Delta IEC61000-4-12 Panel mount power supply 5v 35w 1phase Datasheet

Panel Mount Power Supply 5V 35W 1Phase
Features
RoHS compliant
2 years warranty
Universal AC input
Overload protection
Efficiency> 79% Typ.
Over voltage protection
Expected life time: 10 years
Over temperature protection
Ease of wire connection to Terminals
Full aluminum casing for lightweight
and corrosion resistant handling
Model No. PMC 5V 35W 1AA
Weight:
0.18kg
Size:
98 mm X 97 mm X 38 mm (H x W x D)
Description
The new Panel Mount Power Supply is the latest offering from one of the world’s largest power supply
manufacturers and solution providers - Delta. The product range offers a nominal output voltage of 5V, a
wide temperature range from -10°C to +70°C and a highly dependable minimum holdup time. The state-ofthe-art design is made to withstand harsh industrial environments. What makes the product stands out from
the crowd is its lightweight full aluminum body design which can withstand shock and vibration according to
IEC60068-2. Delta’s Panel Mount Power Supply also offers overvoltage and overload protection. Using a
wide input voltage range design, it is compatible worldwide. The input also includes DC operating voltage
from 120-375Vdc. Best of all, this excellent design and quality does not come with a big price tag.
INPUT SPECIFICATION
Input Voltage (Nominal)
Input Voltage range
Input Frequency (Nominal)
Input Frequency range
DC Input Voltage (Nominal)
DC Input Voltage Range
Input Current
Efficiency
Inrush current (Cold Start)
Leakage Current
100 - 240Vac
85 - 264Vac
50 - 60Hz
47 - 63Hz
125 - 250Vdc
120 - 375Vdc
< 0.9A @ 115Vac, < 0.8A @ 230Vac
> 79% @ 115Vac & 230Vac
< 30A @ 115Vac, < 60A @ 230Vac
< 1mA @ 240Vac
OUTPUT SPECIFICATION
Output Voltage (Nominal)
Output Voltage Tolerance
Output Voltage Adjust Range
Line Regulation
Load Regulation
Residual Ripple (PARD), 20MHz BW
Output Current (Nominal)
Power Derating above 50°C
Rise Time
Start-Up Time
Hold-Up Time
Dynamic Response (Overshoot &
Undershoot O/P Voltage)
Startup with capacitive loads
www.DeltaPSU.com
5 Vdc
+/- 2% (Initial set point tolerance)
4.75 – 5.5 Vdc
< 0.5% Typical @ 85 to 264Vac input, 100% load
< 1% Typical @ 85 to 264Vac input, 0 to 100% load
< 70mVpp (25°C)
7.0 A
Derated Linearly 2.5% / °C
< 30 ms @ nominal input, 100% load (25°C)
< 2500 ms @ nominal input, 100% load (25°C)
> 15ms @ 115Vac, > 80ms @ 230Vac (100% load, 25°C)
+/-5% @ 0% - 100% load
6,600µF @ nominal input & nominal O/P voltage 5V (25°C)
1
Panel Mount Power Supply 5V 35W 1Phase
Device Description
Description (Fig.1)
1) Input & Output terminal block connector
2) DC Voltage adjustment potentiometer
3) DC OK control LED (green)
Mechanical Drawing
MECHANICAL SPECIFICATION
Dimension
Weight
Cooling System
Input & Output Terminal
Output Indicator
Casing
www.DeltaPSU.com
98 mm X 97 mm X 38 mm (H x W x D)
0.18kg
Convection
Terminal Block with screw M3.5 x5 pins (rated 300VAC, 20A)
Green LED (DC OK)
Aluminum
2
Panel Mount Power Supply 5V 35W 1Phase
www.DeltaPSU.com
3
Panel Mount Power Supply 5V 35W 1Phase
PROTECTION
6.5V +10%/-10%, SELV output, Hicc-up Mode, Non-Latching
(Auto recovery).
> 120% of rated load current, Hicc-up Mode, Non-Latching
(Auto recovery).
< 75°C Ambient Temp@ 100% load. Non-Latching (Autorecovery).
Over Voltage Protection
Over Load, Over Current Protection
Over Temperature Protection
Hicc-up Mode, Non-Latching, (Auto-recovery when the fault is
removed).
