Power-One MAP55-1024 Wide range input for 110/220 vac application Datasheet

MAP55 SERIES
Other mechanical design innovations include metric and SAE
mounting inserts on each mounting surface to provide integration
flexibility. Dual-mode connectors provide traditional terminal block
connections or popular single row Molex connector mating.
Power-One's MAP55 series of power supplies provides reliable, tightly
regulated DC power for commercial and industrial systems. Widerange AC input and full international safety, EMI, and ESD
compliance ensure world-wide acceptance. All units bear the CE
Mark.
Single output models feature wide-range output adjustability to meet a
wide variety of standard and user specific output voltage requirements.
The MAP55 utilizes a thermally efficient U-channel chassis design,
which allows full power operation in convection cooled applications.
FEATURES
• Wide Range Input for 110/220 VAC Applications
• Meets EN55022, Conducted Class B Limits
• Compact Footprint: 6.00" x 3.27" x 1.60"
(152.4mm x 83.1mm x 40.6mm)
• Greater than 225,000 Hours MTBF
• Metric and SAE Mounting Inserts
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
MAP40-1005
MAP55-1012
MAP55-1024
NOTES:
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 3)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
5V
12V/15V
24V/28V
4.7V to 5.50V
11.4V to 15.75V
23.5V to 28.5V
8A
5.0/4.0A (Note 2)
2.5/2.2A (Note 2)
11A
5.8/4.7A (Note 2)
2.9/2.5A (Note 2)
0.2%
0.2%
0.2%
±1.5%
±1%
1%
1%
1%
1%
5.0V to 5.2V
12.0V to 12.2V
23.8V to 24.2V
1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
MULTIPLE OUTPUT MODEL SELECTION CHART – 55W CONTINUOUS OUTPUT POWER
MODEL
MAP55-4000
MAP55-4001
MAP55-4002
MAP55-4003
MAP55-4004
NOTES:
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
+5V
+12V
-5V
-12V
+5V
+24V
-12V
+12V
+5V
+12V
-12V
+12V
+5V
+15V
-5V
-15V
+5V
+24V
-15V
+15V
4.7V to 5.6V
Fixed
Fixed
Fixed
4.7V to 5.6V
Fixed
Fixed
Fixed
4.7V to 5.6V
Fixed
Fixed
Fixed
4.7V to 5.6V
Fixed
Fixed
Fixed
4.7V to 5.6V
Fixed
Fixed
Fixed
6A
3A
0.5A
0.5A
6A
1.5A
0.5A
0.5A
6A
3A
0.5A
0.5A
6A
2.5A
0.5A
0.5A
6A
1.5A
0.5A
0.5A
8A
5A
1A (Note 3)
1A (Note 3)
8A
2.5A
1A (Note 3)
1A (Note 3)
8A
5A
1A (Note 3)
1A (Note 3)
8A
3.5A
1A (Note 3)
1A (Note 3)
8A
2.5A
1A (Note 3)
1A (Note 3)
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.0V to 5.2V
11.6V to 12.4V
-4.8V to -5.2V
-11.6V to -12.4V
5.0V to 5.2V
23.0V to 24.9V
-11.6V to -12.4V
11.6V to 12.4V
5.0V to 5.2V
11.6V to 12.4V
-11.6V to -12.4V
11.6V to 12.4V
5.0V to 5.2V
14.6V to 15.4V
-4.8V to -5.2V
-14.4V to -15.6V
5.0V to 5.2V
23.0V to 24.9V
-14.5V to -15.5V
14.5V to 15.5V
1) Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded.
REV. 09/01
1
MAP55 SERIES
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage - AC
Continuous input range.
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (55W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
90
175
47
90
20
Operating Frequency
Switching frequency of power supply (varies with load).
NOM
MAX
UNITS
132
264
63
VAC
1.6
22
Hz
VAC
ms
ARMS
38
APK
180
kHz
MAX
UNITS
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Efficiency
Minimum Loads
Full load, 115VAC. Varies with distribution of loads among outputs.
73
MAP55-1012
0.21
MAP55-1024
0.11
MAP40-1005 and all multiple output models, main channel only.
0.50
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on, V1, V2.
Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC,
changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output units).
Time required for initial output voltage stabilization.
1
Time required for output voltage to rise from 10% to 90% (Note 1).
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
NOTES:
MIN
NOM
%
Amps
See Model Selection Chart.
55
Watts
65
Watts
1
%
See Model Selection Chart.
500
µs
4
Sec
ms
MAX
UNITS
7
1) Nominal rise time for MAP55-1024 is 36 msec.
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
Overvoltage Protection
MAP40-1005
5.5
6.8
MAP55-1012
17.5
19.7
MAP55-1024
32.0
36.0
Main output only of multiple output units.
5.6
6.8
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Overload Protection
MIN
NOM
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
Dielectric Withstand
Voltage
Electromagnetic
Interference,
Conducted
Insulation Resistance
Leakage Current
MIN
NOM
MAX
UNITS
Approved.
2600
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Input to output.
Per EN60950, 264VAC.
2
VDC
B
B
A
7
Class
500
MΩ
µA
MAP55 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-operating.
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C.
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
MIN
At 100% load:
At 50% load:
NOM
0
0
-40
0°C to 70°C (after 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10 Hz to 2 kHz, 3 axis.
±0.02
5
MAX
UNITS
10k
40k
50
70
85
±0.03
95
20
6
Feet
°C
°C
°C
%/°C
%RH
G
GRMS
OPTIONS
DESCRIPTION
NOTES
Cover
Add ‘C’ suffix to model number or order part number 412-59584 separately.
For convection cooled applications, derate output power to 45 watts on multiple
output units, 50 watts on MAP55-1012 and MAP55-1024,and 40 watts on MAP40-1005.
DIMENSIONS
6.00" x 3.27" x 1.85"
(152.4mm x 83.1mm x 47.0mm)
OVERALL SIZE: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm)
WEIGHT: 1.1 LBS (0.55 kg)
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm)
SQUARE PINS ON 0.156" (3.4mm) CENTERS, MATES WITH MOLEX SERIES 2139, 6442, OR 41695
CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH
3
Similar pages