FA03216 Fiber Optic LC Test Cable Assembly LENGTH (INCH) END A (LC CONNECTOR) END B FA03216 - 01 - XXXX - 50 Basic Number End B Terminus Type Length (in) 01= GA SKT TERMINUS, M29504/05 STYLE (181-001) Example 0072 = 72" 02= GA PIN TERMINUS, M29504/04 STYLE (181-002) 03= GA PIN TERMINUS, GHD (181-047) 04= GA PIN TERMINUS, GHD, PC ONLY (181-056) 05= GA PIN TERMINUS, M29504/14 STYLE (181-039) 06= GA SKT TERMINUS, M29504/15 STYLE (181-040) 07= GA PIN TERMINUS, D38999 SERIES III STYLE, SIZE 20 (181-065) 08= GA SKT TERMINUS, D38999 SERIES III STYLE, SIZE 20 (181-066) 09= GA PIN TERMINUS, GFR (181-012) 10= GA SKT TERMINUS, GFR (181-011) 11= GA PIN TERMINUS, ARINC 801 (181-076-N) 12= GA PIN TERMINUS, GFOCA (181-050) WITHOUT CERAMIC SLEEVE 13= GA PIN TERMINUS, MIGHTY MOUSE SIZE 20HD (181-084) 14= GA SKT TERMINUS, MIGHTY MOUSE SIZE 20HD (181-085) 15= GA PIN TERMINUS, MIGHTY MOUSE SIZE 16 (181-057) 16= GA SKT TERMINUS, MIGHTY MOUSE SIZE 16 (181-075) 17= GA PIN TERMINUS, GFOCA (181-050) WITH CERAMIC SLEEVE P/N: (181-050-S) 18= GC CONNECTOR (187-258) Fiber Size (microns) 09 = SM 9.3/125 Jacketed 50 = MM 50/125 Jacketed 62 = MM 62.5/125 Jacketed Standard Tolerance Length 3 to 12 in 12 in – 2 ft 2 to 10 ft 10 to 50 ft 50 to 100 ft 100 ft and up Tolerance +0.25 in -0 +1 in -0 +3 in -0 +6 in -0 +1 ft -0 +2 ft -0 Notes 1. Optical performance: insertion loss to be less than 1.5 dB when measured at 850 nm wavelength for Multimode and 1310 nm wavelength for Singlemode. © 2014 Glenair, Inc. U.S. CAGE Code 06324 Printed in U.S.A. GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912 www.glenair.com E-Mail: [email protected]