ETC2 BVL061000003K Complies with emi-rfi regulation Datasheet

BVL
WIDE RANGE LEAD ACID
CHARGERS
BVL WIDE RANGE LEAD
ACID CHARGERS
BVL
Ault Part No.
Voltage Output
DC
Amps
Fast Charge Float Charge Max
Volts DC
Volts DC
Watts
7.35
•
100-250 VAC
BVL061000003K
6V
1.0
•
In Case IEC 320
BVL062000003K
6V
2.0
•
Automatic Fast/Float Function
BVL120600003K
12V
0.6
•
LED Indicators
BVL121200003K
12V
1.2
•
Charges Lead Acid Batteries
BVL240300003K
24V
0.3
•
Optimizes Battery Life
BVL240600003K
24V
0.6
•
Meets Safety Agency Requirements
•
Complies with EMI-RFI Regulations
Ault
AultPart
PartNo.
No.Key
Key
•
Impact Resistant Polycarbonate Enclosure
BVL
06
100
00
03
K
Product
Family
Name
Voltage
DC
Output
Amps
Denotes standard
or custom
requirements
Connector
Manufacturing
Location
•
Private Label Marking Available
•
3 Year Warranty
•
Modified and Custom Designs Also
Available
A U LT I N C O R P O R AT E D
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL [email protected] | WEB www.aultinc.com
© Copyright 2002 Ault Inc.
6.90
7.35
14.70
14.70
13.80
8.82
17.64
29.40
27.60
8.82
17.64
BVL
WIDE RANGE LEAD ACID
CHARGERS
Input
Environmental
Voltage
100-250 VAC -10%, +6%
Operating Temperature
5º to 40º C with no derating
Line Frequency
47 - 63 Hz
Storage Temperature
-30º to +85º C
Current
0.5 (Lower current with higher voltage)
Relative Humidity
Protection
Internal primary current fuse
Inrush limiting
5% to 95% non-condensing
0-10,000 feet
Altitude
0-10,000 feet
Cooling
Convectional - non vented case
Electrical
Topology
Switching - DC battery charger
Mechanical
Dielectric Withstand
3000 VAC, 4242 VDC primary- secondary
1500 VAC, 2121 VDC primary-ground
500 DC secondary-ground
Case and Dimensions
LP6 - Desktop
4.20 L x 2.60 W x 1.46 H (in)
107 L x 66 W x 37 H (mm)
EMI
Complies with EMC Directives
Case Material
Black 94V0 polycarbonate
CE
CE Compliant
Weight
8 ounces, 210 grams (excluding cord)
MTBF
100,000 calculated hours
Cords and Connectors
MTBF
100,000 calculated hours
Protection
Foldback overcurrent.
Short circuit protection
6 ft., 2 conductor, 18 AWG, Ault #3
connector. Other connectors are also
available.
Safety Approvals
Agency Listings
CULus 60950; TUV EN60950
Connector
Input Configuration
IEC320
w/ground
C14
(F)
Configuration: In Case IEC320 with ground
LED Indicators
Indicator #1 (Green)
On (unit energized)
Off (unit de-energized)
Indicator #2 (Amber)
On (battery discharged)
Off (battery charged)
Pinout Code
Center contact: positive
Description
Switchcraft 760 plug or equivalent
Suggested Mating
Switchcraft 712A jack or equivalent
Other Connectors are available by special order
A U LT I N C O R P O R AT E D
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL [email protected] | WEB www.aultinc.com