LINER LTC2977 8-channel pmbus power system manager featuring accurate output voltage measurement Datasheet

LTC2977
8-Channel PMBus Power
System Manager Featuring Accurate
Output Voltage Measurement
Description
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Sequence, Trim, Margin and Supervise Eight Power
Supplies
Manage Faults, Monitor Telemetry and Create Fault Logs
PMBus Compliant Command Set
Supported by LTpowerPlay™ GUI
Margin or Trim Supplies to 0.25% Accuracy
Fast OV/UV Supervisors Per Channel
Coordinate Sequencing and Fault Management
Across Multiple Chips
Automatic Fault Logging to Internal EEPROM
Operate Autonomously without Additional Software
Internal Temperature and Input Voltage Supervisors
Accurate Monitoring of Eight Output Voltages, Input
Voltage and Internal Die Temperature
I2C/SMBus Serial Interface
Can Be Powered from 3.3V, or 4.5V to 15V
Programmable Watchdog Timer
100% Pin-Compatible Upgrade to the LTC2978/LTC2978A
Available in 64-pin 9mm × 9mm QFN Package
The LTC®2977 is an 8-channel Power System Manager
used to sequence, trim (servo), margin, supervise, manage faults, provide telemetry and create fault logs. PMBus
commands support power supply sequencing, precision
point-of-load voltage adjustment and margining. DACs use
a proprietary soft-connect algorithm to minimize supply
disturbances. Supervisory functions include overvoltage
and undervoltage threshold limits for eight power supply
output channels and one power supply input channel, as
well as over and under temperature limits. Programmable
fault responses can disable the power supplies with optional
retry after a fault is detected. Faults that disable a power
supply can automatically trigger black box EEPROM storage
of fault status and associated telemetry. An internal 16-bit
ADC monitors eight output voltages, one input voltage,
and die temperature. In addition, odd numbered channels
can be configured to measure the voltage across a current
sense resistor. A programmable watchdog timer monitors microprocessor activity for a stalled condition and
resets the microprocessor if necessary. A single wire bus
synchronizes power supplies across multiple LTC power
system management devices. Configuration EEPROM supports autonomous operation without additional software.
Applications
n
n
n
n
n
Computers and Network Servers
Industrial Test and Measurement
High Reliability Systems
Medical Imaging
Video
L, LT, LTC, LTM, PolyPhase, Linear Technology and the Linear logo are registered trademarks
and LTpowerPlay is a trademark of Linear Technology Corporation. All other trademarks are the
property of their respective owners. Protected by U.S. Patents including 7382303, 7420359 and
7940091.
Typical Application
8-Channel PMBus Power System Manager
Typical ADC Total Unadjusted
Error vs Temperature
VIN
4.5V < VIBUS < 15V**
VIN_SNS
3.3V**
VDD33
VDACP0
TO INTERMEDIATE
BUS CONVERTER ENABLE
VIN_EN
SDA
PMBus
INTERFACE
WRITE-PROTECT
TO/FROM OTHER
LTC POWER SUPPLY MANAGERS
VSENSEP0
LTC2977*
SCL
R30
R20
R10
ALERTB
VSENSEM0
SGND
CONTROL0
VOUT_EN0
RUN/SS
GND
WP
FAULTB00
PWRGD
WDI/RESETB
ASEL0
SHARE_CLK
GND
ASEL1
2977 TA01a
TO µP RESETB INPUT
0.20
DIGITALLY
MANAGED
POWER
SUPPLY
VFB
LOAD
VDACM0
0.25
VOUT
WATCHDOG
TIMER INTERRUPT
*SOME DETAILS OMITTED FOR CLARITY
ONLY ONE OF EIGHT CHANNELS SHOWN
**MAY BE POWERED FROM EITHER AN
EXTERNAL 3.3V SUPPLY OR THE INTERMEDIATE BUS
VSENSEP0 = 1.8V
THREE TYPICAL PARTS
0.15
0.10
ERROR (%)
VPWR
0.05
0
–0.05
–0.10
–0.15
–0.20
–0.25
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
90
110
2977 TA01b
2977f
For more information www.linear.com/LTC2977
1
LTC2977
Table of Contents
Features.......................................................... 1
Applications..................................................... 1
Typical Application............................................. 1
Description...................................................... 1
Absolute Maximum Ratings................................... 4
Order Information............................................... 4
Pin Configuration............................................... 4
Electrical Characteristics...................................... 5
PMBus Timing Diagram........................................ 9
Typical Performance Characteristics...................... 10
Pin Functions.................................................. 13
Block Diagram................................................. 15
Operation...................................................... 16
Operation Overview......................................................16
EEPROM..................................................................17
Reset............................................................................17
Write-Protect Pin..........................................................17
Other Operations..........................................................17
Clock Sharing...........................................................17
PMBus Serial Digital Interface......................................18
PMBus.....................................................................18
Device Address........................................................21
Processing Commands............................................22
PMBus Command Summary................................ 23
Summary Table........................................................23
Data Formats...........................................................27
PMBus Command Description.............................. 28
Addressing and Write Protect......................................28
PAGE........................................................................28
WRITE_PROTECT....................................................28
MFR_PAGE_FF_MASK.............................................29
MFR_I2C_BASE_ADDRESS.....................................29
MFR_COMMAND_PLUS, MFR_DATA_PLUS0,
MFR_DATA_PLUS1, MFR_STATUS_PLUS0, and
MFR_STATUS_PLUS1.............................................30
Reading Fault Log Using Command Plus and Mfr_
data_plus0...............................................................31
Peek Operation using Mfr_data_plus0.....................32
Enabling and Disabling Poke Operations..................32
Poke Operation Using Mfr_data_plus0....................32
Command Plus Operations Using Mfr_data_plus1..32
Operation, Mode and EEPROM Commands..................33
OPERATION.............................................................33
ON_OFF_CONFIG.....................................................34
CLEAR_FAULTS.......................................................34
STORE_USER_ALL and RESTORE_USER_ALL......35
CAPABILITY.............................................................35
VOUT_MODE............................................................35
Output Voltage Related Commands..............................36
VOUT_COMMAND, VOUT_MAX, VOUT_MARGIN_
HIGH, VOUT_MARGIN_LOW, VOUT_OV_FAULT_
LIMIT, VOUT_OV_WARN_LIMIT, VOUT_UV_WARN_
LIMIT, VOUT_UV_FAULT_LIMIT, POWER_GOOD_ON
and POWER_GOOD_OFF.........................................36
Input Voltage Related Commands................................36
VIN_ON, VIN_OFF, VIN_OV_FAULT_LIMIT, VIN_OV_
WARN_LIMIT, VIN_UV_WARN_LIMIT and VIN_UV_
FAULT_LIMIT...........................................................36
Temperature Related Commands.................................37
OT_FAULT_LIMIT, OT_WARN_LIMIT, UT_WARN_
LIMIT and UT_FAULT_LIMIT....................................37
Timer Limits.................................................................37
TON_DELAY, TON_RISE, TON_MAX_FAULT_LIMIT
and TOFF_DELAY.....................................................37
Fault Response for Voltages Measured by the High
Speed Supervisor.........................................................38
VOUT_OV_FAULT_RESPONSE and VOUT_UV_
FAULT_RESPONSE...................................................38
Fault Response for Values Measured by the ADC.........39
OT_FAULT_RESPONSE, UT_FAULT_RESPONSE,
VIN_OV_FAULT_RESPONSE and VIN_UV_FAULT_
RESPONSE...............................................................39
Timed Fault Response..................................................40
TON_MAX_FAULT_RESPONSE...............................40
Status Commands........................................................41
STATUS_BYTE:........................................................41
STATUS_WORD:......................................................41
STATUS_VOUT.........................................................42
STATUS_INPUT.......................................................42
STATUS_TEMPERATURE.........................................42
STATUS_CML..........................................................43
STATUS_MFR_SPECIFIC.........................................43
ADC Monitoring Commands.........................................44
READ_VIN................................................................44
READ_VOUT............................................................44
READ_TEMPERATURE_1.........................................44
PMBUS_REVISION..................................................44
Manufacturer Specific Commands...............................45
MFR_CONFIG_LTC2977..........................................45
Tracking Supplies On and Off...................................46
Tracking Implementation.........................................48
MFR_CONFIG_ALL_LTC2977..................................49
MFR_FAULTBz0_PROPAGATE, MFR_FAULTBz1_
PROPAGATE.............................................................50
2977f
2
For more information www.linear.com/LTC2977
LTC2977
Table of Contents
MFR_PWRGD_EN....................................................51
MFR_FAULTB00_RESPONSE, MFR_FAULTB01_
RESPONSE, MFR_FAULTB10_RESPONSE and MFR_
FAULTB11_RESPONSE.............................................52
MFR_VINEN_OV_FAULT_RESPONSE......................53
MFR_VINEN_UV_FAULT_RESPONSE......................54
MFR_RETRY_COUNT..............................................55
MFR_RETRY_DELAY...............................................55
MFR_RESTART_DELAY...........................................55
MFR_VOUT_PEAK...................................................56
MFR_VIN_PEAK......................................................56
MFR_TEMPERATURE_PEAK...................................56
MFR_DAC................................................................57
MFR_POWERGOOD_ASSERTION_DELAY..............57
MFR_PADS..............................................................58
MFR_SPECIAL_ID...................................................59
MFR_SPECIAL_LOT................................................59
MFR_VOUT_DISCHARGE_THRESHOLD..................59
MFR_COMMON.......................................................60
USER_DATA_00, USER_DATA_01, USER_DATA_02,
USER_DATA_03, USER_DATA_04, MFR_LTC_
RESERVED_1 and MFR_LTC_RESERVED_2............60
MFR_VOUT_MIN......................................................61
MFR_VIN_MIN.........................................................61
MFR_TEMPERATURE_MIN......................................61
MFR_STATUS_2......................................................62
MFR_TELEMETRY...................................................63
Watchdog Operation.....................................................64
MFR_WATCHDOG_T_FIRST and MFR_
WATCHDOG_T.........................................................64
Bulk Programming the User EEPROM Space...............65
MFR_EE_UNLOCK...................................................65
MFR_EE_ERASE......................................................66
MFR_EE_DATA........................................................66
Response When Part Is Busy...................................67
MFR_EE Erase and Write Programming Time.........67
Fault Log Operation......................................................67
MFR_FAULT_LOG_STORE.......................................67
MFR_FAULT_LOG_RESTORE..................................67
MFR_FAULT_LOG_CLEAR.......................................68
MFR_FAULT_LOG_STATUS.....................................68
MFR_FAULT_LOG....................................................69
Applications Information.................................... 76
Overview......................................................................76
Powering the LTC2977.................................................76
Setting Command Register Values...............................76
Sequence, Servo, Margin and Restart Operations........76
Command Units On or Off.......................................76
On Sequencing.........................................................77
On State Operation...................................................77
Servo Modes............................................................77
DAC Modes..............................................................77
Margining.................................................................78
Off Sequencing........................................................78
VOUT Off Threshold Voltage.....................................78
Automatic Restart Via MFR_RESTART_DELAY
Command and CONTROLn pin.................................78
Fault Management........................................................78
Output Overvoltage and Undervoltage Faults..........78
Output Overvoltage and Undervoltage Warnings.....79
Configuring the VIN_EN Output.................................79
Multichannel Fault Management .............................81
Interconnect Between Multiple LTC2977’s...................81
Application Circuits......................................................82
Trimming and Margining DC/DC Converters with
External Feedback Resistors....................................82
Four-Step Resistor Selection Procedure for DC/DC
Converters with External Feedback Resistors..........83
Trimming and Margining DC/DC Converters with a
TRIM Pin..................................................................83
Two-Step Resistor and DAC Full-Scale Voltage
Selection Procedure for DC/DC Converters with a
TRIM Pin..................................................................84
Measuring Current...................................................84
Measuring Current with a Sense Resistor................84
Measuring Current with Inductor DCR.....................84
Single Phase Design Example..................................85
Measuring Multiphase Currents...............................85
Multiphase Design Example.....................................85
Anti-aliasing Filter Considerations...........................86
Sensing Negative Voltages.......................................86
Connecting the DC1613 USB to I2C/SMBus/PMBus
Controller to the LTC2977 in System...........................87
Design Checklist...........................................................88
LTpowerPlay: An Interactive GUI for Power System
Managers.....................................................................89
PCB Assembly and Layout Suggestions.......................90
Bypass Capacitor Placement...................................90
Exposed Pad Stencil Design....................................90
PC Board Layout......................................................90
Unused ADC Sense Inputs.......................................90
Package Description......................................... 91
Typical Application........................................... 92
Related Parts.................................................. 92
2977f
For more information www.linear.com/LTC2977
3
LTC2977
Supply Voltages:
VPWR to GND.......................................... –0.3V to 15V
VDD33 to GND........................................ –0.3V to 3.6V
VDD25 to GND...................................... –0.3V to 2.75V
Digital Input/Output Voltages:
ALERTB, SDA, SCL, CONTROL0,
CONTROL1............................................. –0.3V to 5.5V
PWRGD, SHARE_CLK,
WDI/RESETB, WP.....................–0.3V to VDD33 + 0.3V
FAULTB00, FAULTB01, FAULTB10,
FAULTB11.................................–0.3V to VDD33 + 0.3V
ASEL0, ASEL1...........................–0.3V to VDD33 + 0.3V
Analog Voltages:
REFP.................................................... –0.3V to 1.35V
REFM to GND......................................... –0.3V to 0.3V
VIN_SNS to GND...................................... –0.3V to 15V
VSENSEP[7:0] to GND.................................. –0.3V to 6V
VSENSEM[7:0] to GND................................. –0.3V to 6V
VOUT_EN[3:0], VIN_EN to GND................... –0.3V to 15V
VOUT_EN[7:4] to GND.................................. –0.3V to 6V
VDACP[7:0] to GND..................................... –0.3V to 6V
VDACM[7:0] to GND ................................. –0.3V to 0.3V
Operating Junction Temperature Range:
LTC2977C................................................. 0°C to 70°C
LTC2977I.......................................... –40°C to 105°C*
Storage Temperature Range................... –65°C to 150°C
Maximum Junction Temperature......................... 125°C*
Pin Configuration
TOP VIEW
64 VSENSEP6
63 VSENSEM5
62 VSENSEP5
61 VDACM7
60 VDACP7
59 VDACP6
58 VDACM6
57 VDACM5
56 VDACP5
55 VDACP4
54 VDACM4
53 VSENSEM4
52 VSENSEP4
51 VDACM3
50 VDACP3
49 VSENSEM3
(Notes 1, 2)
VSENSEM6 1
VSENSEP7 2
VSENSEM7 3
VOUT_EN0 4
VOUT_EN1 5
VOUT_EN2 6
VOUT_EN3 7
VOUT_EN4 8
VOUT_EN5 9
VOUT_EN6 10
VOUT_EN7 11
VIN_EN 12
DNC 13
VIN_SNS 14
VPWR 15
VDD33 16
65
GND
48 VSENSEP3
47 VSENSEM2
46 VSENSEP2
45 VDACM2
44 VDACP2
43 VSENSEM1
42 VSENSEP1
41 VDACM1
40 VDACP1
39 VDACP0
38 VDACM0
37 VSENSEM0
36 VSENSEP0
35 REFM
34 REFP
33 ASEL1
VDD33 17
VDD25 18
WP 19
PWRGD 20
SHARE_CLK 21
WDI/RESETB 22
FAULTB00 23
FAULTB01 24
FAULTB10 25
FAULTB11 26
SDA 27
SCL 28
ALERTB 29
CONTROL0 30
CONTROL1 31
ASEL0 32
Absolute Maximum Ratings
UP PACKAGE
64-LEAD (9mm × 9mm) PLASTIC QFN
TJMAX = 125°C, θJA-TOP = 28°C/W, θJC-BOTTOM = 1°C/W
EXPOSED PAD (PIN 65) IS GND, MUST BE SOLDERED TO PCB
*See OPERATION section for detailed EEPROM derating information for junction temperatures in excess
of 105°C.
Order Information
LEAD FREE FINISH
TAPE AND REEL
PART MARKING*
PACKAGE DESCRIPTION
JUNCTION TEMPERATURE RANGE
LTC2977CUP#PBF
LTC2977CUP#TRPBF
LTC2977UP
64-Lead (9mm × 9mm) Plastic QFN
0°C to 70°C
LTC2977IUP#PBF
LTC2977IUP#TRPBF
LTC2977UP
64-Lead (9mm × 9mm) Plastic QFN
–40°C to 105°C
Consult LTC Marketing for parts specified with wider operating temperature ranges. *The temperature grade is identified by a label on the shipping
container. Consult LTC Marketing for information on non-standard lead based finish parts.
For more information on lead free part marking, go to: http://www.linear.com/leadfree/
For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/
2977f
4
For more information www.linear.com/LTC2977
LTC2977
Electrical Characteristics
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TJ = 25°C. VPWR = VIN_SNS = 12V, VDD33, VDD25, REFP and REFM pins floating,
unless otherwise indicated. CVDD33 = 100nF, CVDD25 = 100nF and CREF = 100nF.
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
15
V
10
13
mA
10
13
mA
2.55
2.8
V
Power Supply Characteristics
VPWR
VPWR Supply Input Operating Range
IPWR
VPWR Supply Current
4.5V ≤ VPWR ≤ 15V, VDD33 Floating
l
IVDD33
VDD33 Supply Current
3.13V ≤ VDD33 ≤ 3.47V, VPWR = VDD33
l
VUVLO_VDD33
VDD33 Undervoltage Lockout
VDD33 Ramping Up, VPWR = VDD33
l
l
4.5
2.35
VDD33 Undervoltage Lockout
Hysteresis
VDD33
VDD25
120
Supply Input Operating Range
VPWR = VDD33
l
3.13
Regulator Output Voltage
4.5V ≤ VPWR ≤ 15V
3.47
V
l
3.13
3.26
3.47
V
Regulator Output Short-Circuit Current VPWR = 4.5V, VDD33 = 0V
l
75
90
140
mA
Regulator Output Voltage
l
2.35
2.5
2.6
V
l
30
55
80
mA
3.13V ≤ VDD33 ≤ 3.47V
Regulator Output Short-Circuit Current VPWR = VDD33 = 3.47V, VDD25 = 0V
tINIT
mV
Initialization Time
Time from VIN Applied Until the
TON_DELAY Timer Starts
30
ms
Voltage Reference Characteristics
VREF
Output Voltage
VREF = VREFP – VREFM, 0 < IREFP < 100µA
1.232
Temperature Coefficient
Hysteresis
V
3
(Note 3)
ppm/°C
100
ppm
ADC Characteristics
Differential Voltage:
VIN_ADC = (VSENSEPn – VSENSEMn)
l
0
6
V
Single-Ended Voltage: VSENSEMn
l
–0.1
0.1
V
Current Sense Input Range (Odd
Numbered Channels Only)
Single-Ended Voltage: VSENSEPn, VSENSEMn
l
–0.1
6
V
Differential Voltage: VIN_ADC
l
–170
170
Voltage Sense Resolution Uses L16
Format
0V ≤ VIN_ADC ≤ 6V
Current Sense Resolution (Odd
Numbered Channels Only)
0mV ≤ |VIN_ADC| < 16mV (Note13)
16mV ≤ |VIN_ADC| < 32mV
32mV ≤ |VIN_ADC| < 63.9mV
63.9mV ≤ |VIN_ADC| < 127.9mV
127.9mV ≤ |VIN_ADC|
TUE_ADC
Total Unadjusted Error
VIN_ADC ≥ 1.8V (Note 4)
l
INL_ADC
Integral Nonlinearity
Voltage Sense Mode (Note 5)
l
±854
µV
Current Sense Mode, Odd Numbered
Channels Only, 15.6µV/LSB (Note 5)
l
±31.3
µV
Voltage Sense Mode
l
±400
µV
Current Sense Mode, Odd Numbered
Channels Only
l
±31.3
µV
Voltage Sense Mode
l
±250
µV
Current Sense Mode, Odd Numbered
Channels Only
l
±35
µV
Voltage Sense Mode, VIN_ADC = 6V
l
±0.2
%
Current Sense Mode, Odd Numbered
Channels Only, VIN_ADC = ±0.17V
l
±0.35
%
VIN_ADC
N_ADC
DNL_ADC
VOS_ADC
GAIN_ADC
Voltage Sense Input Range
Differential Nonlinearity
Offset Error
Gain Error
mV
122
µV/LSB
15.625
31.25
62.5
125
250
µV/LSB
µV/LSB
µV/LSB
µV/LSB
µV/LSB
±0.25
%
2977f
For more information www.linear.com/LTC2977
5
LTC2977
Electrical Characteristics
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TJ = 25°C. VPWR = VIN_SNS = 12V; VDD33, VDD25, REFP and REFM pins floating,
unless otherwise indicated. CVDD33 = 100nF, CVDD25 = 100nF and CREF = 100nF.
SYMBOL
PARAMETER
CONDITIONS
tCONV_ADC
Conversion Time
Voltage Sense Mode (Note 6)
6.15
ms
Current Sense Mode (Note 6)
24.6
ms
Temperature Input (Note 6)
24.6
ms
Odd Numbered Channels in Current Sense
Mode (Note 6)
160
ms
tUPDATE_ADC
Maximum Update Time
MIN
CIN_ADC
Input Sampling Capacitance
fIN_ADC
Input Sampling Frequency
IIN_ADC
Input Leakage Current
VIN_ADC = 0V, 0V ≤ VCOMMONMODE ≤ 6V,
Current Sense Mode
l
Differential Input Current
VIN_ADC = 0.17V, Current Sense Mode
l
VIN_ADC = 6V, Voltage Sense Mode
l
TYP
MAX
UNITS
1
pF
62.5
kHz
±0.5
µA
80
250
nA
10
15
µA
Voltage Buffered IDAC Output Characteristics
N_VDACP
Resolution
VFS_VDACP
Full-Scale Output Voltage
(Programmable)
DAC Code = 0x3FF Buffer Gain Setting_0
DAC Polarity = 1
Buffer Gain Setting_1
l
l
INL_VDACP
Integral Nonlinearity
(Note 7)
l
±2
LSB
DNL_VDACP
Differential Nonlinearity
(Note 7)
l
±2.4
LSB
VOS_VDACP
Offset Voltage
(Note 7)
l
VDACP
Load Regulation (VDACPn – VDACMn)
VDACPn = 2.65V, IVDACPn Sourcing = 2mA
100
ppm/mA
VDACPn = 0.1V, IVDACPn Sinking = 2mA
100
ppm/mA
DC: 3.13V ≤ VDD33 ≤ 3.47V, VPWR = VDD33
60
dB
100mV Step in 20ns with 50pF Load
40
dB
PSRR (VDACPn – VDACMn)
10
1.32
2.53
1.38
2.65
Bits
1.44
2.77
±10
DC CMRR (VDACPn – VDACMn)
–0.1V ≤ VDACMn ≤ 0.1V
Leakage Current
VDACPn Hi-Z, 0V ≤ VDACPn ≤ 6V
l
60
Short-Circuit Current Low
VDACPn Shorted to GND
l
–10
l
4
V
V
mV
dB
±100
nA
–4
mA
10
mA
Short-Circuit Current High
VDACPn Shorted to VDD33
COUT
Output Capacitance
VDACPn Hi-Z
10
pF
tS_VDACP
DAC Output Update Rate
Fast Servo Mode
250
µs
Voltage Supervisor Characteristics
VIN_VS
N_VS
TUE_VS
tS_VS
Input Voltage Range (Programmable)
Voltage Sensing Resolution
Total Unadjusted Error
VIN_VS = (VSENSEPn Low Resolution Mode
– VSENSEMn)
High Resolution Mode
l
l
0
0
6
3.8
V
V
Single-Ended Voltage: VSENSEMn
l
–0.1
0.1
V
0V to 3.8V Range: High Resolution Mode
4
mV/LSB
0V to 6V Range: Low Resolution Mode
8
mV/LSB
2V ≤ VIN_VS ≤ 6V, Low Resolution Mode
l
±1.25
%
1.5V < VIN_VS ≤ 3.8V, High Resolution
Mode
l
±1.0
%
0.8V ≤ VIN_VS ≤ 1.5V, High Resolution
Mode
l
±1.5
%
Update Rate
12.21
µs
VIN_SNS Input Characteristics
VVIN_SNS
VIN_SNS Input Voltage Range
l
0
RVIN_SNS
VIN_SNS Input Resistance
l
70
15
90
110
V
kΩ
2977f
6
For more information www.linear.com/LTC2977
LTC2977
Electrical Characteristics
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TJ = 25°C. VPWR = VIN_SNS = 12V; VDD33, VDD25, REFP and REFM pins floating,
unless otherwise indicated. CVDD33 = 100nF, CVDD25 = 100nF and CREF = 100nF.
SYMBOL
PARAMETER
CONDITIONS
TUEVIN_SNS
VIN_ON, VIN_OFF Threshold Total
Unadjusted Error
READ_VIN Total Unadjusted Error
MAX
UNITS
3V ≤ VVIN_SNS ≤ 8V
l
MIN
TYP
±2.0
%
VVIN_SNS > 8V
l
±1.0
%
3V ≤ VVIN_SNS ≤ 8V
l
±1.5
%
VVIN_SNS > 8V
l
±1.0
%
±18
mV
DAC Soft-Connect Comparator Characteristics
VOS_CMP
Offset Voltage
±3
l
Temperature Sensor Characteristics
TUE_TS
Total Unadjusted Error
±1
°C
VOUT Enable Output (VOUT_EN [3:0]) Characteristics
VVOUT_ENn
Output High Voltage (Note 12)
IVOUT_ENn = –5µA, VDD33 = 3.3V
IVOUT_ENn
Output Sourcing Current
Output Sinking Current
Output Leakage Current
11.6
12.5
14.7
VVOUT_ENn Pull-Up Enabled, VVOUT_ENn = 1V l
–5
–6
–8
µA
Strong Pull-Down Enabled,
VVOUT_ENn = 0.4V
l
3
5
8
mA
Weak Pull-Down Enabled, VVOUT_ENn = 0.4V l
33
50
60
µA
±1
µA
9
mA
±1
µA
V
l
Internal Pull-Up Disabled,
0V ≤ VVOUT_ENn ≤ 15V
l
Output Sinking Current
Strong Pull-Down Enabled,
VOUT_ENn = 0.1V
l
Output Leakage Current
0V ≤ VVOUT_ENn ≤ 6V
l
IVIN_EN = –5µA, VDD33 = 3.3V
l
11.6
12.5
14.7
V
VOUT Enable Output (VOUT_EN [7:4]) Characteristics
IVOUT_ENn
3
6
VIN Enable Output (VIN_EN) Characteristics
VVIN_EN
IVIN_EN
Output High Voltage
Output Sourcing Current
VIN_EN Pull-Up Enabled, VVIN_EN = 1V
l
–5
–6
–8
µA
Output Sinking Current
VVIN_EN = 0.4V
l
3
5
8
mA
Leakage Current
Internal Pull-Up Disabled,
0V ≤ VVIN_EN ≤ 15V
l
±1
µA
0°C < TJ < 85°C During EEPROM Write
Operations
l
10,000
l
20
EEPROM Characteristics
Endurance
(Notes 8, 11)
Retention
(Notes 8, 11)
TJ < 105°C
tMASS_WRITE
Mass Write Operation Time (Note 9)
STORE_USER_ALL, 0°C < TJ < 85°C During l
EEPROM Write Operations
Cycles
Years
440
4100
ms
Digital Inputs SCL, SDA, CONTROL0, CONTROL1, WDI/RESETB, FAULTB00, FAULTB01, FAULTB10, FAULTB11, WP
VIH
High Level Input Voltage
l
VIL
Low Level Input Voltage
l
VHYST
Input Hysteresis
ILEAK
Input Leakage Current
tSP
tFAULT_MIN
Pulse Width of Spike Suppressed
2.1
V
1.5
20
V
mV
0V ≤ VPIN ≤ 5.5V, SDA, SCL, CONTROLn
Pins Only
l
±2
µA
0V ≤ VPIN ≤ VDD33 + 0.3V, FAULTBzn,
WDI/RESETB, WP Pins Only
l
±2
µA
FAULTBzn, CONTROLn Pins Only
10
µs
SDA, SCL Pins Only
98
ns
Minimum Low Pulse Width for
Externally Generated Faults
110
ms
2977f
For more information www.linear.com/LTC2977
7
LTC2977
Electrical Characteristics
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TJ = 25°C. VPWR = VIN_SNS = 12V; VDD33, VDD25, REFP and REFM pins floating,
unless otherwise indicated. CVDD33 = 100nF, CVDD25 = 100nF and CREF = 100nF.
