DB Lectro JQX-141FF2CS5ADC60.543.3 Relay covers switching capacity from 10a to 16a Datasheet

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NHG RELAYS
JQX-141FF
R
R50007462
03001003502
C
US
E158859
29 12.6 20.6
Slim type and small occupying area can offer high density P.C.B. technique.
Employment of suitable plastic materials to be applied to high temperature and various chemical solution.
Relay covers switching capacity from 10A to 16A
Switching capacity by 5A available with 2 transfer contact forms.
Ordering Information
U
JQX-141FF C S 10 DC12V 0.54 3.5
1
2
3
4
5
6
1 Part number JQX-141FF
2 Contact arrangement 1A:1A 2A:2A 1C:1C
3 Enclosure S: Sealed type Z: Dust cover
7
4
5
6
7
2C:2C
Contact current 5A,8A,10A,16A
Coil rated voltage(V) DC:3,5,6,9,12,24,48
Coil power consumption 0.54:0.54W 0.72:0.72W
Pole-distance 3.5:3.5mm 5:5.0mm
3.5 (5.08)
0.200
1A (SPSTNO) 2A (DPSTNO) 1C (SPDT (B-M)) 2C (DPDT(B-M))
20
1A,1C
Contact Rating
Max. Switching Power
2A,2C
10A/250VAC,30VDC
Inductive
8A/250VAC,30VDC
5A/250VAC,5A/30VDC 2A/250VAC,3A/30VDC
Resistive
480W 4000VA
300W 2500VA
240W 2000VA
150W 1875VA
125VDC 380VAC
5A/250VAC,30VDC
5.08 (3.5)
0.200 0.138
6- 1.3
0.051
3.5 (5.08)
0.138 0.200
20.3
5.08 (3.5)
0.200 0.138
90W
500VA
Max. Switching Current:20A
item 3.12 of IEC255-7
Electrical
10
5
item 3.30 of IEC255-7
Mechanical
10 7
item 3.31 of IEC255-7
2C
2A
Coil voltage
VDC
Coil
resistance
10%
Pickup
voltage
VDC(max)
(80%of rated
voltage )
Release voltage
VDC(min)
(5% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Rated
Max.
003-540
005-540
006-540
009-540
012-540
024-540
048-540
3
5
6
9
12
24
48
3.9
6.5
7.8
11.7
15.6
31.2
62.4
17
47
68
155
270
1100
4400
2.4
4.0
4.8
7.2
9.6
19.2
38.4
0.15
0.25
0.30
0.45
0.60
1.20
2.40
0.54
20
8
003-720
005-720
006-720
009-720
012-720
024-720
048-720
3
5
6
9
12
24
48
3.9
6.5
7.8
11.7
15.6
31.2
62.4
12.5
36
50
115
200
820
3300
2.4
4.0
4.8
7.2
9.6
19.2
38.4
0.15
0.25
0.30
0.45
0.60
1.20
2.40
0.72
15
8
CAUTION:
20.3
150W 1250VA
Coil Parameter
Dash
numbers
5.08 (3.5)
0.200 0.138
2A
20
100m
Contact Resistance or Voltage drop
3.5 (5.08)
0.138 0.200
0.051
Resistive
Inductive
Operational
life
1A,1C
16A/250VAC;30VDC
1A:20A/120VAC
Max. Switching Voltage
0.051
2C
AgSnO2
7.5
AgCdO
Contact Material
7.5
8- 1.3
0.051
Contact Data
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
80
JQX-141FF
JQX-141FF
Operation condition
R
R50007462
03001003502
C
US
E158859
29 12.6 20.6
Features
Slim type and small occupying area can offer high density P.C.B. technique.
Employment of suitable plastic materials to be applied to high temperature and various chemical solution.
Relay covers switching capacity from 10A to 16A
Switching capacity by 5A available with 2 transfer contact forms.
