ACDC 65/100/130 Watts ECS Series xppower.com • IT & Medical Safety Approvals • 65/80/100 W Convectioncooled Ratings • Class I & Class II Construction • Industry Standard 2” x 4” Package • <0.5 W No Load Input Power • Low Leakage Current • 3 Year Warranty Specification Input General • 80-264 VAC (275 VAC ECS65) (120-370 VDC), derate output power <90 VAC, see derating curves Input Frequency • 47-400 Hz(1) Input Current • 65 W: 1.0/0.6 A typical at 115/230 VAC 100 W: 1.5/0.9 A typical at 115/230 VAC, 130 W: 1.9/1.1 A typical at 115/230 VAC full load Inrush Current • 40 A max at 230 VAC, cold start at 25 ˚C Power Factor • EN61000-3-2, class A No Load Input Power • <0.5 W Earth Leakage Current • 65/130 W: 260 µA at 264 VAC/60 Hz max 100 W: 230 µA at 264 VAC/60 Hz max Input Protection • Internal T3.15/T5 A/250 V fuse in line and neutral Input Voltage Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Drift Line Regulation Load Regulation Over/Undershoot Transient Response • • • • • • • • • • • • Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient • • • • • 12-48 VDC (see tables) ±10% ±1% No minimum load required 1 s typical 50 ms 16 ms min at 115 VAC ±0.2% after 20 min warm up ±0.5% max ±1% 5% typical 4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change 1% pk-pk, 20 MHz bandwidth 115-140% Vnom, recycle input to reset 110-160% Continuous trip and restart (hiccup mode) 0.05%/˚C Notes 1. Safety approvals cover frequency 47-63 Hz. Efficiency Isolation Switching Frequency Power Density MTBF • Up to 90% model dependent • 4000 VAC Input to Output, 2 x MOPP, 1500 VAC Input to Ground, 1 x MOPP, 500 VDC Output to Ground, 1 x MOPP • 65 KHz typical • 65 W: 7.7 W/in3, 100 W: 10 W/in3, 130 W: 13 W/in3 • 65 W: 850 kHrs, 100 W: 834 kHrs, 130 W: 715 kHrs to MIL-HDBK-217F at 25 ˚C, GB Environmental Operating Temperature • -20 ˚C (-40 ˚C, ECS130) to +70 ˚C derate linearly from +50 ˚C at 2.5%/˚C to 50% load at +70 ˚C. Cooling • Convection & fan cooled ratings (see tables) Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes EMC & Safety Low Voltage PSU EMC • EN61204-3, high severity level Emissions • EN55011/22 level B conducted EN55011/22 level A radiated, level B Suffix ‘-B’ models Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, installation class 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation. Safety Approvals • IEC60950-1 CB report, CSA 22.2 No. 60950-1, UL60950-1, TUV EN60950-1 IEC60601-1 CB report, CSA 22.2 No. 60601-1, ANSI/AMMI ES60601-1, TUV 60601-1, including risk management Equipment Protection • Class I & II (ECS65 Non ‘-B’ models, Class Class I only) Output Power 65 65 65 65 65 65 Output Voltage W W W W W W 12.0 15.0 18.5 24.0 28.0 48.0 Output Current VDC VDC VDC VDC VDC VDC 5.4 4.3 3.4 2.7 2.3 1.4 Model Number(1) A A A A A A ECS65US12 ECS65US15 ECS65US18 ECS65US24 ECS65US28 ECS65US48 Notes 1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER KIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations. Mechanical Details 4.00 (101.6) 1.05 (26.7) 3.750 (95.25) 0.125 (3.17) C4 1 2.00 (50.8) 1.75 (44.45) C5 J1 2 1 T1 1 0.95 (24.1) 4 0.25 Faston Ground Tab 0.125 (3.18) Q1 J2 0.96 (24.5) 0.20 (5.1) 4 X ø.156 (3.96) Mounting Holes ø.312 (7.92) Clearance top and bottom 0.20 (5.1) Input Connector J1 Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth 0.14 (3.5) SMD Component Height Output Connector J2 Molex PN 09-65-2048 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp Terminals Notes 1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 2. Weight: 0.386 lbs (175 g) Derating Curve ECS65 Models 100 100 90 90 80 80 Output Power (%) 70 60 50 40 Open Frame With Cover 70 60 50 40 80 85 275 90 Input Voltage (VAC) -20 30 -40 Output Power (%) Some Specification Parameters may not be met 40 50 Ambient Temperature (ºC) 60 70 ACDC ECS65 Models and Ratings Output Power Forced Cooled (10 CFM) Convection-cooled 100 W 80 W 100 W 80 W 100 W 80 W 100 W 80 W 100 W 80 