BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters FEATURES · 25 mbar to 10 bar, 0.3 to 150 psi differential pressure · 1...6 V or 4...20 mA output12 · Precision temperature compensated and calibrated · Rugged aluminium housing · Female 1/8" BSP and 1/8" NPT fittings MEDIA COMPATIBILITY Pressure inlet: Non-corrosive, non-ionic media such as air, dry gases and the like Housing: Aluminium, protection class IP 67 (according to DIN EN 60529, NEMA 6)1 SPECIFICATIONS10,11 ELECTRICAL CONNECTION Maximum ratings 1...6 V output version Supply voltage 12...32 V Output current BTE(M)/PTE/PTU5...D1... Source Sink 20 mA 10 mA Output current BTE(M)/PTE/PTU5...D4... 30 mA Temperature limits Storage Operating Compensated Pressure at any port BTEM5x025... / PTx5000.3... all others Vout 2 -Vs 4 case 3 3.5 bar / 50 psi 12 bar / 175 psi 12 to 32 V GND V 4...20 mA output version +Vs 1 Sensor 12 to 32 V V -Vs 3 E / 11101 / B Sensor -40...85 °C -25...85 °C 0...70°C Proof pressure2 BTEM5x025... / PTx5000.3... 0.35 bar / 5 psi BTEM5x070..., BTEM5x350... / 1.4 bar / 20 psi PTx5001..., PTx5005... all others 2 x rated pressure 1 +Vs 4 RL GND case 3 1/5 www.first-sensor.com www.sensortechnics.com BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters COMMON PERFORMANCE CHARACTERISTICS8 Characteristics Thermal effects (0 to 70°C)6 Offset Min. all ≤ 70 mbar / 1 psid devices all 350 mbar / 5 psid devices all others Span Non-linearity and hysteresis4 5 Typ. Max. Unit ±0.025 ±0.008 ±0.005 ±0.001 ±0.125 ±0.040 ±0.025 ±0.045 %FSO/°C ±0.2 ±1 Long term stability ±0.2 Output noise (0 ≤ f ≤ 1 kHz) 0.04 Response time (10 to 90 %) 1 %FSO ms INDIVIDUAL PERFORMANCE CHARACTERISTICS8 1...6 V output versions (VS = 15 V, tamb = 25°C, RL > 100 kΩ, com. mode pressure = 0) Characteristics Zero pressure offset BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others Full scale span7 Min. Typ. Max. 3.4 0.9 2.4 4.9 3.5 1.0 2.5 5.0 6.0 3.6 1.1 2.6 5.1 Full scale output Power supply rejection Offset Span 0.05 0.03 Output impedance V %FSO/V 50 Power consumption Unit 60 Ω mW 4...20 mA output versions (VS = 15 V, tamb = 25°C, RL = 100 Ω, com. mode pressure = 0) Characteristics Zero pressure offset Full scale span7 BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others Full scale output Power supply rejection Offset Span Min. Typ. Max. 11.9 3.9 7.9 15.9 12.0 4.0 8.0 16.0 20.0 12.1 4.1 8.1 16.1 0.05 0.03 Output impedance Power consumption (IL = 20 mA) E / 11101 / B mA %FSO/V 0.1 260 Unit Ω mW 2/5 www.first-sensor.com www.sensortechnics.com BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters LOAD LIMITATION 4...20 mA output versions 1200 Ohm 1000 800 600 operating range 400 200 0 10 20 30 V Vsupply ELECTROMAGNETIC CAPABILITY9 Test conditions Radiated, radio frequency EN61000-4-3: 10 V/m, 80 to 1000 MHz electromagnetic field immunity (RFI) 80 % AMC (1 kHz) Electrical fast transient / EN61000-4-4: ±2 kV burst immunity (EFT) Electrostatic discharge immunity EN61000-4-2: ±4 kV, contact discharge test (ESD) ±8 kV, air discharge Immunity to conducted disturbances EN61000-4-6: 0.15 to 80 MHz induced by radio-frequency fields 10 V, 80 % AMC (1 kHz) Criterion Interference A <1 %FSO B <1 %FSO B <1 %FSO A <1 %FSO Specification notes: 1. IP 67 protection for BTE(M)5...A / PTx5...A is given with locked connector only. 2. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 3. This is the highest pressure which can be applied to any port at any time. At the same time the differential pressure between the ports H and L must not exceed the maximum proof pressure. 4. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 5. Long term stability is the change in output after one year or 1 million pressure cycles. 6. Thermal effects tested and guaranteed from 0 - 70 °C relative to 25°. All specifications shown are relative to 25°C. 7. Full scale span is the algebraic difference between the positive full scale output and zero pressure offset. 8. Higher pressure applied to port H. 9. Test are in accordance with EN 61000-6-2. 10. CE-labelling is in accordance with 2004/108/EC. 11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 12. 0...10 V square rooting output signal on special request. E / 11101 / B 3/5 www.first-sensor.com www.sensortechnics.com BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters OUTLINE DRAWING Connector version 40.0 (1.58) NOM 86.0 (3.39) 20.0 (0.79) 13.5 diam. (0.53) 72.0 (2.84) H: high pressure port L: low pressure port mating plug 8.0 (0.31) min. 4 M12 x 1 (0.47) 9.0 (0.35) BTE.../PTE...: 2 x 1/8" BSP PTU...: 2 x 1/8" NPT 3 2 8.0 (0.31) min. 2 x M5 (UNC 10-24) 1 ELECTRICAL CONNECTION mass: typ. 170 g Pin 1 2 3 4 Connection 1-6V 4 - 20 mA output output +Vs +Vs Vout NC case case -Vs -Vs dimensions in mm (inches) Cable version 40.0 (1.58) 90.0 (3.54) H: high pressure port L: low pressure port 72.0 (2.84) 20.0 (0.79) 13.5 diam. (0.53) 1 m (3.3 ft) shielded cable 4 x 0.25 mm² (AWG24) 8.0 (0.31) min. 8.0 (0.31) min. 2 x M5 (UNC 10-24) 9.0 (0.35) BTE.../PTE...: 2 x 1/8" BSP PTU...: 2 x 1/8" NPT ELECTRICAL CONNECTION mass: typ. 220 g bare brown white green yellow E / 11101 / B Connection 1-6V 4 - 20 mA output output case/shield case/shield +Vs +Vs NC NC Vout NC -Vs -Vs dimensions in mm (inches) 4/5 www.first-sensor.com www.sensortechnics.com BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters RECOMMENDED CABLE/CONNECTOR ACCESSORY for connector version Order number ZK000101, other cable length on special request NOM 2 m 36.5 PIN CONNECTION Pin 1 2 3 4 NOM 60 Flying lead end brown green white + shield yellow Included in delivery! M12 x 1 Ø 20 ORDERING INFORMATION BT/PT x (M) 5xxx D x x Calibration BT: calibration in mbar/bar PT: calibration in psi Electrical connection A: connector version C: cable version Pressure connection E: 1/8" BSP female U: 1/8" NPT female Output signal 1: 1...6 V 4: 4...20 mA For mbar ranges only Differential pressure Pressure range BTE5000 series 0025: 0...25 mbar P025: -25...+25 mbar 0070: 0...70 mbar P070: -70...+70 mbar 0350: 0...350 mbar P350: -350...+350 mbar 001: 0...1 bar P01: -1...+1 bar 002: 0...2 bar 005: 0...5 bar 010: 0...10 bar PTE/PTU5000 series 000.3: 0...0.3 psi 001: 0...1 psi P01: -1...+1 psi 005: 0...5 psi P05: -5...+5 psi 015: 0...15 psi P15: -15...+15 psi 030: 0...30 psi 100: 0...100 psi 150: 0...150 psi Other pressure ranges and options are widely available. Please contact First Sensor. First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. E / 11101 / B 5/5 www.first-sensor.com www.sensortechnics.com