SYMBOL
PARAMETER
CONDITIONS
MIN
tRESETB
Pulse Width to Assert Reset
VWDI/RESETB ≤ 1.5V
l
300
tWDI
Pulse Width to Reset Watchdog Timer
VWDI/RESETB ≤ 1.5V
l
0.3
fWDI
Watchdog Interrupt Input Frequency
CIN
Digital Input Capacitance
TYP
MAX
UNITS
µs
200
1
l
10
µs
MHz
pF
Digital Input SHARE_CLK
VIH
High Level Input Voltage
l
VIL
Low Level Input Voltage
l
fSHARE_CLK_IN Input Frequency Operating Range
1.6
l
90
0.825
V
0.8
V
110
kHz
tLOW
Assertion Low Time
VSHARE_CLK < 0.8V
l
1.1
µs
tRISE
Rise Time
VSHARE_CLK < 0.8V to VSHARE_CLK > 1.6V
l
450
ns
ILEAK
Input Leakage Current
0V ≤ VSHARE_CLK ≤ VDD33 + 0.3V
l
±1
µA
CIN
Input Capacitance
10
pF
Digital Outputs SDA, ALERTB, PWRGD, SHARE_CLK, FAULTB00, FAULTB01, FAULTB10, FAULTB11
VOL
Digital Output Low Voltage
fSHARE_CLK_OUT Output Frequency Operating Range
ISINK = 3mA
l
5.49kΩ Pull-Up to VDD33
l
90
VDD33 – 0.5
100
0.4
V
110
kHz
Digital Inputs ASEL0,ASEL1
VIH
Input High Threshold Voltage
l
VIL
Input Low Threshold Voltage
l
0.5
V
IIH,IL
High, Low Input Current
l
±95
µA
IIH, Z
Hi-Z Input Current
l
±24
µA
CIN
Input Capacitance
ASEL[1:0] = 0, VDD33
V
10
pF
Serial Bus Timing Characteristics
fSCL
Serial Clock Frequency (Note 10)
l
10
400
tLOW
Serial Clock Low Period (Note 10)
l
1.3
µs
tHIGH
Serial Clock High Period (Note 10)
l
0.6
µs
tBUF
Bus Free Time Between Stop and Start
(Note 10)
l
1.3
µs
tHD,STA
Start Condition Hold Time (Note 10)
l
600
ns
tSU,STA
Start Condition Setup Time (Note 10)
l
600
ns
tSU,STO
Stop Condition Setup Time (Note 10)
l
600
ns
tHD,DAT
Data Hold Time (LTC2977 Receiving
Data) (Note 10)
l
0
ns
Data Hold Time (LTC2977 Transmitting
Data) (Note 10)
l
300
tSU,DAT
Data Setup Time (Note 10)
l
100
tSP
Pulse Width of Spike Suppressed
(Note 10)
tTIMEOUT_BUS
Time Allowed to Complete any PMBus Longer Timeout = 0
Command After Which Time SDA Will Longer Timeout = 1
Be Released and Command Terminated
900
ns
ns
98
l
l
kHz
25
200
ns
35
280
ms
ms
Additional Digital Timing Characteristics
tOFF_MIN
Minimum Off Time for Any Channel
100
ms
2977f
8
For more information www.linear.com/LTC2977
LTC2977
Electrical Characteristics
Note 1: Stresses beyond those listed under Absolute Maximum Ratings may
cause permanent damage to the device. Exposure to any Absolute Maximum
Rating for extended periods may affect device reliability and lifetime.
Note 2: All currents into device pins are positive. All currents out of device
pins are negative. All voltages are referenced to ground unless otherwise
specified. If power is supplied to the chip via the VDD33 pin only, connect
VPWR and VDD33 pins together.
Note 3: Hysteresis in the output voltage is created by package stress that
differs depending on whether the IC was previously at a higher or lower
temperature. Output voltage is always measured at 25°C, but the IC is
cycled to 105°C or –40°C before successive measurements. Hysteresis is
roughly proportional to the square of the temperature change.
Note 4: TUE(%) is defined as:
Gain Error (%) + 100 • (INL + VOS)/VIN.
Note 5: Integral nonlinearity (INL) is defined as the deviation of a code
from a straight line passing through the actual endpoints of the transfer
curve (0V and 6V). The deviation is measured from the center of the
quantization band.
Note 6: The time between successive ADC conversions (latency of the
ADC) for any given channel is given as: 36.9ms + (6.15ms • number of
ADC channels configured in Low Resolution mode) + (24.6ms • number of
ADC channels configured in High Resolution mode).
Note 7: Nonlinearity is defined from the first code that is greater than or
equal to the maximum offset specification to full-scale code, 1023.
Note 8: EEPROM endurance and retention are guaranteed by design,
characterization and correlation with statistical process controls. The
minimum retention specification applies for devices whose EEPROM has
been cycled less than the minimum endurance specification.
Note 9: The LTC2977 will not acknowledge any PMBus commands except
for MFR_COMMON, while a mass write operation is being executed. This
includes the STORE_USER_ALL and MFR_FAULT_LOG_STORE commands
or a fault log store initiated by a channel faulting off.
Note 10: Maximum capacitive load, CB, for SCL and SDA is 400pF. Data
and clock rise time (tr) and fall time (tf) are: (20 + 0.1 • CB) (ns) < tr < 300ns
and (20 + 0.1 • CB) (ns) < tf < 300ns. CB = capacitance of one bus line in pF.
SCL and SDA external pull-up voltage, VIO, is 3.13V < VIO < 5.5V.
Note 11: EEPROM endurance and retention will be degraded when TJ > 105°C.
Note 12: Output enable pins are charge-pumped from VDD33.
Note 13: The current sense resolution is determined by the L11 format
and the mV units of the returned value. For example, a full-scale value
of 170mV returns an L11 value of 0xF2A8 = 680 • 2–2 = 170. This is the
lowest range that can represent this value without overflowing the L11
mantissa and the resolution for 1LSB in this range is 2–2 mV = 250µV.
Each successively lower range improves resolution by cutting the LSB size
in half.
PMBus Timing Diagram
SDA
tf
tLOW
tr
tSU(DAT)
tHD(SDA)
tf
tSP
tr
tBUF
SCL
tHD(STA)
START
CONDITION
tHD(DAT)
tHIGH
tSU(STA)
tSU(STO)
2977 TD
REPEATED START
CONDITION
STOP
CONDITION
START
CONDITION
2977f
For more information www.linear.com/LTC2977
9
LTC2977
Typical Performance Characteristics
Temperature Sensor Error
vs Temperature
Reference Voltage vs Temperature
1.2325
ADC Total Unadjusted Error
vs Temperature
1.6
0.25
1.2320
1.4
0.20
1.2315
1.2
1.2310
1.0
1.2305
1.2300
0.6
0.4
1.2290
0.2
1.2285
0
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
90
0.15
0.8
1.2295
110
–0.20
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
110
90
–0.25
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
2.5
ERROR (LSBs)
100
50
0
–50
–100
ADC-DNL
0.8
122µV/LSB
2.0
0.4
1.5
0.2
1.0
0
–0.2
0.5
–0.4
0
–150
–0.6
–200
–1.0
–0.8
90
–1.5
–0.2
110
0.8
1.8
2.8
3.8
4.8
INPUT VOLTAGE (V)
SUPERVISOR ERROR (%)
NUMBER OF READINGS
600
400
200
0
–20
–10
0
10
READ_VOUT (µV)
20
2977 G07
1.8
2.8
3.8
4.8
INPUT VOLTAGE (V)
5.8
Input Sampling Current
vs Differential Input Voltage
9
1.0
VIN = 0V
HIGH RESOLUTION MODE
800
0.8
2977 G06
Voltage Supervisor Total
Unadjusted Error vs Temperature
ADC Noise Histogram
1000
–1.0
–0.2
2977 G05
2977 G04
1200
5.8
VSENSEP0 = 1.5V
0.8 HIGH RESOLUTION MODE
THREE TYPICAL PARTS
0.6
8
INPUT SAMPLING CURRENT (µA)
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
122µV/LSB
0.6
–0.5
–250
110
2977 G03
ERROR (LSBs)
VOLTAGE SENSE MODE
THREE TYPICAL PARTS
90
2977 G02
ADC-INL
3.0
150
OFFSET (µV)
0
–0.05
–0.15
ADC Zero Code Center Offset
Voltage vs Temperature
200
0.05
–0.10
2977 G01
250
VSENSEP0 = 1.8V
THREE TYPICAL PARTS
0.10
ERROR (%)
ERROR (°C)
REFERENCE OUTPUT VOLTAGE (V)
THREE TYPICAL PARTS
0.4
0.2
0
–0.2
–0.4
–0.6
7
6
5
4
3
2
–0.8
1
–1.0
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
0
90
110
2977 G08
0
1
2
3
4
INPUT VOLTAGE (V)
5
6
2977 G09
2977f
10
For more information www.linear.com/LTC2977
LTC2977
Typical Performance Characteristics
DAC Full-Scale Output Voltage vs
Temperature
2.68
80
2.67
70
60
50
40
30
20
10
GAIN SETTING = 1
THREE TYPICAL PARTS
8
2.66
2.65
2.64
2.63
2.62
2.61
10
0
DAC Offset Voltage vs
Temperature
DAC OUTPUT VOLTAGE (mV)
90
DAC OUTPUT VOLTAGE (V)
DIFFERENTIAL INPUT CURRENT (nA)
ADC High Resolution Mode
Differential Input Current
0
20 40 60 80 100 120 140 160 180
DIFFERENTIAL INPUT VOLTAGE (mV)
2.60
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
90
0
–2
–4
–6
110
–10
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
90
110
2977 G12
1000
GAIN SETTING = 1
THREE TYPICAL PARTS
OUTPUT IMPEDANCE (Ω)
SHORT-CIRCUIT CURRENT (mA)
2
DAC Output Impedance vs
Frequency
8
7
6
5
4
4
2977 G11
DAC Short-Circuit Current vs
Temperature
9
6
–8
2977 G10
10
GAIN SETTING = 1
THREE TYPICAL PARTS
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
90
100
10
1
0.1
0.01
0.01
110
0.1
2977 G13
10
1
FREQUENCY (kHz)
DAC Soft-Connect Transient
Response when Transitioning from
Hi-Z State to ON State
DAC Transient Response to 1LSB
DAC Code Change
100
1000
2977 G14
DAC Soft-Connect Transient
Response when Transitioning from
ON State to Hi-Z State
CODE ‘h200
HI-Z
500µV/DIV
HI-Z
10mV/DIV
10mV/DIV
CONNECTED
CODE ‘h1FF
2µs/DIV
2977 G15
500µs/DIV
100k SERIES RESISTANCE ON
CODE: ‘h1FF
CONNECTED
2977 G16
500µs/DIV
100k SERIES RESISTANCE ON
CODE: ‘h1FF
2977 G17
2977f
For more information www.linear.com/LTC2977
11
LTC2977
Typical Performance Characteristics
VDD33 Regulator Output Voltage
vs Temperature
VDD33 Regulator Load Regulation
THREE TYPICAL PARTS
3.26
3.28
3.24
3.27
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
Supply Current vs Supply Voltage
3.28
3.26
3.25
3.24
–40°C
3.22
3.20
25°C
SUPPLY CURRENT (mA)
3.29
105°C
3.18
3.16
3.14
3.23
3.12
3.22
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
90
110
3.10
0
20
40
60
80
100
CURRENT SOURCING (mA)
2977 G18
4
6
8
12
10
SUPPLY VOLTAGE (V)
13.5
OUTUPT HIGH VOLTAGE (V)
9.3
9.2
9.1
9.0
8.9
2977 G20
105°C
13.0
25°C
12.5
–40°C
12.0
11.5
11.0
10.5
10.0
8.8
–50 –30 –10 10 30 50 70
TEMPERATURE (°C)
90
9.5
110
0
2
3
4
5
CURRENT SOURCING (µA)
1
7
6
2977 G21
2977 G22
VOUT_EN[3:0] and VIN_EN Output
VOL vs Current
VOUT_EN[7:4] VOL vs Current
0.6
1.4
1.2
105°C
105°C
0.5
25°C
1.0
25°C
0.4
0.8
VOL (V)
VOL (V)
16
14.0
VPWR = 15V
9.4
–40°C
0.6
0.3
–40°C
0.2
0.4
0.1
0.2
0
14
VOUT_EN[3:0] and VIN_EN Output
High Voltage vs Current
9.5
SUPPLY CURRENT (mA)
TEMPERATURE = 33°C
THREE TYPICAL PARTS
2977 G19
Supply Current vs Temperature
9.6
120
9.24
9.22
9.20
9.18
9.16
9.14
9.12
9.10
9.08
9.06
9.04
9.02
9.00
8.98
8.96
0
2
8
6
10
4
CURRENT SINKING (mA)
12
0
0
2977 G23
4
8
12
16
20
CURRENT SINKING (mA)
24
2977 G24
2977f
12
For more information www.linear.com/LTC2977
LTC2977
Pin Functions
PIN NAME
VSENSEM6
VSENSEP7
VSENSEM7
VOUT_EN0
VOUT_EN1
VOUT_EN2
VOUT_EN3
VOUT_EN4
VOUT_EN5
VOUT_EN6
VOUT_EN7
VIN_EN
DNC
VIN_SNS
PIN NUMBER
PIN TYPE
1*
In
2*
In
3*
In
4
Out
5
Out
6
Out
7
Out
8
Out
9
Out
10
Out
11
Out
12
0ut
13
Do Not Connect
14
In
VPWR
15
In
VDD33
16
In/Out
VDD33
VDD25
WP
PWRGD
17
18
19
20
In
In/Out
In
Out
SHARE_CLK
WDI/RESETB
21
22
In/Out
In
FAULTB00
23
In/Out
FAULTB01
24
In/Out
FAULTB10
25
In/Out
FAULTB11
26
In/Out
SDA
SCL
ALERTB
CONTROL0
CONTROL1
ASEL0
ASEL1
REFP
REFM
VSENSEP0
VSENSEM0
VDACM0
VDACP0
VDACP1
27
28
29
30
31
32
33
34
35
36*
37*
38
39
40
In/Out
In
Out
In
In
In
In
Out
Out
In
In
Out
Out
Out
DESCRIPTION
DC/DC Converter Differential (–) Output Voltage-6 Sensing Pin
DC/DC Converter Differential (+) Output Voltage or Current-7 Sensing Pin
DC/DC Converter Differential (–) Output Voltage or Current-7 Sensing Pin
DC/DC Converter Enable-0 Pin. Output High Voltage Optionally Pulled Up to 12V by 5µA
DC/DC Converter Enable-1 Pin. Output High Voltage Optionally Pulled Up to 12V by 5µA
DC/DC Converter Enable-2 Pin. Output High Voltage Optionally Pulled Up to 12V by 5µA
DC/DC Converter Enable-3 Pin. Output High Voltage Optionally Pulled Up to 12V by 5µA
DC/DC Converter Open-Drain Pull-Down Output-4
DC/DC Converter Open-Drain Pull-Down Output-5
DC/DC Converter Open-Drain Pull-Down Output-6
DC/DC Converter Open-Drain Pull-Down Output-7
DC/DC Converter VIN ENABLE Pin. Output High Voltage Optionally Pulled Up to 12V by 5µA
Do Not Connect to This Pin
VIN SENSE Input. This Voltage is Compared Against the VIN On and Off Voltage Thresholds in Order to
Determine When to Enable and Disable, Respectively, the Downstream DC/DC Converters.
VPWR Serves as the Unregulated Power Supply Input to the Chip (4.5V to 15V). If a 4.5V to 15V Supply
Voltage is Unavailable, Short VPWR to VDD33 and Power the Chip Directly from a 3.3V Supply. Bypass to
GND with 0.1µF Capacitor.
If Shorted to VPWR, it Serves as 3.13V to 3.47V Supply Input Pin. Otherwise, it is a 3.3V Internally
Regulated Voltage Output (Use 0.1µF Decoupling Capacitor to GND).
Input for Internal 2.5V Sub-Regulator. Short This Pin to Pin 16.
2.5V Internally Regulated Voltage Output. Bypass to GND with a 0.1µF Capacitor.
Digital Input. Write-Protect Input Pin, Active High.
Power Good Open-Drain Output. Indicates When Outputs are Power Good. Can be Used as System
Power-On Reset.
Bidirectional Clock Sharing Pin. Connect a 5.49k Pull-Up Resistor to VDD33.
Watchdog Timer Interrupt and Chip Reset Input. Connect a 10k Pull-Up Resistor to VDD33. Rising Edge
Resets Watchdog Counter. Holding This Pin Low for More Than tRESETB Resets the Chip.
Open-Drain Output and Digital Input. Active Low Bidirectional Fault Indicator-00. Connect a 10k Pull-Up
Resistor to VDD33.
Open-Drain Output and Digital Input. Active Low Bidirectional Fault Indicator-01. Connect a 10k Pull-Up
Resistor to VDD33.
Open-Drain Output and Digital Input. Active Low Bidirectional Fault Indicator-10. Connect a 10k Pull-Up
Resistor to VDD33.
Open-Drain Output and Digital Input. Active Low Bidirectional Fault Indicator-11. Connect a 10k Pull-Up
Resistor to VDD33.
PMBus Bidirectional Serial Data Pin
PMBus Serial Clock Input Pin (400kHz Maximum)
Open-Drain Output. Generates an Interrupt Request in a Fault/Warning Situation.
Control Pin 0 Input
Control Pin 1 Input
Ternary Address Select Pin 0 Input. Connect to VDD33, GND or Float to Encode 1 of 3 Logic States.
Ternary Address Select Pin 1 Input. Connect to VDD33, GND or Float to Encode 1 of 3 Logic States.
Reference Voltage Output. Needs 0.1µF Decoupling Capacitor to REFM.
Reference Return Pin. Needs 0.1µF Decoupling Capacitor to REFP.
DC/DC Converter Differential (+) Output Voltage-0 Sensing Pin
DC/DC Converter Differential (–) Output Voltage-0 Sensing Pin
DAC0 Return. Connect to Channel 0 DC/DC Converter’s GND Sense or Return to GND.
DAC0 Output
DAC1 Output
2977f
For more information www.linear.com/LTC2977
13
LTC2977
Pin Functions
PIN NAME
PIN NUMBER
PIN TYPE
DESCRIPTION
41
Out
DAC1 Return. Connect to Channel 1 DC/DC Converter’s GND Sense or Return to GND.
VDACM1
42*
In
DC/DC Converter Differential (+) Output Voltage or Current-1 Sensing Pins
VSENSEP1
43*
In
DC/DC Converter Differential (–) Output Voltage or Current-1 Sensing Pins
VSENSEM1
44
Out
DAC2 Output
VDACP2
45
Out
DAC2 Return. Connect to Channel 2 DC/DC Converter’s GND Sense or Return to GND.
VDACM2
46*
In
DC/DC Converter Differential (+) Output Voltage-2 Sensing Pin
VSENSEP2
47*
In
DC/DC Converter Differential (–) Output Voltage-2 Sensing Pin
VSENSEM2
48*
In
DC/DC Converter Differential (+) Output Voltage or Current-3 Sensing Pins
VSENSEP3
49*
In
DC/DC Converter Differential (–) Output Voltage or Current-3 Sensing Pins
VSENSEM3
50
Out
DAC3 Output
VDACP3
51
Out
DAC3 Return. Connect to Channel 3 DC/DC Converter’s GND Sense or Return to GND.
VDACM3
52*
In
DC/DC Converter Differential (+) Output Voltage-4 Sensing Pin
VSENSEP4
53*
In
DC/DC Converter Differential (–) Output Voltage-4 Sensing Pin
VSENSEM4
54
Out
DAC4 Return. Connect to Channel 4 DC/DC Converter’s GND Sense or Return to GND.
VDACM4
55
Out
DAC4 Output
VDACP4
56
Out
DAC5 Output
VDACP5
57
Out
DAC5 Return. Connect to Channel 5 DC/DC Converter’s GND Sense or Return to GND.
VDACM5
58
Out
DAC6 Return. Connect to Channel 6 DC/DC Converter’s GND Sense or Return to GND.
VDACM6
59
Out
DAC6 Output
VDACP6
60
Out
DAC7 Output
VDACP7
61
Out
DAC7 Return. Connect to Channel 7 DC/DC Converter’s GND Sense or Return to GND.
VDACM7
62*
In
DC/DC Converter Differential (+) Output Voltage or Current-5 Sensing Pins
VSENSEP5
63*
In
DC/DC Converter Differential (–) Output Voltage or Current-5 Sensing Pins
VSENSEM5
64*
In
DC/DC Converter Differential (+) Output Voltage-6 Sensing Pin
VSENSEP6
GND
65
Ground
Exposed Pad, Must be Soldered to PCB
*Any unused VSENSEPn or VSENSEMn or VDACMn pins must be tied to GND.
2977f
14
For more information www.linear.com/LTC2977
LTC2977
Block Diagram
3.3V REGULATOR
VOUT
VIN
VPWR 15
VDD
VDD33 16
2.5V REGULATOR
VIN
VOUT
VIN_SNS 14
3R
VSENSEM0
VSENSEP0
R
VSENSEM1
GND 65
INTERNAL
TEMP
SENSOR
VSENSEP1
36 VSENSEP0
VSENSEM2
37 VSENSEM0
VSENSEP2
42 VSENSEP1
VSENSEM3
43 VSENSEM1
VSENSEP3
46 VSENSEP2
VSENSEM4
MUX
VSENSEP4
CMP0
VSENSEM5
VSENSEP5
+
–
+
–
VDD33 17
VDD25 18
47 VSENSEM2
+
–
48 VSENSEP3
10-BIT
DAC
49 VSENSEM3
52 VSENSEP4
VSENSEM6
53 VSENSEM4
VSENSEP6
62 VSENSEP5
VSENSEM7
63 VSENSEM5
VSENSEP7
64 VSENSEP6
+ 16-BIT
– ∆∑ ADC
1 VSENSEM6
2 VSENSEP7
3 VSENSEM7
ADC
CLOCKS
10-BIT
DAC
VDD
+
–
39 VDACP0
VBUF
40 VDACP1
44 VDACP2
50 VDACP3
REFERENCE
1.232V
(TYP)
REFP 34
55 VDACP4
56 VDACP5
REFM 35
59 VDACP6
60 VDACP7
38 VDACM0
41 VDACM1
SDA 27
ALERTB 29
ASEL0 32
45 VDACM2
NONVOLATILE MEMORY
SCL 28
PMBus
INTERFACE
(400kHz I2C
COMPATIBLE)
ASEL1 33
54 VDACM4
57 VDACM5
RAM
ADC_RESULTS
MONITOR LIMITS
SERVO TARGETS
58 VDACM6
PAGE 7
WP 19
CONTROL1 31
OSCILLATOR
WDI/RESETB 22
FAULTB01 24
FAULTB10 25
61 VDACM7
4 VOUT_EN0
OUTPUT
CONFIG
CONTROL0 30
FAULTB00 23
51 VDACM3
PAGE 0
EEPROM
CONTROLLER
PMBus ALGORITHM
FAULT PROCESSOR
WATCHDOG
SEQUENCER
CLOCK
GENERATION
UVLO
PWRGD 20
6 VOUT_EN2
7 VOUT_EN3
12 VIN_EN
VDD
FAULTB11 26
5 VOUT_EN1
8 VOUT_EN4
OPEN-DRAIN
OUTPUT
9 VOUT_EN5
10 VOUT_EN6
11 VOUT_EN7
SHARE_CLK 21
2977 BD
2977f
For more information www.linear.com/LTC2977
15
LTC2977
Operation
Operation Overview
n
The LTC2977 is a PMBus programmable power system
controller, monitor, sequencer and voltage supervisor that
can perform the following operations:
n
Accept PMBus compatible programming commands.
n
n
n
n
n
n
n
n
n
n
n
Provide DC/DC converter input voltage and output voltage/current readback through the PMBus interface.
Control the output of DC/DC converters that set the
output voltage with a trim pin or DC/DC converters
that set the output voltage using an external resistor
feedback network.
Sequence the start-up of DC/DC converters via PMBus
programming and their control input pins. Time-based
sequencing and tracking sequencing are both supported.
Trim the DC/DC converter output voltage (typically in
0.02% steps), in closed-loop servo operating mode,
through PMBus programming.
n
n
n
n
n
Margin the DC/DC converter output voltage to PMBus
programmed limits.
Allow the user to trim or margin the DC/DC converter
output voltage in a manual operating mode by providing
direct access to the margin DAC.
Supervise the DC/DC converter output voltage, input
voltage, and the LTC2977 die temperature for overvalue/undervalue conditions with respect to PMBus
programmed limits and generate appropriate faults and
warnings.
Respond to a fault condition by either continuing
operation indefinitely, latching off after a programmable
deglitch period, latching off immediately or sequencing
off after TOFF_DELAY. A retry mode may be used to
automatically recover from a latched-off condition.
When enabled, the number of retries (0 to 6 or infinite)
is the same for all pages and is programmed in MFR_
RETRY_COUNT.
n
n
n
n
n
Store command register contents with CRC to EEPROM
through PMBus programming.
Restore EEPROM contents through PMBus programming or when VDD33 is applied on power-up.
Report the DC/DC converter output voltage status
through the PMBus interface and the power good output.
Generate interrupt requests by asserting the ALERTB
pin in response to supported PMBus faults and
warnings.
Coordinate system wide fault responses for all DC/DC
converters connected to the FAULTBz0 and FAULTBz1
pins.
Synchronize sequencing delays or shutdown for multiple
devices using the SHARE_CLK pin.
Software and hardware write protect the command
registers.
Disable the input voltage to the supervised DC/DC
converters in response to output voltage OV and UV
faults.
Log telemetry and status data to EEPROM in response
to a faulted-off condition
Supervise an external microcontroller’s activity for a
stalled condition with a programmable watchdog timer
and reset it if necessary.
Prevent a DC/DC converter from re-entering the ON
state after a power cycle until a programmable interval
(MFR_RESTART_DELAY) has elapsed and its output
has decayed below a programmable threshold voltage
(MFR_VOUT_DISCHARGE_THRESHOLD).
Record minimum and maximum observed values of
input voltage, output voltages and temperature.
Access user EEPROM data directly, without altering
RAM space (MFR_EE_UNLOCK, MFR_EE_ERASE, and
MFR_EE_DATA). Facilitates in-house bulk programming.
Optionally stop trimming the DC/DC converter output
voltage after reaching the initial margin or nominal
target. Optionally allow servo to resume if target drifts
outside of VOUT warning limits.
2977f
16
For more information www.linear.com/LTC2977
LTC2977
Operation
EEPROM
Equivalent operating time at 105°C = 86.5 hours.
The LTC2977 contains internal EEPROM (nonvolatile
memory) to store configuration settings and fault log
information. EEPROM endurance, retention, and mass
write operation time are specified over the operating junction temperature range. See Electrical Characteristics and
Absolute Maximum Ratings sections.
So the overall retention of the EEPROM was degraded by
86.5 hours as a result of operation at a junction temperature of 125°C for 10 hours. Note that the effect of this
overstress is negligible when compared to the overall
EEPROM retention rating of 175,200 hours at a maximum
junction temperature of 105°C.
Nondestructive operation above TJ = 105°C is possible
although the Electrical Characteristics are not guaranteed
and the EEPROM will be degraded.
Reset
Operating the EEPROM above 105°C may result in a
degradation of retention characteristics. The fault logging
function, which is useful in debugging system problems
that may occur at high temperatures, only writes to fault
log EEPROM locations. If occasional writes to these
registers occur above 105°C, a slight degradation in the
data retention characteristics of the fault log may occur.
It is recommended that the EEPROM not be written using
STORE_USER_ALL or bulk programming when TJ > 85°C.
The degradation in EEPROM retention for temperatures
>105°C can be approximated by calculating the dimensionless acceleration factor using the following equation.
AF = e
 Ea  

1
1
−
  • 

 k   TUSE + 273 TSTRESS + 273 
Where:
AF = acceleration factor
Ea = activation energy = 1.4 eV
k = 8.625×10−5 eV/°K
TUSE = 105°C specified junction temperature
TSTRESS = actual junction temperature °C
Example: Calculate the effect on retention when operating
at a junction temperature of 125°C for 10 hours.
TSTRESS = 125°C
TUSE = 105°C
Holding the WDI/RESETB pin low for more than tRESETB
will cause the LTC2977 to enter the power-on reset state.
While in the power-on reset state, the device will not
communicate on the I2C bus. Following the subsequent
rising-edge of the WDI/RESETB pin, the LTC2977 will
execute its power-on sequence per the user configuration
stored in EEPROM. Connect WDI/RESETB to VDD33 with
a 10k resistor. WDI/RESETB includes an internal 256µs
deglitch filter so additional filter capacitance on this pin
is not recommended.
Write-Protect Pin
The WP pin allows the user to write-protect the LTC2977’s
configuration registers. The WP pin is active high, and
when asserted it provides Level 2 protection: all writes
are disabled except to the WRITE_PROTECT, PAGE,
MFR_EE_UNLOCK, STORE_USER_ALL, OPERATION,
MFR_PAGE_FF_MASK and CLEAR_FAULTS commands.
The most restrictive setting between the WP pin and
WRITE_PROTECT command will override. For example
if WP = 1 and WRITE_PROTECT = 0x80, then the
WRITE_PROTECT command overrides, since it is the
most restrictive.
Other Operations
Clock Sharing
Multiple LTC PMBus devices can synchronize their clocks
in an application by connecting together the open-drain
AF = 8.65
2977f
For more information www.linear.com/LTC2977
17
LTC2977
Operation
SHARE_CLK input/outputs to a pull-up resistor as a wired
OR. In this case the fastest clock will take over and synchronize all LTC2977s.
SHARE_CLK can optionally be used to synchronize ON/
OFF dependency on VIN across multiple chips by setting
the Mfr_config_all_vin_share_enable bit of the MFR_
CONFIG_ALL_LTC2977 register. When configured this
way the chip will hold SHARE_CLK low when the unit is
off for insufficient input voltage and upon detecting that
SHARE_CLK is held low the chip will disable all channels
after a brief deglitch period. When the SHARE_CLK pin
is allowed to rise, the chip will respond by beginning a
soft-start sequence. In this case the slowest VIN_ON
detection will take over and synchronize other chips to
its soft-start sequence.
PMBus Serial Digital Interface
The LTC2977 communicates with a host (master) using the
standard PMBus serial bus interface. The PMBus Timing
Diagram shows the timing relationship of the signals on
the bus. The two bus lines, SDA and SCL, must be high
when the bus is not in use. External pull-up resistors or
current sources are required on these lines.
The LTC2977 is a slave device. The master can communicate with the LTC2977 using the following formats:
n
Master transmitter, slave receiver
n
Master receiver, slave transmitter
The LTC2977 will not acknowledge any PMBus command
other than MFR_COMMON if it is still busy with a STORE_
USER_ALL, RESTORE_USER_ALL, MFR_CONFIG_
LTC2977 or if fault log data is being written to the EEPROM.
