(Ø8x10mm) 3-Electrode Gas Discharge Tubes 10KA 1:Dimension(mm) 3:Features 2:Main Applications •PCI Cards protection •Telephone/Fax/Modem protection •single line protection •ADSL/XDSL Splitter,Power Supply •Surge Protection Device/Surge Protector •100% Lead-Free(RoHs Compliant ) •Non-Radioactive •Low capacitance (≤1pF) •Fast Response-time,High Insulation Resistance. •Small size :Ø8x10(mm) 4 Electrical Characteristics DC Spark-over Voltage @ 100V/S Impulse Spark-over Voltage Impulse Spark-over Voltage @100V/μs @1KV/μs V V V GΩ 10 Times A PF H3R8-75SMD 75±20% <500 <600 >1 10KA 10 ≤1 H3R8-90SMD 90±20% <500 <600 >1 10KA 10 ≤1 H3R8-150SMD 150±20% <500 <600 >1 10KA 10 ≤1 H3R8-230SMD 230±20% <600 <700 >1 10KA 10 ≤1 H3R8-250SMD 250±20% <600 <700 >1 10KA 10 ≤1 H3R8-350SMD 350±20% <900 ≤ 1000 >1 10KA 10 ≤1 H3R8-420SMD 420±20% <900 ≤ 1000 >1 10KA 10 ≤1 H3R8-470SMD 470±20% <1100 ≤ 1200 >1 10KA 10 ≤1 H3R8-600SMD 600±20% <1200 ≤ 1300 >1 10KA 10 ≤1 Part Number Insulation Resistance Impulse discharge current(8/20μs) AC discharge current (50Hz,1s,10ti Capacitan ce (1MHz) mes) Packing Quantity : 100PCS Specifications are subject to change without notice [email protected] 1 HUAAN LIMITED www.huaandz.com Tel:+86-755-27465585