FNP300 AC-DC Power Supply Data Sheet 12V, 24V, 48V Output, 300 Watts Features • RoHS lead free solder and lead solder exempted products are available • Wide input voltage range 85-264 VAC • Two outputs (one high current output) • Low conducted and radiated EMI (EN 55022 class B) • UL recognized to UL 60950/CSA 22.2 No. 60950-00, and TUV approved to EN 60950-1 • High density design 4” x 1.65” x 8.5” cassette • Highly-efficient topology • I2C interface • Overtemperature, output overvoltage and output overcurrent protection • Supervisory signaling • Included ORing diode for true redundant operation Applications • Telecommunications equipment Description The FNP300 Series provides highly-efficient ac-dc power supplies, each with one high current output and an additional standby output, which can be used in a wide range of applications. Passive current share along with internal ORing diodes allow the FNP300's to be also used in redundant, hot-swap applications. All models meet international safety standards and display the CE Mark for the low Voltage Directive. Model Selection Model Input Voltage VAC Output 1 Vo nom VDC Output 2 Io max ADC Vo nom VDC Io max ADC Rated Power W FNP300-1012 85-264 12 25 12 0.7 310 FNP300-1024 85-264 24 12.5 12 0.7 310 FNP300-1048 85-264 48 6.25 12 0.7 310 Ordering Information Options Suffixes to Add to Part Number RoHS lead solder exemption No RoHS character required. RoHS compliant for all 6 substances Add "G" as the last character of the part number. MAY 30, 2006 revised to SEP 27, 2006 Page 1 of 6 www.power-one.com FNP300 AC-DC Power Supply Data Sheet 12V, 24V, 48V Output, 300 Watts Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect longterm reliability, and cause permanent damage to the converter. Parameter Input Voltage Conditions/Description Continuous Transient, 60 ms Min Max 264 300 Operating Temperature Ambient Vi min-Vi max, Io nom, cooling by internal fan Non-operational 0 55 Units VAC VAC °C -40 85 °C Storage Temperature Environmental, Mechanical, & Reliability Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Operating Humidity Storage Humidity Shock Sinusoidal Vibration MTBF Conditions/Description Relative humidity, non-condensing Relative humidity, non-condensing IEC/EN 60068-2-27, 11 ms IEC/EN 60068-2-6 2-8 Hz 8-200 Hz 200-500 Hz MIL-HDBK-217F Notice 2, GB, 25 °C Min 10 5 Nom Max 90 95 30 7.5 2 4 Units % % gn mil gn gn kh 200 Isolation Specifications The electric strength test is performed in the factory as routine test in accordance with EN 550116, IEC/EN 60950, and UL 1950 and should not be repeated in the field. Power-One will not honor any warranty claims resulting from electric strength field tests. Parameter Insulation Safety Rating Electric Strength Test Voltage Conditions/Description Input/Case Input/Output Output/Case Input/Case Input/Output Output/Case Min 2.121 3.6 0.05 Nom Max Basic Reinforced Functional Units kVDC kVDC kVDC EMC Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Electrostatic Discharge Electromagnetic Field Eletr. Fast Transients / Burst Surge Voltage Dips and Interruptions RF Conducted Immunity Description IEC/EN 61000-4-2, level 4 (contact/air) IEC/EN 61000-4-3, level 3 IEC/EN 61000-4-4, level 4 (direct/capacitive) IEC/EN 61000-4-5, level 3 (L/L, L/C) IEC/EN 61000-4-11 IEC/EN 61000-4-6 Emissions Radiated/Conducted Harmonics Voltage Fluctuation and Flicker CISPR 22/EN 55022/EN 61204 IEC/EN 61000-3-2 IEC/EN 61000-3-3 MAY 30, 2006 revised to SEP 27, 2006 Page 2 of 6 Criterion 8/15 kV, criterion B 10 V/m, criterion A 2/1 kV, criterion B 1/2 kV, criterion B Criterion B 10 VAC, AM 80%, 1 kHz, criterion A Class B Class B Pass www.power-one.com FNP300 AC-DC Power Supply Data Sheet 12V, 24V, 48V Output, 300 Watts Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Input Voltage Turn-On Input Voltage Turn-Off Input Voltage Input Frequency Inrush Current Limitation Power Factor Efficiency Conditions/Description Ramping up Ramping down 115/230 VAC Vi nom, Io nom Vi = 230 VAC, Io nom FNP300-1012 FNP300-1024 FNP300-1048 Min 85 70 70 47 Nom 115/230 50/60 Max 264 85 85 63 15/20 0.96 83 86 88 Units VAC VAC VAC Hz A % Output Specifications All specifications apply over specified input voltage, output load, and temperature range unless otherwise