MORNSUN B2415S/D-W2 Single output dc-dc converter Datasheet

B_S(D)-W2 Series
0.25W, FIXED INPUT, ISOLATED & UNREGULATED
SINGLE OUTPUT DC-DC CONVERTER
RoHS
PRODUCT PROGRAM
FEATURES
● SIP/DIP Package
● 1KVDC Isolation
● Temperature Range: -40°C ~ +85°C
● No Heatsink Required
● Internal SMD Construction
● No External Component Required
● Industry Standard Pinout
● RoHS Compliance
Input
Part
Number
Voltage (VDC)
Nominal
B0303S/D-W2*
B0305S/D-W2
3.3
The B_S-W2/B_D-W2 series are specially
designed for applications where a group of polar
power supplies are isolated from the input power
supply in a distributed power supply system on a
output
ripple
noise
are
not
demanding.
5
64
8
64
5
64
9
28
3
65
5
4.5-5.5
B0512S/D-W2
12
21
2
65
B0515S/D-W2
15
17
2
65
B1203S/D-W2
3.3
76
8
62
B1205S/D-W2
B1212S/D-W2
12
10.8-13.2
B1215S/D-W2
B2415S/D-W2
the
62
50
76
1) Where the voltage of the input power supply
and
8
5
50
B2412S/D-W2
and output (Isolation voltage ≤1000VDC);
Min.
76
5
B2405S/D-W2
3) Where the regulation of the output voltage
Max.
3.3
3.3
These products apply to:
2) Where isolation is necessary between input
24
21.6-26.4
5
50
5
63
12
21
2
65
15
17
2
66
5
50
5
63
12
21
2
65
15
17
2
66
Note:
1.Models listed with strike-through text have been officially discontinued.
2.*Designing.
COMMON SPECIFICATIONS
Item
Test conditions
Min.
Typ.
Storage humidity
Such as: purely digital circuits, ordinary low
frequency analog circuits, and IGBT power
device driving circuits.
Max.
Units
95
%
Operating temperature
-40
85
Storage temperature
-55
125
Temp. rise at full load
Lead temperature
15
1.5mm from case for 10 seconds
Free air convection
Case material
MODEL SELECTION
Short circuit protection*
B0505S-W2
MTBF
Weight
°C
25
300
Cooling
Rated Power
Packa ge Style
Output Voltage
Inp ut Voltage
Produc t Series
Efficiency
(%, Typ)
B0505S/D-W2
circuit board.
is fixed (Voltage variation ≤ ±10%);
2.97-3.63
Current (mA)
Voltage
(VDC)
B0503S/D-W2
B0509S/D-W2
APPLICATIONS
Range
Output
Plastic(UL94-V0)
1
3500
s
k hours
B_S-W2 Series
1.2
B_D-W2 Series
1.8
g
*Supply voltage must be discontinued at the end of short circuit duration.
ISOLATION SPECIFICATIONS
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development
center, Science Ave., Guangzhou Science City,
Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
Item
Test conditions
Min.
Isolation voltage
Tested for 1 minute and 1mA max
1000
Isolation resistance
Test at 500VDC
1000
Isolation capacitance
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Typ.
Max.
Units
VDC
MΩ
85
pF
Specifications subject to change without notice.
B_S(D)-W2
B/2-2012
Page 1 of 3
OUTPUT SPECIFICATIONS
Item
Test conditions
TYPICAL CHARACTERISTICS
Min.
Typ.
Output power
Line regulation
Load regulation
For Vin change of ±1%(3.3V output)
Max.
Units
0.25
W
±1.5
For Vin change of ±1%(others output)
±1.2
10% to 100% load(3.3V output)
15
20
10% to 100% load (5V output)
12.8
15
10% to 100% load (9V output)
8.3
15
10% to 100% load (12V output)
6.8
15
10% to 100% load (15V output)
6.3
15
Output voltage accuracy
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
Switching frequency Full load, nominal input
%
See tolerance envelope graph
50
±0.03
%/°C
75
mVp-p
110
kHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of
Power Converter section, application notes.
