ILPA30JW SERIES 30W Water-Proof Constant Current LED Driver – – – – – – – 2 Year Warranty Wide Input Voltage 90 to 264VAC, 47 to 63Hz Constant Output Current Available From 0.35A To 2.5A Over Voltage, Short Circuit, Lighting, and Over Temperature Protection High Efficiency (up to 86%) Active Power Factor Correction (PFC) (86% typical) IP67 Waterproof Rating, Metal Housing Comply with UL8750 & EN61347 Safety Regulation Approvals: Single Output Output Current Range Output Voltage Range Part Number (Min. / Typ. / Max.) (Min. / Max.) ILPA30JW-S250SS 2375 / 2500 / 2625 mA 7 / 12 VDC ILPA30JW-S166SS 1580 / 1660 / 1740 mA 9 / 18 VDC ILPA30JW-S125SS 1190 / 1250 / 1310 mA 13 / 24 VDC ILPA30JW-S083SS 790 / 830 / 870 mA 18 / 36 VDC ILPA30JW-S070SS 665 / 700 / 735 mA 21 / 42 VDC ILPA30JW-S045SS 428 / 450 / 472 mA 33 / 66 VDC ILPA30JW-S035SS 333 / 350 / 367 mA 43 / 86 VDC Item -S250SS, -S166SS, -S125SS use Class 2 output (USR & CNR). Item -S083SS, -S070SS -S045SS, -S035SS use Non-Class 2 output (USR & CNR). Efficiency (220VAC, Full Load) 83% 84% 85% 86% 86% 86% 87% Over Voltage Protection (Min/Typ/Max) 14 / 16 / 18 VDC 22 / 24 / 27 VDC 29 / 32 / 36 VDC 43 / 48 / 54 VDC 50 / 57 / 63 VDC 79 / 89 / 99 VDC 103 / 116 / 129 VDC Max. Output Power 30W 30W 30W 30W 30W 30W 30W Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) High Line Inrush Current Power Factor Correction Efficiency No-Load Power Consumption Line Regulation Load Regulation Over Voltage Protection Over Temperature Protection Short Circuit Protection Output Overshoot / Undershoot Start Up Time Ripple & Noise (Peak to Peak) Test Conditions Operating Voltage Min. 90 47 0 Typ. Max. 264 63 30 0.43 0.25 65 Unit VAC Hz W A A A % % W % % Vin=90 to 264VAC Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, 25°C, Cool start, Vin=230VAC Vin=110VAC 86 Io=Full Load, Vin=230VAC 82.5 87 No Load, VIn=230VAC 1 Io=Full Load 1 Vin=230VAC 3 Latch mode. The power unit shall return to normal operation only after the power is turn-on again. (Please refer to output table.) 110 °C No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. When power on or off 10 % Io=Full Load, Vin=100VAC 3 S Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 2 % Vo uF electrolytic capacitor. Conditions Parameter Test Conditions Operating Temperature Humidity: 10% RH to 100% RH Storage Temperature Humidity: 5% RH to 100% RH Operation temperature at 25°C, calculated per MIL-HDBK-217F Life Time at 25°C ambient temperature No output power derating from -35°C to 60°C Min. -35 -40 0.3M 0.08M Typ. Max. 60 85 Unit °C °C Hours Hours Approvals and Compliance Parameter EMI EMS Safety UL/c-UL, CE Waterproof Standards EN55015 EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-1-1, EN61547 UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13 IP67 Rating Mechanical Parameter Dimension, Net Weight Specification 162x34.5x42.5mm (6.38x1.36x1.67 inches) 460g