TI CDC5801ADBQR Low jitter clock multiplier and divider with programmable delay Datasheet

SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
D Low Jitter Clock Multiplier by x4, x6, x8.
D
D
D
D
D
D
D
D
D
D
D
D
Input Frequency Range (19 MHz to
125 MHz). Supports Output Frequency
From 150 MHz to 500 MHz
Fail-Safe Power Up Initialization
Low Jitter Clock Divider by /2, /3, /4. Input
Frequency Range (50 MHz to 125 MHz).
Supports Ranges of Output Frequency
From 12.5 MHz to 62.5 MHz
2.6 mUI Programmable Bidirectional Delay
Steps
Typical 8-ps Phase Jitter (12 kHz to 20 MHz)
at 500 MHz
Typical 2.1-ps RMS Period Jitter (Entire
Frequency Band) at 500 MHz
One Single-Ended Input and One
Differential Output Pair
Output Can Drive LVPECL, LVDS, and
LVTTL
Three Power Operating Modes to Minimize
Power
Low Power Consumption (Typical 200 mW
at 500 MHz)
Packaged in a Shrink Small-Outline
Package (DBQ)
No External Components Required for PLL
Spread Spectrum Clock Tracking Ability to
Reduce EMI
D Applications: Video Graphics, Gaming
Products, Datacom, Telecom
D Accepts LVCMOS, LVTTL Inputs for
D
D
REFCLK Terminal
Accepts Other Single-Ended Signal Levels
at REFCLK Terminal by Programming
Proper VDDREF Voltage Level (For
Example, HSTL 1.5 if VDDREF = 1.6 V)
Supports Industrial Temperature Range of
−40°C to 85°C
DBQ PACKAGE
(TOP VIEW)
VDDREF
REFCLK
VDDP
GNDP
GND
LEADLAG
DLYCTRL
GNDPA
VDDPA
VDDPD
STOPB
PWRDNB
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9
16
10
15
11
14
12
13
P0
P1
VDDO
GNDO
CLKOUT
NC
CLKOUTB
GNDO
VDDO
MULT0/DIV0
MULT1/DIV1
P2
NC − No internal connection
description
The CDC5801A device provides clock multiplication and division from a single-ended reference clock
(REFCLK) to a differential output pair (CLKOUT/CLKOUTB). The multiply and divide terminals (MULT/DIV0:1)
provide selection for frequency multiplication and division ratios, generating CLKOUT/CLOUTKB frequencies
ranging from 12.5 MHz to 500 MHz with a clock input reference (REFCLK) ranging from 19 MHz to 125 MHz.
See Table 1 and Table 2 for detail frequency support.
The implemented phase aligner provides the possibility to phase align (zero delay) between
CLKOUT/CLKOUTB and REFCLK or any other CLK in the system by feeding the clocks that need to be aligned
to the DLYCTRL and the LEADLAG terminals.
The phase aligner also allows the user to delay or advance the CLKOUT/CLKOUTB with steps of 2.6 mUI (unit
interval). For every rising edge on the DLYCTRL terminal, the output clocks are delayed by 2.6-mUI step size
as long as there is low on the LEADLAG terminal. Similarly, for every rising edge on the DLYCTRL terminal, the
output clocks are advanced by 2.6-mUI step size as long as there is high on the LEADLAG terminal. The
CDC5801A has a fail-safe power up initialization state-machine which supports proper operation under all
power up conditions. As the phase between REFCLK and CLKOUT/CLKOUTB is random after power up, the
application may implement a self calibration routine at power up to produce a certain phase start position, before
programming a fixed delay with the clock on the DLYCTRL terminal.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  2005, Texas Instruments Incorporated
!"# $ %&'# "$ (&)*%"# +"#',
+&%#$ %! # $('%%"#$ (' #-' #'!$ '."$ $#&!'#$
$#"+"+ /""#0, +&%# (%'$$1 +'$ # '%'$$"*0 %*&+'
#'$#1 "** (""!'#'$,
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
Depending on the selection of the mode terminals (P0:2), the device behaves as a multiplier (by 4, 6, or 8) with
the phase aligner bypassed or as a multiplier or divider with programmable delay and phase aligner functionality.
