IVO N214.311AX01 Totalizers electronic Datasheet

Totalizers electronic
Large impulse counters and position displays
Display LED, 6-digits, programmable
N 214
Features
–– Totalizer and position display
–– Display 6-digits
–– Set value, scaling factor, momentary signal duration
and operating mode programmable
–– Connection: Incremental encoder or digital sensors
–– Interface RS232, RS422, RS485
Technical data - electrical ratings
Voltage supply
115/230 VAC ±10 % (50/60 Hz)
24/48 VAC ±10 % (50/60 Hz)
12...30 VDC
Programmable
parameters
Decimal point
Sensor logic, scaling factor
Count mode, measuring units
Power consumption
7 VA, 5 W
Approvals
UL/cUL, CE conform
Sensor supply
12...26 VDC / max. 100 mA
Display
LED, 7-segment display
Technical data - mechanical design
Number of digits
6-digits
Digit height
14 mm
Operating temperature
0...+50 °C
Function
Totalizer
Difference counter A - B
Parallel counter A + B
Position display
Storing temperature
-20...+70 °C
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals
Core cross-section
1.5 mm²
0.0001...9999.99
Protection DIN EN 60529
IP 65 face with seal
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L
96 x 48 x 124 mm
Installation depth
124 mm
3 Hz, 25 Hz, 10 kHz
programmable
Mounting
Clip frame
Measuring range
-99 999...+999 999
Cutout dimensions
92 x 45 mm (+0.6)
Data memory
>10 years in EEPROM
Materials
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Reset
Button and electric
Weight approx.
350 g (AC), 250 g (DC)
Keylock
Yes, electric (keylock)
Outputs electronic
Optocoupler
Outputs relay
Potential-free change-over
contact
Output holding time
0.01...9.99 s
Interfaces
RS232, RS422, RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
Scaling factor
Count modes
Counting frequency
1
www.baumerivo.com
30/10/2008
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
N 214 - Totalizer
Totalizers electronic
Large impulse counters and position displays
Display LED, 6-digits, programmable
N 214
Part number
Block circuit diagram
N 214.
AX01
Voltage
supply
Voltage supply
1 24 / 48 VAC
2 115 / 230 VAC
3 24 VDC
2
4
+
3
5
Signal input
A
B
Outputs
0 Without relay
1 Relay and optocoupler outputs
0
1
2
3
-
10
A 90° B
Totalizer with
start count
scaling factor
7
8
Stop/Hold
9
SC- / 0
11
Output
20
21
14
SC- / 0
22
Interface
RS485
T,R+ 15
Interface
Without interface
RS485
RS422
RS232
+
Output
6
Reset
T,R-
Sensor
supply
-
TxD+ 16
TxD- 17
Interface
RS422
RxD+ 18
RxD- 19
TxD
16
RxD
18
Interface
RS232
GND 19
Connection diagram
TxD
Count
5
4
0V
6
+24V
Track B
7
Track A
Stop
8
Reset
SC- / 0
Output
T,R-
T,R+
RS485
9
3
2
1
Supply voltage
RS232
15 14 13 12 11 10
Sensor
supply
Input circuit
PNP- / NPN-logic
Input level
Programmable
Input level Low
0...2 VDC
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay output
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Electronic output
Output circuit
Optocoupler not short-circuit proof
Switching voltage max.
40 V
Switching current max.
15 mA
Dimensions
96
7
48
123.75
109
19.75
1-10
2
www.baumerivo.com
30/10/2008
TxDTxD+
RxD+
RxD-
RS422
RxD
max. 250V
terminal - terminal /
- terminal
GND
SC- / 0
Output
Comparator inputs
Inputs
Subject to modification in technic and design. Errors and omissions excepted.
Trigger level
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Similar pages