MORNSUN LD05-20B09 5w, ac/dc converter Datasheet

AC/DC Converter
LD05-20Bxx Series
FEATURES
5W, AC/DC converter
z Universal input voltage range:
85~264VAC/100~370VDC
z AC and DC dual-use(input from the same
terminal)
z High efficiency, high power density
z Output short circuit, over-current, over-voltage
protections
z Meets UL60950, EN60950 standards (Pending)
z Mounting :PCB mounting, Chassis mounting,
Din-Rail mounting available
RoHS
LD05-20Bxx series---- is a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC input
voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, and is UL & CE certified,
and widely used in industrial, electricity, instruments, telecommunication and civil applications.
Note: Please refer to Design Reference when module being used in a bad EMC environment.
Selection Guide
Certification
UL/CE
(Pending)
Part No.
Output Power
Nominal Output Voltage and
Current(Vo/Io)
Efficiency
(230VAC, %/Typ.)
Max. Capacitive Load*
(μF)
LD05-20B03
4.2W
3.3V/1250mA
74
4000
LD05-20B05
5V/1000mA
78
4000
LD05-20B09
9V/550mA
78
1000
12V/420mA
80
820
15V/333mA
82
820
24V/230mA
83
330
LD05-20B12
5W
LD05-20B15
LD05-20B24
5.5W
Note: *Test without external circuit.
Input Specifications
Item
Operating Conditions
Input Voltage Range
Min.
Typ.
Max.
Unit
AC input
85
--
264
VAC
DC input
100
--
370
VDC
Hz
47
--
63
110VAC
--
--
150
230VAC
--
--
70
110VAC
--
10
--
230VAC
--
20
--
Input Frequency
Input Current
Inrush Current
Recommended External Input
Fuse(Special package series include fuse)
Hot Plug
mA
A
1A/250V, slow fusing, necessary
Unavailable
2015.03.18-B/1
Page 1 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD05-20Bxx Series
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
3.3V output
--
±3
--
Other output
--
±2
--
Line Regulation
Full load
--
±0.5
--
Load Regulation
10%-100% load
--
±1
--
20MHz
3.3V/5V output
--
60
120
Other output
--
50
100
Temperature Coefficient
--
±0.02
--
%/℃
Stand-by Power Consumption
--
--
0.3
W
Output Voltage Accuracy
Ripple & Noise*
bandwidth
(peak-peak value)
Unit
%
mV
Short Circuit Protection
Hiccup, continuous, self-recovery
Over-current Protection
≥110%Io self-recovery
Over-voltage Protection
Hold-up Time
Over-voltage shutdown
110VAC input
--
12
--
230VAC input
--
80
--
ms
Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation.
General Specifications
Item
Operating Conditions
Min.
Typ.
Test time: 1min
Max.
Unit
VAC
4000
--
--
Operating Temperature
-25
--
+70
Storage Temperature
-25
--
+105
Storage Humidity
--
--
95
%RH
Switching Frequency
--
--
140
KHz
+55℃~+70℃
2.0
--
--
+0℃~-25℃
2.0
--
--
Isolation Voltage
Input-output
Power Derating
Safety Standard
IEC60950/EN60950/UL60950
Safety Certification
EN60950/UL60950 (Pending)
Safety Class
CLASS I I
MTBF
MIL-HDBK-217F@25℃ > 300,000 h
℃
%/℃
Physical Specifications
Black flame-retardant and heat-resistant plastic
(UL94-V0)
Casing Material
Dimension
Horizontal package/A2 chassis mounting/A4 Din-Rail mounting /
A2S chassis mounting/A4S Din-Rail mounting
Refer to the Dimensions
Weight
Horizontal package/A2 chassis mounting/A4 Din-Rail mounting /
A2S chassis mounting/A4S Din-Rail mounting
31g/80g /121g /52g /70g (Typ.)
