MORNSUN LS01-15B09S Ls01 series ----- are high efficiency green power modules with miniature packaging provided by mornsun. Datasheet

LS01 Series
1W, HIGH VOLTAGE DC-DC(AC-DC) CONVERTER
LS01 Series ----- are high efficiency green power modules with miniature
packaging provided by Mornsun. The features of this series are: wide input
voltage, DC and AC all in one, high efficiency, high reliability, low loss, safety
isolation etc, meet UL60950/EN60950 standards. All models are particularly
suitable for the applications demanding on the volume, need to meet UL/CE
standard, less demanding on EMC like industrial, electric power,
instrumentation, smart home. For harsh EMC environment, this series of
products must use the refered application circuit.
RoHS
PART NUMBER SYSTEM
LS01-15B15S
FEATURES
1. Wide input voltage:100 ~ 400VDC(85 ~ 264VAC)
2. Over current protection and short circuit protection
3. High efficiency, high density
4. Low loss, green power
5. Industrial level
6. Ultra-Miniature package
7. Meet UL/CE standard
Special Mark
Output Voltage
Output Style
In put Voltage
Isolation Voltage
Output Power
Package Style
Product Series
SELECTION GUIDE
Package
(Typ.)
Model
Power
Output (Vo/Io)
Ripple and Noise
Efficiency (%)
(Typ.)
LS01-15B05S
5V/200mA
100mV(Typ.)
150mV(Max.)
66
LS01-15B09S
9V/111mA
80mV(Typ.)
120mV(Max.)
67
12V/83.3mA
80mV(Typ.)
120mV(Max.)
70
LS01-15B15S
15V/66.6mA
80mV(Typ.)
120mV(Max.)
69
LS01-15B24S
24V/41.6mA
100mV(Typ.)
150mV(Max.)
68
LS01-15B12S
34.0*26.0*10.5mm
1W
INPUT SPECIFICATIONS
Input voltage range
100~400VDC(85~264VAC)
Input current
120mA (Max.)
Inrush current
20A
External input fuse (recommended)
1A/250V
slow blow
OUTPUT SPECIFICATIONS
LS01-15B05S
LS01-15B09S
Voltage set accuracy
-25℃~+55℃
±5%
-40℃~+85℃
±10%
-25℃~+55℃
±3%
-40℃~+85℃
±5%
LS01-15B12S
LS01-15B15S
LS01-15B24S
±1.5% (Typ.)
Input variation
±2.5% (Typ.)
Load variation (5%~100%)
Ripple & noise(p-p)
(20MHz Bandwidth)
Note :Low frequency ripple is
normal.
5 VDC output
100mV(Typ.)
150mV(Max.)
9 VDC output
80mV(Typ.)
120mV(Max.)
12VDC output
80mV(Typ.)
120mV(Max.)
15VDC output
80mV(Typ.)
120mV(Max.)
24VDC output
100mV(Typ.)
150mV(Max.)
Short circuit protection
Continuous, automatic resume
Over temperature protection
No
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LS01 series
A/0-2012
Page 1 of 4
COMMON SPECIFICATIONS
Operating
Power
derating
Temperature ranges
-40℃~+85℃
1.33%/ ℃
(55~85℃ )
2%/ ℃
(-40℃~-20℃ )
Storage
-40℃~+105℃
The Max. Case Temperature
+90℃ (Max.)
Humidity
85% (Max.)
Temperature coefficient
0.1%/ ℃
Switching frequency
Variational Frequency 50KHz (Max.)
I/O-isolation voltage
Input and Output
CE
EMI
RE
3000VAC/1Min
CISPR22/EN55022
CLASS A(External Circuit Refer to Figure 1)
CISPR22/EN55022
CLASS B(External Circuit Refer to Figure 3)
CISPR22/EN55022
CLASS A(External Circuit Refer to Figure 1)
CISPR22/EN55022
ESD
RS
perf. Criteria B
IEC/EN61000-4-3
10V/m
perf. Criteria A(External Circuit Refer to Figure 3)
IEC/EN61000-4-4
±2KV
perf. Criteria B(External Circuit Refer to Figure 1)
IEC/EN61000-4-4
±4KV
perf. Criteria B(External Circuit Refer to Figure 3)
Surge
IEC/EN61000-4-5
±2KV/±4KV
perf. Criteria B(External Circuit Refer to Figure 3)
CS
IEC/EN61000-4-6
3 Vr.m.s
perf. Criteria A(External Circuit Refer to Figure 3)
PFM
IEC/EN61000-4-8
10A/m
perf. Criteria A
Voltage dips、short and
interruptions immunity
IEC/EN61000-4-11 0%-70%
EMC
EFT
EMS
CLASS B(External Circuit Refer to Figure 3)
Contact ±4KV
IEC/EN61000-4-2
Case material
UL94V-0
Install
PCB
MTBF
>300,000h @25℃
perf. Criteria B
Note:
1.
External electrolytic capacitor are required to models when AC input, more details refer to typical applications.
2.
Ripple and Noise were measured by the method of anear measure (more details refer to the anear measure).
3.
All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4.
In this datasheet, all the test methods of indications are based on corporate standards.
