The ABC225 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 225 W of output power and a variety of single and multiple output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. • 2 x 4 x 1 Inches Form Factor • 225 W with Forced Air Cooling • Efficiencies up to 94% • -40 to 70 °C Operating Temperature • 12 V Fan Output, Thermal Shut-Down Feature • 3.37 Million Hours, Telcordia - SR332-Issue 3 MTBF • Standby Power <0.5 W • RoHS Compliant • CE Marked • Instrumentation • Renewable Energy • Lighting • Test and Measurement • Industrial Applications • Robotics • Applied Computing • Wireless Communication ABC225 Series 2 MODEL NUMBER1 DESCRIPTION ABC225-1T12L ABC225-1012L ABC225-1T15L ABC225-1015L ABC225-1T24L ABC225-1024L ABC225-1T30L ABC225-1030L ABC225-1T48L ABC225-1048L ABC225-1T58L ABC225-1058L Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector Screw Terminal Molex Connector VOLTAGE MAX. LOAD (CONVECTION) (112.5 W) MAX. LOAD (CONVECTION) (120 W) MAX. LOAD (13 CFM) MIN. LOAD RIPPLE & NOISE2 12 V 9.37 A 10.0 A 18.75 A 0.0 A 1% 15 V 7.5 A 8.0 A 15 A 0.0 A 1% 24 V 4.68 A 5.0 A 9.37 A 0.0 A 1% 30 V 3.75 A 4.0 A 7.5 A 0.0 A 1% 48 V 2.34 A 2.5 A 4.68 A 0.0 A 1% 58 V 1.94 A 2.07 A 3.88 A 0.0 A 1% COVER-225-XBC3 metal cover kit accessory Specifications are for nominal input voltage, 25°C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal (Derate from 100% at 100 VAC to 90% at 85 VAC) 85-264 VAC / 390 VDC Input Frequency 47-63 Hz Input Current 115 VAC: 230 VAC: 2.2 A max. 1.1 A max. No Load Power Typical < 0.5 W 115 VAC: 230 VAC: 264 VAC: Typical (N.A. For Class II Option) Touch current: 25 A 45 A 75 A 300 µA <100 µA Power Factor With Full Load >0.95 Switching Frequency PFC: PWM: 70 to 130 kHz 50-80 kHz Inrush Current Leakage Current 1 For Class II (without input Earth pin) add suffix -2 (e.g.: ABC225-1012L-2). Ensure non-metallic mounting stud when installing a Class II product. 2 Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 3 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. [email protected] ABC225 Series 3 PARAMETER DESCRIPTION / CONDITION SPECIFICATION Output Power4 With 13 CFM: Convection: 48 V: 24 V, 30 V: 12 V, 15 V: 225 W: 110 W: 225 W Up to 120 W 94% 93% 92% 10 ms 16 ms Efficiency Hold-up Time Line Regulation +/-0.5% Load Regulation +/-0.5% Transient Response 25% step load change, at 0.1A/µs slew rate, 50% duty cycle, 50 Hz = 4% Recovery time < 5 ms Rise Time Typical 55 ms Set Point Tolerance5 Output Voltage Adjustment +/-1% 6 +/-3% Over Current Protection >110% Over Voltage Protection Short Circuit Protection 110 to 140% Hiccup mode Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; with external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B PARAMETER DESCRIPTION / CONDITION SPECIFICATION Isolation Voltage Input to Output: (For ITE application) Input to GND: (Not Applicable For Class II Option) 3000 VAC 1500 VAC Safety Standard(s) Approved to the latest edition of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1; Class1 SELV. Agency Approvals Nemko, UL, C-UL CE mark Complies with LVD Directive 4 Combined output power of main output, fan supply shall not exceed max. Power rating. Fan supply output voltage tolerance including set point accuracy, line & load regulation is +/-10% and Ripple & noise is less than 10%. 6 Adjustment potentiometer is located on the SMT side of the PCB. 5 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00554_AG Asia-Pacific +86 755 298 85888 ABC225 Series 4 PARAMETER Operating Temperature7 DESCRIPTION / CONDITION SPECIFICATION Start-up is guaranteed, with spec deviation, see Fig. 1 -40 to +70°C -40 to 0°C Storage Temperature -40 to +85°C Cooling With 13 CFM forced air cooling With natural convection cooling at 100 to 264 VAC 225 W Up to 120 W Relative Humidity Noncondensing 5% to 95% Altitude Operating: Nonoperating: 16,000 ft. 40,000 ft. Reliability MTBF according to Telcordia -SR332-issue 3: 3.37 million hours Convection load: 120 W up to 40 °C De-rate between 40-50 °C @ 0.625% per °C De-rate above 50 °C @ 2.33% per °C Forced air cooled load: 225 W up to 50°C De-rate above 50 °C @ 2.5% per °C Figure 1. Derating Curve Figure 2. Efficiency Graph at 115 VAC 7 Figure 3. Efficiency Graph at 230 VAC Output ripple can be more than 10% of the output voltage. [email protected] ABC225 Series CONNECTOR PIN 5 DESCRIPTION/CONDITION MANUFACTURER / PN AC Line Not Fitted AC Neutral Molex: 26-60-4030 Mating: 09-50-3031; Pins: 08-50-0106 AC Input Connector J1 Pin 1 Pin 2 Pin 3 DC Output Connector J2 Pin 1,2,3 Pin 4,5,6 V1 +VE V1 - VE Pin 1 Pin 2 FAN +VE FAN - VE Aux (Fan) Output J3 Screw Terminal (Option 1) Molex Connector (Option 2) Molex: 39357 Series or equivalent Molex: 26-60-4060 Mating: 09-50-3061; Pins: 08-50-0106 AMP :640456-2 Mating: 640440-2 PARAMETER DESCRIPTION/CONDITION Weight 200 g approx. Dimensions 50.8 x 101.6 x 25.4 mm (2 x 4 x 1 inch) Cooling8 225 W with 13 CFM forced air cooling (refer Mechanical Drawing) Up to 120 W with natural convection cooling (refer Derating Curve) Figure 4. Mechanical Drawing – Screw Terminal (Option 1) 8 225 W with 13CFM forced air cooling and 120 W with natural convection cooling at 100 to 264 VAC. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00554_AG Asia-Pacific +86 755 298 85888 6 ABC225 Series Figure 5. Mechanical Drawing – Molex Connector (Option 2) NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3 Washer, if used, to have dia of 6.5 mm max. NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. [email protected]