Through the select terminals (P0:2) user can also bypass the phase aligner and the PLL (test mode) and output
the REFCLK directly on the CLKOUT/CLKOUTB terminals. Through P0:2 terminals the outputs could be in a
high impedance state. This device has another unique capability to be able to function with a wide band of
voltages on the REFCLK terminal by varying the voltage on the VDDREF terminal.
The CDC5801A has a fail-safe power up initialization state-machine which supports proper operation under all
power up conditions.
The CDC5801A device is characterized for operation over free-air temperatures of −40°C to 85°C.
functional block diagram
PWRDWNB
P0
P1
P2
STOPB
Control Logic
PLLCLK
Phase Aligner
Bypass MUX
PLL
REFCLK
CLKOUT
B
Phase
Aligner
Divider
Ratio
VDDREF/2
φD
A
VDDPD/2
2
2
MULT0/DIV0
MULT1/DIV1
DLYCTRL
POST OFFICE BOX 655303
LEADLAG
• DALLAS, TEXAS 75265
CLKOUTB
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
FUNCTION TABLE†
MODE
P0
P1
P2
CLKOUT/CLKOUTB
Multiplication with programmable
delay and phase alignment active‡
0
0
0
REFCLK multiplied by ratio per Table 1 selected by MULT/DIV terminals. Outputs
are delayed or advanced based on DLYCTRL and LEADLAG terminal
configuration.
Division with programmable delay
and phase alignment active ‡
0
0
1
REFCLK divided by ratio per Table 2 selected by MULT/DIV terminals. Outputs
are delayed or advanced based on DLYCTRL and LEADLAG terminal
configuration.
Multiplication only mode (phase
aligner bypassed) §
1
0
0
In this mode one can only multiply as per Table 1. Programmable delay capability
and divider capability is deactivated. PLL is running.
Test mode
1
1
0
PLL and phase aligner both bypassed. REFCLK is directly channeled to output.
Hi-Z mode
0
1
X
Hi-Z
† X = don’t care, Hi-Z = high impedance
‡ Please see Table 4 and Table 5 for explanation for the programmability and phase alignment functions.
§ In this mode the DLYCTRL and LEADLAG terminals must be strapped high or low. Lowest possible jitter is achieved in this mode, but a delay
of 200 ps to 2 ns expected typically from REFCLK to CLKOUT depending on the output frequency.
Terminal Functions
TERMINAL
NAME
NO.
I/O
DESCRIPTION
CLKOUT
20
O
Output clock
CLKOUTB
18
O
Output clock (complement)
DLYCTRL
7
I
Every rising edge on this terminal delays/advances the CLKOUT/CLKOUTB signal by 1/384th of the
CLKOUT/CLKOUTB period. (e.g., for a 90 degree delay or advancement one needs to provide 96 rising
edges). See Table 4.
GND
5
GND for VDDREF and VDDPD
GNDO
17, 21
GNDP
4
GNDPA
8
LEADLAG
6
I
Decides if the output clock is delayed or advanced with respect to REFCLK. See Table 4.
MULT0/DIV0
15
I
PLL multiplier and divider select
MULT1/DIV1
14
I
PLL multiplier and divider select
NC
19
PWRDNB
12
I
Active low power down state, CLKOUT/CLKOUTB goes low
P0
24
I
Mode control, see the Function Table
P1
23
I
Mode control, see the Function Table
P2
13
I
Mode control, see the Function Table
REFCLK
2
I
Reference input clock
STOPB
11
I
Active low output disabler, PLL and PA still running, CLKOUT and CLKOUTB goes to a dc value as per Table 3
VDDPA
VDDPD
9
I
Supply voltage for phase aligner
10
I
Reference voltage for the DLYCTRL, LEADLAG terminals and STOPB function
1
I
Reference voltage for REFCLK
16, 22
I
Supply voltage for the output terminals (CLKOUT, CLKOUTB)
3
I
Supply voltage for PLL
VDDREF
VDDO
VDDP
GND for clock output terminals (CLKOUT, CLKOUTB)
GND for PLL
GND for phase aligner
Not used
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
PLL divider/multiplier selection
Table 1 and Table 2 list the supported REFCLK and BUSCLK (CLKOUT/CLKOUTB) frequencies.
Table 1. Multiplication Ratios (P0:2 = 000 or 100)
REFCLK
(MHZ)
MULTIPLICATION
RATIO
BUSCLK
(MHZ)
0
38−125
4
152−500
1
25−83.3
6
150−500
1
19−62.5
8
152−500
MULT0
MULT1
0
0
1
Table 2. Divider Ratio (P0:2 = 001)
MULT0
MULT1
REFCLK
(MHZ)
DIVISION
RATIO
BUSCLK(1)
(MHZ)
0
0
100−125
2
50−62.5
1
0
75−93
3
25−31
1
1
50−62
4
12.5−15.5
† BUSCLK will be undefined until a valid reference clock is available at REFCLK. After applying
REFCLK, the PLL requires stabilization time to achieve phase lock.
Table 3. Clock Output Driver States
STATE
PWRDNB
STOPB
CLKOUT
CLKOUTB
Powerdown
0
X
GND
GND
CLK stop
1
0
Normal
1
1
VO, STOP
As per Function Table
VO, STOP
As per Function Table
Table 4. Programmable Delay and Phase Alignment
DLYCTRL
LEADLAG
Each rising edge†
Each rising edge†
1
CLKOUT AND CLKOUTB
Will be advanced by one step size (see Table 5)
0
Will be delayed by one step size (see Table 5)
† For every 32nd edge, there are one or two edges the phase aligner does not update. Therefore,
CLKOUT phase is not updated on every 32nd edge.
Table 5. Clock Output Driver States
FUNCTIONALITY
STEP SIZE
Multiply by 4, 6, 8
CLKOUT period/384 (for example, 6.5 ps at 400 MHz)
Divide by 2
CLKOUT period/3072 (for example, 6.5 ps at 50 MHz)
Divide by 3
CLKOUT period/6144 (for example, 6.5 ps at 25 MHz)
Divide by 4
CLKOUT period/12288 (for example, 6.5 ps at 12.5 MHz)
NOTE: The frequency of the DLYCTRL terminal must always be equal or less than the
frequency of the LEADLAG terminal.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage range, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4 V
Output voltage range, VO, at any output terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VDD + 0.5 V
Input voltage range,VI, at any input terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VDD + 0.5 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see Dissipation Rating Table
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the GND terminals.
DISSIPATION RATING TABLE
PACKAGE
TA ≤ 25°C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C‡
TA = 85°C
POWER RATING
DBQ
1400 mW
11 mW/°C
740 mW
‡ This is the inverse of the junction-to-ambient thermal resistance when board-mounted and with
no air flow.
recommended operating conditions
Supply voltage, VDD (VDDP, VDDPA, VDDO)
MIN
NOM
MAX
3
3.3
3.6
0.7 × VDD
High-level input voltage, VIH (CMOS)
REFCLK low-level input voltage, VIL
0.7 × VDDREF
REFCLK high-level input voltage, VIH
Input signal high voltage, VIH (STOPB, DLYCTRL, LEADLAG)
0.7 × VDDPD
Input reference voltage for (REFCLK) (VDDREF)
1.235
Input reference voltage for (DLYCTRL and LEADLAG) (VDDPD)
1.235
V
V
V
High-level output current, IOH
Low-level output current, IOL
Operating free-air temperature, TA
V
V
0.3 × VDDPD
Input signal low voltage, VIL (STOPB, DLYCTRL, LEADLAG)
V
V
0.3 × VDD
0.3 × VDDREF
Low-level input voltage, VIL (CMOS)
UNIT
−40
VDD
VDD
V
−16
mA
16
mA
85
°C
V
timing requirements
MIN
Input frequency of modulation, fmod (if driven by SSC CLKIN)
MAX
33
Modulation index (nonlinear maximum 0.5%)
UNIT
kHz
0.6%
Input slew rate, SR
1
4
Input duty cycle on REFCLK
40%
60%
Input frequency on REFCLK
19
125
MHz
200
MHz
400
MHz
Allowable frequency on DLYCTRL
Allowable frequency on LEADLAG