Cooling Method
Free convection
EMC Specifications
EMI
CE
CISPR22/EN55022, CLASS B
RE
CISPR22/EN55022, CLASS B
ESD
IEC/EN61000-4-2
±6KV/8KV
perf. Criteria B
RS
IEC/EN61000-4-3
10V/m
perf. Criteria A
IEC/EN 61000-4-4
±2KV
perf. Criteria B
IEC/EN 61000-4-4
±4KV (See Fig. 2 for recommended circuit)
perf. Criteria B
IEC/EN 61000-4-5
±1KV
perf. Criteria B
IEC/EN 61000-4-5
±2KV/±4KV (See Fig. 2 for recommended circuit)
perf. Criteria B
CS
IEC/EN61000-4-6
10Vr.m.s
perf. Criteria A
PFM
IEC/EN61000-4-8
10A/m
perf. Criteria A
Voltage dips, short interruptions and
voltage variations immunity
IEC/EN61000-4-11
EFT
EMS
Surge
0%-70%
perf. Criteria B
2015.03.18-B/1
Page 2 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD05-20Bxx Series
Output Power Percentage(%)
Output Power Percentage(%)
Product Characteristic Curve
Temp erat ure D erating Cur ve
100
80
70
50
Input Voltage: 11 0~2 40 VA C
14 0~3 40 VDC
25
-25
-10
0
In put Voltage Derating Cu rve
100
80
60
50
40
20
110
140
85
100
55 70
A mbient Tem pe rature(℃ )
240 264 VA C
340 370 VDC
Input voltage
Note: ①When input 85~110VAC/240~264VAC/100~140VDC/340~370VDC, it need to be voltage derated on basis of temperature derating;
②This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
Efficiency Vs Input Voltage(Full Load)
90
85
LD05-20B24
LD05-20B12
LD05-20B05
Efficiency(%)
Efficiency(%)
80
75
70
65
85
LD05-20B24
80
LD05-20B12
LD05-20B05
75
70
65
60
60
55
55
50
50
85
110
180
230
Efficiency Vs Output Load(Vin=230VAC)
90
10
264
20
30
40
50
60
70
80
90
100
Output Power Percentage(%)
Input Voltage(VAC)
Design Reference
1. Typical
application circuit
FU SE
AC(L)
NT C
AC ( L) +Vo
C1
+
RL
M OV
AC(N )
Model
LD05-20B03
LD05-20B05
LD05-20B09
LD05-20B12
LD05-20B15
LD05-20B24
C2
- Vo
AC ( N)
Fig. 1
C1(μF)
C2(μF)
220
220
100
100
100
47
1
Note:
Output filtering capacitor C2 is a electrolytic capacitor, it is recommended to use high frequency and low impedance electrolytic capacitor. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Output capacitor withstand voltage derating should be 80% or above. C1 is
ceramic capacitor, which is used to filter high-frequency noise. External input NTC is recommended to use 12D-5; External input MOV is recommended to use
S14K350.
2. EMC solution-recommended circuit
Can use MORNSUN’s FC-LX1D
FUSE
L1
NTC
LCM
AC(L)
AC(L)
+Vo
CY1
MOV
C1
C2
RL
+
ACDC
CX
CY2
-Vo
AC(N)
AC(N)
Fig 2
2015.03.18-B/1
Page 3 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD05-20Bxx Series
EMC solution-recommended circuit PCB layout
Fig 3
Note: Suggestions for safety regulation and wiring width: wire width ≥3mm, distance between wires ≥6mm, and distance between wire and ground ≥6mm
Element model
MOV
CX
L1
CY1
CY2
LCM
FUSE
Recommended value
S14K350
0.1μF/275VAC
4.7uH/2.0A
1nF/400VAC
1nF /400VAC
2.2mH, recommended to use MORNSUN’s FL2D-10-222
1A/250V, slow fusing, necessary
3.For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to
download the Selection Guide of EMC Filter
Dimensions and Recommended Layout
2015.03.18-B/1
Page 4 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD05-20Bxx Series
LD05-20BxxA2 Chassis mounting Dimensions
LD05-20BxxA4 Din-Rail mounting Dimensions
2015.03.18-B/1
Page 5 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD05-20Bxx Series
LD05-20BxxA2S Chassis mounting Dimensions
LD05-20BxxA4S Din-Rail mounting Dimensions
2015.03.18-B/1
Page 6 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD05-20Bxx Series
Notes:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com . Packing
bag number: 58220003(Horizontal package), 58220022(A2S/A4S package), 58220010(A2/A4 package);
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25 ℃, humidity<75% with nominal
4.
5.
6.
7.
input voltage and rated output load;
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model
products may exceed the requirements mentioned above. Please contact our technicians directly for specific information;
We can provide product customization service;
Specifications are subject to change without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2015.03.18-B/1
Page 7 of 7
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages