NTE D40 Circuit breaker Datasheet

Circuit Breakers
R58 Series
Thermal Circuit Breaker
D40
Features
.250” (6.35mm) Quick Connect Terminals
Cannot be Manually Tripped
Visual Trip Indicator
Push Button to Reset Breaker
.440
(11.18)
1.375
(34.93)
.050 (1.27) Max
Closed Position
.660 (16.76)
.500 (12.7)
.850
(21.59)
.425
(10.8)
1.375
(34.93)
Knurled Nut
Hex Nut
M11*1 Thread (Note)
.312 (7.92)
Note: 1A and 2A types have a 7/16−28 Thread
NOTE: Indicator plate shown may NOT be available on all devices.
.078 (1.98)
Current Rating
Amps
NTE Type No.
Maximuml Resistance
Ohms
R58−1A
1.0
1.35 (Typ)
R58−2A
2.0
0.32 (Typ)
R58−3A
3.0
0.225
R58−4A
4.0
0.225
R58−5A
5.0
0.225
R58−6A
6.0
0.175
R58−7A
7.0
0.175
R58−8A
8.0
0.175
R58−10A
10.0
0.125
R58−12A
12.0
0.050
R58−15A
15.0
0.040
R58−20A
20.0
0.030
R58−25A
25.0
0.020
R58−30A
30.0
0.020
R58−35A
35.0
0.020
Flat
.556
(14.12)
.125 (3.18)
Straight Knurl
24 Pitch
Hex Nut
.625
(15.88)
Knurled Nut
Electrical Specifications
Electrical Characteristics (@ 25 C)
Calibration: Will continuously carry 100% of rating.
May trip between 101% and 144%, but must trip at 145%
of rating at +25 C
Maximum Operating Voltages: 50 VDC; 250 VAC, @ 50/60 Hz
Dielectric Strength: 1500VAC RMS
Resettable Overload Capacity: Ten times rated current
Interrupt Capacity:
2000 Amps at 50 VDC
1000 Amps at 250 VAC
Trip Times
Mechanical Characteristics
1 to 4 Amp Types
5 to 35 Amp Types
Rated Load
Trip Times
Rated Load
100%
No Trip
100%
Trip Times
No Trip
145%
Trip in 1 Hour
145%
Trip in 1 Hour
200%
10 to 45 Sec.
200%
6.0 to 30 Sec.
400%
3.0 to 14.0 Sec.
400%
1.6 to 4.5 Sec.
600%
1.4 to 7.0 Sec.
600%
0.60 to 1.7 Sec.
800%
0.75 to 4.3 Sec.
800%
0.25 to 0.90 Sec.
1000%
0.50 to 3.4 Sec.
1000%
0.15 to 0.65 Sec.
Termination: .250 (6.35) Quick Connect Terminals
Shock: Withstands to 10 g
Endurance Cycling: Over 1000 cycles at 200% of rated load.
Vibration: Withstands to 10 g at 10 to 55 Hz.
Weight: Less than 1.5 ozs. (42.5 g)
ACCESSORIES
NTE
TYPE NO.
R58−Boot (Note 1)
DESCRIPTION
Protective Boot w/M11 Thread, Clear Silicon, Waterproof
Note 1. Not for use with 1A and 2A types.
92
NTE Electronics, Inc.
Voice (973) 748−5089
FAX (973) 748−6224
http://www.nteinc.com
Similar pages