Allowable duty cycle on DLYCTRL and LEADLAG
POST OFFICE BOX 655303
25%
• DALLAS, TEXAS 75265
V/ns
75%
5
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
TEST CONDITIONS†
PARAMETER
VO(STOP)
Output voltage during CLK stop
mode
See Figure 1
VOX
VO
Output crossing-point voltage
See Figure 1 and Figure 4
Output voltage swing (VOH − VOL)
See Figure 1
VIK
Input clamp voltage
VDD = 3 V,
II = −18 mA
See Figure 1, VDD = 3 to 3.6 V
VOH
High-level output voltage
VOL
Low-level output voltage
IOH
IOL
VDD = 3 V,
IOH = −16 mA
See Figure 1, VDD = 3 to 3.6 V
High-level output current
Low-level output current
VDD = 3 V,
VDD = 3.135 V,
IOL = 16 mA
VO = 1 V
VDD = 3.3 V,
VDD = 3.465 V,
VO = 1.65 V
VO = 3.135 V
VDD = 3.135 V,
VDD = 3.3 V,
VDD = 3.465 V,
VO = 1.95 V
VO = 1.65 V
High-impedance-state output
current
P0 = 0,
IOZ(STOP)
High-impedance-state output
current during CLK stop
Stop = 0, VO = GND or VDD
IOZ(PD)
High-impedance-state output
current in power-down state
PWRDNB = 0,
VO = GND or VDD
IIH
IIL
ZO
Low-level input
current
Output impedance
(single ended)
Reference current
TYP‡
MAX
2
V
0.5VDDO−0.2
1.7
0.5VDDO+0.2
2.9
V
−1.2
V
2.0
V
2.2
0.3
0.6
0.5
−32
−14.5
mA
−21
61.5
65
25.5
P1 = 1
−10
mA
36
± 10
µA
± 100
µA
100
µA
VDD = 3.6 V,
VI = VDD
10
PWRDNB,
P0:2, MULT/
DIV0:1
VDD = 3.6 V,
VI = VDD
10
REFCLK,
STOPB
VDD = 3.6 V,
VI = 0
−10
PWRDNB,
P0:2, MULT/
DIV0:1
VDD = 3.6 V,
VI = 0
−10
µA
µA
High state
RI at IO −14.5 mA to −16.5 mA
15
35
50
Low state
RI at IO 14.5 mA to 16.5 mA
11
17
35
VDDREF,
VDDPD
VDD = 3.6 V
Input capacitance
CO
Output capacitance
IDD(PD)
Supply current in power-down state
V
−52
−51
43
V
2.6
REFCLK,
STOPB
CI
UNIT
1.1
VO = 0.4 V
IOZ
High-level input
current
MIN
Ω
PWRDNB = 0
50
µA
PWRDNB = 1
0.5
mA
VI = VDD or GND
VO = VDD or GND
2
pF
3
pF
REFCLK = 0 MHz to 100 MHz,
PWDNB = 0,
STOPB = 1
150
µA
IDD(CLKSTOP) Supply current in CLK stop state
BUSCLK configured for 500 MHz
40
mA
IDD(NORMAL) Supply current in normal state
BUSCLK = 500 MHz
P0:2 = 000; load see Figure 1
70
mA
† VDD refers to any of the following; VDDPA, VDDPD, VDDREF, VDDO, and VDDP
‡ All typical values are at VDD = 3.3 V, TA = 25°C.
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
jitter specification over recommended operating free-air temperature range and VCC (unless
otherwise noted)
PARAMETER
t(jitter)
(Multiplication only mode. Phase alignment
and programmable delay features are not
selected (PA bypass). See Figure 2.)
TEST CONDITIONS
155 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
6
40
50
27
27
ps
200 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
5.5
36
36
36
23
23
ps
312 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
3
20
18
18
17
17
ps
400 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
2.3
17
12
12
15
15
ps
500 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
2.1
16
8
8
14
14
ps
155 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
9
70
50
50
50
ps
200 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
7
55
36
36
40
40
ps
312 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
4
35
18
18
30
30
ps
400 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
3.1
27
13
13
25
25
ps
t(jitter)
(Multiplication with phase alignment and
programmable delay features selected. See
Figure 2.)
