionality of such TI products as used in such applications.
TI’s provision of technical, application or other design advice, quality characterization, reliability data or other services or information,
including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to
assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any
way, Designer (individually or, if Designer is acting on behalf of a company, Designer’s company) agrees to use any particular TI Resource
solely for this purpose and subject to the terms of this Notice.
TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI
products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections,
enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically
described in the published documentation for a particular TI Resource.
Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that
include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE
TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY
RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or
endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
TI RESOURCES ARE PROVIDED “AS IS” AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR
REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO
ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL
PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM,
INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF
PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL,
DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN
CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949
and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements.
Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such
products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards
and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must
ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in
life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use.
Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life
support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all
medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S.
TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product).
Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications
and that proper product selection is at Designers’ own risk. Designers are solely responsible for compliance with all legal and regulatory
requirements in connection with such selection.
Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer’s noncompliance with the terms and provisions of this Notice.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2017, Texas Instruments Incorporated
Similar pages