Status_word_busy will be set when this happens.
PMBus
PMBus is an industry standard that defines a means
of communication with power conversion devices. It is
comprised of an industry standard SMBus serial interface
and the PMBus command language.
The PMBus two wire interface is an incremental extension
of the SMBus. SMBus is built upon I2C with some minor
differences in timing, DC parameters and protocol. The
SMBus protocols are more robust than simple I2C byte
commands because they provide timeouts to prevent
bus hangs and optional packet error checking (PEC) to
ensure data integrity. In general, a master device that
can be configured for I2C communication can be used
for PMBus communication with little or no change to
hardware or firmware.
For a description of the minor extensions and exceptions
PMBus makes to SMBus, refer to PMBus Specification
Part 1 Revision 1.1: paragraph 5: Transport. This can be
found at:
www.pmbus.org.
n
Write Byte, Write Word, Send Byte
For a description of the differences between SMBus and
I2C, refer to system management bus (SMBus) specification version 2.0: Appendix B – Differences Between SMBus
and I2C. This can be found at:
n
Read Byte, Read Word, Block Read
www.smbus.org.
n
Alert Response Address
The following SMBus protocols are supported:
Figures 1-12 illustrate the aforementioned SMBus
protocols. All transactions support PEC (parity error check)
and GCP (group command protocol). The Block Read
supports 255 bytes of returned data. For this reason, the
PMBus timeout may be extended using the Mfr_config_all_
longer_pmbus_timeout setting.
When using an I2C controller to communicate with a
PMBus part it is important that the controller be able to
write a byte of data without generating a stop. This will
allow the controller to properly form the repeated start
of the PMBus read command by concatenating a start
command byte write with an I2C read.
2977f
18
For more information www.linear.com/LTC2977
LTC2977
Operation
1
7
S
1
1
SLAVE ADDRESS Wr A COMMAND CODE A
x
x
1
1
8
P
S
Sr
Rd
Wr
x
START CONDITION
REPEATED START CONDITION
READ (BIT VALUE OF 1)
WRITE (BIT VALUE OF 0)
SHOWN UNDER A FIELD INDICATES THAT THE
FIELD IS REQUIRED TO HAVE THE VALUE OF x
A
ACKNOWLEDGE (THIS BIT POSITION MAY BE 0
FOR AN ACK OR 1 FOR A NACK)
P
STOP CONDITION
PEC PACKET ERROR CODE
MASTER TO SLAVE
SLAVE TO MASTER
...
CONTINUATION OF PROTOCOL
2977 F01a
Figure 1a. PMBus Packet Protocol Diagram Element Key
1
S
7
1
1
8
1
SLAVE ADDRESS Wr A COMMAND CODE A
8
1
1
DATA BYTE
A
P
2977 F01b
Figure 1b. Write Byte Protocol
1
S
7
1
1
8
1
SLAVE ADDRESS Wr A COMMAND CODE A
8
1
8
1
1
DATA BYTE LOW
A
DATA BYTE HIGH
A
P
2977 F02
Figure 2. Write Word Protocol
1
S
7
1
1
8
1
SLAVE ADDRESS Wr A COMMAND CODE A
8
1
8
1
1
DATA BYTE
A
PEC
A
P
2977 F03
Figure 3. Write Byte Protocol with PEC
1
S
7
1
1
8
1
SLAVE ADDRESS Wr A COMMAND CODE A
8
1
8
1
8
1
1
DATA BYTE LOW
A
DATA BYTE HIGH
A
PEC
A
P
2977 F04
Figure 4. Write Word Protocol with PEC
1
S
1
1
SLAVE ADDRESS Wr A COMMAND CODE A
7
1
1
8
P
2977 F05
Figure 5. Send Byte Protocol
1
S
7
1
1
8
1
SLAVE ADDRESS Wr A COMMAND CODE A
8
1
1
PEC
A
P
2977 F06
Figure 6. Send Byte Protocol with PEC
2977f
For more information www.linear.com/LTC2977
19
LTC2977
Operation
1
S
7
1
1
8
1
1
SLAVE ADDRESS Wr A COMMAND CODE A
7
1
1
Sr SLAVE ADDRESS Rd A
8
1
DATA BYTE LOW
A
1
1
DATA BYTE HIGH A
8
P
1 2977 F07
Figure 7. Read Word Protocol
1
S
7
1
1
8
1
1
7
1
1
SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A
8
1
DATA BYTE LOW
A
8
1
DATA BYTE HIGH A
8
1
1
PEC
A
P
1 2977 F08
Figure 8. Read Word Protocol with PEC
1
S
7
1
1
8
1
1
7
1
1
SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A
8
1
1
DATA BYTE
A
P
1 2977 F09
Figure 9. Read Byte Protocol
1
S
7
1
1
8
1
1
7
1
1
SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A
8
1
DATA BYTE
A
PEC
1
1
A
P
1 2977 F10
Figure 10. Read Byte Protocol with PEC
1
S
1
7
1
1
8
1
7
1
1
SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A
8
1
8
1
DATA BYTE 1
A
DATA BYTE 2
A
8
1
BYTE COUNT = N A
...
2977 F11
...
...
8
1
1
DATA BYTE N
A
P
1
Figure 11. Block Read
1
S
7
1
1
8
1
1
7
1
1
SLAVE ADDRESS Wr A COMMAND CODE A Sr SLAVE ADDRESS Rd A
8
1
8
1
DATA BYTE 1
A
DATA BYTE 2
A
...
...
8
1
BYTE COUNT = N A
...
2977 F12
8
1
8
1
1
DATA BYTE N
A
PEC
A
P
1
Figure 12. Block Read with PEC
2977f
20
For more information www.linear.com/LTC2977
LTC2977
Operation
Device Address
The I2C/SMBus address of the LTC2977 equals the base
address + N where N is a number from 0 to 8. N can be
configured by setting the ASEL0 and ASEL1 pins to VDD33,
GND or FLOAT. See Table 1. Using one base address and
the nine values of N, nine LTC2977s can be connected
together to control 72 outputs. The base address is stored
in the MFR_I2C_BASE_ADDRESS register. The base address can be written to any value, but generally should not
be changed unless the desired range of addresses overlap
existing addresses. Watch that the address range does not
overlap with other I2C/SMBus device or global addresses,
including I2C/SMBus multiplexers and bus buffers. This
will bring you great happiness.
The LTC2977 always responds to its global address and the
SMBus Alert Response address regardless of the state of
its ASEL pins and the MFR_I2C_BASE_ADDRESS register.
Table 1. LTC2977 Device Address Look-Up Table
ADDRESS
DESCRIPTION
HEX DEVICE
ADDRESS
BINARY DEVICE ADDRESS BITS
ADDRESS PINS
7-Bit
8-Bit
6
5
4
3
2
1
0
R/W
ASEL1
ASEL0
Alert Response
0C
19
0
0
0
1
1
0
0
1
X
X
Global
5B
B6
1
0
1
1
0
1
1
0
X
X
N=0
5C*
B8
1
0
1
1
1
0
0
0
L
L
N=1
5D
BA
1
0
1
1
1
0
1
0
L
NC
N=2
5E
BC
1
0
1
1
1
1
0
0
L
H
N=3
5F
BE
1
0
1
1
1
1
1
0
NC
L
N=4
60
C0
1
1
0
0
0
0
0
0
NC
NC
N=5
61
C2
1
1
0
0
0
0
1
0
NC
H
N=6
62
C4
1
1
0
0
0
1
0
0
H
L
N=7
63
C6
1
1
0
0
0
1
1
0
H
NC
N=8
64
C8
1
1
0
0
1
0
0
0
H
H
H = Tie to VDD33, NC = No Connect = Open or Float, L = Tie to GND, X = Don’t Care
*MFR_I2C_BASE_ADDRESS = 7bit 5C (Factory Default)
2977f
For more information www.linear.com/LTC2977
21
LTC2977
Operation
Processing Commands
The LTC2977 uses a dedicated processing block to ensure quick response to all of its commands. There are a few
exceptions where the part will NACK a subsequent command because it is still processing the previous command.
These are summarized in the following tables. MFR_COMMON is a special command that may always be read even
when the part is busy. This provides an alternate method for a host to determine if the LTC2977 is busy.
EEPROM Related Commands
COMMAND
STORE_USER_ALL
TYPICAL DELAY*
tMASS_WRITE
COMMENT
See Electrical Characteristics table. The LTC2977 will not accept any commands while it is transferring
register contents to the EEPROM. The command byte will be NACKed. MFR_COMMON may always be read.
RESTORE_USER_ALL
30ms
The LTC2977 will not accept any commands while it is transferring EEPROM data to command
registers. The command byte will be NACKed. MFR_COMMON may always be read.
MFR_FAULT_LOG_CLEAR
175ms
The LTC2977 will not accept any commands while it is initializing the fault log EEPROM space. The
command byte will be NACKed. MFR_COMMON may always be read.
MFR_FAULT_LOG_STORE
20ms
The LTC2977 will not accept any commands while it is transferring the fault log RAM buffer to EEPROM
space. The command byte will be NACKed. MFR_COMMON may always be read.
Internal Fault log
20ms
An internal fault log event is a one time event that uploads the contents of the fault log to EEPROM in
response to a fault. Internal fault logging may be disabled. Commands received during this EEPROM
write are NACKed. MFR_COMMON may always be read.
MFR_FAULT_LOG_
RESTORE
2ms
The LTC2977 will not accept any commands while it is transferring EEPROM data to the fault log RAM
buffer. The command byte will be NACKed. MFR_COMMON may always be read.
*The typical delay is measured from the command’s stop to the next command’s start.
COMMAND
MFR_CONFIG_LTC2977
TYPICAL DELAY*
COMMENT
<50µs
The LTC2977 will not accept any commands while it is completing this command. The command byte
will be NACKed. MFR_COMMON may always be read.
*The typical delay is measured from the command’s stop to the next command’s start.
Other PMBus Timing Notes
COMMAND
CLEAR_FAULTS
COMMENT
The LTC2977 will accept commands while it is completing this command but the affected status flags will not be cleared for
up to 500µs.
2977f
22
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Summary
Summary Table
COMMAND NAME
CMD
CODE DESCRIPTION
TYPE
DATA
PAGED FORMAT UNITS EEPROM
DEFAULT
VALUE
REF
PAGE
0x00
28
PAGE
0x00 Channel or page currently selected for any R/W Byte
command that supports paging.
N
Reg
OPERATION
0x01 Operating mode control. On/Off, Margin
High and Margin Low.
R/W Byte
Y
Reg
Y
0x00
33
ON_OFF_CONFIG
0x02 CONTROL pin & PMBus bus on/off
command setting.
R/W Byte
Y
Reg
Y
0x1E
34
CLEAR_FAULTS
0x03 Clear any fault bits that have been set.
Send Byte
Y
NA
34
WRITE_PROTECT
0x10 Level of protection provided by the device
against accidental changes.
R/W Byte
N
Reg
Y
0x00
28
STORE_USER_ALL
0x15 Store entire operating memory to
EEPROM.
Send Byte
N
NA
35
RESTORE_USER_ALL
0x16 Restore entire operating memory from
EEPROM.
Send Byte
N
NA
35
CAPABILITY
0x19 Summary of PMBus optional
communication protocols supported by
this device.
R Byte
N
Reg
0xB0
35
VOUT_MODE
0x20 Output voltage data format and mantissa
exponent. (2–13)
R Byte
Y
Reg
0x13
35
VOUT_COMMAND
0x21 Servo Target. Nominal DC/DC converter
output voltage setpoint.
R/W Word
Y
L16
V
Y
1.0
0x2000
36
VOUT_MAX
0x24 Upper limit on the output voltage the unit
can command regardless of any other
commands.
R/W Word
Y
L16
V
Y
4.0
0x8000
36
VOUT_MARGIN_HIGH
0x25 Margin high DC/DC converter output
voltage setting.
R/W Word
Y
L16
V
Y
1.05
0x219A
36
VOUT_MARGIN_LOW
0x26 Margin low DC/DC converter output
voltage setting.
R/W Word
Y
L16
V
Y
0.95
0x1E66
36
VIN_ON
0x35 Input voltage (VIN_SNS) above which
power conversion can be enabled.
R/W Word
N
L11
V
Y
10.0
0xD280
36
VIN_OFF
0x36 Input voltage (VIN_SNS) below which
R/W Word
power conversion is disabled. All VOUT_EN
pins go off immediately.
N
L11
V
Y
9.0
0xD240
36
VOUT_OV_FAULT_LIMIT
0x40 Output overvoltage fault limit
R/W Word
Y
L16
V
Y
1.1
0x2333
36
VOUT_OV_FAULT_
RESPONSE
0x41 Action to be taken by the device when an
output overvoltage fault is detected.
R/W Byte
Y
Reg
Y
0x80
38
VOUT_OV_WARN_LIMIT
0x42 Output overvoltage warning limit .
R/W Word
Y
L16
V
Y
1.075
0x2266
36
VOUT_UV_WARN_LIMIT
0x43 Output undervoltage warning limit
R/W Word
Y
L16
V
Y
0.925
0x1D9A
36
VOUT_UV_FAULT_LIMIT
0x44 Output undervoltage fault limit. Limit
used to determine if TON_MAX_FAULT
has been met and the unit is on.
R/W Word
Y
L16
V
Y
0.9
0x1CCD
36
VOUT_UV_FAULT_
RESPONSE
0x45 Action to be taken by the device when an
output undervoltage fault is detected.
R/W Byte
Y
Reg
Y
0x7F
38
OT_FAULT_LIMIT
0x4F Overtemperature fault limit.
R/W Word
N
L11
Y
105.0
0xEB48
37
OT_FAULT_RESPONSE
0x50 Action to be taken by the device when an
overtemperature fault is detected.
R/W Byte
N
Reg
Y
0xB8
39
°C
2977f
For more information www.linear.com/LTC2977
23
LTC2977
PMBus Command summary
Summary Table
COMMAND NAME
CMD
CODE DESCRIPTION
DEFAULT
VALUE
REF
PAGE
OT_WARN_LIMIT
0x51 Overtemperature warning limit.
R/W Word
N
L11
°C
Y
70.0
0xEA30
37
UT_WARN_LIMIT
0x52 Undertemperature warning limit.
R/W Word
N
L11
°C
Y
0
0x8000
37
UT_FAULT_LIMIT
0x53 Undertemperature fault limit.
R/W Word
N
L11
°C
Y
–40.0
0xE580
37
UT_FAULT_RESPONSE
0x54 Action to be taken by the device when an
undertemperature fault is detected.
R/W Byte
N
Reg
Y
0xB8
39
VIN_OV_FAULT_LIMIT
0x55 Input overvoltage fault limit measured at
VIN_SNS pin
R/W Word
N
L11
Y
15.0
0xD3C0
36
VIN_OV_FAULT_
RESPONSE
0x56 Action to be taken by the device when an
input overvoltage fault is detected.
R/W Byte
N
Reg
Y
0x80
39
VIN_OV_WARN_LIMIT
0x57 Input overvoltage warning limit measured R/W Word
at VIN_SNS pin
N
L11
V
Y
14.0
0xD380
36
VIN_UV_WARN_LIMIT
0x58 Input undervoltage warning limit
measured at VIN_SNS pin.
R/W Word
N
L11
V
Y
0
0x8000
36
VIN_UV_FAULT_LIMIT
0x59 Input undervoltage fault limit measured at R/W Word
VIN_SNS pin
N
L11
V
Y
0
0x8000
36
VIN_UV_FAULT_
RESPONSE
0x5A Action to be taken by the device when an
input undervoltage fault is detected.
R/W Byte
N
Reg
Y
0x00
39
POWER_GOOD_ON
0x5E Output voltage at or above which a power R/W Word
good should be asserted.
Y
L16
V
Y
0.96
0x1EB8
36
POWER_GOOD_OFF
0x5F Output voltage at or below which a power R/W Word
good should be deasserted.
Y
L16
V
Y
0.94
0x1E14
36
TON_DELAY
0x60 Time from CONTROL pin and/or
OPERATION command = ON to VOUT_EN
pin = ON.
R/W Word
Y
L11
ms
Y
1.0
0xBA00
37
TON_RISE
0x61 Time from when the VOUT_ENn pin goes
high until the LTC2977 optionally softconnects its DAC and begins to servo the
output voltage to the desired value.
R/W Word
Y
L11
ms
Y
10.0
0xD280
37
TON_MAX_FAULT_LIMIT
0x62 Maximum time from VOUT_EN = ON
assertion that an UV condition will be
tolerated before a TON_MAX_FAULT
condition results.
R/W Word
Y
L11
ms
Y
15.0
0xD3C0
37
TON_MAX_FAULT_
RESPONSE
0x63 Action to be taken by the device when a
TON_MAX_FAULT event is detected.
R/W Byte
Y
Reg
Y
0xB8
40
TOFF_DELAY
0x64 Time from CONTROL pin and/or
OPERATION command = OFF to VOUT_EN
pin = OFF.
R/W Word
Y
L11
Y
1.0
0xBA00
37
STATUS_BYTE
0x78 One byte summary of the unit’s fault
condition.
R Byte
Y
Reg
NA
41
STATUS_WORD
0x79 Two byte summary of the unit’s fault
condition.
R Word
Y
Reg
NA
41
STATUS_VOUT
0x7A Output voltage fault and warning status.
R Byte
Y
Reg
NA
42
STATUS_INPUT
0x7C Input voltage fault and warning status
measured at VIN_SNS pin.
R Byte
N
Reg
NA
42
STATUS_TEMPERATURE
0x7D Temperature fault and warning status for
READ_TEMPERATURE_1.
R Byte
N
Reg
NA
42
TYPE
DATA
PAGED FORMAT UNITS EEPROM
V
ms
2977f
24
For more information www.linear.com/LTC2977
LTC2977
PMBus Command summary
Summary Table
COMMAND NAME
CMD
CODE DESCRIPTION
TYPE
DATA
PAGED FORMAT UNITS EEPROM
DEFAULT
VALUE
REF
PAGE
STATUS_CML
0x7E Communication and memory fault and
warning status.
R Byte
N
Reg
NA
43
STATUS_MFR_SPECIFIC
0x80 Manufacturer specific fault and state
information.
R Byte
Y
Reg
NA
43
READ_VIN
0x88 Input voltage measured at VIN_SNS pin.
R Word
N
L11
V
NA
44
READ_VOUT
0x8B DC/DC converter output voltage.
R Word
Y
L16
V
NA
44
READ_TEMPERATURE_1
0x8D Internal junction temperature.
R Word
N
L11
°C
NA
44
PMBUS_REVISION
0x98 PMBus revision supported by this device.
Current revision is 1.1.
R Byte
N
Reg
0x11
44
USER_DATA_00
0xB0 Manufacturer reserved for LTpowerPlay™. R/W Word
N
Reg
Y
NA
60
USER_DATA_01
0xB1 Manufacturer reserved for LTpowerPlay.
R/W Word
Y
Reg
Y
NA
60
USER_DATA_02
0xB2 OEM reserved.
R/W Word
N
Reg
Y
NA
60
USER_DATA_03
0xB3 Scratchpad location.
R/W Word
Y
Reg
Y
0x00
60
USER_DATA_04
0xB4 Scratchpad location.
R/W Word
N
Reg
Y
0x00
60
MFR_LTC_RESERVED_1
0xB5 Manufacturer reserved.
R/W Word
Y
Reg
Y
NA
60
MFR_STATUS_2
0xB7 Additional manufacturer specific fault and
state information.
R Word
Y
Reg
NA
62
MFR_LTC_RESERVED_2
0xBC Manufacturer reserved.
R/W Word
Y
Reg
NA
60
MFR_EE_UNLOCK
0xBD Unlock user EEPROM for access by
MFR_EE_ERASE and MFR_EE_DATA
commands.
R/W Byte
N
Reg
NA
65
MFR_EE_ERASE
0xBE Initialize user EEPROM for bulk
programming by MFR_EE_DATA.
R/W Byte
N
Reg
NA
66
MFR_EE_DATA
0xBF Data transferred to and from EEPROM
using sequential PMBus word reads or
writes. Supports bulk programming.
R/W Word
N
Reg
NA
66
MFR_COMMAND_PLUS
0xC0 Alternate access to block read and other
data: commands for all hosts.
R/W Word
N
Reg
NA
30
MFR_DATA_PLUS0
0xC1 Alternate access to block read and other
data: data for alternate host 0.
R/W Word
N
Reg
NA
30
MFR_DATA_PLUS1
0xC2 Alternate access to block read an other
data: data for alternate host 1.
R/W Word
N
Reg
NA
30
MFR_TELEMETRY
0xCF Telemetry data for all output channels.
R Block
N
Reg
NA
63
MFR_CONFIG_LTC2977
0xD0 Configuration bits that are channel
specific.
R/W Word
Y
Reg
Y
0x0080
45
MFR_CONFIG_ALL_
LTC2977
0xD1 Configuration bits that are common to all
pages.
R/W Word
N
Reg
Y
0x1C7B
49
MFR_FAULTBz0_
PROPAGATE
0xD2 Configuration that determines if a
channel’s faulted off state is propagated
to the FAULTB00 and FAULTB10 pins.
R/W Byte
Y
Reg
Y
0x00
50
MFR_FAULTBz1_
PROPAGATE
0xD3 Manufacturer configuration that
Configuration that determines if a
channel’s faulted off state is propagated
to the FAULTB01 and FAULTB11 pins.
R/W Byte
Y
Reg
Y
0x00
50
MFR_PWRGD_EN
0xD4 Configuration for mapping PWRGD and
WDI/RESETB status to the PWRGD pin.
R/W Word
N
Reg
Y
0x0000
51
2977f
For more information www.linear.com/LTC2977
25
LTC2977
PMBus Command summary
Summary Table
COMMAND NAME
CMD
CODE DESCRIPTION
DEFAULT
VALUE
REF
PAGE
MFR_FAULTB00_
RESPONSE
0xD5 Action to be taken by the device when the
FAULTB00 pin is asserted low.
R/W Byte
N
Reg
Y
0x00
52
MFR_FAULTB01_
RESPONSE
0xD6 Action to be taken by the device when the
FAULTB01 pin is asserted low.
R/W Byte
N
Reg
Y
0x00
52
MFR_FAULTB10_
RESPONSE
0xD7 Action to be taken by the device when the
FAULTB10 pin is asserted low.
R/W Byte
N
Reg
Y
0x00
52
MFR_FAULTB11_
RESPONSE
0xD8 Action to be taken by the device when the
FAULTB11 pin is asserted low.
R/W Byte
N
Reg
Y
0x00
52
MFR_VINEN_OV_FAULT_
RESPONSE
0xD9 Action to be taken by the VIN_EN pin in
response to a VOUT_OV_FAULT
R/W Byte
N
Reg
Y
0x00
53
MFR_VINEN_UV_FAULT_
RESPONSE
0xDA Action to be taken by the VIN_EN pin in
response to a VOUT_UV_FAULT
R/W Byte
N
Reg
Y
0x00
54
MFR_RETRY_DELAY
0xDB Retry interval during FAULT retry mode.
R/W Word
N
L11
ms
Y
200.0
0xF320
55
MFR_RESTART_DELAY
0xDC Delay from actual CONTROL active edge
to virtual CONTROL active edge.
R/W Word
N
L11
ms
Y
400.0
0xFB20
55
MFR_VOUT_PEAK
0xDD Maximum measured value of READ_
VOUT.
R Word
Y
L16
V
NA
56
MFR_VIN_PEAK
0xDE Maximum measured value of READ_VIN.
R Word
N
L11
V
NA
56
MFR_TEMPERATURE_
PEAK
0xDF Maximum measured value of READ_
TEMPERATURE_1.
R Word
N
L11
°C
NA
56
MFR_DAC
0xE0 Manufacturer register that contains the
code of the 10-bit DAC.
R/W Word
Y
Reg
0x0000
57
MFR_POWERGOOD_
ASSERTION_DELAY
0xE1 Power good output assertion delay.
R/W Word
N
L11
ms
Y
100.0
0xEB20
57
MFR_WATCHDOG_T_FIRST 0xE2 First watchdog timer interval.
R/W Word
N
L11
ms
Y
0
0x8000
64
MFR_WATCHDOG_T
0xE3 Watchdog timer interval.
R/W Word
N
L11
ms
Y
0
0x8000
64
MFR_PAGE_FF_MASK
0xE4 Configuration defining which channels
respond to global page commands
(PAGE=0xFF).
R/W Byte
N
Reg
Y
0xFF
29
MFR_PADS
0xE5 Current state of selected digital I/O pads.
R Word
N
Reg
N/A
58
MFR_I2C_BASE_ADDRESS
0xE6 Base value of the I2C/SMBus address
byte.
R/W Byte
N
Reg
Y
0x5C
29
MFR_SPECIAL_ID
0xE7 Manufacturer code for identifying the
LTC2977
R Word
N
Reg
Y
0x0130
59
MFR_SPECIAL_LOT
0xE8 Customer dependent codes that
identify the factory programmed user
configuration stored in EEPROM. Contact
factory for default value.
R Byte
Y
Reg
Y
MFR_VOUT_DISCHARGE_
THRESHOLD
R/W Word
0xE9 Coefficient used to multiply VOUT_
COMMAND in order to determine VOUT off
threshold voltage.
Y
L11
Y
MFR_FAULT_LOG_STORE
0xEA Command a transfer of the fault log from
RAM to EEPROM. This causes the part to
behave as if a channel has faulted off.
N
TYPE
Send Byte
DATA
PAGED FORMAT UNITS EEPROM
59
2.0
0xC200
59
NA
67
2977f
26
For more information www.linear.com/LTC2977
LTC2977
PMBus Command summary
Summary Table
CMD
CODE DESCRIPTION
COMMAND NAME
TYPE
DATA
PAGED FORMAT UNITS EEPROM
DEFAULT
VALUE
REF
PAGE
MFR_FAULT_LOG_
RESTORE
0xEB Command a transfer of the fault log
previously stored in EEPROM back to
RAM.
Send Byte
N
NA
67
MFR_FAULT_LOG_CLEAR
0xEC Initialize the EEPROM block reserved for
fault logging and clear any previous fault
logging locks.
Send Byte
N
NA
68
MFR_FAULT_LOG_STATUS
0xED Fault logging status.
R Byte
N
Reg
Y
NA
68
MFR_FAULT_LOG
0xEE Fault log data bytes. This sequentially
retrieved data is used to assemble a
complete fault log. 256 Bytes: 0xFF
followed by 255 bytes of fault log data.
R Block
N
Reg
Y
NA
69
MFR_COMMON
0xEF Manufacturer status bits that are common
across multiple LTC chips.
R Byte
N
Reg
NA
60
MFR_RETRY_COUNT
0xF7 Retry count for all faulted off conditions
that enable retry.
R/W Byte
N
Reg
0x07
55
MFR_VOUT_MIN
0xFB Minimum measured value of READ_
VOUT.
R Word
Y
L16
V
NA
61
MFR_VIN_MIN
0xFC Minimum measured value of READ_VIN.
R Word
N
L11
V
NA
61
MFR_TEMPERATURE_MIN
0xFD Minimum measured value of READ_
TEMPERATURE_1.
R Word
N
L11
°C
NA
61
Y
Data Formats
L11
Linear_5s_11s
L16
Linear_16u
Reg
Register
PMBus data field b[15:0]
Value = Y • 2N
where N = b[15:11] is a 5-bit two’s complement integer and Y = b[10:0] is an 11-bit two’s complement integer
Example:
READ_VIN = 10V
For b[15:0] = 0xD280 = 1101_0010_1000_0000b
Value = 640 • 2–6 = 10
See PMBus Spec Part II: Paragraph 7.1
PMBus data field b[15:0]
Value = Y • 2N where Y = b[15:0] is an unsigned integer and N = Vout_mode_parameter is a 5-bit two’s complement
exponent that is hardwired to –13 decimal.
Example:
VOUT_COMMAND = 4.75V
For b[15:0] = 0x9800 = 1001_1000_0000_0000b
Value = 38912 • 2–13 = 4.75
See PMBus Spec Part II: Paragraph 8.3.1
PMBus data field b[15:0] or b[7:0].
Bit field meaning is defined in detailed PMBus Command Register Description.
2977f
For more information www.linear.com/LTC2977
27
LTC2977
PMBus Command Description
Addressing and Write Protect
PAGE
The LTC2977 has eight pages that correspond to the eight DC/DC converter channels that can be managed. Each DC/DC
converter channel can be uniquely programmed by first setting the appropriate page.
Setting PAGE = 0xFF allows a simultaneous write to all pages for PMBus commands that support global page
programming. The only commands that support PAGE = 0xFF are CLEAR_FAULTS, OPERATION and ON_OFF_CONFIG.
See MFR_PAGE_FF_MASK for additional options. Reading any paged PMBus register with PAGE = 0xFF returns unpredictable data and will trigger a CML fault. Writes to pages that do not support PAGE = 0xFF with PAGE = 0xFF will
be ignored and generate a CML fault.
PAGE Data Contents
BIT(S) SYMBOL PURPOSE
b[7:0] Page Page operation.
0x00: All PMBus commands address channel/page 0.
0x01: All PMBus commands address channel/page 1.
•
•
•
0x07: All PMBus commands address channel/page 7.
0xXX: All nonspecified values reserved.
0xFF: A single PMBus write/send to commands that support this mode will simultaneously address all channels/pages with
MFR_PAGE_FF_MASK enabled.
WRITE_PROTECT
The WRITE_PROTECT command provides protection against accidental programming of the LTC2977 command
registers. All supported commands may have their parameters read, regardless of the WRITE_PROTECT setting, and
the EEPROM contents can also be read regardless of the WRITE_PROTECT settings.
