Schurter EF12 Iec appliance inlet c20 with filter, circuit breaker ta45 Datasheet

EF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
C20
Approvals and Compliances
70° C
Description
- Panel Mount :
Screw-on mounting from front side
- 3 Functions :
Appliance Inlet Protection class I , circuit breaker type TA45 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
-
All single elements are already wired
Circuit Breaker non-illuminated or illuminated
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version without line filter EF11
Alternative: Standard version
Weblinks
pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temperature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material: Housing
12 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz
12 - 20 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
Circuit Breakers
Line Filter
MTBF
C20 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 100'000 h acc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: EF12
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40001520
UL Approvals
UL
UL File Number: E72928
EMC Products
1
EF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Designed according to
IEC 61058-1
Switches for appliances. Part 1. General requirements
Designed according to
UL 498
Standard for Attachment Plugs and Receptacles
Designed according to
UL 1283
Electromagnetic interference filters
Designed according to
CSA C22.2 no. 42
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Designed according to
CSA C22.2 no. 8
Electromagnetic interference (EMI) filters
Design
Standard
Description
Designed for applications acc.
IEC/UL 60950
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Designed for applications acc.
IEC 60601-1
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Medical Equipment
SCHURTER AG
Suitable for use in medical equipment according to IEC/UL 60601-1
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
2
EMC Products
EF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Dimension [mm]
37
2.8
76.2
10.6
32.2
41.2
32.9
ø3.6/M3
81±0.10
90 ±0.10
80.05
.5
R6
9.5
ø3.3
59.5
5.3
33.9 ±0.10
4.55 ±0.05
4.
7
R
05
3.
5.5
R
10.9
R 2.8
12.6
12.2
40.55
79.2
90
101
R
3.
55
±0
.0
5
0.8
ø6.4
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
12
Standard Version
2 x 0.8
100
2.2
1
16
Standard Version
2 x 0.6
100
2.2
1
20
Standard Version
2 x 0.3
100
2.2
1
12
Medical Version (M5)
2 x 0.8
100
-
1
16
Medical Version (M5)
2 x 0.6
100
-
1
20
Medical Version (M5)
2 x 0.3
100
-
1
Diagrams
Medical version (M5)
L’
L
P1
PE
N
1) Line
2) Load
Cx
Cy
R
L2
Cy
TA 45
L1
1)
PE’
N’
P2
L’
L
2)
P1
L1
1)
PE
Cx
PE’
R
L2
N
N’
2)
TA 45
Standard version
P2
1) Line
2) Load
EMC Products
3
EF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Attenuation Loss
- - - - 50Ω differential mode _____ 50Ω common mode
Standard version
12 A
16 A
20 A
16 A
20 A
Medical version (M5)
12 A
4
EMC Products
EF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Table 1 Selection for type TA45
Order example
3
P1
ABT
W
F
150
C0
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other variants on request
5
a
Diagram
Thermal overload protection
1-pole
P2
Without illumination
P2
P1
3
4
3
6
With illumination
220…240 V
110…120 V
2-pole
P1
ABT
ABD
A12
A14
A32
A34
}
Colours
Switch front
W
B
6
Rocker
black
black
black
white
black
–
–
–
orange transp.
Rocker legend
printed
OFF OFF
L
printed
Illustration
Colour of print
O
K
Surface
l
O
printed
Colour of print
black
white
P
printed
I
O
white
black
R
printed
I
M
printed
O
black
white
O
l
H
F
l
embossed
ON
Illustration
ON
Surface
Position of the rocker legend
e.g F
Rated current circuit breaker of equipment
In
Code
In
Code
In
Code
In
Code
10,0
11,0
12,0
100
110
120
13,0
14,0
15,0
130
140
150
16,0
17,0
18,0
160
170
180
19,0
20,0
190
200
Other rated currents on request
Without release: code C0
Undervoltage release
P2
P1
U<
P2
Remote trip release
b
U<
P1
P2
ba
P1
P2
c P1
U<
U
E
Z
A
Code
Rated
voltage Un
•
•
•
•
2
240 V AC
•
•
•
•
3
230 V AC
•
•
•
•
4
120 V AC
EMC Products
5
EF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
[ min ] [ sec ]
10'000
60
Tripping characteristics
In > 3… < 18 A
Type
TA45
Rated current
In <3 A
[ min ] [ sec ]
10'000
60
1 pole protected
2`000
30
20
30
2 pole protected
20
1`000
10
+23 °C
Ambient temp.
500
Tripping characteristics
In > 18 A
[ min ] [ sec ]
10'000
Type
TA4 5
Rated current
In > 3 A... < 18 A
60
1 pole protected
2`000
30
2 pole protected
20
1`000
10
+23 °C
Ambient temp.
500
10
5
5
1
1 pole protected
2 pole protected
1`000
50
50
10
10
5
5
5
2
2
2
1
1
1
0,5
0,5
0,5
0,1
1,05 1,32
2
3
4
5
8
0,3
0,2
0,1
1,05 1,32
10
[ x In ]
Multiple of rated current
Tripping time
20
10
0,2
2
3
4
5
The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature,
use a correction factor from the table on the right side:
Correction factor
0,89
0,91
0,92
1,00
1,03
1,08
1,16
8
0,3
0,2
0,1
10
1,05 1,32
[ x In ]
Multiple of rated current
1) Effect of ambient temperature
* Ambient temperature [°C]
–10
–5
0
+23
+30
+40
+55
EF12 - ABTWF150C0 - 000 - 1111 - 00 - 00
see table 1
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+40 °C ambient temperature
Interlocking
0 without V-Lock
1 with V-Lock
Terminal L and N
1 QC 6.3x0.8, without connection to TA45
3 Connection to TA45 non insulated
Type of mains filter / capacitor / bleed resistor
1 standard
X2,Y2
with bleed resistor
2 medical M5
X2
with bleed resistor
Rated current
1
20 A
2
16 A
3
12 A
6
EMC Products
4
5
8
10
[ x In ]
1) Example
Terminal PE
1 QC 6.3x0.8
1) The rated current of the line-filter must be equal
or more than the rated current of TA45.
3
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
Color
0 black
Order code TA45
(2-pole rocker-switch
without accessories)
2
Multiple of rated current
Configuration code (example)
Type
+23 °C
100
1
20
0,3
Ambient temp.
500
20
Tripping time
Tripping time
50
In >18 A
2`000
200
100
100
1
TA4 5
Rated current
5
200
200
Type
1)
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
EF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Packaging unit
16 Pcs
Accessories
Description
Cord retaining kits
Cord retaining strain relief
Flat head, H
4700.0008
Mating Outlets/Connectors
Category / Description
Connector Overview complete
IEC Connector C19, Rewireable, Straight
4795
IEC Connector C19, Rewireable, Angled
4790
IEC Connector C19, Rewireable, Straight
0104U
Connector further types to EF12
Mating Outlets/Connectors shuttered
Power Cord Overview complete
Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight
VAC19KS
02.12.2017
Power Cord further types to EF12
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
EMC Products
7
Similar pages