MIN
TYP†
CLKOUT
MAX
UNIT
† All typical values are at VDD = 3.3 V, TA = 25°C.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
jitter specification over recommended operating free-air temperature range and VCC (unless
otherwise noted) (continued)
PARAMETER
t(jitter)
(Multiplication with phase alignment and
programmable delay features selected.
See Figure 2.)
CLKOUT
MAX
UNIT
500 MHz
ps
12.5 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
12
75
55
55
ps
15.5 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
8
50
38
38
ps
25 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
7.5
50
35
35
ps
31 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
5.5
30
23
23
ps
50 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
8
40
12
30
30
ps
62.5 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
5.5
28
9
24
24
ps
12.5 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
12.5
80
55
55
ps
15.5 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
8.5
55
38
38
ps
25 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
10
60
35
35
ps
31 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Cycle-to-cycle (+)
Cycle-to-cycle (−)
7
40
23
23
ps
MULT0:1 = 00
(Divider
ratio = 2)
MULT0:1 = 11
(Divider
ratio = 4)
MULT0:1 = 10
(Divider
ratio = 3)
8
TYP†
2.9
24
9
9
20
20
MULT0:1 = 10
(Divider
ratio = 3)
t(jitter)
(Divider mode with
phase alignment and
programmable delay
features selected. See
Figure 2.)
MIN
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Phase jitter (accumulated, 50 kHz to 80 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
MULT0:1 = 11
(Divider
ratio = 4)
t(jitter)
(Divider mode with
phase aligner not active:
DLYCTRL =LEADLAG =
0 or 1. See Figure 2.)
TEST CONDITIONS
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
jitter specification over recommended operating free-air temperature range and VCC (unless
otherwise noted) (continued)
PARAMETER
t(jitter)
(Divider mode with
phase alignment and
programmable delay
features selected. See
Figure 2.)
CLKOUT
TEST CONDITIONS
MIN
TYP†
MAX
UNIT
50 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
9
50
13
35
35
ps
62.5 MHz
Period RMS (1Σ jitter, full frequency band)
Period p-p
Phase jitter (accumulated, 12 kHz to 20 MHz)
Cycle-to-cycle (+)
Cycle-to-cycle (−)
6.5
30
10
26
26
ps
MULT0:1 = 00
(Divider
ratio = 2)
† All typical values are at VDD = 3.3 V, TA = 25°C.
switching characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
t(DC)
Output duty cycle
See Figure 3
tr, tf
Output rise and fall times (measured at 20%−80% of
output voltage)
See Figure 5 and Figure 1
MIN
TYP†
MAX
45%
55%
150
350
UNIT
ps
† All typical values are at VDD = 3.3 V, TA = 25°C.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
state transition latency specifications
PARAMETER
t(powerup)
t(VDDpowerup)
t(MULT)
t(CLKON)
Delay time, PWRDNB↑ to CLKOUT/
CLKOUTB output settled (excluding
t(DISTLOCK))
FROM
TO
Powerdown
Normal
TEST
CONDITIONS
MIN
TYP†
MAX
3
See Figure 6
ms
Delay time, PWRDNB↑ to internal PLL and
clock are on and settled
3
Delay time, power up to CLKOUT/CLKOUTB
output settled
3
VDD
Delay time, power up to internal PLL and
clock are on and settled
MULT0 and MULT1 change to CLKOUT/
CLKOUTB output resettled (excluding
t(DISTLOCK))
STOPB↑ to CLKOUT/CLKOUTB glitch-free
clock edges
UNIT
Normal
See Figure 6
ms
3
Normal
Normal
See Figure 7
1
ms
CLK Stop
Normal
See Figure 8
10
ns
CLK Stop
Normal
See Figure 8
20
cycles
t(CLKSETL)
STOPB↑ to CLKOUT/CLKOUTB output
settled to within 50 ps of the phase before
STOPB was disabled
t(CLKOFF)
STOPB↓ to CLKOUT/CLKOUTB output disabled
Normal
CLK
Stop
See Figure 8
5
ns
t(powerdown)
Delay time, PWRDNB↓ to the device in the
power-down mode
Normal
Power−
down
See Figure 6
1
ms
t(STOP)
Maximum time in CLKSTOP (STOPB = 0)
before reentering normal mode (STOPB = 1)
STOPB
Normal
See Figure 8
100
µs
t(ON)
Minimum time in normal mode (STOPB = 1)
before reentering CLKSTOP (STOPB = 0)
Normal
CLK
stop
See Figure 8
100
† All typical values are at VDD = 3.3 V, TA = 25°C.
PARAMETER MEASUREMENT INFORMATION
CLKOUT
50 Ω
VCM
50 Ω
10 pF
CLKOUTB
Figure 1. Test Load and Voltage Definitions (VO(STOP), VOX, VOH, VOL)
10
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
ms
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
PARAMETER MEASUREMENT INFORMATION
CLKOUTB
CLKOUT
tcycle,i
tcycle,i+1
Cycle-to-Cycle Jitter = | tcycle,i − tcycle,i+r| Over 1000 Consecutive Cycles
Figure 2. Cycle-to-Cycle Jitter
CLKOUT
CLKOUTB
tpw+
tcycle
Duty Cycle = (tpw+/tcycle)
Figure 3. Output Duty Cycle
CLKOUT
VX+
VX, nom
VX−
CLKOUTB
Figure 4. Crossing-Point Voltage
VOH
80%
20%
VOL
tr
tf
Figure 5. Voltage Waveforms
PWRDNB
CLKOUT/
CLKOUTB
ÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎ
Figure 6. PWRDNB Transition Timings
POST OFFICE BOX 655303
ÎÎ
ÎÎ
ÎÎ
t(power down)
t(power up)
• DALLAS, TEXAS 75265
11
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
PARAMETER MEASUREMENT INFORMATION
MULT0 and/or MULT1
ÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎ
CLKOUT/
CLKOUTB
t(MULT)
Figure 7. MULT Transition Timings
t(ON)
t(STOP)
STOPB
t(CLKSETL)
t(CLKON)
(see Note A)
CLKOUT/
CLKOUTB
ÎÎÎÎ
ÎÎÎÎ
ÎÎÎÎ
Output Clock
Not Specified
Glitches OK
Clock Enabled
and Glitch Free
ÎÎ
ÎÎ
ÎÎ
Clock Output Settled
Within 50 ps of the
Phase Before Disabled
NOTE A: Vref = VO ± 200 mV
Figure 8. STOPB Transition Timings
12
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
t(CLKOFF)
(see Note A)
SCAS813A − AUGUST 2005 − REVISED DECEMBER 2005
Z = 50 Ω ; Length = L1
CDCVF2310
Clock Buffer
3.3 V
CDC5801
VDDREF A
3.3 V
REFCLK
VDDP
GNDP
GND
3.3 V
CLK
Outputs are Phase Aligned
Between the Two Buffers
P0
P1
VDDO
GNDO
3.3 V
CDCVF2310
Clock Buffer
CLKOUT
LEADLAG
NC
DLYCTRL
CLKOUTB
Z = 50 Ω
20 R
GNDPA
GNDO
VDDPA
VDDPD
VDDO
MULT0/DIV0
3.3 V
STOPB
MULT1/DIV1
3.3 V
PWRDNB
CLK
155.52 MHz
Z = 50 Ω
Z = 50 Ω
19.44 MHz
Very Low Jitter
19.44 MHz
P2
Z = 50 Ω ; Length = L1
Figure 9. Using the CDC5801A Device as a Multiplier by 8 and Aligning Two Different Clocks
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
13
PACKAGE MATERIALS INFORMATION
www.ti.com
16-Aug-2012
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
CDC5801ADBQR
Package Package Pins
Type Drawing
SSOP
DBQ
24
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
2500
330.0
16.4
Pack Materials-Page 1
6.5
B0
(mm)
K0
(mm)
P1
(mm)
9.0
2.1
8.0
W
Pin1
(mm) Quadrant
16.0
Q1
PACKAGE MATERIALS INFORMATION
www.ti.com
16-Aug-2012
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
CDC5801ADBQR
SSOP
DBQ
24
2500
367.0
367.0
38.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46C and to discontinue any product or service per JESD48B. Buyers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All
semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time
of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Mobile Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2012, Texas Instruments Incorporated
Similar pages