ANEAR MEASURE
Connect Oscillograph Probe
Copper sheet
FUSE
L
Load
N
Note: C1: 1µF (Ceramic capacitor)
C2: 10µF (Electrolytic capacitor)
PRODUCT TYPICAL CURVE
Temperature VS Load
Input Voltage VS Load
Load(%)
Load(%)
100
100
80
80
60
60
40
40
70 100
85 110
340 400
240 264
Vdc
Vac
The copyright and authority for the interpretation of the products are reserved by MORNSUN
-40 -20
55
85
Temperature( ℃ )
Specifications subject to change without notice.
LS01 series
A/0-2012
Page 2 of 4
LS01 DC input rated load efficiency cure
80
75
70
65
60
55
50
45
40
35
30
25
10
80
75
Efficiency(%)
Efficiency(%)
LS01 DC input efficiency cure
100VDC
200VDC
300VDC
.
400VDC
LS01-15B05S
LS01-15B09S
70
LS01-15B12S
65
LS01-15B15S
LS01-15B24S
60
55
20
30
40
50
60
70
80
90
100
100
150
200 250 300 350
Input Voltage(VDC)
400
Load(%)
LS01 AC input rated load efficiency cure
80
75
70
65
60
55
50
45
40
35
30
25
80
85VAC
LS01-15B05S
75
110VAC
Efficiency(%)
Efficency (%)
LS01 AC input efficiency cure
230VAC
264VAC
LS01-15B09S
70
LS01-15B12S
LS01-15B15S
65
LS01-15B24S
60
55
10
20
30
40
50
60
70
80
90 100
85
110
Load (%)
120
220
230
Input Voltage(VAC)
240
264
STRUCTURE FIGURE
3
+Vin(L)
12
1
-Vin(N)
Rec tifier
filter
c irc u it
DC/DC
Con ve rtor
Rec tifica te
+Vo
10
-Vo
7
GND
External
C1
Capacitor
+
+CAP
5
TYPICAL APPLICATIONS
FUSE
NTC
L
C1
+
MOV
+ Vo
+Vo
AC-DC
+
5 AC-DC
7
1
N
L
L
+Vo C2 C3 T VS RL
12
3
N
N
10
-Vo
-Vo
-Vo
PE
Figure 1:LS01-15BXXS
Figure 2:Note: This application is not supported for this series.
can use MORNSUN’s FC-L0 1D
F USE
R2
L
L
CY1
MO V
CY3
CX
R3
CY2
CY4
5
AC-DC
OUT PUT
7
R1
N
C1
+
LCM
N
PE
Figure 3:LS01 series Recommended circuit for application require higher EMC standard
(external circuit output same as above)
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LS01 series
A/0-2012
Page 3 of 4
Figure 4:EMC application circuit PCB layout
Safety and recommend wiring: linewidth A≥3mm
Output Voltage
EXTERNAL CAPACITORS TYPICAL VALUE
C2
C3
C1
5V
FUSE
470µF/35V
TVS
SMBJ7.0A
9V
SMBJ12A
12V
1µF/50V
(Ceramic capacitor)
10µF-22µF /400V
1A/250V
150µF/35V
15V
24V
100µF/35V
SMBJ20A
SMBJ30A
Note:
1.
C1:AC input, is filtering electrolytic capacitor (which is required), when input voltage is below 100VAC, and the value of C1 is 10µF-22μF/400V.
DC input, is a filtering capacitor in EMC Filter, the value of C1 is 10µF/400V(when input voltage is above 370VDC, and the value of C1 is 10µF/450V), If
EMC performance is not required,C1 could not need.
2.
Output filtering capacitor C2 (which is required when AC input or DC input) is recommended to use high frequency and low impedance electrolytic capacitors.
For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C3 is ceramic
capacitor, it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (if converter fails). External input NTC is
recommended to use 5D-9.
3.
For standard EMC requirement, please refer to figure 1 , if higher EMC requirement ,please refer to figure 3.
MOV: Varistor, model: 561KD14,it is used to protect the device under surge;
R1 、R2:2Ω/3W Winding resistor;
R3:1MΩ/2W ;
CY1、CY2、CY3、CY4:1nF/400VAC;
CX:0.22µF /275VAC;
LCM:10mH-30mH;
FC-L01D:Mornsun’s 2KV/4KV Surge protector.
4.
FUSE: 1A/250V
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT
(Front View)
3
5
7
10
12
0.84[0.033]
2.54[0.100]
5.08[0.200]
0.40
[0.016]
7.62[0.300]
(Bottom View)
1
3
5
7
10
12
Φ1.30
[0.051]
Note: grid 2.54*2.54mm.
Max11.00
[0.433]
Min3.00
[0.139]
1
Max27.00[1.063]
Max24.00
[0.945]
SIP Package
PACKAGING DIAGRAM
0.65
[0.026]
Max35.00[1.378]
Note:
Unit: mm[inch]
Pin section tolerances: ± 0.10mm[±0.004inch]
General tolerances: ± 0.50mm[ ± 0.020inch]
FOOTPR INT D ETAILS
Function
Pin
1
-Vin (N )
+Vin (L)
3
5
+CAP
7
GND
10
12
Inner box dimensions: L*W*H=355*192*93mm
Packaging quantity: 100pcs
Outer box dimensions: L*W*H=405*380*305mm
Packaging quantity: 600pcs
-Vo
+Vo
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-28203030
Fax:86-20-38601272
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LS01 series
A/0-2012
Page 4 of 4
Similar pages