BTCPower BAO10 ~ 60 Series Broadband TelCom Power, Inc. TM Redefining “Current” Limits In Power Conversion 10 ~ 60W Open Frame AC-DC Power Modules • • • • • • • Universal Input 90-264 Vac PCB Mountable Efficiency to 75%. Industry Standard Pin Out 100 % full load burn-in test ISO-9001 certified manufacturer Short circuit / overload / over voltage protection • Approvals: UL / TUV / CE Specifications Input voltage range…………………………………… 90-264 Vac Input frequency………….……………………………… 47 – 63 Hz Inrush current…………………………………………… Cold start, 25A / 155Vac, 50A / 230Vac max. Output voltage….………………………………………… Refer to below table Initial Accuracy ………………………………………….. ±1.0% max. Temperature Coefficient ……………………………….. ±0.05% / ºC Ripple & Noise, 20Mhz BW ……………………………. 50mVp-p, max @ 3.3/5Vo; 1%p-p,max @ others output voltage modules Hold-up time ¹ ………………………………………….. 8-16ms typ. Short circuit protection……………...…………………… Continuous Line regulation ² .…………………………………….…. ±0.05% max. Load regulation ³ ………………………………………… ±1.0% max. Efficiency ………..…..…………………………………… Refer to below table Isolation Voltage (Input/Output) ……………………… 4242 Vac Operating temp. range ………………………………… 0 ºC – 45 ºC Storage temp. range ………………………..…………. -40 ºC – +100 ºC Cooling…………………………………………………… Free air convection Note: 1. 2. 3. Measured at Vin = 115 Vac, Full load Measured from high line to low line Measured from full load to 10% load BTCPower TM Part Number Selection Part No Output Tolerance Ripple Efficiency BAO10-UAC-3.3 3.3V, 2.5A +/ - 1 % 50 mV 65% BAO10—UAC-5 5V, 2.0A +/ - 1 % 50 mV 70% 9V, 1.11A +/ - 1 % 90 mV 72% BAO10-UAC-12 BAO10-UAC-9 12V, 0.83A +/ - 1 % 120 mV 75% BAO10-UAC-15 15V, 0.67A +/ - 1 % 150 mV 75% BAO10-UAC-24 24V, 0.417A +/ - 1 % 240 mV 78% BAO15-UAC-3.3 3.3V, 3.0 A +/ - 1 % 50 mV 70% BAO15-UAC-5 5V, 4.4 A +/ - 1 % 50 mV 70% BAO15-UAC-9 9V, 2.44A +/ - 1 % 90 mV 77% BAO15-UAC-12 12V, 1.8 A +/ - 1 % 120 mV 80% BAO15-UAC-15 15V, 1.4 A +/ - 1 % 150 mV 80% BAO15-UAC-24 24V, 0.92A +/ - 1 % 240 mV 82% BAO20-UAC-3.3 3.3V, 4.4A +/ - 1 % 50 mV 70% BAO20-UAC-5 5V, 4.4A +/ - 1 % 50 mV 73% BAO20-UAC-9 9V, 2.44A +/ - 1 % 90 mV 77% BAO20-UAC-12 12V, 1.8A +/ - 1 % 120 mV 80% BAO20-UAC-15 15V, 1.4A +/ - 1 % 150 mV 80% BAO20-UAC-24 24V, 0.92A +/ - 1 % 240 mV 82% BAO40-UAC-3.3 3.3V, 6 A +/ - 1 % 50 mV 74% BAO40- UAC-5 5V, 6 A +/ - 1 % 50 mV 78% 9V, 4.45A +/ - 1 % 90 mV 82% BAO40- UAC-12 BAO40- UAC-9 12V, 3.34A +/ - 1 % 120 mV 84% BAO40- UAC-15 15V, 2.67A +/ - 1 % 150 mV 85% +/ - 1 % 240 mV 86% BAO40- UAC-24 24V, 1.67A BAO40- UAC-30 30V, 1.33A +/ - 1 % 300 mV 86% BAO40- UAC-36 36V, 1.11A +/ - 1 % 360 mV 87% BAO40- UAC-48 48V, 0.834A +/ - 1 % 480 mV 88% BAO60- UAC-3.3 3.3V, 8 A +/ - 1 % 50 mV 74% BAO60- UAC-5 5V, 8 A +/ - 1 % 50 mV 78% BAO60- UAC-9 9V, 6.67A +/ - 1 % 90 mV 82% BAO60- UAC-12 12V, 5 A +/ - 1 % 120 mV 84% BAO60- UAC-15 15V, 4 A +/ - 1 % 150 mV 85% BAO60- UAC-24 24V, 2.5 A +/ - 1 % 240 mV 86% BAO60- UAC-30 30V, 2 A +/ - 1 % 300 mV 86% BAO60- UAC-36 36V, 1.67A +/ - 1 % 360 mV 87% +/ - 1 % 480 mV 88% BAO60- UAC-48 48V, 1.25A Note: BAO40 and BAO60 series , the output voltage can be 0.1V interval. Broadband TelCom Power, Inc. – 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. Pg. 2. Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: [email protected] AC/DC BAO10-60 PB Ver1 8-7-03