noted. Parameter Output Voltage Setpoint Accuracy FNP300-1012 Output Voltage Setpoint Accuracy FNP300-1024 Output Voltage Setpoint Accuracy FNP300-1048 Output Current V1 Output Current V2 Max 0.5. Units % Vo nom -0.5 0.5. % Vo nom Vi = 230 VAC, Io1 @ 12.5 ADC, TC = 25 °C -0.5 0.5. % Vo nom FNP300-1012 FNP300-1012 0 0 25 0.7 Output Current V1 Output Current V2 FNP300-1024 FNP300-1024 0 0 12.5 0.7 Output Current V1 Output Current V2 FNP300-1048 FNP300-1048 0 0 6.25 0.7 Static Line Regulation V1 Static Load Regulation V1 (Droop Characteristic) Hold-Up Time Dynamic Load Regulation Vi min-Vi max, Vi nom, 5-100% Io nom Vi min-Vi max, Vi nom, 5-100% Io nom -0.5 -5 Starting at Vi = 230 VAC, Po nom 20 Start-Up Time Output Voltage Ripple and Noise MAY 30, 2006 revised to SEP 27, 2006 Conditions/Description Vi = 230 VAC, Io1 @ 12.5 ADC, TC = 25 °C Min -0.5 Vi = 230 VAC, Io1 @ 3.125 ADC, TC = 25 °C Load change = ±33%, dIo/dt = 2A/μs voltage deviation recovery time Vi nom, Io nom Vi nom, Io nom, 20 MHz bandwidth Page 3 of 6 -2 Nom ADC ADC ADC 12.75 0.7 ADC ADC 6.4 0.7 ADC 0.5 % Vo nom 5 % Vo nom 25 0.7 ms 2 400 1 120 % Vo nom μs s mVpp www.power-one.com FNP300 AC-DC Power Supply Data Sheet 12V, 24V, 48V Output, 300 Watts Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Input Fuse Input Transient Protection Output Conditions/Description Not user accessible With varistor No-load and short circuit proof short circuit proof overload (latch style) Overvoltage Protection Latch style FNP300-1012 Latch style FNP300-1024 Latch style FNP300-1048 Automatic power shutdown at TC = 95 °C Overtemperature Protection Min 110 115 115 115 Nom Max 6.3AT Units 130 % Io nom % Io nom % Io nom 130 130 122 % Vo nom % Vo no % Vo no Control All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter I2C Digital Bus PS Seated Signal PS Remote Shutdown AC fail pre-warning (I2C & OC)* DC fail (I2C & OC)* Temperature Warning (I2C & OC)* Fan OK (I2C & OC)* Current Share Status Indication Conditions/Description Reports information and monitors alarm functions Contact closure to GND TTL compatible signal, inhibited at High or TTL “1” Supervisory AC input voltage; Pre-warning time >6 ms Supervisory under- and overvoltage pre-ORing diode of V1 Indicates if unit is operating normally or in overtemperature, Pre-warning time >10 ms Indicates if fan is operating or has failed Droop load characteristic for V1 and V2 LEDs: DC OK (green), AC OK (green) * Signal provided by I2C interface or by open collector (OC) Features All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Fan speed control µC supply voltage in-/output (Pin 10) MAY 30, 2006 revised to SEP 27, 2006 Conditions/Description 4 fan speed levels depending on inlet temperature Fan speed level and temperature information available on I2C digital bus If unit is operating: 5 to 7V is provided at pin 10. If unit is NOT operating, pin 10 is input from a parallel connected unit for µC supply. Page 4 of 6 www.power-one.com FNP300 AC-DC Power Supply Data Sheet 12V, 24V, 48V Output, 300 Watts Characteristic Curves: Figure 1. Efficiency vs. Output Load Figure 2. Efficiency vs. Input Voltage and Ambient Temperature, Io = Io nom MAY 30, 2006 revised to SEP 27, 2006 Page 5 of 6 www.power-one.com FNP300 AC-DC Power Supply Data Sheet 12V, 24V, 48V Output, 300 Watts Mechanical Data Mechanical Data (H, W, D) 4” (101.6mm) x 1.65” (41.9mm) x 8.5” (215.9mm) Weight: 2.205 lb (1 kg) Output Connector Descriptions AI RF LO W PIN 13 PIN 1 Rear View Connector: Molex (15-06-0241) Output Connector Description 12V Output 24V Output 48V Output 12V Output RTN 24V Output RTN 48V Output RTN AC-fail, DC-fail, Temp.-fail Power Supply Present Signal Serial Data Line Serial Clock Line Address Input Line A0 Address Input Line A1 5 to 7V FAN OK PS Remote Shut Down 12V Standby RTN 12V Standby Address Input Line A2 Pin Location 4,5,6,16,17,18 4,5,6,16,17,18 4,5,6,16,17,18 1,2,3,13,14,15 1,2,3,13,14,15 1,2,3,13,14,15 9 23 Reference Name Vo1 Vo1 Vo1 Vo1 RTN Vo1 RTN Vo1 RTN PS_FAIL PS_PRSNT_L 11 12 21 20 10 24 22 7 SDA SCL AO A1 µC supply voltage bus FAN_FAIL PS_RSD_H Vo2 RTN / Logic Ground / 5 to 7V RTN Vo2 A2 19 8 NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MAY 30, 2006 revised to SEP 27, 2006 Page 6 of 6 www.power-one.com