W 100 W 80 W Output Voltage 12.0 15.0 18.0 24.0 28.0 48.0 Output Current VDC VDC VDC VDC VDC VDC 8.3 6.7 5.5 4.2 3.6 2.1 Model Number(1) A A A A A A ECS100US12 ECS100US15 ECS100US18 ECS100US24 ECS100US28 ECS100US48 Notes 1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER KIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations. ‘-C’ not available for ‘-B’ models. Mechanical Details 1.25 (31.8) 4.00 (101.6) 3.750 (95.25) 0.125 (3.18) C4 1.750 (44.45) 2.00 (50.8) Voltage Adj. J1 C5 T1 J2 1.01 (25.7) 1.00 (25.4) Q1 0.25 Faston Ground Tab 0.125 (3.18) 0.20 (5.1) 0.14 (3.5) SMD Component Height 4 X ø.156 (3.96) Mounting Holes ø.312 (7.92) Clearance top and bottom 0.20 (5.1) ‘ B’ Model 1.25 (31.8) 4.50 (114.3) 0.37 (9.52) 2.00 (50.8) Output Connector J2 Molex PN 09-65-2048 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN Input Connector J1 Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp Terminals 3.75 (95.25) 1.75 J1 (44.45) Notes J2 0.20 (5.1) 1.00 (25.4) 1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 2. Weight: 0.386 lbs (175 g) 1.01 (25.7) 0.20 (5.1) 0.125 (3.18) 4 X ø.156 (3.96) Mounting Holes ø.312 (7.92) Clearance top and bottom 0.14 (3.5) SMD Component Height 0.10 (2.5) 0.25 Faston Ground Tab Derating Curve ECS100 Models 100 100 90 90 80 80 Output Power (W) Output Power (%) ACDC ECS100 Models and Ratings 70 60 50 40 70 60 Force-cooled >10 CFM Convection-cooled Convection-cooled with cover 50 40 30 80 85 264 90 Input Voltage (VAC) -20 +40 +50 Ambient Temperature (ºC) +60 +70 Output Power Forced Cooled (10 CFM) Convection-cooled 130 W 100 W 130 W 100 W 130 W 100 W 130 W 100 W 130 W 100 W 130 W 100 W Output Voltage 12.0 15.0 18.0 24.0 28.0 48.0 Output Current VDC VDC VDC VDC VDC VDC 10.9 8.7 7.3 5.4 4.7 2.7 Model Number(1) A A A A A A ECS130US12 ECS130US15 ECS130US18 ECS130US24 ECS130US28 ECS130US48 Notes 1. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER KIT for standalone cover, see derating curve. The cover is not suitable for Class II installations. ‘-C’. Mechanical Details 4.00 (101.6) 0.125 (3.17) 1.28 (32.5) 3.750 (95.25) Voltage Adjust C4 2.00 (50.8) 1.75 (44.45) N J1 L 2 1 1 T1 J2 C5 1.00 (25.4) 4 0.12 (3.18) 0.20 (5.1) Q1 0.20 (5.1) 1.05 (26.7) 0.15 (3.8) SMD COMPONENT HEIGHT .25 FASTON GROUND TAB 4X .156 (3.96) MOUNTING HOLES .312 (7.92) CLEARANCE TOP AND BOTTOM Output Connector J2 Molex PN 09-65-2048 Pin 1 +V1 Pin 2 +V1 Pin 3 RTN Pin 4 RTN Notes Input Connector J1 Molex PN 09-65-2038 Pin 1 Line Pin 2 Neutral 0.25” Faston Earth 1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 2. Weight: 0.386 lbs (175 g) J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp Terminals Derating Curve ECS130 Models 130 130 120 Forced-cooled >10 CFM 110 110 100 90 Convection-cooled 80 Output Power (W) Output Power (W) 100 70 60 Convection-cooled with cover 50 90 80 70 60 50 40 40 30 30 20 20 10 10 80 90 100 Input Voltage (VAC) 264 -40 Forced-cooled >10 CFM Some specification parame ters may not be met 120 Convection-cooled Convection-cooled with cover -20 0 Ambient Temperature (ºC) 50 60 70 ACDC ECS130 Models and Ratings ACDC ECS65/100/130 Mechanical Details Covered Version (not available for ECS100B Models) 4.49 (114.0) 2.52 (64.0) Input Connector Output Connector 0.25 (0.6) Ground Faston Terminal 0.807 (20.50) 1.54 (39.0) 2 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration 4.055 (103.00) 0.22 (5.5) 4.055 (103.00) 0.22 (5.5) 0.79 (20.0) 0.984 (25.00) 4 x M3 x 0.5 THD 0.16 (4.0) Max Screw Penetration Notes 1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 2. Weight: 0.8 lbs (360 g) Thermal Considerations All Models In order to ensure safe and reliable operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. See mechanical drawing for component locations. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). Component Temperature Measurements (Ambient ≤ 50 °C) Max Temperature °C T1 110 °C C5 100 °C C4 100 °C Q1 110 °C 30-May-14