Operating Temp.(oC)
APPLICATION NOTE
1) Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the
RECOMMENDED CIRCUIT
minimum output load could not be less than 10% of the full load. If the actual output
power is very small, please connect a resistor with proper resistance at the output end in
L
L
+Vo
Vin
DC DC
Cin
Cout
GND
0V
parallel to increase the load.
(Figure 1)
2) Recommended circuit
If you want to further decrease the input/output ripple, an “LC” filtering network may be
connected to the input and output ends of the DC/DC converter, see (Figure 1).
It should also be noted that the inductance and the frequency of the “LC” filtering network
Vin
+Vo
REG
DC DC
GND
0V
should be staggered with the DC/DC frequency to avoid mutual interference. However, the
capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
application field.
REG
Vin
startup problem might arise. It’s not recommended to connect any external capacitor in the
GND
+Vo
DC DC
0V
(Figure 2)
3) Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current
protection is a linear voltage regulator with overheat protection that is connected to the
input or output end in series (Figure 2).
4) Overload Protection
Under normal operating conditions, the output circuit of these products has no
protection against overload. The simplest method is to connect a self-recovery fuse in
series at the input end or add a circuit breaker to the circuit.
5) No parallel connection or plug and play
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
B_S(D)-W2
B/2-2012
Page 2 of 3
OUTLINE DIMENSIONS & PIN CONNECTIONS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
7.70[0.3 03]
8.20[0.323]
10.00[0.394]
0.50 [0.0 20]
(Front V iew)
B _ S Series
B _ D Series
B _ S Ser ies
1
(Fron t View)
4.10 [0.161]
2
3
4
∅1.00 [0.0 39]
B _ D Series
4.10 [0.161]
5.08 [0.200]
7
12.70 [0.500]
7.62[0.300]
7
5
0.50 [0.020]
B _ D Series
Pin
B_ D
GND
1
2
Vin
4
3
0V
5
Vin
+Vo
4
+Vo
7
0V
Note:
Unit:mm[inch]
Pin se ction tolerances:± 0.10mm[± 0.004inch]
Gene ral tolerances:± 0.25mm[± 0 .010inch]
9.60 [0.378]
12.50 [0.492]
10.50[0.4 13]
FOOTPRINT DETAILS
GND
1
TUBE OUTLINE DIMENSIONS
B _ S Series
∅1.00 [0.039]
FOOTP RINT DETAIL S
B_ S
Pin
4
Note: grid 2.54*2.54mm .
12.40[0.48 8]
4
(Botto m View)
16.90[0.665]
3
(Bottom V iew)
4
7.62[0.3 00]
2
1
10.00[0.3 94]
1
0.90 [0.035]
6 .00[0.236]
0.30[0.012 ]
0.3 0 [0.012]
11.60[0.4 61]
0.50[0 .020]
1
5
16.50[0.650]
7.62 [0.3 00]
3.50[0 .138]
4.90[0.193 ]
Note:
Unit :mm[inch]
General tolerances: ± 0.50mm[± 0.020inch]
L=530mm[20.866inch] Devices per tube: 43pcs(B_S) 40pcs(B_D)
L=220mm[8.661inch] Devices per tube: 17pcs(B_S) 16pcs(B_D)
Short tube inner packaging dimensions: L*W*H=255*170*80mm;
Short tube outer packaging dimensions(with six inner packaging boxes):
L*W*H=375*280*270mm;
Long tube inner packaging dimensions: L*W*H=580*200*100mm;
Long tube outer packaging dimensions(with two inner packaging boxes) :
L*W*H=600*215*220mm;
Long tube outer packaging dimensions(with three inner packaging boxes) :
L*W*H=600*215*325mm.
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the
life of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. Only typical models listed, other models may be different, please contact our technical person for more details.
4. In this datasheet, all the test methods of indications are based on corporate standards.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
B_S(D)-W2
B/2-2012
Page 3 of 3
Similar pages