Short Circuit Protection
Over Load Protection
Over Voltage Protection
The Power Supply is provided with an overload
The Power Supply has an overvoltage protection (OVP)
protection (OLP/OCP) function which protects the power
and is activated when the power supply feedback circuit
supply
fails. The output voltage will not be > 6.5V +/-10% under
from
possible
damage
by
over
current.
Additionally power supply also has over temperature
any Line/Load and operating ambient temperature.
protection (OTP) in case the over load condition persists
The Power Supply does not shut down but goes into
for a longer duration and is below the overload trigger
Hiccup mode (Auto-Recovery) which is 6.5V +/- 10%.
point but > 100% load. Typically the over load current
The output voltage will recover back to 5Vdc once the
(IOL) is > ISURGE (120%) output voltage will start drooping
fault is removed
down when the power supply reaches max power limit
and will run into bouncing mode when the output reaches
Short Circuit Protection
UVLO (under voltage point). The output voltage will
The Power Supply also has a short circuit protection
recover automatically when the overload condition is
which is in line with the overload protection and
removed.
activates whenever there is a short across the output
voltage, output goes in bouncing mode and remains
Over Temperature Protection
until the fault is removed.
The Power Supply has an over temperature protection
(OTP). This is activated when the overload condition
persists for an extended duration and the output current
is below the overload trigger point but >100% load.
In the event of a higher ambient operating condition at
100% load, the Power Supply will run into OTP when the
ambient temperature is > 55°C. When activated, the
output voltage will go into bouncing mode until the
operating ambient temperature drops to 50°C or output
capacity is reduced as recommended in the graph.
www.DeltaPSU.com
4
Panel Mount Power Supply 5V 35W 1Phase
Derating Curve
Note
1.
Do not use the power supply in areas outside the shaded portion as shown in the above graph, internal
parts may occasionally deteriorate or be damaged.
2. For the power derating refer above graph ambient temperature > 50°C, the output capacity has
to be reduced by 2.5% per Kelvin increase in temperature. If the output capacity is not reduced
when Amb > 50°C device will run into thermal protection by switching off i.e. device will go in
bouncing mode and will recover when Amb is lowered or load is reduced as far as necessary to
keep device in working condition.
3. If the power supply has to be mounted in any other direction please contact your service
provider.
4. In order for the device to function in the manner intended, it is also necessary to observe lateral
spacing of 20 mm to other modules.
5. Depending on the ambient temperature and load of the device, the temperature of the housing
can become very high!
www.DeltaPSU.com
5
Panel Mount Power Supply 5V 35W 1Phase
Over Load Protection
* Typically the over load current (IOL) is > ISURGE (120%) output voltage will start drooping down when the power supply reaches max
power limit and will run into bouncing mode when the output reaches UVLO (under voltage point). The output voltage will recover
automatically when the overload condition is removed.
Over Voltage Protection
The Power Supply does not shut down but goes into Hiccup mode (Auto-Recovery) which is 6.5V +/- 10%. The output voltage will
recover back to 5Vdc once the fault is removed
www.DeltaPSU.com
6
Panel Mount Power Supply 5V 35W 1Phase
ENVIRONMENT
Ambient temperature (Operating)
Operating Humidity
Ambient temperature (Storage)
Altitude (Operating)
Shock Test
Vibration (Non-Operating)
Bump
MTBF
Expected Cap Life Time
Material and Parts
Degree of protection
Class of protection
Pollution degree
-10°C to +50°C, with operation to 70°C possible with a linear
derating to half power from 50°C to 70°C.
< 95%RH
-25°C to 85°C
3,000 Meters
IEC60068-2-27, 30G (300m/s2)
IEC60068-2-6, 10Hz to 150Hz @ 50m/s2 (5G peak) for all X,
Y, Z direction
IEC60068-2-29, 11ms/ 10gn
> 700,000 hrs, as per BELL CORE STD or IEC61709
Tested at 115Vac & 230Vac input, 100% load, 25°C ambient
10 years (115Vac & 230Vac, 50% load and 40°C ambient).
RoHS directive, WEEE directive
IPX0
Class I with PE connection
2
Inrush Current
Output Voltage Adjust
Inrush Current is the first surge current seen on the
The 5 VDC connection is made using the "+" and "–" screw
input side when AC input is applied to the power
connections. At the time of delivery, the output voltage is 5
supply. It is the first pulse captured; see a typical
V DC. The output voltage can be set from 4.75 to 5.5 VDC
picture for the inrush current as seen in the power
on the potentiometer seen as Adjust on the front panel of
supply.
each power supply.
