Power-One FNP300-1024 Ac-dc power supply 12v, 24v, 48v output, 300 watt Datasheet

FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Features
• RoHS lead free solder and lead solder exempted
products are available
• Wide input voltage range 85-264 VAC
• Two outputs (one high current output)
• Low conducted and radiated EMI
(EN 55022 class B)
• UL recognized to UL 60950/CSA 22.2 No. 60950-00,
and TUV approved to EN 60950-1
• High density design
4” x 1.65” x 8.5” cassette
• Highly-efficient topology
• I2C interface
• Overtemperature, output overvoltage and output
overcurrent protection
• Supervisory signaling
• Included ORing diode for true redundant operation
Applications
• Telecommunications equipment
Description
The FNP300 Series provides highly-efficient ac-dc power supplies, each with one high current output and an
additional standby output, which can be used in a wide range of applications. Passive current share along with
internal ORing diodes allow the FNP300's to be also used in redundant, hot-swap applications. All models meet
international safety standards and display the CE Mark for the low Voltage Directive.
Model Selection
Model
Input Voltage
VAC
Output 1
Vo nom
VDC
Output 2
Io max
ADC
Vo nom
VDC
Io max
ADC
Rated Power
W
FNP300-1012
85-264
12
25
12
0.7
310
FNP300-1024
85-264
24
12.5
12
0.7
310
FNP300-1048
85-264
48
6.25
12
0.7
310
Ordering Information
Options
Suffixes to Add to Part Number
RoHS lead solder exemption
No RoHS character required.
RoHS compliant for all 6 substances
Add "G" as the last character of the part number.
MAY 30, 2006 revised to SEP 27, 2006
Page 1 of 6
www.power-one.com
FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect longterm reliability, and cause permanent damage to the converter.
Parameter
Input Voltage
Conditions/Description
Continuous
Transient, 60 ms
Min
Max
264
300
Operating Temperature
Ambient
Vi min-Vi max, Io nom, cooling by internal fan
Non-operational
0
55
Units
VAC
VAC
°C
-40
85
°C
Storage Temperature
Environmental, Mechanical, & Reliability Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Operating Humidity
Storage Humidity
Shock
Sinusoidal Vibration
MTBF
Conditions/Description
Relative humidity, non-condensing
Relative humidity, non-condensing
IEC/EN 60068-2-27, 11 ms
IEC/EN 60068-2-6
2-8 Hz
8-200 Hz
200-500 Hz
MIL-HDBK-217F Notice 2, GB, 25 °C
Min
10
5
Nom
Max
90
95
30
7.5
2
4
Units
%
%
gn
mil
gn
gn
kh
200
Isolation Specifications
The electric strength test is performed in the factory as routine test in accordance with EN 550116, IEC/EN 60950,
and UL 1950 and should not be repeated in the field. Power-One will not honor any warranty claims resulting from
electric strength field tests.
Parameter
Insulation Safety Rating
Electric Strength Test Voltage
Conditions/Description
Input/Case
Input/Output
Output/Case
Input/Case
Input/Output
Output/Case
Min
2.121
3.6
0.05
Nom
Max
Basic
Reinforced
Functional
Units
kVDC
kVDC
kVDC
EMC Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Electrostatic Discharge
Electromagnetic Field
Eletr. Fast Transients / Burst
Surge
Voltage Dips and Interruptions
RF Conducted Immunity
Description
IEC/EN 61000-4-2, level 4 (contact/air)
IEC/EN 61000-4-3, level 3
IEC/EN 61000-4-4, level 4 (direct/capacitive)
IEC/EN 61000-4-5, level 3 (L/L, L/C)
IEC/EN 61000-4-11
IEC/EN 61000-4-6
Emissions Radiated/Conducted
Harmonics
Voltage Fluctuation and Flicker
CISPR 22/EN 55022/EN 61204
IEC/EN 61000-3-2
IEC/EN 61000-3-3
MAY 30, 2006 revised to SEP 27, 2006
Page 2 of 6
Criterion
8/15 kV, criterion B
10 V/m, criterion A
2/1 kV, criterion B
1/2 kV, criterion B
Criterion B
10 VAC, AM 80%, 1 kHz,
criterion A
Class B
Class B
Pass
www.power-one.com
FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Input Voltage
Turn-On Input Voltage
Turn-Off Input Voltage
Input Frequency
Inrush Current Limitation
Power Factor
Efficiency
Conditions/Description
Ramping up
Ramping down
115/230 VAC
Vi nom, Io nom
Vi = 230 VAC, Io nom FNP300-1012
FNP300-1024
FNP300-1048
Min
85
70
70
47
Nom
115/230
50/60
Max
264
85
85
63
15/20
0.96
83
86
88
Units
VAC
VAC
VAC
Hz
A
%
Output Specifications
All specifications apply over specified input voltage, output load, and temperature range unless otherwise noted.
Parameter
Output Voltage Setpoint Accuracy
FNP300-1012
Output Voltage Setpoint Accuracy
FNP300-1024
Output Voltage Setpoint Accuracy
FNP300-1048
Output Current V1
Output Current V2
Max
0.5.