There are two levels of write protection:
• Level 1: Nothing can be changed except the level of write protection itself. Values can be read from all pages. This
setting can be stored to EEPROM.
• Level 2: Nothing can be changed except for the level of protection, channel on/off state and clearing of faults. Values
can be read from all pages. This setting can be stored to EEPROM.
WRITE_PROTECT Data Contents
BITS(S) SYMBOL
b[7:0]
Write_protect[7:0]
OPERATION
1000_0000b: Level 1 Protection - Disable all writes except to the WRITE_PROTECT, PAGE, MFR_EE_UNLOCK, and
STORE_USER_ALL commands.
0100_0000b: Level 2 Protection – Disable all writes except to the WRITE_PROTECT, PAGE, MFR_EE_UNLOCK, STORE_
USER_ALL, OPERATION, MFR_PAGE_FF_MASK and CLEAR_FAULTS commands.
0000_0000b: Enable writes to all commands.
xxxx_xxxxb: All other values reserved.
2977f
28
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_PAGE_FF_MASK
The MFR_PAGE_FF_MASK command is used to select which channels respond when the global page command
(PAGE=0xFF) is in use.
MFR_PAGE_FF_MASK Data Contents
BIT(S) SYMBOL
b[7]
OPERATION
Mfr_page_ff_mask_chan7
Channel 7 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
b[6]
Mfr_page_ff_mask_chan6
Channel 6 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
b[5]
Mfr_page_ff_mask_chan5
Channel 5 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
b[4]
Mfr_page_ff_mask_chan4
Channel 4 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
b[3]
Mfr_page_ff_mask_chan3
Channel 3 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
b[2]
Mfr_page_ff_mask_chan2
Channel 2 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
b[1]
Mfr_page_ff_mask_chan1
Channel 1 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
b[0]
Mfr_page_ff_mask_chan0
Channel 0 masking of global page command (PAGE=0xFF) accesses
0 = ignore global page command accesses
1 = fully respond to global page command accesses
MFR_I2C_BASE_ADDRESS
The MFR_I2C_BASE_ADDRESS command determines the base value for the I2C/SMBus address byte. Offsets of 0
to 9 are added to this base address to make the device I2C/SMBus address. The part responds to the device address.
MFR_I2C_BASE_ADDRESS Data Contents
BIT(S) SYMBOL
b[7]
Reserved
b[6:0] i2c_base_address
OPERATION
Read only, always returns 0.
This 7-bit value determines the base value of the 7-bit I2C/SMBus address. See Operation Section: Device Address.
2977f
For more information www.linear.com/LTC2977
29
LTC2977
PMBus Command Description
MFR_COMMAND_PLUS, MFR_DATA_PLUS0, MFR_DATA_PLUS1, MFR_STATUS_PLUS0, and MFR_STATUS_PLUS1
Command Plus operations use a sequence of word commands to support the following:
• An alternate method for reading block data using sequential standard word reads.
• A peek operation that allows up to two additional hosts to read an internal register using PMBus word protocol
where each host has a unique page.
• A poke operation that allows up to two additional hosts to write an internal register using PMBus word protocol
where each host has a unique page.
• Peek, Poke and Command Plus block reads do not interfere with normal PMBus accesses or page values set by
PAGE. This enables multi master support for up to 3 hosts.
MFR_COMMAND_PLUS Data Contents
BIT(S)
SYMBOL
OPERATION
b[15]
Mfr_command_plus_
reserved
Reserved. Always returns 0.
b[14]
Mfr_command_plus_id
Command Plus host ID
0: Mfr_command_plus pointer and page are cached and used for all Mfr_data_plus0 accesses.
1: Mfr_command_plus pointer and page are cached and used for all Mfr_data_plus1 accesses.
b[13:9]
Mfr_command_plus_page
Page to be used when peeking or poking via Mfr_data_plus0 or Mfr_data_plus1. Allowed values are 0
through 7. This page value is cached separately for Mfr_data_plus0 and Mfr_data_plus1 based on the value of
Mfr_command_plus_id when this register is written.
b[8:0]
Mfr_command_plus_pointer Internal memory location accessed by Mfr_data_plus0 or Mfr_data_plus1. Mfr_data_plus0 and Mfr_data_plus1
pointers are cached separately. Legal values are listed in the Cmd Code column of the PMBus COMMAND
SUMMARY table. All other values are reserved, except for the special poke enable/disable values listed in
Enabling and Disabling Poke Operations on page 32, and the command values listed below for Mfr_status_plus0
and Mfr_status_plus1.
MFR_DATA_PLUS0 and MFR_DATA_PLUS1 Data Contents
BIT(S)
b[15:0]
SYMBOL
OPERATION
Mfr_data_plus0
A read from this register returns data referenced by the last matching Mfr_command_plus write. More
specifically, writes to Mfr_command_plus by host 0 update Mfr_data_plus0, and writes to Mfr_command_plus
by host1 update Mfr_data_plus1. Multiple sequential reads while pointer=MFR_FAULT_LOG return the complete
contents of the block read buffer. Block reads beyond the end of the buffer return zeros.
Mfr_data_plus1
A write to this register will transfer the data to the location referenced by the last matching Mfr_command_
plus_pointer when the Poke operation protocol described in Poke Operation Using Mfr_data_plus0 on page 32
is followed.
2977f
30
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_STATUS_PLUS0 and MFR_STATUS_PLUS1 Data Contents
BIT(S)
SYMBOL
b[7:2]
Reserved
b[1]
b[0]
OPERATION
Mfr_status_plus_block_
peek_failed0
Status of most recent block peek for matching host.
Mfr_status_plus_block_
peek_failed1
1: Last block peek was aborted due to an intervening fault log EEPROM write, MFR_FAULT_LOG_STORE
command, or standard PMBus block read of MFR_FAULT_LOG. The intervening operation is always completed
cleanly.
0: Last block peek was not aborted.
Mfr_status_plus_poke_
failed0
Status of most recent poke for matching host.
Mfr_status_plus_poke_
failed1
1: Last poke operation failed because pokes were not enabled as described in Enabling and Disabling Poke
Operations below.
0: Last poke operation did not fail.
MFR_STATUS_PLUS0 is at command location 0x2C, and MFR_STATUS_PLUS1 is at command location 0x2D. These correspond to reserved PMBus
command locations. These two status registers can only be read via Command Plus peeks.
Reading Fault Log Using Command Plus and Mfr_data_plus0
Write Mfr_command_plus_pointer=0xEE with Mfr_command_plus_page=0 and Mfr_command_plus_id=0.
Read data from Mfr_data_plus0; each read returns the next data word of the MFR_FAULT_LOG command:
• The first word read is Byte_count[15:0]=0x00FF.
• The next set of words read is the Preamble with 2 bytes packed into a word. Refer to Fault Log section for details.
• The next set of words read is the Cyclical Loop Data with 2 bytes per word. Refer to Fault Log section for details.
• Extra reads return zero.
• Interleaved PMBus word and byte commands do not interfere with an ongoing Command Plus block read.
• Interleaved PMBus block reads of MFR_FAULT_LOG will interrupt this command.
Check status to be sure the data just read was all valid:
• Write Mfr_command_plus_pointer=0x2C with Mfr_command_plus_page=0 and Mfr_command_plus_id=0.
• Read data from Mfr_data_plus0 and confirm that Mfr_status_plus_block_peek_failed0 = 0.
2977f
For more information www.linear.com/LTC2977
31
LTC2977
PMBus Command Description
Peek Operation using Mfr_data_plus0
Internal words and bytes may be read using Command Plus:
Write Mfr_command_plus_pointer=CMD_CODE with Mfr_command_plus_page=page and Mfr_command_plus_id=0.
The CMD_CODE’s are listed in the PMBus COMMAND SUMMARY table.
Read data from Mfr_data_plus0. Data is always read using a word read. Byte data is returned with the upper byte set to 0.
Enabling and Disabling Poke Operations
Poke operations to Mfr_data_plus0 are enabled by writing Mfr_command_plus = 0x0BF6.
Poke operations to Mfr_data_plus0 are disabled by writing Mfr_command_plus = 0x01F6.
Poke operations to Mfr_data_plus1 are enabled by writing Mfr_command_plus = 0x4BF6.
Poke operations to Mfr_data_plus1 are disabled by writing Mfr_command_plus = 0x41F6.
Poke Operation Using Mfr_data_plus0
Internal words and bytes may be written using Command Plus:
Enable poke access for Mfr_data_plus0. This need only be done once after a power-up or WDI reset.
Write Mfr_command_plus_pointer=CMD_CODE with Mfr_command_plus_page=page and Mfr_command_plus_id=0.
The CMD_CODE’s are listed in the PMBus COMMAND SUMMARY table.
Write the new data value to Mfr_data_plus0
Optionally check status to be sure data was written as desired:
• Write Mfr_command_plus_pointer=0x2C with Mfr_command_plus_page=0 and Mfr_command_plus_id=0.
• Read data from Mfr_data_plus0 and confirm that Mfr_status_plus_poke_failed0 = 0.
Command Plus Operations Using Mfr_data_plus1
All the previous operations may be accessed via Mfr_data_plus1 by substituting Mfr_command_plus_id value with
a 1. Poke operations must be enabled for Mfr_data_plus1.
2977f
32
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
Operation, Mode and EEPROM Commands
OPERATION
The OPERATION command is used to turn the unit on and off in conjunction with the CONTROLn pin and ON_OFF_
CONFIG. This command register responds to the global page command (PAGE=0xFF). The contents and functions of
the data byte are shown in the following tables. A minimum tOFF_MIN wait time must be observed between OPERATION
commands used to turn the unit off and then back on.
OPERATION Data Contents (On_off_config_use_pmbus=1)
SYMBOL
Action
BITS
Turn off immediately
Operation_control[1:0]
Operation_margin[1:0]
Operation_fault[1:0]
Reserved (read only)
b[7:6]
b[5:4]
b[3:2]
b[1:0]
00
XX
XX
00
Turn on
10
00
XX
00
Margin Low (Ignore Faults and
Warnings)
10
01
01
00
Margin Low
10
01
10
00
Margin High (Ignore Faults and
Warnings
10
10
01
00
10
10
10
00
01
00
XX
00
Sequence off and Margin Low
(Ignore Faults and Warnings)
01
01
01
00
Sequence off and Margin Low
01
01
10
00
Sequence off and Margin High
(Ignore Faults and Warnings)
01
10
01
00
Sequence off and Margin High
01
10
10
00
Margin High
FUNCTION Sequence off and margin to
nominal
Reserved
All remaining combinations
OPERATION Data Contents (On_off_config_use_pmbus=0)
SYMBOL
Action
Operation_control[1:0]
Operation_margin[1:0]
Operation_fault[1:0]
Reserved (read only)
b[7:6]
b[5:4]
b[3:2]
b[1:0]
Output at Nominal
00, 01 or 10
00
XX
00
Margin Low (Ignore faults and
Warnings)
00, 01 or 10
01
01
00
BITS
FUNCTION
Margin Low
00, 01 or 10
01
10
00
Margin High (Ignore Faults and
Warnings
00, 01 or 10
10
01
00
Margin High
00, 01 or 10
10
10
00
Reserved
All remaining combinations
2977f
For more information www.linear.com/LTC2977
33
LTC2977
PMBus Command Description
ON_OFF_CONFIG
The ON_OFF_CONFIG command configures the combination of CONTROLn pin input and PMBus bus commands needed
to turn the LTC2977 on/off, including the power-on behavior, as shown in the following table. This command register
responds to the global page command (PAGE=0xFF). After the part has initialized, an additional comparator monitors
VIN_SNS. The VIN_ON threshold must be exceeded before the output power sequencing can begin. After VIN is initially
applied, the part will typically require tINIT time to initialize and begin the TON_DELAY timer. The readback of voltages
and currents may require an additional wait for tUPDATE_ADC. A minimum tOFF_MIN wait time must be observed for any
CONTROL pin toggle used to turn the unit off and then back on.
ON_OFF_CONFIG Data Contents
BITS(S)
SYMBOL
OPERATION
b[7:5]
Reserved
Don’t care. Always returns 0.
b[4]
On_off_config_controlled_on
Controls default autonomous power-up operation.
0: Unit powers up regardless of the CONTROLn pin or OPERATION value. Unit always powers up with
sequencing. To turn unit on without sequencing, set TON_DELAY = 0.
1: Unit does not power up unless commanded by the CONTROLn pin and/or the OPERATION command
on the serial bus. If On_off_config[3:2] = 00, the unit never powers up.
b[3]
On_off_config_use_pmbus
Controls how the unit responds to commands received via the serial bus.
0: Unit ignores the Operation_control[1:0] bits.
1: Unit responds to Operation_control[1:0]. Depending on On_off_config_use_control, the unit may also
require the CONTROLn pin to be asserted for the unit to start.
b[2]
On_off_config_use_control
Controls how unit responds to the CONTROLn pin.
0: Unit ignores the CONTROLn pin.
1: Unit requires the CONTROLn pin to be asserted to start the unit. Depending on On_off_config_use_
pmbus the OPERATION command may also be required to instruct the device to start.
b[1]
Reserved
Not supported. Always returns 1.
b[0]
On_off_config_control_fast_off
CONTROLn pin turn off action when commanding the unit to turn off
0: Use the programmed TOFF_DELAY.
1: Turn off the output and stop transferring energy as quickly as possible, i.e. pull VOUT_ENn low
immediately. The device does not sink current in order to decrease the output voltage fall time.
CLEAR_FAULTS
The CLEAR_FAULTS command is used to clear any status bits that have been set. This command clears all fault and
warning bits in all unpaged status registers, and the paged status registers selected by the current PAGE setting. At
the same time, the device negates (clears, releases) its contribution to ALERTB.
The CLEAR_FAULTS command does not cause a unit that has latched off for a fault condition to restart. See Clearing
Latched Faults for more information.
If the fault condition is present after the fault status is cleared, the fault status bit shall be set again and the host notified by the usual means.
Note: This command responds to the global page command (PAGE=0xFF).
2977f
34
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
STORE_USER_ALL and RESTORE_USER_ALL
STORE_USER_ALL, RESTORE_USER_ALL commands provide access to User EEPROM space. Once a command is
stored in User EEPROM, it will be restored with an explicit restore command or when the part emerges from power-on
reset after power is applied. While either of these commands is being processed, the device will indicate it is busy, see
Response When Part Is Busy on page 67.
STORE_USER_ALL. Issuing this command will store all operating memory commands with a corresponding EEPROM memory location.
RESTORE_USER_ALL. Issuing this command will restore all commands from EEPROM Memory. It is recommended
that this command not be executed while a unit is enabled since all monitoring is suspended while the EEPROM is
transferred to operating memory, and intermediate values from EEPROM may not be compatible with the values initially
stored in operating memory.
CAPABILITY
The CAPABILITY command provides a way for a host system to determine some key capabilities of the LTC2977. This
one byte command is read only.
CAPABILITY Data Contents
BITS(S) SYMBOL
b[7]
b[6:5]
b[4]
b[3:0]
OPERATION
Capability_pec
Hard coded to 1 indicating Packet Error Checking is supported. Reading the Mfr_config_all_pec_en bit will indicate
whether PEC is currently required.
Capability_scl_max
Hard coded to 01b indicating the maximum supported bus speed is 400kHz.
Capability_smb_alert
Hard coded to 1 indicating this device does have an ALERTB pin and does support the SMBus Alert Response
Protocol.
Reserved
Always returns 0.
VOUT_MODE
This command is read only and specifies the mode and exponent for all commands with an L16 data format. See Data
Formats table on page 27.
VOUT_MODE Data Contents
BIT(S) SYMBOL
OPERATION
b[7:5]
Vout_mode_type
Reports linear mode. Hard wired to 000b.
b[4:0]
Vout_mode_parameter Linear mode exponent. 5-bit two’s complement integer. Hardwired to 0x13 (–13 decimal).
2977f
For more information www.linear.com/LTC2977
35
LTC2977
PMBus Command Description
Output Voltage Related Commands
VOUT_COMMAND, VOUT_MAX, VOUT_MARGIN_HIGH, VOUT_MARGIN_LOW, VOUT_OV_FAULT_LIMIT, VOUT_
OV_WARN_LIMIT, VOUT_UV_WARN_LIMIT, VOUT_UV_FAULT_LIMIT, POWER_GOOD_ON and POWER_GOOD_OFF
These commands use the same format and provide various servo, margining, and supervising limits for a channel’s
output voltage. When odd channels are configured to measure current, the OV_WARN_LIMIT, UV_WARN_LIMIT,
OV_FAULT_LIMIT and UV_FAULT_LIMIT commands are not supported.
Data Contents
BIT(S)
SYMBOL
b[15:0] Vout_command[15:0],
Vout_max[15:0],
OPERATION
These commands relate to output voltage. The data uses the L16 format.
Units: V
Vout_margin_high[15:0],
Vout_margin_low[15:0],
Vout_ov_fault_limit[15:0],
Vout_ov_warn_limit[15:0],
Vout_uv_warn_limit[15:0],
Vout_uv_fault_limit[15:0],
Power_good_on[15:0],
Power_good_off[15:0]
Input Voltage Related Commands
VIN_ON, VIN_OFF, VIN_OV_FAULT_LIMIT, VIN_OV_WARN_LIMIT, VIN_UV_WARN_LIMIT and VIN_UV_FAULT_
LIMIT
These commands use the same format and provide voltage supervising limits for the input voltage VIN_SNS.
Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Vin_on[15:0],
These commands relate to input voltage. The data uses the L11 format.
Vin_off[15:0],
Units: V.
Vin_ov_fault_limit[15:0],
Vin_ov_warn_limit[15:0],
Vin_uv_warn_limit[15:0],
Vin_uv_fault_limit[15:0]
2977f
36
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
Temperature Related Commands
OT_FAULT_LIMIT, OT_WARN_LIMIT, UT_WARN_LIMIT and UT_FAULT_LIMIT
These commands provide supervising limits for temperature.
Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Ot_fault_limit[15:0],
The data uses the L11 format.
Ot_warn_limit[15:0],
Units: °C.
Ut_warn_limit[15:0],
Ut_fault_limit[15:0]
Timer Limits
TON_DELAY, TON_RISE, TON_MAX_FAULT_LIMIT and TOFF_DELAY
These commands share the same format and provide sequencing and timer fault and warning delays in ms.
TON_DELAY sets the amount of time in milliseconds that a channel waits following the start of an ON sequence before
its VOUT_EN pin enables a DC/DC converter. This delay is counted using SHARE_CLK only.
TON_RISE sets the amount of time in ms that elapses after the power supply has been enabled until the LTC2977’s
DAC soft-connects and servos the output voltage to the desired level if Mfr_config_dac_mode = 00b. This delay is
counted using SHARE_CLK if available, otherwise the internal oscillator is used.
TON_MAX_FAULT_LIMIT is the maximum amount of time that the power supply being controlled by the LTC2977
can attempt to power up the output without reaching the VOUT_UV_FAULT_LIMIT. If the output reaches VOUT_UV_
FAULT_LIMIT prior to TON_MAX_FAULT_LIMIT, the LTC2977 unmasks the VOUT_UV_FAULT_LIMIT threshold. If it
does not, then a TON_MAX_FAULT is declared. (Note that a value of zero means there is no limit to how long the power
supply can attempt to bring up its output voltage.) This delay is counted using SHARE_CLK if available, otherwise the
internal oscillator is used.
TOFF_DELAY is the amount of time that elapses after the CONTROLn pin and/or OPERATION command is deasserted
until the channel is disabled (soft-off). This delay is counted using SHARE_CLK if available, otherwise the internal
oscillator is used.
TON_DELAY and TOFF_DELAY are internally limited to 13.1 seconds, and rounded to the nearest 10µs when smaller
than 655ms, or rounded to the nearest 200µs when larger than 655ms. TON_RISE and TON_MAX_FAULT_LIMIT are
internally limited to 655ms, and rounded to the nearest 10µs. The read value of these commands always returns what
was last written and does not reflect internal limiting.
Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Ton_delay[15:0],
The data uses the L11 format.
Ton_rise[15:0],
Units: ms.
Ton_max_fault[15:0],
Toff_delay[15:0]
2977f
For more information www.linear.com/LTC2977
37
LTC2977
PMBus Command Description
Fault Response for Voltages Measured by the High Speed Supervisor
VOUT_OV_FAULT_RESPONSE and VOUT_UV_FAULT_RESPONSE
The fault response documented here is for voltages that are measured by the high speed supervisor. These voltages
are measured over a short period of time and may require a deglitch period. Note that in addition to the response
described by these commands, the LTC2977 will also:
• Set the appropriate bit(s) in the STATUS_BYTE
• Set the appropriate bit(s) in the STATUS_WORD
• Set the appropriate bit in the corresponding STATUS_VOUT register, and
• Notify the host by pulling the ALERTB pin low.
Note: Odd numbered channels configured for high resolution ADC measurements (current measurements) will not
respond to OV/UV faults or warnings.
Data Contents
BIT(S) SYMBOL
OPERATION
b[7:6] Vout_ov_fault_response_action,
Response action:
Vout_uv_fault_response_action
00b: The unit continues operation without interruption.
01b: The unit continues operating for the delay time specified by bits[2:0] in increments of ts_vs. (See
Electrical Characteristics Table, Voltage Supervisor Characteristics section).
If the fault is still present at the end of the delay time, the unit shuts down immediately or sequences off after
TOFF_DELAY (See Mfr_config_chan_mode). After shutting down, the device responds according to the retry
setting in bits [5:3].
1Xb: The unit shuts down immediately or sequences off after TOFF_DELAY (See Mfr_config_chan_mode).
After shutting down, the device responds according to the retry setting in bits [5:3].
b[5:3] Vout_ov_fault_response_retry,
Vout_uv_fault_response_retry
Response retry behavior:
000b: A zero value for the retry setting means that the unit does not attempt to restart. The output remains
disabled until the fault is cleared.
001b-111b: The PMBus device attempts to restart the number of times specified by the global Mfr_retry_
count[2:0], until it is commanded OFF (by the CONTROL pin or OPERATION command or both), bias power
is removed, or another fault condition causes the unit to shut down.
b[2:0] Vout_ov_fault_response_delay,
Vout_uv_fault_response_delay
This sample count determines the amount of time a unit is to ignore a fault after it is first detected. Use this
delay to deglitch fast faults.
000b: The unit turns off immediately.
001b-111b: The unit turns off after b[2:0] samples at the sampling period of ts_vs (12.2µs typical).
2977f
38
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
Fault Response for Values Measured by the ADC
OT_FAULT_RESPONSE, UT_FAULT_RESPONSE, VIN_OV_FAULT_RESPONSE and VIN_UV_FAULT_RESPONSE
The fault response documented here is for values that are measured by the ADC. These values are measured over a
longer period of time and are not deglitched. Note that in addition to the response described by these commands, the
LTC2977 will also:
• Set the appropriate bit(s) in the STATUS_BYTE
• Set the appropriate bit(s) in the STATUS_WORD
• Set the appropriate bit in the corresponding STATUS_VIN or STATUS_TEMPERATURE register, and
• Notify the host by pulling the ALERTB pin low.
Data Contents
BIT(S) SYMBOL
OPERATION
b[7:6] Ot_fault_response_action,
Response action:
Ut_fault_response_action,
00b: The unit continues operation without interruption.
Vin_ov_fault_response_action,
01b to 11b: The unit shuts down immediately or sequences off after TOFF_DELAY (See Mfr_config_chan_
mode). After shutting down, the unit responds according to the retry setting in bits [5:3].
Vin_uv_fault_response_action
b[5:3] Ot_fault_response_retry,
Ut_fault_response_retry,
Vin_ov_fault_response_retry,
Vin_uv_fault_response_retry
b[2:0] Ot_fault_response_delay,
Response retry behavior:
000b: A zero value for the retry setting means that the unit does not attempt to restart. The output remains
disabled until the fault is cleared.
001b-111b: The PMBus device attempts to restart the number of times specified by the global Mfr_retry_
count[2:0] until it is commanded OFF (by the CONTROLn pin or OPERATION command or both), bias power is
removed, or another fault condition causes the unit to shut down.
Hard coded to 000b. There is no additional deglitch delay applied to fault detection.
Ut_fault_response_delay,
Vin_ov_fault_response_delay,
Vin_uv_fault_response_delay
2977f
For more information www.linear.com/LTC2977
39
LTC2977
PMBus Command Description
Timed Fault Response
TON_MAX_FAULT_RESPONSE
This command defines the LTC2977 response to a TON_MAX_FAULT. It may be used to protect against a short-circuited
output at start-up. After start-up use VOUT_UV_FAULT_RESPONSE to protect against a short-circuited output.
The device also:
• Sets the HIGH_BYTE bit in the STATUS_BYTE,
• Sets the VOUT bit in the STATUS_WORD,
• Sets the TON_MAX_FAULT bit in the STATUS_VOUT register, and
• Notifies the host by asserting ALERTB.
TON_MAX_FAULT_RESPONSE Data Contents
BIT(S) SYMBOL
OPERATION
b[7:6] Ton_max_fault_response_action Response action:
00b: The unit continues operation without interruption.
01b-11b: The unit shuts down immediately or sequences off after TOFF_DELAY (See Mfr_config_chan_
mode). After shutting down, the unit responds according to the retry settings in bits [5:3].
b[5:3] Ton_max_fault_response_retry
Response retry behavior:
000b: A zero value for the Retry Setting means that the unit does not attempt to restart. The output remains
disabled until the fault is cleared.
001b-111b: The PMBus device attempts to restart the number of times specified by the global Mfr_retry_
count[2:0] until it is commanded OFF (by the CONTROLn pin or OPERATION command or both), bias power
is removed, or another fault condition causes the unit to shut down.
b[2:0] Ton_max_fault_response_delay
Hard coded to 000b. There is no additional deglitch delay applied to fault detection.
Clearing Latched Faults
When a channel shuts down due to a fault, the off state is latched. This is referred to as a latched fault condition. Latched
faults are reset by toggling the CONTROL pin, using the OPERATION or ON_OFF_CONFIG command, or removing and
reapplying the bias voltage to the VIN_SNS pin. All fault and warning conditions result in the ALERTB pin being asserted
low and the corresponding bits being set in the status registers. The CLEAR_FAULTS command resets the contents
of the status registers and de-asserts the ALERTB output, but it does not clear a faulted off state nor allow a channel
to turn back on.
2977f
40
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
Status Commands
STATUS_BYTE:
The STATUS_BYTE command returns the summary of the most critical faults or warnings which have occurred, as
shown in the following table. STATUS_BYTE is a subset of STATUS_WORD and duplicates the same information.
STATUS_BYTE Data Contents
BIT(S)
SYMBOL
OPERATION
b[7]
Status_byte_busy
Same as Status_word_busy
b[6]
Status_byte_off
Same as Status_word_off
b[5]
Status_byte_vout_ov
Same as Status_word_vout_ov
b[4]
Status_byte_iout_oc
Same as Status_word_iout_oc
b[3]
Status_byte_vin_uv
Same as Status_word_vin_uv
b[2]
Status_byte_temp
Same as Status_word_temp
b[1]
Status_byte_cml
Same as Status_word_cml
b[0]
Status_byte_high_byte
Same as Status_word_high_byte
STATUS_WORD:
The STATUS_WORD command returns two bytes of information with a summary of the unit’s fault condition. Based on
the information in these bytes, the host can get more information by reading the appropriate detailed status register.
The low byte of the STATUS_WORD is the same register as the STATUS_BYTE command.
STATUS_WORD Data Contents
BIT(S)
SYMBOL
OPERATION
b[15]
Status_word_vout
An output voltage fault or warning has occurred. See STATUS_VOUT.
b[14]
Status_word_iout
Not supported. Always returns 0.
b[13]
Status_word_input
An input voltage fault or warning has occurred. See STATUS_INPUT.
b[12]
Status_word_mfr
A manufacturer specific fault has occurred. See STATUS_MFR_SPECIFIC and MFR_STATUS_2.
b[11]
Status_word_power_not_good
The PWRGD pin, if enabled, is negated. Power is not good.
b[10]
Status_word_fans
Not supported. Always returns 0.
b[9]
Status_word_other
Not supported. Always returns 0.
b[8]
Status_word_unknown
Not supported. Always returns 0.
b[7]
Status_word_busy
Device busy when PMBus command received. See OPERATION: Processing Commands.
b[6]
Status_word_off
This bit is asserted if the unit is not providing power to the output, regardless of the reason, including
simply not being enabled. The off bit is clear if unit is allowed to provide power to the output.
b[5]
Status_word_vout_ov
An output overvoltage fault has occurred.
b[4]
Status_word_iout_oc
Not supported. Always returns 0.
b[3]
Status_word_vin_uv
A VIN undervoltage fault has occurred.
b[2]
Status_word_temp
A temperature fault or warning has occurred. See STATUS_TEMPERATURE.
b[1]
Status_word_cml
A communication, memory or logic fault has occurred. See STATUS_CML.
b[0]
Status_word_high_byte
A fault/warning not listed in b[7:1] has occurred.
2977f
For more information www.linear.com/LTC2977
41
LTC2977
PMBus Command Description
STATUS_VOUT
The STATUS_VOUT command returns the summary of the output voltage faults or warnings which have occurred, as
shown in the following table:
STATUS_VOUT Data Contents
BIT(S) SYMBOL
OPERATION
b[7]
Status_vout_ov_fault
Overvoltage fault.
b[6]
Status_vout_ov_warn
Overvoltage warning.
b[5]
Status_vout_uv_warn
Undervoltage warning
b[4]
Status_vout_uv_fault
Undervoltage fault.
b[3]
Status_vout_max_fault
VOUT_MAX fault. An attempt has been made to set the output voltage to a value higher than allowed by the
VOUT_MAX command.
b[2]
Status_vout_ton_max_fault
TON_MAX_FAULT sequencing fault.
b[1]
Status_vout_toff_max_warn
Not supported. Always returns 0.
b[0]
Status_vout_tracking_error
Not supported. Always returns 0.
STATUS_INPUT
The STATUS_INPUT command returns the summary of the VIN faults or warnings which have occurred, as shown in
the following table:
STATUS_INPUT Data Contents
BIT(S)
SYMBOL
OPERATION
b[7]
Status_input_ov_fault
VIN Overvoltage fault
b[6]
Status_input_ov_warn
VIN Overvoltage warning
b[5]
Status_input_uv_warn
VIN Undervoltage warning
b[4]
Status_input_uv_fault
VIN Undervoltage fault
b[3]
Status_input_off
Unit is off for insufficient input voltage.
b[2]
IIN overcurrent fault
Not supported. Always returns 0.
b[1]
IIN overcurrent warn
Not supported. Always returns 0.
b[0]
PIN overpower warn
Not supported. Always returns 0.
STATUS_TEMPERATURE
The STATUS_TEMPERATURE command returns the summary of the temperature faults or warnings which have occurred, as shown in the following table:
STATUS_TEMPERATURE Data Contents
Bit(s)
Symbol
Operation
b[7]
Status_temperature_ot_fault
Overtemperature fault.
b[6]
Status_temperature_ot_warn
Overtemperature warning.
b[5]
Status_temperature_ut_warn
Undertemperature warning.
b[4]
Status_temperature_ut_fault
Undertemperature fault.
Reserved
Reserved. Always returns 0s.
b[3:0]
2977f
42
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
STATUS_CML
The STATUS_CML command returns the summary of the communication, memory and logic faults or warnings which
have occurred, as shown in the following table:
STATUS_CML Data Contents
BIT(S) SYMBOL
OPERATION
b[7]
Status_cml_cmd_fault
Illegal or unsupported command fault has occurred.
b[6]
Status_cml_data_fault
Illegal or unsupported data received.
b[5]
Status_cml_pec_fault
A PEC fault has occurred. Note: PEC checking is always active in the LTC2977. Any extra byte received before a
STOP will set Status_cml_pec_fault unless the extra byte is a matching PEC byte.
b[4]
Status_cml_memory_fault
A fault has occurred in the EEPROM.
b[3]
Status_cml_processor_fault Not supported, always returns 0.
b[2]
Reserved
Reserved, always returns 0.
b[1]
Status_cml_pmbus_fault
A communication fault other than ones listed in this table has occurred. This is a catch all category for illegally
formed I2C/SMBus commands (Example: An address byte with read =1 received immediately after a START).
b[0]
Status_cml_unknown_fault
Not supported, always returns 0.
STATUS_MFR_SPECIFIC
The STATUS_MFR_SPECIFIC command returns manufacturer specific status flags. Bits marked CHANNEL=All are
not paged. Bits marked STICKY=Yes stay set until a CLEAR_FAULTS is issued or the channel is commanded on by
the user. Bits marked ALERT=Yes pull ALERTB low when the bit is set. Bits marked OFF=Yes indicate that the event
can be configured elsewhere to turn the channel off. See MFR_STATUS_2 on page 62 for additional bits related to
manufacturer specific status.
STATUS_MFR_SPECIFIC Data Contents
BIT(S) SYMBOL
OPERATION
CHANNEL
STICKY ALERT OFF
b[7]
Status_mfr_discharge
A VOUT discharge fault occurred while attempting to enter the ON
state
Current Page
Yes
Yes
Yes
b[6]
Status_mfr_fault1_in
This channel attempted to turn on while the FAULTBz1 pin
was asserted low, or this channel has shut down at least once
in response to a FAULTBz1 pin asserting low since the last
CONTROLn pin toggle, OPERATION command ON/OFF cycle or
CLEAR_FAULTS command.
Current Page
Yes
Yes
Yes
b[5]
Status_mfr_fault0_in
This channel attempted to turn on while the FAULTBz0 pin
was asserted low, or this channel has shut down at least once
in response to a FAULTBz0 pin asserting low since the last
CONTROLn pin toggle, OPERATION command ON/OFF cycle or
CLEAR_FAULTS command.
Current Page
Yes
Yes
Yes
b[4]
Status_mfr_servo_target_reached
Servo target has been reached.
Current Page
No
No
No
b[3]
Status_mfr_dac_connected
DAC is connected and driving VDACP pin.
Current Page
No
No
No
b[2]
Status_mfr_dac_saturated
A previous servo operation terminated with maximum or
minimum DAC value.
Current Page
Yes
No
No
b[1]
Status_mfr_vinen_faulted_off
VIN_EN has been deasserted due to a VOUT fault.
All
No
No
No
b[0]
Status_mfr_watchdog_fault
A watchdog fault has occurred.
All
Yes
Yes
No
2977f
For more information www.linear.com/LTC2977
43
LTC2977
PMBus Command Description
ADC Monitoring Commands
READ_VIN
This command returns the most recent ADC measured value of the voltage measured at the VIN_SNS pin.
READ_VIN Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Read_vin[15:0] The data uses the L11 format.
Units: V
READ_VOUT
This command returns the most recent ADC measured value of the channel’s output voltage. When odd channels are
configured to measure current, the data contents use the L11 format with units in mV.
READ_VOUT Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Read_vout[15:0] The data uses the L16 format.
Units: V
READ_VOUT Data Contents—for Odd Channels Configured to Measure Current (Mfr_config_adc_hires = 1)
Bit(s)
Symbol
Operation
b[15:0] Read_vout[15:0] The data uses the L11 format.
Units: mV
READ_TEMPERATURE_1
This command returns the most recent ADC measured value of junction temperature in °C as determined by the
LTC2977’s internal temperature sensor.
READ_TEMPERATURE_1 Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Read_temperature_1 [15:0] The data uses the L11 format.
Units: °C.
PMBUS_REVISION
The PMBUS_REVISION command register is read only and reports the LTC2977 compliance to the PMBus standard
revision 1.1.
PMBUS_REVISION Data Contents
BIT(S) SYMBOL
OPERATION
b[7:0] PMBus_rev
Reports the PMBus standard revision compliance. This is hard-coded to 0x11 for revision 1.1.
2977f
44
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
Manufacturer Specific Commands
MFR_CONFIG_LTC2977
This command is used to configure various manufacturer specific operating parameters for each channel.
MFR_CONFIG_LTC2977 Data Contents
BIT(S) SYMBOL
b[15:14] Mfr_config_chan_mode
OPERATION
Select channel specific sequencing mode.
00 = Channel uses PMBus delay sequencing with immediate off upon fault.
01 = Channel uses PMBus delay sequencing with sequence off upon fault.
1x = Channel is a slave in a tracked power supply system.
b[13:12] Reserved
Don’t care. Always returns 0.
b[11] Mfr_config_fast_servo_off
Disables fast servo when margining or trimming output voltages:
0: fast-servo enabled.
1: fast-servo disabled.
b[10] Mfr_config_supervisor_resolution Selects supervisor resolution:
0: high resolution = 4mV/LSB, range for VVSENSEPn – VVSENSEMn is 0V to 3.8V.
1: low resolution = 8mV/LSB, range for VVSENSEPn – VVSENSEMn is 0V to 6.0V.
b[9] Mfr_config_adc_hires
Selects ADC resolution for odd channels. This is typically used to measure current. Ignored for even
channels (they always use low resolution).
0: low resolution = 122µV/LSB.
1: high resolution = 15.6µV/LSB.
b[8] Mfr_config_controln_sel
Selects the active control pin input (CONTROL0 or CONTROL1) for this channel.
0: Select CONTROL0 pin.
1: Select CONTROL1 pin.
b[7] Mfr_config_servo_continuous
Select whether the UNIT should continuously servo VOUT after it has reached a new margin or nominal
target. Only applies when Mfr_config_dac_mode = 00b.
0: Do not continuously servo VOUT after reaching initial target.
1: Continuously servo VOUT to target.
b[6] Mfr_config_servo_on_warn
Control re-servo on warning feature. Only applies when Mfr_config_dac_mode = 00b and
Mfr_config_servo_continuous = 0.
0: Do not allow the unit to re-servo when a VOUT warning threshold is met or exceeded.
b[5:4]
Mfr_config_dac_mode
b[3]
Mfr_config_vo_en_wpu_en
b[2]
Mfr_config_vo_en_wpd_en
1: Allow the unit to re-servo VOUT to nominal target if
VOUT ≥ V(Vout_ov_warn_limit) or
VOUT ≤ V(Vout_uv_warn_limit).
Determines how DAC is used when channel is in the ON state and TON_RISE has elapsed.
00: Soft-connect (if needed) and servo to target.
01: DAC not connected.
10: DAC connected immediately using value from MFR_DAC command. If this is the configuration after a
reset or RESTORE_USER_ALL, MFR_DAC will be undefined and must be written to desired value.
11: DAC is soft-connected. After soft-connect is complete MFR_DAC may be written.
VOUT_EN pin charge-pumped, current-limited pull-up enable.
0: Disable weak pull-up. VOUT_EN pin driver is three-stated when channel is on.
1: Use weak current-limited pull-up on VOUT_EN pin when the channel is on.
For channels 4-7 this bit is treated as a 0 regardless of its value.
VOUT_EN pin current-limited pull-down enable.
0: Use a fast N-channel device to pull down VOUT_EN pin when the channel is off for any reason.
1: Use weak current-limited pull-down to discharge VOUT_EN pin when channel is off due to soft stop by the
CONTROLn pin and/or OPERATION command. If the channel is off due to a fault, use the fast pull-down on
VOUT_EN pin.
For channels 4-7 this bit is treated as a 0 regardless of its value.
2977f
For more information www.linear.com/LTC2977
45
LTC2977
PMBus Command Description
MFR_CONFIG_LTC2977 Data Contents
BIT(S)
b[1]
SYMBOL
Mfr_config_dac_gain
b[0]
Mfr_config_dac_pol
OPERATION
DAC buffer gain.
0: Select DAC buffer gain dac_gain_0 (1.38V full-scale)
1: Select DAC buffer gain dac_gain_1 (2.65V full-scale)
DAC output polarity.
0: Encodes negative (inverting) DC/DC converter trim input.
1: Encodes positive (noninverting) DC/DC converter trim input.
Tracking Supplies On and Off
The LTC2977 supports tracking power supplies that are equipped with a tracking pin and configured for tracking.
A tracking power supply uses a secondary feedback terminal (TRACK) to allow its output voltage to be scaled to an
external master voltage. Typically the external voltage is generated by the supply with the highest voltage in the system, which is fed to the slave track pins (see Figure 13a). Supplies that track a master supply must be enabled before
the master supply comes up and disabled after the master supply comes down. Enabling the slave supplies when the
master is down requires supervisors monitoring the slaves to disable UV detection. All channels configured for tracking must track off together in response to a fault on any channel or any other condition that can bring one or more of
the channels down. Prematurely disabling a slave channel via its RUN pin may cause that channel to shut down out
of sequence (see Figure 13d)
LTC2977
CONTROL0
FAULTB0
CONTROL0
PWRGD
FAULT00
VSENSEP0
VOUT_EN0
VSENSEM0
VDACP0
RUN
VFB
VOUTP
DC/DC
VOUTM
TRACK
VSENSEP1
VOUT_EN1
VSENSEM1
VDACP1
RUN
VFB
R1_1
VSENSEP2
VOUT_EN2
VSENSEM2
VDACP2
VOUT_EN3
VSENSEM3
VDACP3
VFB
VSENSEP1
LOAD
VOUTM
VOUTP
DC/DC
VSENSEM1
VOUTM
TRACK
VSENSEP2
LOAD
VSENSEM2
R2_2
RUN
VFB
R1_3
VSENSEM0
R2_1
RUN
R1_2
VSENSEP3
VOUTP
DC/DC
TRACK
VSENSEP0
LOAD
VOUTP
DC/DC
TRACK
R2_3
VSENSEP3
LOAD
VOUTM
VSENSEM3
2977 F13a
Figure 13a. LTC2977 Configured to Control, Supervise and Monitor Power Supplies Equipped with Tracking Pin
2977f
46
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
An important feature of the LTC2977 is the ability to control, monitor, and supervise DC/DC converters that are configured to track a master supply on and off.
The LTC2977 supports the following tracking features:
• Track channels on and off without issuing false UV events when the slave channels are tracking up or down.
• Track all channels down in response to a fault from a slave or master.
• Track all channels down when VIN_SNS drops below VIN_OFF, share clock is held low or RESTORE_USER_ALL is
issued.
• Ability to reconfigure selected channels that are part of a tracking group to sequence up after the group has tracked
up or sequence down before the group has tracked down.
TON_RISE EXPIRES
FOR ALL CHANNELS.
UV DETECT ENABLED
ON ALL CHANNELS
VOUT0
TOFF_DELAY ENTERED
FOR ALL CHANNELS.
UV DETECT DISABLED
ON ALL CHANNELS
VOUT1
VOUT2
MASTER BRINGS DOWN
NEXT HIGHEST SLAVE
VOUT3
CONTROL
VOUT_EN0
VOUT_EN(3:1)
2977 F13b
SLAVE OUTPUT ENABLES TURN ON FIRST
SLAVE OUTPUT ENABLES TURN OFF LAST
Figure 13b. Control Pin Tracking All Supplies Up And Down
TON_RISE EXPIRES
FOR ALL CHANNELS.
UV DETECT ENABLED
ON ALL CHANNELS
TOFF_DELAY ENTERED
FOR ALL CHANNELS.
UV DETECT DISABLED
ON ALL CHANNELS
VOUT0
UV FAULT ON CHANNEL 1 BRINGS DOWN MASTER
VIA FAULTB0. ALL SLAVE CHANNELS INCLUDING
THE ONE WITH THE UV FAULT ENTER TOFF_DELAY
VOUT1
VOUT2
VOUT3
MASTER BRINGS DOWN
NEXT HIGHEST SLAVE
CONTROL
FAULTB0
VOUT_EN0
VOUT_EN(3:1)
2977 F13c
SLAVE OUTPUT ENABLES TURN ON FIRST
SLAVE OUTPUT ENABLES TURN OFF LAST
Figure 13c. Fault on Channel 1 Tracking All Supplies Down
2977f
For more information www.linear.com/LTC2977
47
LTC2977
PMBus Command Description
TON_RISE EXPIRES
FOR ALL CHANNELS.
UV DETECT ENABLED
ON ALL CHANNELS
TOFF_DELAY ENTERED
FOR ALL CHANNELS.
UV DETECT DISABLED
ON ALL CHANNELS
VOUT0
VOUT1
VOUT2
UV FAULT ON CHANNEL 1 BRINGS DOWN MASTER
VIA FAULTB0. ALL SLAVES WITH ENABLED RUN
PINS TRACK DOWN CORRECTLY
VOUT3
DISABLING VOUT_EN1
IMMEDIATELY IN RESPONSE
TO THE UV FAULT CAUSES
VOUT1 TO SHUT DOWN
OUT OF SEQUENCE
CONTROL
FAULTB0
VOUT_EN0
VOUT_EN1
VOUT_EN(3:2)
2977 F13d
SLAVE OUTPUT ENABLES TURN ON FIRST
SLAVE OUTPUT ENABLES TURN OFF LAST
Figure 13d. Improperly Configured Fault Response on Faulting Channel Disrupts Tracking
Tracking Implementation
The LTC2977 supports tracking through the coordinated programing of Ton_delay, Ton_rise,Toff_delay and Mfr_config_
chan_mode. The master channel must be configured to turn on after all the slave channels have turned on and to turn
off before all the slave channels turn off. Slaves that are enabled before the master will remain off until the tracking pin
allows them to turn on. Slaves will be turned off via the tracking pin even though their run pin is still asserted. Ton_rise
must be extended on the slaves so that it ends relative to the rise of the TRACK pin and not the rise of the VOUT_EN pin.
When Mfr_config_chan_mode = 1Xb the channel is reconfigured to:
• Sequence down on fault, VIN_OFF, SHARE_CLK low or RESTORE_USER_ALL.
• Ignore UV during TOFF_DELAY. Note that ignoring UV during TON_RISE and TON_MAX_FAULT always happens
regardless of how these configuration bits are set.
The following example illustrates configuring an LTC2977 with one master channel and three slaves.
Master channel 0
TON_DELAY = Ton_delay_master
TON_RISE = Ton_rise_master
TOFF_DELAY = Toff_delay_master
Mfr_config_chan_mode = 00
Slave channel n
TON_DELAY = Ton_delay_slave
TON_RISE = Ton_delay_master + Ton_rise_slave
2977f
48
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
TOFF_DELAY = Toff_delay_master + Toff_delay_slave
Mfr_config_chan_mode = 10b
Where:
Ton_delay_master – Ton_delay_slave > RUN to TRACK setup time
Toff_delay_slave > time for master supply to fall.
The system response to a control pin toggle is illustrated in Figure 13b.
The system response to a UV fault on a slave channel is illustrated in Figure 13c.
MFR_CONFIG_ALL_LTC2977
This command is used to configure parameters that are common to all channels on the IC. They may be set or reviewed
from any PAGE setting.
MFR_CONFIG_ALL_LTC2977 Data Contents
BIT(S) SYMBOL
b[15-13] Reserved
b[12]
OPERATION
Don’t care. Always returns 0
Mfr_config_all_en_short_cycle_fault Enable short cycle fault detection. See Mfr_status_2_short_cycle_fault on page 62 for more information.
0: Issuing an ON before prior OFF is complete will not cause a fault.
b[11]
Mfr_config_all_pwrgd_off_uses_uv
1: Issuing an ON before prior OFF is complete will cause a fault.
Selects PWRGD de-assertion source for all channels.
0: PWRGD is de-asserted based on VOUT being below or equal to POWER_GOOD_OFF. This option uses
the ADC. Response time is approximately 100ms to 200ms.
b[10]
Mfr_config_all_fast_fault_log
1: PWRGD is de-asserted based on VOUT being below or equal to VOUT_UV_LIMIT. This option uses the
high speed supervisor. Response time is approximately 12µs
Controls number of ADC readings completed before transferring fault log memory to EEPROM.
0: Slower. All ADC telemetry values will be updated before transferring fault log to EEPROM.
b[9:8]
b[7]
b[6]
b[5]
b[4]
b[3]
Reserved
1: Faster. Telemetry values will be transferred from fault log to EEPROM within 24ms after detecting fault.
Don’t care. Always returns 0
Enable fault logging to EEPROM in response to Fault.
0: Fault logging to EEPROM is disabled
1: Fault logging to EEPROM is enabled
Mfr_config_all_vin_on_clr_faults_en Allow VIN rising above VIN_ON to clear all latched faults
0: VIN_ON clear faults feature is disabled
1: VIN_ON clear faults feature is enabled
Mfr_config_all_control1_pol
Selects active polarity of CONTROL1 pin.
0: Active low (pull pin low to start unit)
1: Active high (pull pin high to start unit)
Mfr_config_all_control0_pol
Selects active polarity of CONTROL0 pin.
0: Active low (pull pin low to start unit)
1: Active high (pull pin high to start unit)
Mfr_config_all_vin_share_enable
Allow this unit to hold SHARE_CLK pin low when VIN has not risen above VIN_ON or has fallen below
VIN_OFF. When enabled, this unit will also turn all channels off in response to SHARE_CLK being held low.
0: SHARE_CLK inhibit is disabled
1: SHARE_CLK inhibit is enabled
Mfr_config_all_fault_log_enable
2977f
For more information www.linear.com/LTC2977
49
LTC2977
PMBus Command Description
MFR_CONFIG_ALL_LTC2977 Data Contents
BIT(S) SYMBOL
b[2]
Mfr_config_all_pec_en
b[1]
Mfr_config_all_longer_pmbus_
timeout
b[0]
Mfr_config_all_vinen_wpu_dis
OPERATION
PMBus packet error checking enable.
0: PEC is accepted but not required
1: PEC is required
Increase PMBus timeout internal by a factor of 8. Recommended for fault logging.
0: PMBus timeout is not multiplied by a factor of 8
1: PMBus timeout is multiplied by a factor of 8
VIN_EN charge-pumped, current-limited pull-up disable.
0: Use weak current-limited pull-up on VIN_EN after power-up, as long as no faults have forced VIN_EN off.
1: Disable weak pull-up. VIN_EN driver is three-stated after power-up as long as no faults have forced
VIN_EN off.
MFR_FAULTBz0_PROPAGATE, MFR_FAULTBz1_PROPAGATE
These manufacturer specific commands enable channels that have faulted off to propagate that state to the appropriate fault pin. Faulted off states for pages 0 through 3 can only be propagated to pins FAULTB00 and FAULTB01; this is
referred to as zone 0. Faulted off states for pages 4 through 7 can only be propagated to pins FAULTB10 and FAULTB11;
this is referred to as zone 1. The z designator in the command name is used to indicate that this command affects
different zones depending on the page. See Figure 20.
Note that pulling a fault pin low will have no effect for channels that have MFR_FAULTBzn_RESPONSE set to 0. The
channel continues operation without interruption. This fault response is called Ignore (0x0) in LTpowerPlay.
MFR_FAULTz0_PROPAGATE Data Content
BIT(S)
SYMBOL
OPERATION
b[7:1]
Reserved
Don’t care. Always returns 0.
b[0]
Mfr_faultbz0_propagate
Enable fault propagation.
For pages 0 through 3, zone 0
0: Channel’s faulted off state does not assert FAULTB00 low.
1: Channel’s faulted off state asserts FAULTB00 low.
For pages 4 through 7, zone 1
0: Channel’s faulted off state does not assert FAULTB10 low.
1: Channel’s faulted off state asserts FAULTB10 low.
MFR_FAULTz1_PROPAGATE Data Content
BIT(S)
SYMBOL
OPERATION
b[7:1]
Reserved
Don’t care. Always returns 0.
Mfr_faultbz1_propagate
Enable fault propagation.
For pages 0 through 3, zone 0
0: Channel’s faulted off state does not assert FAULTB01 low.
1: Channel’s faulted off state asserts FAULTB01 low.
For pages 4 through 7, zone 1
0: Channel’s faulted off state does not assert FAULTB11 low.
1: Channel’s faulted off state asserts FAULTB11 low.
b[0]
2977f
50
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_PWRGD_EN
This command register controls the mapping of the watchdog and channel power good status to the PWRGD pin. Note
that odd numbered channels whose ADC is in high res mode do not contribute to power good.
MFR_PWRGD_EN Data Contents
BIT(S) SYMBOL
OPERATION
b[15:9] Reserved
Read only, always returns 0s.
b[8]
Mfr_pwrgd_en_wdog
Watchdog
1 = Watchdog timer not-expired status is ANDed with PWRGD status for any similarly enabled channels to
determine when the PWRGD pin gets asserted.
0 = Watchdog timer does not affect the PWRGD pin.
b[7]
Mfr_pwrgd_en_chan7
Channel 7
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
b[6]
Mfr_pwrgd_en_chan6
Channel 6
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
b[5]
Mfr_pwrgd_en_chan5
Channel 5
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
b[4]
Mfr_pwrgd_en_chan4
Channel 4
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
b[3]
Mfr_pwrgd_en_chan3
Channel 3
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
b[2]
Mfr_pwrgd_en_chan2
Channel 2
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
b[1]
Mfr_pwrgd_en_chan1
Channel 1
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
b[0]
Mfr_pwrgd_en_chan0
Channel 0
1 = PWRGD status for this channel is ANDed with PWRGD status for any similarly enabled channels to determine
when the PWRGD pin gets asserted.
0 = PWRGD status for this channel does not affect the PWRGD pin.
2977f
For more information www.linear.com/LTC2977
51
LTC2977
PMBus Command Description
MFR_FAULTB00_RESPONSE, MFR_FAULTB01_RESPONSE, MFR_FAULTB10_RESPONSE and MFR_
FAULTB11_RESPONSE
These manufacturer specific commands share the same format and specify the response to assertions of the FAULTB
pins. For fault zone 0, MFR_FAULTB00_RESPONSE determines whether channels 0 to 3 shut off when the FAULTB00
pin is asserted, and MFR_FAULTB01_RESPONSE determines whether channels 0 to 3 shut off when the FAULTB01
pin is asserted. For fault zone 1, MFR_FAULTB10_RESPONSE determines whether channels 4 to 7 shut off when the
FAULTB10 pin is asserted, and MFR_FAULTB11_RESPONSE determines whether channels 4 to 7 shut off when the
FAULTB11 pin is asserted. When a channel shuts off in response to a FAULTB pin, the ALERTB pin is asserted low and
the appropriate bit is set in the STATUS_MFR_SPECIFIC register. For a graphical explanation, see the switches on the
left hand side of Figure 20, Channel Fault Management Block Diagram.
Data Contents—Fault Zone 0 Response Commands
BIT(S) SYMBOL
b[7:4] Reserved
b[3] Mfr_faultb00_response_chan3,
Mfr_faultb01_response_chan3
b[2]
Mfr_faultb00_response_chan2,
Mfr_faultb01_response_chan2
b[1]
Mfr_faultb00_response_chan1,
Mfr_faultb01_response_chan1
b[0]
Mfr_faultb00_response_chan0,
Mfr_faultb01_response_chan0
OPERATION
Read only, always returns 0s.
Channel 3 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
Channel 2 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
Channel 1 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
Channel 0 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
Data Contents—Fault Zone 1 Response Commands
BIT(S) SYMBOL
b[7:4] Reserved
b[3] Mfr_faultb10_response_chan7,
Mfr_faultb11_response_chan7
b[2]
Mfr_faultb10_response_chan6,
Mfr_faultb11_response_chan6
b[1]
Mfr_faultb10_response_chan5,
Mfr_faultb11_response_chan5
b[0]
Mfr_faultb10_response_chan4,
Mfr_faultb11_response_chan4
OPERATION
Read only, always returns 0s.
Channel 7 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
Channel 6 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
Channel 5 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
Channel 4 response.
0: The channel continues operation without interruption.
1: The channel shuts down if the corresponding FAULTBzn pin is still asserted after 10µs. When the FAULTBzn
pin subsequently deasserts, the channel turns back on, honoring TON_DELAY and TON_RISE settings.
2977f
52
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_VINEN_OV_FAULT_RESPONSE
This command register determines whether VOUT overvoltage faults from a given channel cause the VIN_EN pin to be
pulled low.
MFR_VINEN_OV_FAULT_RESPONSE Data Contents
BIT(S) SYMBOL
b[7]
Mfr_vinen_ov_fault_response_chan7
OPERATION
Response to channel 7 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[6]
Mfr_vinen_ov_fault_response_chan6
Response to channel 6 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[5]
Mfr_vinen_ov_fault_response_chan5
Response to channel 5 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[4]
Mfr_vinen_ov_fault_response_chan4
Response to channel 4 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[3]
Mfr_vinen_ov_fault_response_chan3
Response to channel 3 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[2]
Mfr_vinen_ov_fault_response_chan2
Response to channel 2 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[1]
Mfr_vinen_ov_fault_response_chan1
Response to channel 1 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[0]
Mfr_vinen_ov_fault_response_chan0
Response to channel 0 VOUT_OV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
2977f
For more information www.linear.com/LTC2977
53
LTC2977
PMBus Command Description
MFR_VINEN_UV_FAULT_RESPONSE
This command register determines whether VOUT undervoltage faults from a given channel cause the VIN_EN pin to be
pulled low.
MFR_VINEN_UV_FAULT_RESPONSE Data Contents
BIT(S) SYMBOL
b[7]
Mfr_vinen_uv_fault_response_chan7
OPERATION
Response to channel 7 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[6]
Mfr_vinen_uv_fault_response_chan6
Response to channel 6 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[5]
Mfr_vinen_uv_fault_response_chan5
Response to channel 5 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[4]
Mfr_vinen_uv_fault_response_chan4
Response to channel 4 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[3]
Mfr_vinen_uv_fault_response_chan3
Response to channel 3 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[2]
Mfr_vinen_uv_fault_response_chan2
Response to channel 2 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[1]
Mfr_vinen_uv_fault_response_chan1
Response to channel 1 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
b[0]
Mfr_vinen_uv_fault_response_chan0
Response to channel 0 VOUT_UV_FAULT.
1 = Disable (pull low) VIN_EN via fast pull-down.
0 = Do not disable VIN_EN.
2977f
54
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_RETRY_COUNT
The MFR_RETRY_COUNT is a global command that sets the number of retries attempted when any channel faults off
with its fault response retry field set to a non zero value.
In the event of multiple or recurring retry faults on the same channel the total number of retries equals MFR_RETRY_
COUNT. If a channel has not been faulted off for 6 seconds, its retry counter is cleared. Toggling a channel’s CONTROL
pin off then on or issuing OPERATION off then on commands will synchronously clear the retry count. Writing to
MFR_RETRY_COUNT clears the retry count for all channels
MFR_RETRY_COUNT Data Contents
BIT(S) SYMBOL
OPERATION
b[7:3] Reserved
Always returns zero.
b[2:0] Mfr_retry_count [2:0]
0: No retries:
1-6: Number of retries.
7: Infinite retries.
MFR_RETRY_DELAY
This command determines the retry interval when the LTC2977 is in retry mode in response to a fault condition. The read
value of this command always returns what was last written and does not reflect internal limiting.
MFR_RETRY_DELAY Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Mfr_retry_delay The data uses the L11 format.
This delay is counted using SHARE_CLK only.
Delays are rounded to the nearest 200µs.
Units: ms. Max delay is 13.1 sec.
MFR_RESTART_DELAY
This command sets the minimum off time of a CONTROL initiated restart. If the CONTROL pin is toggled off for at least 10µs
then on, all dependent channels are disabled, held off for a time = Mfr_restart_delay, then sequenced back on. CONTROLn
pin transitions whose OFF time exceeds Mfr_restart_delay are not affected by this command. A value of all zeros disables
this feature. The read value of this command always returns what was last written and does not reflect internal limiting.
MFR_RESTART_DELAY Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Mfr_restart_delay The data uses the L11 format.
This delay is counted using SHARE_CLK only.
Delays are rounded to the nearest 200µs.
Units: ms. Max delay is 13.1 sec.
2977f
For more information www.linear.com/LTC2977
55
LTC2977
PMBus Command Description
MFR_VOUT_PEAK
This command returns the maximum ADC measured value of the channel’s output voltage. This command is not
supported for odd channels that are configured to measure current. This register is reset to 0xF800 (0.0) when the
LTC2977 emerges from power-on reset or when a CLEAR_FAULTS command is executed.
MFR_VOUT_PEAK Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Mfr_vout_peak[15:0] The data uses the L16 format.
Units: V.
MFR_VIN_PEAK
This command returns the maximum ADC measured value of the input voltage. This register is reset to 0x7C00 (–225)
when the LTC2977 emerges from power-on reset or when a CLEAR_FAULTS command is executed.
MFR_VIN_PEAK Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Mfr_vin_peak[15:0] The data uses the L11 format.
Units: V
MFR_TEMPERATURE_PEAK
This command returns the maximum ADC measured value of junction temperature in °C as determined by the LTC2977’s
internal temperature sensor. This register is reset to 0x7C00 (–225) when the LTC2977 emerges from power-on reset
or when a CLEAR_FAULTS command is executed.
MFR_TEMPERATURE_PEAK Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Mfr_temperature_peak[15:0] The data uses the L11 format.
Units: °C.
2977f
56
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_DAC
This command register allows the user to directly program the 10-bit DAC. Manual DAC writes require the channel
to be in the ON state,TON_RISE to have expired and MFR_CONFIG_LTC2977 b[5:4] = 10b or 11b. Writing MFR_
CONFIG_LTC2977 b[5:4] = 10b commands the DAC to hard-connect with the value in Mfr_dac_direct_val. Writing
b[5:4] = 11b commands the DAC to soft-connect. Once the DAC has soft-connected, Mfr_dac_direct_val returns the
value that allowed the DAC to be connected without perturbing the power supply. MFR_DAC writes are ignored when
MFR_CONFIG_LTC2977 b[5:4] = 00b or 01b.
MFR_DAC Data Contents
BIT(S)
SYMBOL
b[15:10] Reserved
b[9:0]
OPERATION
Read only, always returns 0.
Mfr_dac_direct_val DAC code value.
MFR_POWERGOOD_ASSERTION_DELAY
This command register allows the user to program the delay from when the internal power good signal becomes valid
until the power good output is asserted. This delay is counted using SHARE_CLK if available, otherwise the internal
oscillator is used. This delay is internally limited to 13.1 seconds, and rounded to the nearest 200µs. The read value
of this command always returns what was last written and does not reflect internal limiting.
The power good de-assertion delay and threshold source is controlled by Mfr_config_all_pwrgd_off_uses_uv.
Systems that require a fast power good de-assertion should set Mfr_config_all_pwrgd_off_uses_uv=1. This uses the
VOUT_UV_FAULT_LIMIT and the high speed comparator to de-assert the PWRGD pin. Systems that require a separate
power good off threshold should set Mfr_config_all_pwrgd_off_uses_uv=0. This uses the slower ADC polling loop
and POWER_GOOD_OFF to de-assert the PWRGD pin.
MFR_POWERGOOD_ASSERTION_DELAY Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Mfr_powergood_assertion_delay
The data uses the L11 format.
This delay is counted using SHARE_CLK if available, otherwise the internal oscillator is used.
Delays are rounded to the nearest 200µs.
Units: ms. Max delay is 13.1 sec.
2977f
For more information www.linear.com/LTC2977
57
LTC2977
PMBus Command Description
MFR_PADS
The MFR_PADS command provides read only access to slow frequency digital pads (pins). The input values presented
in bits[9:0] are before any deglitching logic.
MFR_PADS Data Contents
BIT(S) SYMBOL
b[15] Mfr_pads_pwrgd_drive
OPERATION
0 = PWRGD pad is being driven low by this chip
b[14]
1 = PWRGD pad is not being driven low by this chip
0 = ALERTB pad is being driven low by this chip
Mfr_pads_alertb_drive
1 = ALERTB pad is not being driven low by this chip
b[13:10] Mfr_pads_faultb_drive[3:0] Bit[3] used for FAULTB00 pad, bit[2] used for FAULTB01 pad, bit[1] used for FAULTB10 pad, bit[0] used for
FAULTB11 pad as follows:
0 = FAULTBzn pad is being driven low by this chip
b[9:8]
Mfr_pads_asel1[1:0]
1 = FAULTBzn pad is not being driven low by this chip
11: Logic high detected on ASEL1 input pad
10: ASEL1 input pad is floating
01: Reserved
b[7:6]
Mfr_pads_asel0[1:0]
00: Logic low detected on ASEL1 input pad
11: Logic high detected on ASEL0 input pad
10: ASEL0 input pad is floating
01: Reserved
b[5]
Mfr_pads_control1
00: Logic low detected on ASEL0 input pad
1: Logic high detected on CONTROL1 pad
b[4]
Mfr_pads_control0
0: Logic low detected on CONTROL1 pad
1: Logic high detected on CONTROL0 pad
b[3:0]
Mfr_pads_faultb[3:0]
0: Logic low detected on CONTROL0 pad
Bit[3] used for FAULTB00 pad, bit[2] used for FAULTB01 pad, bit[1] used for FAULTB10 pad, bit[0] used for
FAULTB11 pad as follows:
1: Logic high detected on FAULTBzn pad
0: Logic low detected on FAULTBzn pad
2977f
58
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_SPECIAL_ID
This register contains the manufacturer ID for the LTC2977.
MFR_SPECIAL_ID Data Contents
BIT(S)
SYMBOL
OPERATION
b[15:0]
Mfr_special_id
Read only, always returns 0x0130
MFR_SPECIAL_LOT
These paged registers contain information that identifies the user configuration that was programmed at the factory.
Contact the factory to request a custom factory programmed user configuration and special lot number.
MFR_SPECIAL_LOT Data Contents
BIT(S)
SYMBOL
OPERATION
b[7:0]
Mfr_special_lot
Contains the LTC default special lot number. Contact the factory to request a custom factory programmed user configuration and special lot number.
MFR_VOUT_DISCHARGE_THRESHOLD
This register contains the coefficient that multiplies VOUT_COMMAND in order to determine the OFF threshold
voltage for the associated output. If the output voltage has not decayed below MFR_VOUT_DISCHARGE_
THRESHOLD • VOUT_COMMAND prior to the channel being commanded to enter/re-enter the ON state, the Status_
mfr_discharge bit in the STATUS_MFR_SPECIFIC register will be set and the ALERTB pin will be asserted low. In
addition, the channel will not enter the ON state until the output has decayed below its OFF threshold voltage. Setting
this to a value greater than 1.0 effectively disables DISCHARGE_THRESHOLD checking, allowing the channel to turn
back on even if it has not decayed at all.
Other channels can be held off if a particular output has failed to discharge by using the bidirectional FAULTBzn pins
(refer to the MFR_FAULTBzn_RESPONSE and MFR_FAULTBzn_PROPAGATE registers).
MFR_VOUT_DISCHARGE_THRESHOLD Data Contents
BIT(S)
SYMBOL
OPERATION
b[15:0]
Mfr_vout_discharge_
threshold
The data uses the L11 format.
Units: Dimensionless, this register contains a coefficient.
2977f
For more information www.linear.com/LTC2977
59
LTC2977
PMBus Command Description
MFR_COMMON
This command returns status information for the alert pin (ALERTB), share-clock pin (SHARE_CLK), write-protect pin
(WP), and device busy state.
This is the only command that may still be read when the device is busy processing an EEPROM or other command. It
may be polled by the host to determine when the device is available to process a PMBus command. A busy device will
always acknowledge its address but will NACK the command byte and set Status_byte_busy and Status_word_busy
when it receives a command that it cannot immediately process.
MFR_COMMON Data Contents
BIT(S)
b[7]
SYMBOL
OPERATION
Mfr_common_alertb
Returns alert status.
1: ALERTB is de-asserted high.
0: ALERTB is asserted low.
b[6]
Mfr_common_busyb
Returns device busy status.
1: The device is available to process PMBus commands.
0: The device is busy and will NACK PMBus commands.
b[5:2]
Reserved
Read only, always returns 1s
b[1]
Mfr_common_share_clk
Returns status of share-clock pin
1: Share-clock pin is being held low
0: Share-clock pin is active
b[0]
Mfr_common_write_protect Returns status of write-protect pin
1: Write-protect pin is high
0: Write-protect pin is low
USER_DATA_00, USER_DATA_01, USER_DATA_02, USER_DATA_03, USER_DATA_04, MFR_LTC_RESERVED_1
and MFR_LTC_RESERVED_2
These registers are provided as user scratchpad and additional manufacturer reserved locations.
USER_DATA_00, USER_DATA_01, MFR_LTC_RESERVED_1 and MFR_LTC_RESERVED_2 are all reserved for
manufacturer use. Such uses include manufacturer traceability information and LTpowerPlay features like the
CRC calculation and storage for user EEPROM configurations.
USER_DATA_02 is reserved for OEM use. These 2 bytes might be used for OEM traceability or revision information.
USER_DATA_03 and USER_DATA_04 are available for user scratchpad use. These 18 bytes (1 unpaged word plus
8 paged words) might be used for traceability or revision information such as serial number, board model number,
assembly location, or assembly date.
All user and OEM scratchpad registers may be stored and recalled from EEPROM using the STORE_USER_ALL and
RESTORE_USER_ALL commands.
2977f
60
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_VOUT_MIN
This command returns the minimum ADC measured value of the channel’s output voltage. This register is
reset to 0xFFFF (7.999) when the LTC2977 emerges from power-on reset or when a CLEAR_FAULTS command is executed. When odd channels are configured to measure current, this command is not supported.
Updates are disabled when undervoltage detection is disabled, such as when Margin Low (Ignore Faults and
Warnings) is enabled.
MFR_VOUT_MIN Data Contents
BIT(S)
SYMBOL
OPERATION
b[15:0]
Mfr_vout_min
The data uses the L16 format.
Units: V.
MFR_VIN_MIN
This command returns the minimum ADC measured value of the input voltage. This register is reset to 0x7BFF
(approximately 225) when the LTC2977 emerges from power-on reset or when a CLEAR_FAULTS command is executed.
Updates are disabled when unit is off for insufficient input voltage.
MFR_VIN_MIN Data Contents
BIT(S)
SYMBOL
OPERATION
b[15:0]
Mfr_vin_min
The data uses the L11 format.
Units: V.
MFR_TEMPERATURE_MIN
This command returns the minimum ADC measured value of junction temperature in °C as determined by the LTC2977’s
internal temperature sensor. This register is reset to 0x7BFF (approximately 225) when the LTC2977 emerges from
power-on reset or when a CLEAR_FAULTS command is executed.
MFR_TEMPERATURE_MIN Data Contents
BIT(S)
SYMBOL
b[15:0]
Mfr_temperature_min The data uses the L11 format.
OPERATION
Units: °C.
2977f
For more information www.linear.com/LTC2977
61
LTC2977
PMBus Command Description
MFR_STATUS_2
This command returns additional manufacturer specific fault and state information. Bits marked Sticky = Yes are set
by the appropriate event and not cleared until the user issues a CLEAR_FAULTS command or turns the channel back
on. Bits marked ALERT = Yes assert ALERTB low when they are set. Bits marked Channel = All are not paged.
MFR_STATUS_2 Data Contents
BIT(S)
SYMBOL
b[15:3] Reserved
b[2]
OPERATION
STICKY ALERT CHANNEL
Read only, always returns 0s.
Mfr_status_2_short_cycle_fault 1: This channel was commanded on by user before it finished sequencing off.
Yes
Yes
Current
Page
No
No
All
Yes
No
Current
Page
0: No short cycle fault has occurred for this channel.
b[1]
Mfr_status_2_vinen_drive
1: VIN_EN pad is being driven low by this chip.
0: VIN_EN pad is not being driven low by this chip.
b[0]
Mfr_status_2_vin_caused_off
1: This channel was turned off due to VIN_SNS dropping below the VIN_OFF
threshold.
0: VIN_SNS has not caused this channel to turn off.
Short cycle fault detection is used to prevent out-of-order on sequencing when the user issues an ON command too
soon after an OFF command. If some channels are still finishing OFF delays when the early ON command is received,
they might turn back on too late. This fault should be propagated to all channels in the sequence to ensure a clean
ON sequence. When a channel detects a short cycle fault it sets Mfr_status_2_short_cycle_fault, Status_word_mfr,
Status_word_high_byte, and pulls ALERTB low. It also faults off, and stays off until the user issues an OFF-THEN-ON
sequence or resets the part. Fault retries are not supported for short cycle faults.
Mfr_status_2_vinen_drive indicates the current status of this chip’s VIN_EN pad driver. It is not affected by CLEAR_
FAULTS commands, and no other status bits are affected when it is set.
Mfr_status_2_vin_caused_off indicates that this channel was turned off because VIN_SNS dropped below the VIN_OFF
threshold. Status_word_mfr and Status_word_high_byte are set at the same time, but ALERTB is not asserted. If
VIN_SNS subsequently rises above VIN_ON, and this channel turns back on, Mfr_status_2_vin_caused_off will remain
asserted to record the transient event regardless of the value of Mfr_config_all_vin_on_clr_faults_en.
2977f
62
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_TELEMETRY
This read-only command enables efficient polling of telemetry data for all output channels via a single 49 byte
block read.
MFR_TELEMETRY Data Block Contents
DATA
BYTE*
Status_word0[7:0]
0
Status_word0[15:8]
1
Status_vout0
2
Status_mfr0
3
Read_vout0[7:0]
4
Read_vout0[15:8]
5
Status_word1[7:0]
6
Status_word1[15:8]
7
Status_vout1
8
Status_mfr1
9
Read_vout1[7:0]
10
Read_vout1[15:8]
11
Status_word2[7:0]
12
Status_word2[15:8]
13
Status_vout2
14
Status_mfr2
15
Read_vout2[7:0]
16
Read_vout2[15:8]
17
Status_word3[7:0]
18
Status_word3[15:8]
19
Status_vout3
20
Status_mfr3
21
Read_vout3[7:0]
22
Read_vout3[15:8]
23
Status_word4[7:0]
24
Status_word4[15:8]
25
Status_vout4
26
Status_mfr4
27
Read_vout4[7:0]
28
Read_vout4[15:8]
29
Status_word5[7:0]
30
Status_word5[15:8]
31
Status_vout5
32
Status_mfr5
33
Read_vout5[7:0]
34
Read_vout5[15:8]
35
Status_word6[7:0]
36
Status_word6[15:8]
37
Status_vout6
38
Status_mfr6
39
Read_vout6[7:0]
40
Read_vout6[15:8]
41
Status_word7[7:0]
42
Status_word7[15:8]
43
Status_vout7
44
Status_mfr7
45
Read_vout7[7:0]
46
Read_vout7[15:8]
47
Reserved
48
*Note: PMBus data byte numbers start at 1 rather than 0. Status_word0[7:0]
is the first byte returned after BYTE COUNT = Ox31 See block read protocol.
2977f
For more information www.linear.com/LTC2977
63
LTC2977
PMBus Command Description
Watchdog Operation
A non zero write to the MFR_WATCHDOG_T register will reset the watchdog timer. Low-to-high transitions on the
WDI/RESETB pin also reset the watchdog timer. If the timer expires, ALERTB is asserted and the PWRGD output
is optionally deasserted and then reasserted after MFR_PWRGD_ASSERTION_DELAY ms. Writing 0 to either the
MFR_WATCH_DOG_T or MFR_WATCHDOG_T_FIRST registers will disable the timer.
MFR_WATCHDOG_T_FIRST and MFR_WATCHDOG_T
The MFR_WATCHDOG_T_FIRST register allows the user to program the duration of the first watchdog timer interval
following assertion of the PWRGD pin, assuming the PWRGD signal reflects the status of the watchdog timer. If
assertion of PWRGD is not conditioned by the watchdog timer’s status, then MFR_WATCHDOG_T_FIRST applies to
the first timing interval after the timer is enabled. Writing a value of 0ms to the MFR_WATCHDOG_T_FIRST register
disables the watchdog timer.
The MFR_WATCHDOG_T register allows the user to program watchdog time intervals subsequent to the MFR_
WATCHDOG_T_FIRST timing interval. Writing a value of 0ms to the MFR_WATCHDOG_T register disables the
watchdog timer. A non-zero write to MFR_WATCHDOG_T will reset the watchdog timer.
The read value of both commands always returns what was last written and does not reflect internal limiting.
MFR_WATCHDOG_T_POR and MFR_WATCHDOG_T Data Contents
BIT(S) SYMBOL
OPERATION
b[15:0] Mfr_watchdog_t_first The data uses the L11 format.
Mfr_watchdog_t
These timers operate on an internal clock. The Mfr_watchdog_t timer will align to SHARE_CLK if it is running.
Delays are rounded to the nearest 10µs for _t and 1ms for _t_first.
Writing a zero value for Y to the Mfr_watchdog_t or Mfr_watchdog_t_first registers will disable the watchdog timer.
Units: ms. Max timeout is 0.6 sec for _t and 65 sec for _t_first
2977f
64
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
Bulk Programming the User EEPROM Space
The MFR_EE_UNLOCK, MFR_EE_ERASE and MFR_EE_DATA commands provide a method for 3rd party EEPROM
programming houses and end users to easily program the LTC2977 independent of any order dependencies or delays
between PMBus commands. All data transfers are directly to and from the EEPROM and do not affect the volatile RAM
space currently configuring the device.
The first step is to program a master reference part with the desired configuration. MFR_EE_UNLOCK and MFR_EE_DATA
are then used to read back all the data in User EEPROM space as sequential words. This information is stored to the
master programming HEX file. Subsequent parts may be cloned to match the master part using MFR_EE_UNLOCK,
MFR_EE_ERASE and MFR_EE_DATA to transfer data from the master HEX file. These commands operate directly on
the EEPROM independent of the part configurations stored in RAM space. During EEPROM access the part will indicate
that it is busy as described below.
In order to support simple programming fixtures the bulk programming feature only uses PMBus word and byte
commands. The MFR_EE_UNLOCK configures the appropriate access mode and resets an internal address pointer
allowing a series of word commands to behave as a block read or write with the address pointer being incremented
after each operation. PEC use is optional and is configured by the MFR_EE_UNLOCK operation.
MFR_EE_UNLOCK
The MFR_EE_UNLOCK command prevents accidental EEPROM access in normal operation and configures the required
EEPROM bulk programming mode for bulk initialization, sequential writes, or reads. MFR_EE_UNLOCK augments the
protection provided by write protect. Upon unlocking the part for the required operation, an internal address pointer is
reset allowing a series of MFR_EE_DATA reads or writes to sequentially transfer data, similar to a block read or block
write. The MFR_EE_UNLOCK command can clear or set PEC mode based on the desired level of error protection. An
MFR_EE_UNLOCK sequence consists of writing two unlock codes using two byte-write commands. The following
table documents the allowed sequences. Writing a non-supported sequence locks the part. Reading MFR_EE_UNLOCK
returns the last byte written or zero if the part is locked.
MFR_EE_UNLOCK Data Contents
BIT(S) SYMBOL
OPERATION
b[7:0] Mfr_ee_unlock[7:0] To unlock user EEPROM space for Mfr_ee_erase and Mfr_ee_data read or write operations with PEC allowed:
Write 0x2b followed by 0xd4.
To unlock user EEPROM space for Mfr_ee_erase and Mfr_ee_data read or write operations with PEC required:
Write 0x2b followed by 0xd5.
To unlock user and manufacturer EEPROM space for Mfr_ee_data read only operations with PEC allowed:
Write 0x2b, followed by 0x91 followed by 0xe4.
To unlock user and manufacturer EEPROM space for Mfr_ee_data read only operations with PEC required:
Write 0x2b, followed by 0x91 followed by 0xe5.
2977f
For more information www.linear.com/LTC2977
65
LTC2977
PMBus Command Description
MFR_EE_ERASE
The MFR_EE_ERASE command is used to erase the entire contents of the user EEPROM space and configures this
space to accept new program data. Writing values other than 0x2B will lock the part. Reads return the last value written.
MFR_EE_ERASE Data contents
BIT(S) SYMBOL
OPERATION
b[7:0] Mfr_ee_erase[7:0] To erase the user EEPROM space and configure to accept new data:
1) Use the appropriate Mfr_ee_unlock sequence to configure for Mfr_ee_erase commands with or without PEC.
2) Write 0x2B to Mfr_ee_erase.
The part will indicate it is busy erasing the EEPROM by the mechanism detailed below.
MFR_EE_DATA
The MFR_EE_DATA command allows the user to transfer data directly to or from the EEPROM without affecting RAM
space.
To read the user EEPROM space issue the appropriate Mfr_ee_unlock command and perform Mfr_ee_data reads until
the EEPROM has been completely read. Extra reads will lock the part and return zero. The first read returns the 16-bit
EEPROM packing revision ID that is stored in ROM. The second read returns the number of 16-bit words available;
this is the number of reads or writes to access all memory locations. Subsequent reads return EEPROM data starting
with the lowest address.
To write to the user EEPROM space issue, the appropriate Mfr_ee_unlock and Mfr_ee_erase commands followed by
successive Mfr_ee_data word writes until the EEPROM is full. Extra writes will lock the part. The first write is to the
lowest address.
Mfr_ee_data reads and writes must not be mixed.
MFR_EE_DATA Data Contents
BIT(S) SYMBOL
OPERATION
b[7:0] Mfr_ee_data[7:0] To read user space
1) Use the appropriate Mfr_ee_unlock sequence to configure for Mfr_ee_data commands with or without PEC.
2) Read Mfr_ee_data[0] = PackingId (MFR Specific ID).
3) Read Mfr_ee_data[1] = NumberOfUserWords (total number of 16-bit word available).
4) Read Mfr_ee_data[2] through Mfr_ee_data[NumberOfUserWords+1] (User EEPROM data contents)
To write user space
1) Initialize the user memory using the sequence described for the MFR_EE_ERASE command.
2) Use the appropriate Mfr_ee_unlock sequence to configure for Mfr_ee_data commands with or without PEC.
3) Write Mfr_ee_data[0] through Mfr_ee_data[NumberOfUserWords-1] (User EEPROM data content to be written)
The part will indicate it is busy erasing the EEPROM by the mechanism detailed below.
2977f
66
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
Response When Part Is Busy
The part will indicate it is busy accessing the EEPROM by the following mechanism:
1) Clearing Mfr_common_busyb of the MFR_COMMON register. This byte can always be read and will never NACK a
byte read request even if the part is busy.
2) NACKing commands other than MFR_COMMON.
MFR_EE Erase and Write Programming Time
The program time per word is typically 0.17ms and will require spacing the I2C/SMBus writes at greater than 0.17ms
to guarantee the write has completed. The Mfr_ee_erase command takes approximately 400ms. We recommend using
MFR_COMMON for handshaking.
Fault Log Operation
A conceptual diagram of the fault log is shown in Figure 14. The fault log provides black box capability to the LTC2977.
During normal operation the contents of the status registers, the output voltage readings, temperature readings as
well as peak and min values of these quantities are stored in a continuously updated buffer in RAM. You can think of
the operation as being similar to a strip chart recorder. When a fault occurs, the contents are written into EEPROM for
nonvolatile storage. The EEPROM fault log is then locked. The part can be powered down with the fault log available
for reading at a later time.
MFR_FAULT_LOG_STORE
This command allows the user to transfer data from the RAM buffer to EEPROM.
MFR_FAULT_LOG_RESTORE
This command allows the user to transfer a copy of the fault-log data from the EEPROM to the RAM buffer. After a
restore the RAM buffer is locked until a successful MFR_FAULT_LOG read or MFR_FAULT_LOG_CLEAR.
2977f
For more information www.linear.com/LTC2977
67
LTC2977
PMBus Command Description
MFR_FAULT_LOG_CLEAR
This command initializes the EEPROM block reserved for fault logging. Any previous fault log stored in EEPROM will
be erased by this operation and logging of the fault log RAM to EEPROM will be enabled.
MFR_FAULT_LOG_STATUS
Read only. This register is used to manage fault log events.
Mfr_fault_log_status_eeprom is set after a MFR_FAULT_LOG_STORE command or a faulted-off event triggers a transfer
of the fault log from RAM to EEPROM. This bit is cleared by a MFR_FAULT_LOG_CLEAR command.
Mfr_fault_log_status_ram is set after a MFR_FAULT_LOG_RESTORE to indicate that the data in the RAM has been
restored from EEPROM and not yet read using a MFR_FAULT_LOG command. This bit is cleared by a successful
execution of an MFR_FAULT_LOG command, or by a successful execution of an MFR_FAULT_LOG_CLEAR command.
MFR_FAULT_LOG_STATUS Data Contents
BIT(S) SYMBOL
b[1]
Mfr_fault_log_status_ram
OPERATION
Fault log RAM status:
0: The fault log RAM allows updates.
1: The fault log RAM is locked until the next MFR_FAULT_LOG read.
b[0]
Mfr_fault_log_status_eeprom Fault log EEPROM status:
0: The transfer of the fault log RAM to the EEPROM is enabled.
1: The transfer of the fault log RAM to the EEPROM is inhibited.
RAM 255 BYTES
EEPROM 255 BYTES
8
ADC READINGS
CONTINUOUSLY
FILL BUFFER
TIME OF FAULT
TRANSFER TO
EEPROM AND
LOCK
...
...
AFTER FAULT
READ FROM
EEPROM AND
LOCK BUFFER
2977 F14
Figure 14. Fault Log Conceptual Diagram
2977f
68
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
MFR_FAULT_LOG
Read only. This 2040-bit (255 byte) data block contains a copy of the RAM buffer fault log. The RAM buffer is continuously
updated after each ADC conversion as long as Mfr_fault_log_status_ram is clear.
With Mfr_config_all_fault_log_enable = 1 and Mfr_fault_log_status_eeprom = 0, the RAM buffer is transferred to
EEPROM whenever an LTC2977 fault causes a channel to latch off or a MFR_FAULT_LOG_STORE command is received.
This transfer is delayed until the ADC has updated its READ values for all channels when Mfr_config_all_fast_fault_log
is clear, otherwise it happens within 24ms. This optional delay can be used to ensure that the slower, ADC monitored,
values are all updated for the case where a fast supervisor detected fault initiates the transfer to EEPROM.
Mfr_fault_log_status_eeprom is set high after the RAM buffer is transferred to EEPROM and not cleared until a
MFR_FAULT_LOG_CLEAR is received, even if the LTC2977 is reset or powered down. Fault log EEPROM transfers are
not initiated as a result of Status_mfr_discharge events.
During a MFR_FAULT_LOG read, data is returned as defined by the following table. The fault log data is partitioned into
two sections. The first section is referred to as the preamble and contains the Position-last pointer, time information
and peak and minimum values. The second section contains a chronological record of telemetry and requires Positionlast for proper interpretation. The fault log stores approximately 0.5 seconds of telemetry. To prevent timeouts during
block reads, it is recommended that Mfr_config_all_longer_pmbus_timeout be set to 1.
2977f
For more information www.linear.com/LTC2977
69
LTC2977
PMBus Command Description
Table 2. Data Block Contents
DATA
Position_last[7:0]
BYTE*
0
Cyclic_data_valid_count[7:0]
1
SharedTime[7:0]
SharedTime[15:8]
SharedTime[23:16]
SharedTime[31:24]
SharedTime[39:32]
SharedTime[40]
Mfr_vout_peak0[7:0]
Mfr_vout_peak0[15:8]
Mfr_vout_min0[7:0]
Mfr_vout_min0[15:8]
Mfr_vout_peak1[7:0]
Mfr_vout_peak1[15:8]
Mfr_vout_min1[7:0]
Mfr_vout_min1[15:8]
Mfr_vin_peak[7:0]
Mfr_vin_peak[15:8]
Mfr_vin_min[7:0]
Mfr_vin_min[15:8]
Mfr_vout_peak2[7:0]
Mfr_vout_peak2[15:8]
Mfr_vout_min2[7:0]
Mfr_vout_min2[15:8]
Mfr_vout_peak3[7:0]
Mfr_vout_peak3[15:8]
Mfr_vout_min3[7:0]
Mfr_vout_min3[15:8]
Mfr_temp_peak[7:0]
Mfr_temp_peak[15:8]
Mfr_ temp_min[7:0]
Mfr_ temp_min[15:8]
Mfr_vout_peak4[7:0]
Mfr_vout_peak4[15:8]
Mfr_vout_min4[7:0]
Mfr_vout_min4[15:8]
Mfr_vout_peak5[7:0]
Mfr_vout_peak5[15:8]
Mfr_vout_min5[7:0]
Mfr_vout_min5[15:8]
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
DESCRIPTION
Position of fault log pointer
when fault occurred.
Number of valid bytes of cyclic
data. 0xFF indicates all cyclic
data is valid.
41-bit share-clock counter
value when fault occurred.
Counter LSB is in 200µs
increments. This counter is
cleared at power-up or after
the LTC2977 is reset
Table 2. Data Block Contents
DATA
Mfr_vout_peak6[7:0]
Mfr_vout_peak6[15:8]
Mfr_vout_min6[7:0]
Mfr_vout_min6[15:8]
Mfr_vout_peak7[7:0]
Mfr_vout_peak7[15:8]
Mfr_vout_min7[7:0]
Mfr_vout_min7[15:8]
Status_vout0
Status_mfr0
Mfr_status_2_0[7:0]
Status_vout1
Status_mfr1
Mfr_status_2_1[7:0]
Status_vout2
Status_mfr2
Mfr_status_2_2[7:0]
Status_vout3
Status_mfr3
Mfr_status_2_3[7:0]
Status_vout4
Status_mfr4
Mfr_status_2_4[7:0]
Status_vout5
Status_mfr5
Mfr_status_2_5[7:0]
Status_vout6
Status_mfr6
Mfr_status_2_6[7:0]
Status_vout7
Status_mfr7
Mfr_status_2_7[7:0]
BYTE*
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
DESCRIPTION
Reserved bits[15:8] not stored
72 bytes for preamble
Fault_log [Position_last]
72
Start of cyclic data
Fault_log
73
.
.
.
Fault_log
237
Last Valid Byte
Reserved
238-254
Number of cyclic data loops: (238-72)/46 = 3.6
*Note: PMBus data byte numbers start at 1 rather than 0. Position_last is the
first byte returned after BYTE COUNT = 0xFF. See block read protocol.
2977f
70
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
The data returned between bytes 72 and 237 of the previous
table is interpreted using Position_last and the following
table. The key to identifying byte 72 is to locate the DATA
corresponding to POSITION = Position_last in the next
table. Subsequent bytes are identified by decrementing
the value of POSITION. For example: If Position_last = 11
then the first data returned in byte position 72 of a block
read is Read_vin[15:8] followed by Read_vin[7:0] followed
by Mfr_status_2 of page 1. See Table 3.
Table 3. Interpreting Cyclical Loop
POSITION
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
DATA
Read_vout0[7:0]
Read_vout0[15:8]
Status_vout0
Status_mfr0
Mfr_status_2_0[7:0]
Read_vout1[7:0]
Read_vout1[15:8]
Status_vout1
Status_mfr1
Mfr_status_2_1[7:0]
Read_vin[7:0]
Read_vin[15:8]
Status_vin
Read_vout2[7:0]
Read_vout2[15:8]
Status_vout2
Status_mfr2
Mfr_status_2_2[7:0]
Read_vout3[7:0]
Read_vout3[15:8]
Status_vout3
Status_mfr3
Mfr_status_2_3[7:0]
Read_temperature_1[7:0]
Read_temperature_1[15:8]
Status_temp
Read_vout4[7:0]
Read_vout4[15:8]
Status_vout4
Status_mfr4
Mfr_status_2_4[7:0]
Read_vout5[7:0]
Read_vout5[15:8]
Status_vout5
Table 3. Interpreting Cyclical Loop
POSITION
34
35
36
37
38
39
40
41
42
43
44
45
DATA
Status_mfr5
Mfr_status_2_5[7:0]
Read_vout6[7:0]
Read_vout6[15:8]
Status_vout6
Status_mfr6
Mfr_status_2_6[7:0]
Read_vout7[7:0]
Read_vout7[15:8]
Status_vout7
Status_mfr7
Mfr_status_2_7[7:0]
Total Bytes = 46
The following table fully decodes a sample fault log read
to help clarify the cyclical nature of the operation.
MFR_FAULT_LOG DATA BLOCK CONTENTS
PREAMBLE INFORMATION
BYTE
BYTE
NUMBER NUMBER
DECIMAL HEX
DATA
DESCRIPTION
0
00
Position_last[7:0] = 11 Position of
Fault‑Log Pointer
When Fault
Occurred.
1
01
Cyclic_data_valid_
count[7:0] = 160
Final 6 Bytes Of
Cyclic Data Not
Valid
2
02
SharedTime[7:0]
3
03
SharedTime[15:8]
4
04
SharedTime[23:16]
5
05
SharedTime[31:24]
6
06
SharedTime[39:32]
41-Bit ShareClock Counter
Value When Fault
Occurred. Counter
LSB Is in 200µs
Increments.
7
07
SharedTime[40]
8
08
Mfr_vout_peak0[7:0]
9
09
Mfr_vout_peak0[15:8]
10
0A
Mfr_vout_min0[7:0]
11
0B
Mfr_vout_min0[15:8]
12
0C
Mfr_vout_peak1[7:0]
13
0D
Mfr_vout_peak1[15:8]
14
0E
Mfr_vout_min1[7:0]
15
0F
Mfr_vout_min1[15:8]
2977f
For more information www.linear.com/LTC2977
71
LTC2977
PMBus Command Description
BYTE
BYTE
NUMBER NUMBER
DECIMAL HEX
DATA
DESCRIPTION
BYTE
BYTE
NUMBER NUMBER
DECIMAL HEX
DATA
16
10
Mfr_vin_peak[7:0]
52
34
Status_mfr1
17
11
Mfr_vin_peak[15:8]
53
35
Mfr_status_2_1[7:0]
18
12
Mfr_vin_min[7:0]
54
36
Status_vout2
19
13
Mfr_vin_min[15:8]
55
37
Status_mfr2
20
14
Mfr_vout_peak2[7:0]
56
38
Mfr_status_2_2[7:0]
21
15
Mfr_vout_peak2[15:8]
57
39
Status_vout3
22
16
Mfr_vout_min2[7:0]
58
3A
Status_mfr3
23
17
Mfr_vout_min2[15:8]
59
3B
Mfr_status_2_3[7:0]
24
18
Mfr_vout_peak3[7:0]
60
3C
Status_vout4
25
19
Mfr_vout_peak3[15:8]
61
3D
Status_mfr4
26
1A
Mfr_vout_min3[7:0]
62
3E
Mfr_status_2_4[7:0]
27
1B
Mfr_vout_min3[15:8]
63
3F
Status_vout5
28
1C
Mfr_temp_peak[7:0]
64
40
Status_mfr5
29
1D
Mfr_temp_peak[15:8]
65
41
Mfr_status_2_5[7:0]
30
1E
Mfr_ temp_min[7:0]
66
42
Status_vout6
31
1F
Mfr_ temp_min[15:8]
67
43
Status_mfr6
32
20
Mfr_vout_peak4[7:0]
68
44
Mfr_status_2_6[7:0]
33
21
Mfr_vout_peak4[15:8]
69
45
Status_vout7
34
22
Mfr_vout_min4[7:0]
70
46
Status_mfr7
35
23
Mfr_vout_min4[15:8]
71
47
36
24
Mfr_vout_peak5[7:0]
37
25
Mfr_vout_peak5[15:8]
38
26
Mfr_vout_min5[7:0]
39
27
Mfr_vout_min5[15:8]
40
28
Mfr_vout_peak6[7:0]
72
41
29
Mfr_vout_peak6[15:8]
42
2A
Mfr_vout_min6[7:0]
43
2B
44
2C
45
Mfr_status_2_7[7:0]
DESCRIPTION
End of Preamble
CYCLICAL DATA LOOPS
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
DATA LOOP 0
48
11
Read_vin[15:8]
73
49
10
Read_vin[7:0]
74
4A
9
Mfr_status_2_1[7:0]
Mfr_vout_min6[15:8]
75
4B
8
Status_mfr1
Mfr_vout_peak7[7:0]
76
4C
7
Status_vout1
2D
Mfr_vout_peak7[15:8]
77
4D
6
Read_vout1[15:8]
46
2E
Mfr_vout_min7[7:0]
78
4E
5
Read_vout1[7:0]
47
2F
Mfr_vout_min7[15:8]
79
4F
4
Mfr_status_2_0[7:0]
48
30
Status_vout0
80
50
3
Status_mfr0
49
31
Status_mfr0
81
51
2
Status_vout0
50
32
Mfr_status_2_0[7:0]
82
52
1
Read_vout0[15:8]
51
33
Status_vout1
83
53
0
Read_vout0[7:0]
46 BYTES PER
LOOP
Position_last
2977f
72
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
DATA LOOP 1
46 BYTES PER
LOOP
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
DATA LOOP 1
84
54
45
Mfr_status_2_7[7:0]
119
77
10
Read_vin[7:0]
85
55
44
Status_mfr7
120
78
9
Mfr_status_2_1[7:0]
86
56
43
Status_vout7
121
79
8
Status_mfr1
87
57
42
Read_vout7[15:8]
122
7A
7
Status_vout1
88
58
41
Read_vout7[7:0]
123
7B
6
Read_vout1[15:8]
89
59
40
Mfr_status_2_6[7:0]
124
7C
5
Read_vout1[7:0]
90
5A
39
Status_mfr6
125
7D
4
Mfr_status_2_0[7:0]
91
5B
38
Status_vout6
126
7E
3
Status_mfr0
92
5C
37
Read_vout6[15:8]
127
7F
2
Status_vout0
93
5D
36
Read_vout6[7:0]
128
80
1
Read_vout0[15:8]
94
5E
35
Mfr_status_2_5[7:0]
129
81
0
Read_vout0[7:0]
95
5F
34
Status_mfr5
96
60
33
Status_vout5
97
61
32
Read_vout5[15:8]
98
62
31
Read_vout5[7:0]
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
DATA LOOP 2
99
63
30
Mfr_status_2_4[7:0]
130
82
45
Mfr_status_2_7[7:0]
100
64
29
Status_mfr4
131
83
44
Status_mfr7
101
65
28
Status_vout4
132
84
43
Status_vout7
102
66
27
Read_vout4[15:8]
133
85
42
Read_vout7[15:8]
103
67
26
Read_vout4[7:0]
134
86
41
Read_vout7[7:0]
104
68
25
Status_temp
135
87
40
Mfr_status_2_6[7:0]
105
69
24
Read_
temperature_1[15:8]
136
88
39
Status_mfr6
137
89
38
Status_vout6
138
8A
37
Read_vout6[15:8]
139
8B
36
Read_vout6[7:0]
140
8C
35
Mfr_status_2_5[7:0]
141
8D
34
Status_mfr5
142
8E
33
Status_vout5
143
8F
32
Read_vout5[15:8]
144
90
31
Read_vout5[7:0]
145
91
30
Mfr_status_2_4[7:0]
146
92
29
Status_mfr4
147
93
28
Status_vout4
148
94
27
Read_vout4[15:8]
149
95
26
Read_vout4[7:0]
150
96
25
Status_temp
106
6A
23
Read_
temperature_1[7:0]
107
6B
22
Mfr_status_2_3[7:0]
108
6C
21
Status_mfr3
109
6D
20
Status_vout3
110
6E
19
Read_vout3[15:8]
111
6F
18
Read_vout3[7:0]
112
70
17
Mfr_status_2_2[7:0]
113
71
16
Status_mfr2
114
72
15
Status_vout2
115
73
14
Read_vout2[15:8]
116
74
13
Read_vout2[7:0]
117
75
12
Status_vin
118
76
11
Read_vin[15:8]
46 BYTES PER
LOOP
46 BYTES PER
LOOP
2977f
For more information www.linear.com/LTC2977
73
LTC2977
PMBus Command Description
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
151
152
97
98
24
23
DATA LOOP 2
46 BYTES PER
LOOP
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
DATA LOOP 3
Read_
temperature_1[15:8]
182
B6
39
Status_mfr6
Read_
temperature_1[7:0]
183
B7
38
Status_vout6
184
B8
37
Read_vout6[15:8]
185
B9
36
Read_vout6[7:0]
186
BA
35
Mfr_status_2_5[7:0]
187
BB
34
Status_mfr5
188
BC
33
Status_vout5
189
BD
32
Read_vout5[15:8]
190
BE
31
Read_vout5[7:0]
191
BF
30
Mfr_status_2_4[7:0]
192
C0
29
Status_mfr4
193
C1
28
Status_vout4
194
C2
27
Read_vout4[15:8]
195
C3
26
Read_vout4[7:0]
196
C4
25
Status_temp
197
C5
24
Read_
temperature_1[15:8]
198
C6
23
Read_
temperature_1[7:0]
153
99
22
Mfr_status_2_3[7:0]
154
9A
21
Status_mfr3
155
9B
20
Status_vout3
156
9C
19
Read_vout3[15:8]
157
9D
18
Read_vout3[7:0]
158
9E
17
Mfr_status_2_2[7:0]
159
9F
16
Status_mfr2
160
A0
15
Status_vout2
161
A1
14
Read_vout2[15:8]
162
A2
13
Read_vout2[7:0]
163
A3
12
Status_vin
164
A4
11
Read_vin[15:8]
165
A5
10
Read_vin[7:0]
166
A6
9
Mfr_status_2_1[7:0]
167
A7
8
Status_mfr1
168
A8
7
Status_vout1
199
C7
22
Mfr_status_2_3[7:0]
169
A9
6
Read_vout1[15:8]
200
C8
21
Status_mfr3
170
AA
5
Read_vout1[7:0]
201
C9
20
Status_vout3
171
AB
4
Mfr_status_2_0[7:0]
202
CA
19
Read_vout3[15:8]
172
AC
3
Status_mfr0
203
CB
18
Read_vout3[7:0]
173
AD
2
Status_vout0
204
CC
17
Mfr_status_2_2[7:0]
174
AE
1
Read_vout0[15:8]
205
CD
16
Status_mfr2
175
AF
0
Read_vout0[7:0]
206
CE
15
Status_vout2
207
CF
14
Read_vout2[15:8]
208
D0
13
Read_vout2[7:0]
209
D1
12
Status_vin
210
D2
11
Read_vin[15:8]
D3
10
Read_vin[7:0]
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
DATA LOOP 3
46 BYTES PER
LOOP
176
B0
45
Mfr_status_2_7[7:0]
211
177
B1
44
Status_mfr7
212
D4
9
Mfr_status_2_1[7:0]
178
B2
43
Status_vout7
213
D5
8
Status_mfr1
D6
7
Status_vout1
179
B3
42
Read_vout7[15:8]
214
180
B4
41
Read_vout7[7:0]
215
D7
6
Read_vout1[15:8]
Mfr_status_2_6[7:0]
216
D8
5
Read_vout1[7:0]
181
B5
40
46 BYTES PER
LOOP
2977f
74
For more information www.linear.com/LTC2977
LTC2977
PMBus Command Description
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
RESERVED BYTES
DATA LOOP 3
217
D9
4
Mfr_status_2_0[7:0]
218
DA
3
Status_mfr0
219
DB
2
Status_vout0
220
DC
1
Read_vout0[15:8]
221
DD
0
Read_vout0[7:0]
LOOP
BYTE
BYTE
BYTE
NUMBER NUMBER NUMBER
DECIMAL HEX DECIMAL
DATA LOOP 4
46 BYTES PER
LOOP
46 BYTES PER
LOOP
238
EE
0x00
239
EF
0x00
240
F0
0x00
241
F1
0x00
242
F2
0x00
243
F3
0x00
244
F4
0x00
245
F5
0x00
246
F6
0x00
247
F7
0x00
F8
0x00
222
DE
45
Mfr_status_2_7[7:0]
248
223
DF
44
Status_mfr7
249
F9
0x00
224
E0
43
Status_vout7
250
FA
0x00
225
E1
42
Read_vout7[15:8]
251
FB
0x00
226
E2
41
Read_vout7[7:0]
252
FC
0x00
227
E3
40
Mfr_status_2_6[7:0]
253
FD
0x00
228
E4
39
Status_mfr6
254
FE
0x00
229
E5
38
Status_vout6
230
E6
37
Read_vout6[15:8]
231
E7
36
Read_vout6[7:0]
232
E8
35
Mfr_status_2_5[7:0]
Invalid data
233
E9
34
Status_mfr5
Invalid data
234
EA
33
Status_vout5
Invalid data
235
EB
32
Read_vout5[15:8]
Invalid data
236
EC
31
Read_vout5[7:0]
Invalid data
237
ED
30
Mfr_status_2_4[7:0]
Invalid data
Bytes EE - FE
Return 0x00 But
Must Be Read
Use One Block
Read Command
to Read 255 Bytes
Total, from 0x00
to 0xFE
2977f
For more information www.linear.com/LTC2977
75
LTC2977
Applications Information
Overview
The LTC2977 is a power management IC that is capable
of sequencing, margining, trimming, supervising output
voltage for OV/UV conditions, providing fault management,
and voltage readback for eight DC/DC converters. Input
voltage and LTC2977 junction temperature readback are
also available. Odd numbered channels can be configured
to read back sense resistor voltages to provide current
measurements for those channels. Linear Technology
Power System Managers can coordinate operation among
multiple devices using common SHARE_CLK, FAULTB and
CONTROL pins. The LTC2977 utilizes a PMBus compliant
interface and command set.
Powering the LTC2977
The LTC2977 can be powered two ways. The first method
requires that a voltage between 4.5V and 15V be applied
to the VPWR pin. See Figure 15. An internal linear regulator converts VPWR down to 3.3V which drives all of the
internal circuitry of the LTC2977.
4.5V < VPWR < 15V
0.1µF
0.1µF
VPWR
VIN_SNS
VDD33
VDD33
VDD25
LTC2977*
0.1µF
GND
2977 F15
*SOME DETAILS
OMITTED FOR CLARITY
Figure 15. Powering LT2977 Directly from an Intermediate Bus
Alternatively, power from an external 3.3V supply may
be applied directly to the VDD33 pins 16 and 17 using a
voltage between 3.13V and 3.47V. Tie VPWR to VDD33 pins.
See Figure 16. All functionality is available when using
this alternate power method. The higher voltages needed
for the VOUT_EN[0:3] pins and bias for the VSENSE pins are
charge-pumped from VDD33.
Setting Command Register Values
The command register settings described herein are intended as a reference and for the purpose of understanding
the registers in a software development environment. In
actual practice, the LTC2977 can be completely configured
for standalone operation with the LTC USB to I2C/SMBus/
PMBus controller (DC1613) and software GUI using intuitive menu driven objects.
Sequence, Servo, Margin and Restart
Operations
Command Units On or Off
Three control parameters determine how a particular
channel is turned on and off. The CONTROL pins, the
OPERATION command and the value of the input voltage
measured at the VIN_SNS pin (VIN). In all cases, VIN
must exceed VIN_ON in order to enable the device to
respond to the CONTROL pin or OPERATION command.
When VIN drops below VIN_OFF an immediate OFF or
sequence off after TOFF_DELAY of all channels will result
(See Mfr_config_chan_mode). Refer to the OPERATION
section in the data sheet for a detailed description of the
ON_OFF_CONFIG command.
Some examples of typical ON/OFF configurations are:
EXTERNAL 3.3V
0.1µF
1. A DC/DC converter may be configured to turn on anytime
VIN exceeds VIN_ON.
VPWR
VDD33
VDD33
2. A DC/DC converter may be configured to turn on only
when it receives an OPERATION command.
LTC2977*
VDD25
0.1µF
GND
2977 F16
*SOME DETAILS
OMITTED FOR CLARITY
Figure 16. Powering LTC2977 from External 3.3V Supply
3. A DC/DC converter may be configured to turn on only
via the CONTROL pin.
4. A DC/DC converter may be configured to turn on only
when it receives an OPERATION command and the
CONTROL pin is asserted.
2977f
76
For more information www.linear.com/LTC2977
LTC2977
APPLICATIONS INFORMATION
On Sequencing
Servo Modes
The TON_DELAY command sets the amount of time that
a channel will wait following the start of an ON sequence
before its VOUT_EN pin will enable a DC/DC converter. Once
the DC/DC converter has been enabled, the TON_RISE value
determines the time at which the device soft-connects
the DAC and servos the DC/DC converter output to the
VOUT_COMMAND value. The TON_MAX_FAULT_LIMIT
value determines the time at which the device checks
for an undervoltage condition. If a TON_MAX_FAULT
occurs, the channel can be configured to disable the DC/
DC converter and propagate the fault to other channels
using the bidirectional FAULTB pins. Note that overvoltage
faults are checked against the VOUT_OV_FAULT_LIMIT
at all times the device is powered up and not in a reset
state nor margining while ignoring OVs. Figure 17 shows
a typical on-sequence using the CONTROL pin.
The ADC, DAC and internal processor comprise a digital
servo loop that can be configured to operate in several
useful modes. The servo target refers to the desired output
voltage.
On State Operation
Once a channel has reached the ON state, the OPERATION
command can be used to command the DC/DC converter’s
output to margin high, margin low, or return to a nominal
output voltage indicated by VOUT_COMMAND. The
user also has the option of configuring a channel to
continuously trim the output of the DC/DC converter to the
VOUT_COMMAND voltage, or the channel’s VDACPn output
can be placed in a high impedance state thus allowing the
DC/DC converter output voltage to go to its nominal value,
VDCn(NOM). Refer to the MFR_CONFIG_LTC2977 command
for details on how to configure the output voltage servo.
VCONTROL
VOUT_EN
VOUT_0V_FAULT_LIMIT
DAC SOFT-CONNECTS
AND BEGINS
ADJUSTING OUTPUT
VOUT_COMMAND
VDC(NOM)
VOUT_UV_FAULT_LIMIT
VOUT
2977 F17
TON_DELAY
Continuous/noncontinuous trim mode. MFR_CONFIG_
LTC2977 b[7]. In continuous trim mode, the servo will
update the DAC in a closed loop fashion each time it
takes a VOUT reading. The update rate is determined by
the time it takes to step through the ADC MUX which is
no more than tUPDATE_ADC. See Electrical Characteristics
Table Note 6. In noncontinuous trim mode, the servo will
drive the DAC until the ADC measures the output voltage
desired and then stop updating the DAC.
As part of continuous/noncontinuous trim mode, fast servo
mode can be used to speed up large output transitions,
such as margin commands, or ON events. To use, set
Mfr_config_fast_servo_off=0. When enabled, fast servo
is started by a change to the target voltage or a new softconnect. The DAC is ramped one lsb every tS_VDACP period
until it is near the new target voltage, at which point slow
servo mode is entered to avoid overshoot.
Noncontinuous servo on warn mode. MFR_CONFIG_
LTC2977 b[7] = 0, b[6] = 1. When in noncontinuous mode,
the LTC2977 will retrim (reservo) the output if the output
drifts beyond the OV or UV warn limits.
DAC Modes
The DACs that drive the VDACn pins can operate in several
useful modes. See MFR_CONFIG_LTC2977.
• Soft-connect. Using the LTC patented soft-connect
feature, the DAC output is driven to within 1 LSB of the
voltage at the DC/DC’s feedback node before connecting,
to avoid introducing transients on the output. This
mode is used when servoing the output voltage. During
start-up, the LTC2977 waits until TON_RISE has expired
before connecting the DAC. This is the most common
operating mode.
• Disconnected. DAC output is high Z.
TON_RISE
TON_MAX_FAULT_LIMIT
Figure 17. Typical On Sequence Using Control Pin
2977f
For more information www.linear.com/LTC2977
77
LTC2977
APPLICATIONS INFORMATION
• DAC manual with soft-connect. Non servo mode. The
DAC soft-connects to the feedback node. Soft-connect
drives the DAC code to match the voltage at the feedback
node. After connection, the DAC is moved by writing
DAC codes to the MFR_DAC register.
• DAC manual with hard-connect. Non servo mode. The
DAC hard-connects to the feedback node using the
current value in MFR_DAC. After connection, the DAC is
moved by writing DAC codes to the MFR_DAC register.
Margining
The LTC2977 margins and trims the output of a DC/DC
converter by forcing a voltage across an external resistor
connected between the DAC output and the feedback node
or the trim pin. Preset limits for margining are stored in
the VOUT_MARGIN_HIGH/LOW registers. Margining is
actuated by writing the appropriate bits to the OPERATION register.
Margining requires the DAC to be connected. Margin
requests that occur when the DAC is disconnected will
be ignored.
Automatic Restart Via MFR_RESTART_DELAY
Command and CONTROLn pin
An automatic restart sequence can be initiated by driving
the CONTROL pin to the off state for >10μs then releasing
it. The automatic restart disables all VOUT_EN pins that are
mapped to a particular CONTROL pin for a time period
= MFR_RESTART_DELAY and then starts all DC-DC
Converters according to their respective TON_DELAYs.
(See Figure 18). VOUT_ENn pins are mapped to one of the
CONTROL pins by the MFR_CONFIG_LTC2977 command.
This feature allows a host that is about to reset to restart
the power in a controlled manner after it has recovered.
CONTROL
PIN BOUNCE
VCONTROL
VOUT_END
2977 F18
TOFF_DELAY0
MFR_RESTART_DELAY
TON_DELAY0
Figure 18. Off Sequence with Automatic Restart
Off Sequencing
Fault Management
An off sequence is initiated using the CONTROL pin or the
OPERATION command. The TOFF_DELAY value determines
the amount of time that elapses from the beginning of the
off sequence until each channel’s VOUT_EN pin is pulled
low, thus disabling its DC/DC converter.
Output Overvoltage and Undervoltage Faults
VOUT Off Threshold Voltage
The MFR_VOUT_DISCHARGE_THRESHOLD command
register allows the user to specify the OFF threshold that
the output voltage must decay below before the channel
can enter/re-enter the ON state. The OFF threshold voltage
is specified by multiplying MFR_VOUT_DISCHARGE_
THRESHOLD and VOUT_COMMAND. In the event that an
output voltage has not decayed below its OFF threshold
before attempting to enter the ON state, the channel will
continue to be held off, the appropriate bit is set in the
STATUS_MFR_SPECIFIC register, and the ALERTB pin
will be asserted low. When the output voltage has decayed
below its OFF threshold, the channel can enter the ON state.
The high speed voltage supervisor OV and UV fault
thresholds are configured using the VOUT_OV_FAULT_
LIMIT and VOUT_UV_FAULT_LIMIT commands,
respectively. The VOUT_OV_FAULT_RESPONSE and
VOUT_UV_FAULT_RESPONSE commands determine the
responses to OV/UV faults. Fault responses can range from
disabling the DC/DC converter immediately, waiting to
see if the fault condition persists for some interval before
disabling the DC/DC converter, or allowing the DC/DC
converter to continue operating in spite of the fault. If a DC/
DC converter is disabled, the LTC2977 can be configured
to retry one to six times, retry continuously without
limitation, or latch-off. The retry interval is specified using
the MFR_RETRY_DELAY command. Latched faults are
reset by toggling the CONTROL pin, using the OPERATION
command, or removing and reapplying the bias voltage to
the VIN_SNS pin. All fault and warning conditions result in
2977f
78
For more information www.linear.com/LTC2977
LTC2977
APPLICATIONS INFORMATION
the ALERTB pin being asserted low and the corresponding
bits being set in the status registers. The CLEAR_FAULTS
command resets the contents of the status registers and
deasserts the ALERTB output.
Output Overvoltage and Undervoltage Warnings
OV and UV warning threshold voltages are processed by the
LTC2977’s ADC. These thresholds are set by the VOUT_OV_
WARN_LIMIT and VOUT_UV_WARN_LIMIT commands
respectively. If a warning occurs, the corresponding bits
are set in the status registers and the ALERTB output
is asserted low. Note that a warning will never cause a
VOUT_EN output pin to disable a DC/DC converter.
Configuring the VIN_EN Output
The VIN_EN output may be used to disable the intermediate
bus voltage in the event of an output OV or UV fault.
Use the MFR_VINEN_OV_FAULT_RESPONSE and
MFR_VINEN_UV_FAULT_RESPONSE registers to
configure the VIN_EN pin to assert low in response to
VOUT_OV/UV fault conditions. The VIN_EN output will stop
RSENSE
0.007Ω
VIN
<15V
pulling low when the LTC2977 is commanded to re-enter
the ON state following a faulted-off condition.
A charge-pumped 5µA pull-up to 12V is also available on the
VIN_EN output. Refer to the MFR_CONFIG_ALL_LTC2977
register description in the PMBus COMMAND DESCRIPTION section for more information.
Figure 19 shows an application circuit where the VIN_EN
output is used to trigger an SCR crowbar on the intermediate
bus in order to protect the DC/DC converter’s load from a
catastrophic fault such as a stuck top gate. The stuck top
gate causes an OV fault, which in turn causes the LTC2977
to pull VIN_EN low, thus deasserting the ON input to the
LTC4210 hot-swap controller, which opens the switch Q1
that supplies the DC/DC converter input. In addition, when
VIN_EN goes low it forces the MCR12DC SCR device into
the on-state via the 2N2907 PNP, thus quickly dropping
the voltage on the VIN input to the DC/DC converter, preventing the stuck top gate from damaging components
supplied by this converter. Note that the VPWR input to
the LTC2977 bypasses switch Q1, keeping the LTC2977
fully powered throughout the above sequence.