Start Up Time
Dynamic Load
Start up time is measured from the point AC input is
applied and the o/p voltage reaches within 90% of its
The Power Supply is capable of dynamic output
set value. See picture below for a typical start up time
voltage load change from 2% to 100% within +/-5%
characteristic of a power supply.
regulation limits. See picture below on the dynamic
behavior the Power Supply.
Rise Time
Rise time is the time needed for o/p voltage to rise
from 10% of its set value to 90% of its set value. See
the picture below for a typical rise time measurement
in a power supply.
Hold Up Time
Hold-up time is the duration which output voltage
retains regulation while AC input collapses. Picture
below is a typical hold-up time characteristic.
www.DeltaPSU.com
7
Panel Mount Power Supply 5V 35W 1Phase
Hold Up Time
* Hold-up time is the duration which output voltage retains regulation while AC input collapses
Dynamic Load
* The power supply is capable of dynamic change of load from 0% to 100% with o/p voltage within +5% of regulation limits.
www.DeltaPSU.com
8
Panel Mount Power Supply 5V 35W 1Phase
Redundancy Operation with ORing Diode
*See the figure for a typical Redundant/Parallel operation of PSU using PMC series power supplies. The 2 power supplies PSU1 &
PSU 2 are connected thru a twin diode where Anode1 A1 is connected to the +Ve i.e. 5V of PSU1 and Anode2 A2 is connected to the
+Ve i.e. 5V of PSU2 and the output ground GND are shorted together. The output of these 2 power supplies PSU1 & PSU2 is drawn
from the Cathode K of the twin diode thus making the power supply work in Redundant/Parallel operation.
www.DeltaPSU.com
9
Panel Mount Power Supply 5V 35W 1Phase
SAFETY STANDARDS /EMC
SAFETY STANDARD
EMI
FCC Title 47, Class B / EN55022, CISPR22, CLASS B
EMS
 EN 61000-4-2 1)
Electrostatic Discharge Standard
(ESD)
 EN 61000-4-3 1)
Radiate Field Immunity
 EN 61000-4-4 1)
Fast transients (Burst Immunity)
 IEC 61000-4-5 1)
Surge voltage Immunity




CCC
SIQ to EN60950-1,
UL/cUL Recognize to UL 60950-1 asd CSA C22.2 no. 60950-1
CE EMC and Low Voltage directive
CB test certificate and report to IEC60950-1
EN 61000-4-6 1)
Conducted Immunity
EN 61000-4-8 1)
Power frequency magnetic field
EN 61000-4-11 2)
Voltage dips
IEC 61000-4-12 1)
Low Energy Pulse Test (Ring Wave)
Galvanic Isolation :
Input / output
type test/routine test :
Input / PE
type test/routine test :
output / PE
type test/routine test :
LEVEL 4 Criteria A
Air Discharge
: 15 KV
Contact discharge : 8 KV
LEVEL 3 Criteria A
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation.
LEVEL 3 Criteria A
2 KV4)
LEVEL 3 Criteria A
Common Mode
: 2 KV3)
Differential Mode : 1 KV4)
LEVEL 3 Criteria A
150KHz - 80MHz / 10Vrms.
LEVEL 3 Criteria A
10A/Meter
Input 100% dip 1 cycle, Main Buffering > 20ms, Self Recoverable
LEVEL 3 Criteria A
Common Mode
: 2 KV3)
Differential Mode : 1 KV4)
3.0 KVac/
1.5 KVac/
500Vac/
1) Criterion A:
Normal operating behavior within the defined limits.
2) Criterion B:
Temporary impairment to operational behavior that is corrected by the device itself.
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
Delta RoHS Compliant
Restriction of the usage of hazardous substances
The European directive 2002/95/EC limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium,
chrome6+, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHs is the abbreviation
for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. All items in the catalog conform to this
standard.
PFC –Norm EN 61000-3-2
Line Current harmonic content
Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial
environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some
technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs, Frequently, the
user does not profit form fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a
specific application.
www.DeltaPSU.com
10
Similar pages