DB Lectro JMX-94FBS80DC12V Magnet latching relay small size, light weight Datasheet

J M X- 9 4 F
CH0054070—2000
39×30×17.5
Features
Magnet latching relay.
Small size, light weight.
High sensitivity & reliability.
Well anti-shock and anti-vibration.
Heavy contact load.
Ordering Information
JMX-94F A Z 60 DC12V
1
2
3
4
5
1 Part number:JMX-94F
2 Contact arrangement:A:1A;B:1B
3 Enclosure:S: Sealed type;Z: Dust cover
4 Contact Current:40:40A;60:60A;80:80A
5 Coil rated Voltage(V):DC: 9,12, 24
Contact Data
1ASPSTNO
1BSPSTNC
AgCd O
80A/250VAC
60A/250VAC
40A/250VAC
20000VA
15000VA
10000VA
300VAC
Max. Switching Current:80A
አ50m (at 1A/24VDC)
Item 3.12 of IEC255-7
100mV (at rated load)
Item 3.12 of IEC255-7
Contact Arrangement
Contact Material
Contact Rating(resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance & Voltage drop
Operation life
Electrical
(Rated load)
Mechanical
(No load)
104
Item 3.30 of IEC255-7
106
Item 3.31 of IEC255-7
Coil Parameter
DASH
NUMBERS
COIL
RATED
VOLTAGE
VDC
COIL
RESISTANCE
±10%
SWITCHING
VOLTAGE
VDC
(50%-70% of
rated voltage)
009-1000
9
81
4.5~6.3
012-1000
12
144
6.0~8.4
024-1000
24
576
12.0~16.8
PULSE
MAGNITUDE
ms
COIL
POWER
consumption
W
Operate
Time
ms
Reset
Time
ms
60
1
20
20
CAUTION: 1.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously.
coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three
times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to
be in the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.
151
www.dblectro.com
JMX-94F
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Creepage distance
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1500V
50Hz 4000V
8.4mm
Functional 100m/s2;Survival:1000 m/s2 11ms
10~55Hz Double amplitude 1.5mm
5N
2352 30.5s
-25~70
85% (at 40)
33g
Item 6 of IEC255-5
Item 6 of IEC255-5
Addenda B of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval
Load
CCEE
80A/220VAC
11
3,5
17,5
Dimensions (Unit: mm)
(assistant mounting terminal)
14
5,08
25.4
3-1X0.4
(3-0.6X0.6)
5,5
28
3-Φ1.2
2,5
39
2.5
2.8
11
(10)
0.6
(1.0)
30
25,6
5,08
0.6
(1.0)
Mounting (Bottom views)
9
8,5
12
20
Dimensions
+
NOTES 1).Dimensions are in millimeter.
Wiring diagram
2).Inch equivalents are given for general information only.
3).Relays shall have plus(+) signs placed on the circuit diagram as shown.
mm
0.4
0.6
1.0
1.2
2.5
2.8
3.5
5.08
5.5
8.5
9
10
11
12
14
17.5
20
25.4
25.6
28
30
39
inch
0.016
0.024
0.039
0.047
0.098
0.110
0.138
0.200
0.217
0.335
0.354
0.394
0.433
0.472
0.551
0.689
0.787
1.000
1.008
1.102
1.181
1.535
Reference Data
www.dblectro.com
Similar pages