Vishay DFL1501S Low profile miniature glass passivated single-phase surface mount bridge rectifier Datasheet

New Product
DFL15005S thru DFL1514S
Vishay General Semiconductor
Low Profile Miniature Glass Passivated Single-Phase
Surface Mount Bridge Rectifiers
FEATURES
• Low profile: typical height of 2.5 mm
• UL recognition, file number E54214
~
• Ideal for automated placement
~
• High surge current capability
• Meets MSL level 1, per J-STD-020, LF maximum
peak of 250 °C
~
• Solder dip 260 °C, 40 s
~
• Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
Case Style Low Profile DFS
TYPICAL APPLICATIONS
General purpose use in ac-to-dc bridge full wave
rectification for SMPS, lighting ballaster, adapter,
battery charger, home appliances, office equipment,
and telecommunication applications.
PRIMARY CHARACTERISTICS
IF(AV)
1.5 A
VRRM
50 V to 1400 V
IFSM
50 A
IR
5 µA
VF
1.1 V
TJ max.
150 °C
MECHANICAL DATA
Case: Low profile DFS
Epoxy meets UL 94V-0 flammability rating
Terminals: Matte tin plated leads, solderable per
J-STD-002 and JESD22-B102
E3 suffix for consumer grade, meets JESD 201 class
1A whisker test
Polarity: As marked on body
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
SYMBOL
DFL
15005S
DFL
1501S
DFL
1502S
DFL
1504S
DFL
1506S
DFL
1508S
DFL
1510S
DFL
1514S
UNIT
Maximum repetitive peak
reverse voltage
VRRM
50
100
200
400
600
800
1000
1400
V
Maximum RMS voltage
PARAMETER
VRMS
35
70
140
280
420
560
700
980
V
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
1000
1400
V
Maximum average forward output
rectified current at TA = 40 °C (1)
IF(AV)
1.5
A
Peak forward surge current single
half sine-wave superimposed on
rated load
IFSM
50
A
I2t
10
A 2s
TJ, TSTG
- 55 to + 150
°C
Rating for fusing (t < 8.3 ms)
Operating junction and storage
temperature range
Note:
(1) Units mounted on P.C.B. with 0.51 x 0.51" (13 x 13 mm) copper pads
Document Number: 88874
Revision: 31-Jan-08
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
1
New Product
DFL15005S thru DFL1514S
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
DFL
TEST
SYMBOL
15005S
CONDITIONS
PARAMETER
DFL
1501S
DFL
1502S
DFL
1504S
DFL
1506S
DFL
1508S
DFL
1510S
DFL
1514S
UNIT
Max. instantaneous forward
voltage drop per diode
1.5 A
VF
1.1
V
Maximum DC reverse
current at rated DC blocking
voltage per diode
TA = 25 °C
TA = 125 °C
IR
5.0
500
µA
CJ
16
pF
Typical junction
capacitance per diode (1)
Note:
(1) Measured at 1.0 MHz and applied reverse voltage of 4.0 V
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
DFL
15005S
DFL
1501S
DFL
1502S
DFL
1504S
RθJA
RθJL
Typical thermal resistance (1)
DFL
1506S
DFL
1508S
DFL
1510S
DFL
1514S
40
15
UNIT
°C/W
Note:
(1) Units mounted on P.C.B. with 0.51 x 0.51" (13 x 13 mm) copper pads
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
DFL1506S-E3/45
0.341
45
50
Tube
DFL1506S-E3/77
0.341
77
1500
13" diameter paper tape and reel
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
60
50 Hz
Resistive or
Inductive Load
Peak Forward Surge Current (A)
Average Forward Current (A)
2.0
1.5
1.0
0.5
TJ = 150 °C
Single Sine-Wave
50
40
30
20
10
0
0
20
40
60
80
100
120
140
160
1
100
10
Ambient Temperature (°C)
Number of Cycles at 50 Hz
Figure 1. Forward Current Derating Curve Per Diode
Figure 2. Maximum Non-Repetitive Peak Forward Surge
Current Per Diode
www.vishay.com
2
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
Document Number: 88874
Revision: 31-Jan-08
New Product
DFL15005S thru DFL1514S
Vishay General Semiconductor
100
TJ = 150 °C
1
Junction Capacitance (pF)
Instantaneous Forward Current (A)
10
TJ = 125 °C
TJ = 25 °C
0.1
TJ = 25 °C
Pulse Width = 300 µs
1 % Duty Cycle
0.01
0.4
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
10
1
0.5
0.6
0.7
0.9
0.8
1.1
1.0
1.3
1.2
10
1
1.4
100
Instantaneous Forward Voltage (V)
Reverse Voltage (V)
Figure 3. Typical Forward Voltage Characteristics Per Diode
Figure 5. Typical Junction Capacitance Per Diode
Instantaneous Reverse Leakage
Current (µA)
1000
TJ = 150 °C
100
TJ = 125 °C
10
1
TJ = 25 °C
0.1
0.01
10
20
30
40
50
60
70
80
90
100
Percent of Rated Peak Reverse Voltage (%)
Figure 4. Typical Reverse Characteristics Per Diode
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
Case Style Low Profile DFS
0.205 (5.2)
0.195 (5.0)
0.047 (1.20)
0.040 (1.02)
Mounting Pad Layout
0.047 Min.
(1.20 Min.)
0.404 Max.
(10.26 Max.)
0.060 Min.
(1.52 Min.)
0.335 (8.51)
0.320 (8.13)
45o
0.013 (0.330)
0.009 (0.241)
0.404 (10.3)
0.386 (9.80)
0.255 (6.5 )
0.245 (6.2 )
0.205 (5.2)
0.195 (5.0)
0.102 (2.60)
0.094 (2.40)
0.060 (1.524)
0.040 (1.016) 0.013 (0.330)
0.003 (0.076)
Document Number: 88874
Revision: 31-Jan-08
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
3
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08
www.vishay.com
1
Similar pages