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1200V
50Hz 5000V
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2
11ms
10~50Hz double amplitude 1.5mm
10N
235
2
3 0.5s
0.54W:-30~70 ; 0.72W:-30~55
85% (at 40 )
13g
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
Safety approval
6
1 Part number JQX-141FF
2 Contact arrangement 1A:1A 2A:2A 1C:1C
3 Enclosure S: Sealed type Z: Dust cover
Load
7
4
5
6
7
2C:2C
Contact current 5A,8A,10A,16A
Coil rated voltage(V) DC:3,5,6,9,12,24,48
Coil power consumption 0.54:0.54W 0.72:0.72W
Pole-distance 3.5:3.5mm 5:5.0mm
Contact Arrangement
1A (SPSTNO) 2A (DPSTNO) 1C (SPDT (B-M)) 2C (DPDT(B-M))
Contact Material
AgCdO
AgSnO2
Contact Rating
Max. Switching Power
2A,2C
Resistive
16A/250VAC;30VDC
1A:20A/120VAC
10A/250VAC,30VDC
Inductive
8A/250VAC,30VDC
5A/250VAC,5A/30VDC 2A/250VAC,3A/30VDC
Resistive
480W 4000VA
300W 2500VA
240W 2000VA
150W 1875VA
Inductive
125VDC 380VAC
Max. Switching Voltage
5A/250VAC,30VDC
2.2
0.087
6-0.4 1
0.016 0.039
item 3.12 of IEC255-7
Electrical
10
5
item 3.30 of IEC255-7
Mechanical
10 7
item 3.31 of IEC255-7
1C
79
Coil
resistance
10%
Pickup
voltage
VDC(max)
(80%of rated
voltage )
Release voltage
VDC(min)
(5% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Rated
Max.
003-540
005-540
006-540
009-540
012-540
024-540
048-540
3
5
6
9
12
24
48
3.9
6.5
7.8
11.7
15.6
31.2
62.4
17
47
68
155
270
1100
4400
2.4
4.0
4.8
7.2
9.6
19.2
38.4
0.15
0.25
0.30
0.45
0.60
1.20
2.40
0.54
20
8
003-720
005-720
006-720
009-720
012-720
024-720
048-720
3
5
6
9
12
24
48
3.9
6.5
7.8
11.7
15.6
31.2
62.4
12.5
36
50
115
200
820
3300
2.4
4.0
4.8
7.2
9.6
19.2
38.4
0.15
0.25
0.30
0.45
0.60
1.20
2.40
0.72
15
8
CAUTION:
7.5
0.295
1A
Coil voltage
VDC
5- 1.3
0.051
3.5 (5.08)
0.138 0.200
1C
16A
500VA
Coil Parameter
Dash
numbers
0.496max.
2-0.6 0.6
0.024 0.024
8- 1.3
0.051
5.08 (3.5)
0.200 0.138
2C
20
0.787
4- 1.3
0.051
3.5 (5.08)
0.138 0.200
20.3
0.799
5.08 (3.5)
0.200 0.138
6- 1.3
0.051
2A
1A
20
0.787
3.5 (5.08)
0.138 0.200
Dimensions
150W 1250VA
90W
12.6max.
29max.
1.142max.
20.3
0.799
5.08 (3.5)
0.200 0.138
Mounting (Bottom view)
10A
Max. Switching Current:20A
100m
Contact Resistance or Voltage drop
Operational
life
1A,1C
mm /inch
7.5
1A,1C
Contact Arrangement
16A/250VAC
Dimensions
4 0.3
0.157 0.012
Contact Data
16A/250VAC,30VDC
7.5
0.295
5
CQC
7.5
0.295
4
TUV
7.5
0.295
3
20.6max.
0.811max.
2
UL&CUR
NO: 16A/250VAC
NC: 12A/250VAC
0.295
Ordering Information
JQX-141FF C S 10 DC12V 0.54 3.5
1
of IEC255-19-1 and minimum sample size 24.
Safety approvals
1C
2C
1A
2A
Wiring diagram
(Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Reference Data
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Relay Corporation LTD.
Similar pages