DYELEC FR607 .0 amp.fast recovery rectifier Datasheet

FR601 THRU FR607
6 .0 AMP.Fast Recovery Rectifiers
Features
· Low forward voltage drop
R-6
· High current capability
· High reliability
· High surge current capability
· Plastic material-UL flammability 94V-0
MIN.
Mechanical Data
DIA.
· Case: Molded plastic R-6
· Terminals: Plated leads solderable per
MIL-STD-202,Method 208 guaranteed
· Polarity: Color band dentes cathode end
DIA.
· Mounting Position: Any
MIN.
· Making: Type Number
· Lead Free: For RoHS/Lead Free Version
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified
Single phase,half wave,60Hz,resistive or inductive load
For capacitive load derate current by 20%
Type Number
SYMBOL FR601 FR602 FR603 FR604 FR605 FR606 FR607 Unit
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
V
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
V
Maximum Average Forward Rectified
Current.375"(9.5mm) lead length@TA=75℃
IO
6.0
A
Peak Forward Surge Current 8.3ms Single half
sine-wave superimposed on rated load
(JEDEC Method)
IFSM
250
A
Forward Voltage
VFM
1.3
V
@IF=6.0A
Peak Reverse Current
@TA=25℃
At Rated DC Blocking Voltage @TA=100℃
5.0
IR
uA
100
Typical Junction Capacitance (Note 1)
CJ
Typical Thermal Resistance Junction to
Ambient(Note 2)
RθJA
Maximum Reverse Recovery Time(Note 3)
Trr
Operating Temperature Range
TJ
-55 to +125
℃
TSTG
-55 to +150
℃
Storage Temperature Range
140
70
pF
℃ /W
32
150
250
500
Note: 1. Measured at 1.0 MHz and Applied reverse Voltage of 4.0V D.C
2. Leads maintained at ambient temperature at a distance of 9.5mm from the case
3.Reverse Recovery Test Conditions: IF=0.5A, IR=1A, Irr=0.25A
version:01
1of2
www.dyelec.com
ns
FR601 THRU FR607
FIG.2-TYPICAL FORWARD CHARACTERISTICS
1000
6.0
5.0
4.0
3.0
2.0
SINGLE PHASE HALF WAVE 60Hz
RESISTIVE OR INDUCTIVE LOAD
1.0
0
20
40
60
80
100
120
140
AMBIENT TEMPERATURE (℃)
INSTANTANEOUS FORWARD CURRENT,(A)
AVERAGE FORWARD CURRENT ( A )
FIG. 1 – FORWARD CURRENT DERATING CURVE
100
10
T A = 25°C
1.0
PULSE WIDTH 300us
0.1
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
INSTANTANEOUS FORWARD VOLTAGE (V)
FIG.4 – TYPICAL JUNCTION CAPACITANCE
1000
400
300
CAPACITANCE, (pF)
PEAK FORWARD SURGE CURRENT,( A )
FIG. 3 – MAXIMUM NON-REPETITIVE SURGE CURRENT
200
100
PULSE WIDTH 8.3ms
SINGLE HALF-SINE-WAVE
(JEDEC METHOD)
FR601 - FR604
100
FR605 - FR607
0
1
2
5
10
20
50
100
T J = 25°C f = 1 MHz
NUMBER OF CYCLES AT 60Hz
10
1
4
10
REVERSE VOLTAGE (V)
version:01
2of2
www.dyelec.com