Units
% Vo nom
-0.5
0.5.
% Vo nom
Vi = 230 VAC, Io1 @ 12.5 ADC, TC = 25 °C
-0.5
0.5.
% Vo nom
FNP300-1012
FNP300-1012
0
0
25
0.7
Output Current V1
Output Current V2
FNP300-1024
FNP300-1024
0
0
12.5
0.7
Output Current V1
Output Current V2
FNP300-1048
FNP300-1048
0
0
6.25
0.7
Static Line Regulation V1
Static Load Regulation V1
(Droop Characteristic)
Hold-Up Time
Dynamic Load Regulation
Vi min-Vi max, Vi nom, 5-100% Io nom
Vi min-Vi max, Vi nom, 5-100% Io nom
-0.5
-5
Starting at Vi = 230 VAC, Po nom
20
Start-Up Time
Output Voltage Ripple and Noise
MAY 30, 2006 revised to SEP 27, 2006
Conditions/Description
Vi = 230 VAC, Io1 @ 12.5 ADC, TC = 25 °C
Min
-0.5
Vi = 230 VAC, Io1 @ 3.125 ADC, TC = 25 °C
Load change = ±33%, dIo/dt = 2A/μs
voltage deviation
recovery time
Vi nom, Io nom
Vi nom, Io nom, 20 MHz bandwidth
Page 3 of 6
-2
Nom
ADC
ADC
ADC
12.75
0.7
ADC
ADC
6.4
0.7
ADC
0.5 % Vo nom
5
% Vo nom
25
0.7
ms
2
400
1
120
% Vo nom
μs
s
mVpp
www.power-one.com
FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Input Fuse
Input Transient Protection
Output
Conditions/Description
Not user accessible
With varistor
No-load and short circuit proof
short circuit proof
overload (latch style)
Overvoltage Protection
Latch style
FNP300-1012
Latch style
FNP300-1024
Latch style
FNP300-1048
Automatic power shutdown at TC = 95 °C
Overtemperature Protection
Min
110
115
115
115
Nom
Max
6.3AT
Units
130
% Io nom
% Io nom
% Io nom
130
130
122
% Vo nom
% Vo no
% Vo no
Control
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
I2C Digital Bus
PS Seated Signal
PS Remote Shutdown
AC fail pre-warning (I2C & OC)*
DC fail (I2C & OC)*
Temperature Warning (I2C & OC)*
Fan OK (I2C & OC)*
Current Share
Status Indication
Conditions/Description
Reports information and monitors alarm functions
Contact closure to GND
TTL compatible signal, inhibited at High or TTL “1”
Supervisory AC input voltage;
Pre-warning time >6 ms
Supervisory under- and overvoltage pre-ORing diode of V1
Indicates if unit is operating normally or in overtemperature,
Pre-warning time >10 ms
Indicates if fan is operating or has failed
Droop load characteristic for V1 and V2
LEDs: DC OK (green), AC OK (green)
* Signal provided by I2C interface or by open collector (OC)
Features
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Fan speed control
µC supply voltage in-/output
(Pin 10)
MAY 30, 2006 revised to SEP 27, 2006
Conditions/Description
4 fan speed levels depending on inlet temperature
Fan speed level and temperature information available on I2C digital bus
If unit is operating: 5 to 7V is provided at pin 10.
If unit is NOT operating, pin 10 is input from a parallel connected unit for µC supply.
Page 4 of 6
www.power-one.com
FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Characteristic Curves:
Figure 1. Efficiency vs. Output Load
Figure 2. Efficiency vs. Input Voltage and Ambient Temperature, Io = Io nom
MAY 30, 2006 revised to SEP 27, 2006
Page 5 of 6
www.power-one.com
FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Mechanical Data
Mechanical Data (H, W, D)
4” (101.6mm) x 1.65” (41.9mm) x 8.5” (215.9mm)
Weight: 2.205 lb (1 kg)
Output Connector Descriptions
AI
RF
LO
W
PIN 13
PIN 1
Rear View
Connector: Molex (15-06-0241)
Output Connector
Description
12V Output
24V Output
48V Output
12V Output RTN
24V Output RTN
48V Output RTN
AC-fail, DC-fail, Temp.-fail
Power Supply Present
Signal
Serial Data Line
Serial Clock Line
Address Input Line A0
Address Input Line A1
5 to 7V
FAN OK
PS Remote Shut Down
12V Standby RTN
12V Standby
Address Input Line A2
Pin
Location
4,5,6,16,17,18
4,5,6,16,17,18
4,5,6,16,17,18
1,2,3,13,14,15
1,2,3,13,14,15
1,2,3,13,14,15
9
23
Reference
Name
Vo1
Vo1
Vo1
Vo1 RTN
Vo1 RTN
Vo1 RTN
PS_FAIL
PS_PRSNT_L
11
12
21
20
10
24
22
7
SDA
SCL
AO
A1
µC supply voltage bus
FAN_FAIL
PS_RSD_H
Vo2 RTN / Logic
Ground / 5 to 7V RTN
Vo2
A2
19
8
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
MAY 30, 2006 revised to SEP 27, 2006