Q1
Si4894BDY
VIN
CBYPASS
VIN_SNS
VPWR
VCC
GATE
LTC4210-3
24.3k
10k
SENSE
ON
TIMER GND
100Ω
LTC2977*
LOAD
VFB
VDACM0
0.01µF
0.22µF
VSENSEM0
SGND
VOUT_EN0
RUN/SS
GND
10k
2N2907
4.99k
DC/DC
CONVERTER
VSENSEP0
0.1µF
68Ω
0.01µF
VOUT
VDACP0
2977 F19
MCR12DC
220Ω
0.1µF
BAT54
REFP
VIN_EN
REFM
VDD33 VDD33 VDD25
GND
0.1µF
*SOME DETAILS OMITTED FOR CLARITY
ONLY ONE OF EIGHT CHANNELS SHOWN
0.1µF
Figure 19. LTC2977 Application Circuit with Crowbar Protection on Intermediate Bus
2977f
For more information www.linear.com/LTC2977
79
LTC2977
APPLICATIONS INFORMATION
Mfr_faultb00_response, page = 0
Mfr_faultb01_response, page = 0
CHANNEL 0
EVENT PROCESSOR
PAGE = 0
Mfr_faultb00_response, page = 1
Mfr_faultb01_response, page = 1
CHANNEL 1
EVENT PROCESSOR
PAGE = 1
Mfr_faultb00_response, page = 2
Mfr_faultb01_response, page = 2
CHANNEL 2
EVENT PROCESSOR
PAGE = 2
Mfr_faultb00_response, page = 3
Mfr_faultb01_response, page = 3
CHANNEL 3
EVENT PROCESSOR
PAGE = 3
Mfr_faultbz0_propagate_ch0
FAULTED_OFF
Mfr_faultbz1_propagate_ch0
FAULTB00
Mfr_faultbz0_propagate_ch1
FAULTED_OFF
Mfr_faultbz1_propagate_ch1
Mfr_faultbz0_propagate_ch2
FAULTED_OFF
FAULTB01
Mfr_faultbz1_propagate_ch2
Mfr_faultbz0_propagate_ch3
FAULTED_OFF
Mfr_faultbz1_propagate_ch3
ZONE 0
ZONE 0
ZONE 1
ZONE 1
Mfr_faultb10_response, page = 4
Mfr_faultb11_response, page = 4
CHANNEL 4
EVENT PROCESSOR
PAGE = 4
Mfr_faultb10_response, page = 5
Mfr_faultb11_response, page = 5
CHANNEL 5
EVENT PROCESSOR
PAGE = 5
Mfr_faultb10_response, page = 6
Mfr_faultb11_response, page = 6
CHANNEL 6
EVENT PROCESSOR
PAGE = 6
Mfr_faultb10_response, page = 7
Mfr_faultb11_response, page = 7
CHANNEL 7
EVENT PROCESSOR
PAGE = 7
Mfr_faultbz0_propagate_ch4
FAULTED_OFF
Mfr_faultbz1_propagate_ch4
FAULTB10
Mfr_faultbz0_propagate_ch5
FAULTED_OFF
Mfr_faultbz1_propagate_ch5
Mfr_faultbz0_propagate_ch6
FAULTED_OFF
FAULTB11
Mfr_faultbz1_propagate_ch6
Mfr_faultbz0_propagate_ch7
FAULTED_OFF
Mfr_faultbz1_propagate_ch7
2977 F20
Figure 20. Channel Fault Management Block Diagram
2977f
80
For more information www.linear.com/LTC2977
LTC2977
APPLICATIONS INFORMATION
Multichannel Fault Management
Multichannel fault management is handled using the
bidirectional FAULTBzn pins. The “z” designates the fault
zone which is either 0 or 1. There are two fault zones in
the LTC2977. Each zone contains 4-channels. Figure 20
illustrates the connections between channels and the
FAULTBzn pins.
• A FAULTBzn pin can also be asserted low by an external
driver in order to initiate an off-sequence after a 10µs
deglitch delay.
Interconnect Between Multiple LTC2977’s
Figure 21 shows how to interconnect the pins in a typical
multi-LTC2977 array.
• The MFR_FAULTBz0_PROPAGATE command acts like a
programmable switch that allows faulted-off conditions
from a particular channel (PAGE) to propagate to
either FAULTBzn output in that channel’s zone. The
MFR_FAULTBzn_RESPONSE command controls similar
switches on the inputs to each channel that allow any
channel to shut down in response to any combination
of the FAULTBzn pins within a zone. Channels responding to a FAULTBzn pin pulling low will attempt a new
start sequence when the FAULTBzn pin in question is
released by the faulted channel.
• All VIN_SNS lines should be tied together in a star type
connection at the point where VIN is to be sensed.
This will minimize timing errors for the case where the
ON_OFF_CONFIG is configured to start the LTC2977
based on VIN and ignore the CONTROL line and the
OPERATION command. In multi-part applications that
are sensitive to timing differences, it is recommended
that the Vin_share_enable bit of the MFR_CONFIG_
ALL_LTC2977 register be set high in order to allow
SHARE_CLK to synchronize on/off sequencing in
response to the VIN_ON and VIN_OFF thresholds.
• To establish dependencies across fault zones, tie the
fault pins together, e.g., FAULTB01 to FAULTB10. Any
channel can depend on any other. To disable all channels
in response to any channel faulting off, short all the
FAULTBzn pins together, and set MFR_FAULTBzn_
PROPAGATE = 0x01 and MFR_FAULTBzn_RESPONSE
= 0x0F for all channels.
• Connecting all VIN_EN lines together will allow selected
faults on any DC/DC converter’s output in the array to
shut off a common input switch.
• ALERTB is typically one line in an array of PMBus converters. The LTC2977 allows a rich combination of faults
and warnings to be propagated to the ALERTB pin.
TO VIN OF
DC/DCs TO HOST CONTROLLER
TO INPUT
SWITCH
LTC2977 N-1
VIN_SNS
VIN_EN
LTC2977 N
VIN_SNS
VIN_EN
SDA
SCL
ALERTB
CONTROL0
CONTROL1
WDI/RESETB
FAULTB00
FAULTB01
FAULTB10
FAULTB11
SHARE_CLK
PWRGD
GND
SDA
SCL
ALERTB
CONTROL0
CONTROL1
WDI/RESETB
FAULTB00
FAULTB01
FAULTB10
FAULTB11
SHARE_CLK
PWRGD
GND
TO OTHER LTC2977s–10k EQUIV PULL-UP RECOMMENDED
ON EACH LINE EXCEPT SHARE_CLK (USE 5.49k)
2977 F21
Figure 21. Typical Connections Between Multiple LTC2977s
2977f
For more information www.linear.com/LTC2977
81
LTC2977
APPLICATIONS INFORMATION
• WDI/RESETB can be used to put the LTC2977 in the
power-on reset state. Pull WDI/RESETB low for at least
tRESETB to enter this state.
Application Circuits
Trimming and Margining DC/DC Converters with
External Feedback Resistors
• The FAULTBzn lines can be connected together to create
fault dependencies. Figure 21 shows a configuration
where a fault on any FAULTBzn will pull all others low.
This is useful for arrays where it is desired to abort a
start-up sequence in the event any channel does not
come up (see Figure 22).
Figure 23 shows a typical application circuit for trimming/
margining a power supply with an external feedback
network. The VSENSEP0 and VSENSEM0 differential inputs
sense the load voltage directly, and a correction voltage
is developed between the VDACP0 and VDACM0 pins
by the closed-loop servo algorithm. VDACM0 is Kelvin
connected to the point-of-load GND in order to minimize
the effects of load induced grounding errors. The VDACP0
output is connected to the DC/DC converter’s feedback
node through resistor R30. For this configuration, set
Mfr_config_dac_pol to 0.
• PWRGD reflects the status of the outputs that are
mapped to it by the MFR_PWRGD_EN command. Figure 20 shows all the PWRGD pins connected together,
but any combination may be used.
VCONTROLn
VOUT0
TON_DELAY0
VOUT1
TON_DELAY1
VOUT2
TON_DELAY2
•
•
•
VOUTn
•
•
•
TON_DELAYn
BUSSED
VFAULTBzn
PINS
2977 F22
TON_MAX_FAULT1
Figure 22. Aborted On Sequence Due to Channel 1 Short
VIN
4.5V < VIBUS < 15V
0.1µF
0.1µF
VIN
VPWR
VIN_SNS
VOUT
VDACP0
VDD33
VDD33
VDD25
R30
VSENSEP0
LTC2977*
DC/DC
CONVERTER
VFB
LOAD
VDACM0
0.1µF
R20
R10
VSENSEM0
SGND
VOUT_EN0
RUN/SS
GND
2977 F23
GND
*SOME DETAILS OMITTED FOR CLARITY
ONLY ONE OF EIGHT CHANNELS SHOWN
Figure 23. Application Circuit for DC/DC Converters with External Feedback Resistors
2977f
82
For more information www.linear.com/LTC2977
LTC2977
APPLICATIONS INFORMATION
Four-Step Resistor Selection Procedure for DC/DC
Converters with External Feedback Resistors
The DAC has two full-scale settings, 1.38V and 2.65V.
In order to select the appropriate full-scale setting,
calculate the minimum required VDACP0(F/S) output
voltage:
The following four-step procedure should be used to
calculate the resistor values required for the application
circuit shown in Figure 23.
1. Assume values for feedback resistor R20 and the nominal
DC/DC converter output voltage VDC(NOM), and solve
for R10.
VDC(NOM) is the output voltage of the DC/DC converter
when the LTC2977’s VDACP0 pin is in a high impedance
state. R10 is a function of R20, VDC(NOM), the voltage at
the feedback node (VFB) when the loop is in regulation,
and the feedback node’s input current (IFB).
R20 • VFB
R10 =
VDC(NOM) – IFB • R20 – VFB
(1)
2. Solve for the value of R30 that yields the maximum
required DC/DC converter output voltage VDC(MAX).
When VDACP0 is at 0V, the output of the DC/DC converter
is at its maximum voltage.
R20 • VFB
R30 ≤
VDC(MAX) – VDC(NOM)
(2)
3. Solve for the minimum value of VDACP0 that is needed
to yield the minimum required DC/DC converter output
voltage VDC(MIN).
(
0.1µF
R30
+ VFB (3)
R20
4. Recalculate the minimum, nominal, and maximum DC/
DC converter output voltages and the resulting margining resolution.
 R20 
VDC(NOM) = VFB •  1+
+ I • R20
 R10  FB
(4)
R20
• VDACP0(F /S) – VFB
R30
R20
VDC(MAX) = VDC(NOM) +
• VFB
R30
R20
• VDACP0(F /S)
VRES = R30
V/DAC LSB
1024
(
VDC(MIN) = VDC(NOM) –
)
(5)
(6)
(7)
Trimming and Margining DC/DC Converters with a
TRIM Pin
Figure 24 illustrates a typical application circuit for
trimming/margining the output voltage of a DC/DC
converter with a TRIM Pin. The LTC2977’s VDACP0 pin
connects to the TRIM pin through resistor R30, and the
VDACM0 pin is connected to the converter’s point-of-load
VIN
4.5V < VIBUS < 15V
0.1µF
)
VDACP0(F /S) > VDC(NOM) – VDC(MIN) •
VIN
VPWR
VIN_SNS
VDD33
VSENSEP0
R30
VDACP0
VDD33
VDD25
LTC2977*
TRIM
VSENSE+
LOAD
VDACM0
0.1µF
VOUT+
DC/DC
CONVERTER
VSENSEM0
VSENSE–
VOUT_EN0
ON/OFFB
GND
GND
2977 F24
*SOME DETAILS OMITTED FOR CLARITY
ONLY ONE OF EIGHT CHANNELS SHOWN
Figure 24. Application Circuit for DC/DC Converters with Trim Pin
2977f
For more information www.linear.com/LTC2977
83
LTC2977
APPLICATIONS INFORMATION
ground. For this configuration, set the DAC polarity bit
Mfr_config_ dac_pol in MFR_CONFIG_LTC2977 to 1.
DC/DC converters with a TRIM pin may be margined
high or low by connecting an external resistor between
the TRIM pin and either the VSENSEP or VSENSEM pin. The
relationships between these resistors and the ∆% change
in the output voltage of the DC/DC converter are typically
expressed as:
RTRIM_DOWN =
RTRIM • 50
– RTRIM
ΔDOWN %
(8)
RTRIM_UP =
 V • (100 + Δ %)  50  
DC
UP
RTRIM • 
–
 – 1
 2 • VREF • ΔUP %
 ΔUP %  
(9)
Two-Step Resistor and DAC Full-Scale Voltage
Selection Procedure for DC/DC Converters with a
TRIM Pin
The following two-step procedure should be used to calculate the resistor value for R30 and the required full-scale
DAC voltage (refer to Figure 24).
1. Solve for R30:
(10)
2. Calculate the maximum required output voltage for
VDACP0:

Δ % 
VDACP0 ≥ 1+ UP
 • VREF
 ΔDOWN % 
Odd numbered ADC channels may be used to measure
supply current. Set the ADC to high resolution mode to
configure for current measuring and improve sensitivity.
Note that no OV or UV faults or warnings are reported in
this mode, but telemetry is available from the READ_VOUT
command using the 11-bit signed mantissa plus 5-bit
signed exponent L11 data format. Set the MFR_CONFIG_
LTC2977 bit b[9] = 1 in order to enable high res mode.
The VOUT_EN pin will assert low in this mode and cannot
be used to control a DC/DC converter. The VDACP output
pin is also unavailable.
Measuring Current with a Sense Resistor
where RTRIM is the resistance looking into the TRIM pin,
VREF is the TRIM pin’s open-circuit output voltage and VDC
is the DC/DC converter’s nominal output voltage. ∆UP% and
∆DOWN% denote the percentage change in the converter’s
output voltage when margining up or down, respectively.
 50 – Δ

DOWN % 
R30 ≤ RTRIM • 
 ΔDOWN % 
Measuring Current
A circuit for measuring current with a sense resistor is
shown in Figure 25. The balanced filter rejects both common mode and differential mode noise from the output of
the DC/DC converter. The filter is placed directly across the
sense resistor in series with the DC/DC converter’s inductor. Note that the current sense inputs must be limited to
less than 6V with respect to ground. Select RCM and CCM
such that the filter’s corner frequency is < 1/10 the DC/DC
converter’s switching frequency. This will result in a current
sense waveform that offers a good compromise between
the voltage ripple and the delay through the filter. A value
1kΩ for RCM is suggested in order to minimize gain errors due to the current sense inputs’ internal resistance.
Measuring Current with Inductor DCR
Figure 26 shows the circuit for applications that require
DCR current sense. A second order RC filter is required
in these applications in order to minimize the ripple voltage seen at the current sense inputs. A value of 1kΩ
is suggested for RCM1 and RCM2 in order to minimize
gain errors due the current sense inputs’ internal resistance. CCM1 should be selected to provide cancellation
RCM
(11)
CCM
Note: Not all DC/DC’s converters follow these trim equations especially newer bricks. Consult LTC Field Application
Engineering.
RCM
L
RSNS
CCM
VSENSEP1
LTC2977
VSENSEM1
2977 F25
LOAD CURRENT
Figure 25. Sense Resistor Current Sensing Circuits
2977f
84
For more information www.linear.com/LTC2977
LTC2977
APPLICATIONS INFORMATION
RCM2
CCM1
CCM1
RCM2
Let CCM2 = 3.3nF. Note that since CCM2 is much less than
CCM1 the loading effects of the second stage filter on the
matched first stage are not significant. Consequently, the
delay time constant through the filter for the current sense
waveform will be approximately 3μs.
VSENSEP1
CCM2
LTC2977
CCM2
VSENSEM1
2977 F26
RCM1
SWX0
RCM1
L
DCR
Measuring Multiphase Currents
Figure 26. Inductor DCR Current Sensing Circuits
For current sense applications with more than one phase,
RC averaging may be employed. Figure 27 shows an
example of this approach for a 3-phase system with DCR
current sensing. The current sense waveforms are averaged
together prior to being applied to the second stage of the
filter consisting of RCM2 and CCM2. Because the RCM1
resistors for the three phases are in parallel, the value of
RCM1 must be multiplied by the number of phases. Also
note that since the DCRs are effectively in parallel, the
value for IOUT_CAL_GAIN will be equal to the inductor’s
DCR divided by the number of phases. Care should to be
taken in the layout of the multiphase inductors to keep the
PCB trace resistance from the DC side of each inductor to
the summing node balanced in order to provide the most
accurate results.
of the zero created by the DCR and inductance, i.e.
CCM1 = L/(DCR • RCM1). CCM2 should be selected to
provide a second stage corner frequency at < 1/10 of the
DC/DC converter’s switching frequency. In addition, CCM2
needs to be much smaller than CCM1 in order to prevent
significant loading of the filter’s first stage.
Single Phase Design Example
As a design example for a DCR current sense application,
assume L = 2.2μH, DCR = 10mΩ, and FSW = 500kHz.
Let RCM1 = 1kΩ and solve for CCM1:
CCM1 ≥
2.2µH
= 220nF
10mΩ • 1kΩ
Multiphase Design Example
Let RCM2 = 1kΩ. In order to get a second pole at
FSW/10 = 50kHz:
CCM2 ≅
Using the same values for inductance and DCR from
the previous design example, the value for RCM1 will be
3kΩ for a three phase DC/DC converter if CCM1 is left at
220nF. Similarly, the value for IOUT_CAL_GAIN will be
DCR/3 = 3.33mΩ.
1
= 3.18nF
2π • 50kHz • 1kΩ
SWX1
RCM1
RCM1
RCM1
L
RCM2
CCM1
CCM2
VSENSEP1
LTC2977
DCR
VSENSEM1
RCM1/3
DCR
DCR
L
SWX2
TO LOAD
2977 F27
RCM2
CCM1
CCM2
L
SWX3
Figure 27. Multiphase DCR Current Sensing Circuits
2977f
For more information www.linear.com/LTC2977
85
LTC2977
APPLICATIONS INFORMATION
Anti-aliasing Filter Considerations
Noisy environments require an anti-aliasing filter on the
input to the LTC2977’s ADC. The R-C circuit shown in
Figure 28 is adequate for most situations. Keep R40 = R50
≤ 200Ω to minimize ADC gain errors, and select a value
for capacitors C10 and C20 that does not add too much
additional response time to the OV/UV supervisor, e.g. τ
≅ 10µs (R = 100Ω, C = 0.10µF).
while the VSENSEP1 input is tied to the REFP pin which
has a typical output voltage of 1.23V. The voltage divider
should be configured in order to present about 0.5V to the
voltage sense inputs when the negative supply reaches its
POWER_GOOD_ON threshold so that the current flowing
out of the VSENSEMn pin is minimized to ~1µA. The
relationship between the POWER_GOOD_ON register
value and the corresponding negative supply value can
be expressed as:
Sensing Negative Voltages
 R2 
VEE = VREFP – (READ_VOUT) •  + 1 – 1µA • R2
 R1 
Figure 29 shows the LTC2977 sensing a negative power
supply (VEE). The R1/R2 resistor divider translates the
negative supply voltage to the LTC2977s VSENSEM1 input
Where READ_VOUT returns VSENSEP – VSENSEM
VIN
4.5V < VIBUS < 15V
0.1µF 0.1µF
VIN
VPWR
VIN_SNS
VOUT
VDACP0
VDD33
VSENSEP0
VDD33
LTC2977*
VDD25
VSENSEM0
0.1µF
C10
R40
C20
R50
R30
R20
VFB
LOAD
R10
VDACM0
SGND
VOUT_EN0
GND
DC/DC
CONVERTER
*SOME DETAILS OMITTED FOR CLARITY
ONLY ONE OF EIGHT CHANNELS SHOWN
RUN/SS
GND
2977 F28
Figure 28. Antialiasing Filter on VSENSE Lines
4.5V < VIBUS < 15V
VIN_SNS
VPWR
LTC2977
REFP
1.23V TYP
0.1µF
SDA
PMBus
INTERFACE
SCL
ALERTB
CONTROL
REFM
VSENSEP1
1µA AT 0.5V
0.1µF
R1 = 4.99k
VSENSEM1
R2 = 120k
WDI/RESETB
VEE = –12V
FAULTB
SHARE_CLK
ASEL0
PWRGD
ASEL1
WP GND
WDI/RESETB
USE POWER_GOOD_ON = 0.5V FOR VEE POWER_GOOD = –11.414V
ONLY ONE OF EIGHT CHANNELS SHOWN,
SOME DETAILS OMITTED FOR CLARITY
2977 F29
Figure 29. Sensing Negative Voltages
2977f
86
For more information www.linear.com/LTC2977
LTC2977
APPLICATIONS INFORMATION
Connecting the DC1613 USB to I2C/SMBus/PMBus
Controller to the LTC2977 in System
Figures 30 and 31 illustrate application schematics for
powering, programming and communicating with one
or more LTC2977’s via the DC1613 I2C/SMBus/PMBus
controller regardless of whether or not system power is
present.
The DC1613 USB to I2C/SMBus/PMBus Controller can be
interfaced to LTC2977s on the user’s board for programming, telemetry and system debug. The controller, when
used in conjunction with LTpowerPlay software, provides
a powerful way to debug an entire power system. Failures
are quickly diagnosed using telemetry, fault status registers
and the fault log. The final configuration can be quickly
developed and stored to the LTC2977’s EEPROM.
Figure 30 shows the recommended schematic to use when
the LTC2977 is powered by the system intermediate bus
through its VPWR pin.
REPEAT OUTLINED CIRCUIT FOR EVERY LTC2977
150k
4.5V TO 15V
49.9k
VPWR
0.1µF
ISOLATED 3.3V
SCL
LTC2977*
VDD33
Si1303
VDD33
GND
0.1µF
SDA
VDD25
0.1µF
TO DC1613
I2C/SMBUS/PMBUS
CONTROLLER
10k
10k
5.49k
SCL
SDA
SHARE_CLK
TO/FROM OTHER
LTC2977s
WP
GND
2977 F30
*PIN CONNECTIONS OMITTED FOR CLARITY
Figure 30. DC1613 Controller Connections When VPWR Is Used
2977f
For more information www.linear.com/LTC2977
87
LTC2977
APPLICATIONS INFORMATION
Figure 31 shows the recommended schematic to use when
the LTC2977 is powered by the system 3.3V through its
VDD33 and VPWR pins. The LTC4412 ideal OR’ing circuit
allows either the controller or system to power the LTC2977.
n
Output Enables
Because of the controller’s limited current sourcing capability, only the LTC2977s, their associated pull up resistors
and the I2C/SMBus pull-up resistors should be powered
from the ORed 3.3V supply. In addition, any device sharing
I2C/SMBus bus connections with the LTC2977 should not
have body diodes between the SDA/SCL pins and its VDD
node because this will interfere with bus communication
in the absence of system power.
n
n
n
n
n
n
I2C
n
The address select pins (ASELn) are tri-level; See Table 1.
TP0101K-SSOT23
SYSTEM
3.3V
LTC4412
VIN
Verify that the absolute maximum ratings of the VOUT_ENn
pins are not violated.
No external resistive divider is required to sense VIN;
VIN_SNS already has an internal calibrated divider.
Logic Signals
Design Checklist
The LTC2977 must be configured for a unique address.
Use appropriate pull-up resistors on all VOUT_ENn pins.
VIN Sense
The DC1613 controller’s I2C/SMBus connections are
opto-isolated from the PC’s USB port. The 3.3V supply
from the controller and the LTC2977’s VDD33 pin can be
paralleled because the LTC LDOs that generate these voltages can be backdriven and draw <10μA. The controller’s
3.3V current limit is 100mA.
n
Check addresses for collision with other devices on the
bus and any global addresses.
Verify the absolute maximum ratings of the digital
pins (SCL, SDA, ALERTB, FAULTBzn, CONTROLn,
SHARE_CLK, WDI, ASELn, PWRGD) are not violated.
Short all SHARE_CLK pins in the system together and
pull up to 3.3V with a 5.49k resistor.
Do not leave CONTROLn pins floating. Pull up to 3.3V
with a 10k resistor.
Floating Inputs
n
Connect all unused VSENSEPn, VSENSEMn and DACMn
pins to GND.
IDEAL
DIODE
0R’d 3.3V
10k
10k
LTC2977_3.3V
5.49k
VDD33
0.1µF
VDD33
SENSE
GND
GATE
CTL
STAT
VPWR
0.1µF
VDD25
LTC2977*
ISOLATED 3.3V
SCL
SCL
GND
SDA
SHARE_CLK
SDA
WP
TO DC1613
I2C/SMBUS/PMBUS
CONTROLLER
GND
2977 F31
TO/FROM OTHER
LTC2977s
*PIN CONNECTIONS OMITTED FOR CLARITY
2C CONNECTIONS ARE OPTO-ISOLATED
NOTE: DC1613 CONTROLLER I
ISOLATED 3.3V FROM CONTROLLER CAN BE BACK DRIVEN AND WILL ONLY DRAW < 10µA
ISOLATED 3.3V CURRENT LIMIT = 100mA
Figure 31. DC1613 Controller Connections When LTC2977 Powered Directly from 3.3V
2977f
88
For more information www.linear.com/LTC2977
LTC2977
APPLICATIONS INFORMATION
LTpowerPlay: An Interactive GUI for Power
System Managers
LTpowerPlay is a powerful Windows based development environment that supports Linear Technology
Power System Manager ICs with EEPROM, including the
LTC2977 8-channel PMBus Power System Manager. The
software supports a variety of different tasks. You can
use LTpowerPlay to evaluate Linear Technology ICs by
connecting to a demo board system. LTpowerPlay can
also be used in an offline mode (with no hardware present) in order to build a multi-chip configuration file that
can be saved and reloaded at a later time. LTpowerPlay
provides unprecedented diagnostic and debug features. It
becomes a valuable diagnostic tool during board bring-up
to program or tweak the power management scheme in
a system or to diagnose power issues when bringing up
rails. LTpowerPlay utilizes Linear Technology’s DC1613
USB-to-I2C/SMBus/PMBus Controller to communicate
with one of many potential targets, including the DC2028
demo board set, the DC1508 socketed programming board,
or a customer target system. The software also provides
an automatic update feature to keep the software current
with the latest set of device drivers and documentation.
A great deal of context sensitive help is available within
LTpowerPlay along with several tutorial demos. Complete
information is available at:
www.linear.com/ltpowerplay
2977f
For more information www.linear.com/LTC2977
89
LTC2977
APPLICATIONS INFORMATION
PCB Assembly and Layout Suggestions
The proposed stencil design enables out-gassing of the
solder paste during reflow as well as regulating the finished
solder thickness. See IPC7525A.
Bypass Capacitor Placement
The LTC2977 requires 0.1µF bypass capacitors between
the VDD33 pins and GND, the VDD25 pin and GND, and the
REFP pin and REFM pin. If the chip is being powered from
the VPWR input, then that pin should also be bypassed
to GND by a 0.1µF capacitor. In order to be effective,
these capacitors should be made of high quality ceramic
dielectric such as X5R or X7R and be placed as close to
the chip as possible.
Exposed Pad Stencil Design
The LTC2977’s package is thermally and electrically
efficient. This is enabled by the exposed die attach pad
on the under side of the package which must be soldered
down to the PCB or mother board substrate. It is a good
practice to minimize the presence of voids within the
exposed pad inter-connection. Total elimination of voids
is difficult, but the design of the exposed pad stencil is
key. Figure 32 shows a suggested screen print pattern.
PC Board Layout
Mechanical stress on a PC board and soldering-induced
stress can cause the LTC2977’s reference voltage and
voltage drift to shift. A simple way to reduce these stressrelated shifts is to mount the IC near the short edge of the
PC board, or in a corner. The board edge acts as a stress
boundary, or a region where the flexure of the board is
minimal.
Unused ADC Sense Inputs
Connect all unused ADC sense inputs (VSENSEPn or
VSENSEMn) to GND. In a system where the inputs are
connected to removable cards and may be left floating
in certain situations, connect the inputs to GND using
100k resistors. Place the 100k resistors before any filter
components, as shown in Figure 33, to prevent loading
of the filter.
VSENSEP
QFN PACKAGE
100k
APERATURE DESIGN 50% TO 80% REDUCTION
GROUND PLANE
LTC2977
VSENSEM
100k
2977 F33
Figure 33. Connecting Unused Inputs to GND
2977 F32
Figure 32. Suggested Screen Pattern for Die Attach Pad
2977f
90
For more information www.linear.com/LTC2977
LTC2977
Package Description
Please refer to http://www.linear.com/designtools/packaging/ for the most recent package drawings.
UP Package
64-Lead Plastic QFN (9mm × 9mm)
(Reference LTC DWG # 05-08-1705 Rev C)
0.70 ±0.05
7.15 ±0.05
7.50 REF
8.10 ±0.05 9.50 ±0.05
(4 SIDES)
7.15 ±0.05
PACKAGE OUTLINE
0.25 ±0.05
0.50 BSC
RECOMMENDED SOLDER PAD PITCH AND DIMENSIONS
APPLY SOLDER MASK TO AREAS THAT ARE NOT SOLDERED
9 .00 ±0.10
(4 SIDES)
0.75 ±0.05
R = 0.10
TYP
R = 0.115
TYP
63 64
0.40 ±0.10
PIN 1 TOP MARK
(SEE NOTE 5)
1
2
PIN 1
CHAMFER
C = 0.35
7.50 REF
(4-SIDES)
7.15 ±0.10
7.15 ±0.10
(UP64) QFN 0406 REV C
0.200 REF
0.00 – 0.05
NOTE:
1. DRAWING CONFORMS TO JEDEC PACKAGE OUTLINE MO-220 VARIATION WNJR-5
2. ALL DIMENSIONS ARE IN MILLIMETERS
3. DIMENSIONS OF EXPOSED PAD ON BOTTOM OF PACKAGE DO NOT INCLUDE
MOLD FLASH. MOLD FLASH, IF PRESENT, SHALL NOT EXCEED 0.20mm ON ANY SIDE, IF PRESENT
4. EXPOSED PAD SHALL BE SOLDER PLATED
5. SHADED AREA IS ONLY A REFERENCE FOR PIN 1 LOCATION ON THE TOP AND BOTTOM OF PACKAGE
6. DRAWING NOT TO SCALE
0.25 ±0.05
0.50 BSC
BOTTOM VIEW—EXPOSED PAD
2977f
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection
of its circuits
as described
herein will not infringe on existing patent rights.
For more
information
www.linear.com/LTC2977
91
LTC2977
Typical Application
0.1µF
41
5
VOUT
44
46
R32
R22
DC/DC
CONVERTER
VFB
LOAD
R12
RUN/SS SGND
GND
47
45
6
50
48
49
51
IN
7
ASEL0
VIN_SNS
VPWR
ASEL1
VDD33
WP
GND
REFP
VDD25
VSENSEP7
VSENSEM7
VDACM0
VDACM7
VOUT_EN0
VOUT_EN7
VDACP1
VDACP6
VSENSEP1
VSENSEP6
VSENSEM1
VSENSEM6
VDACM1
VDACM6
VOUT_EN1
VOUT_EN6
LTC2977
VDACP2
VDACP5
VSENSEP2
VSENSEP5
VSENSEM2
VSENSEM5
VDACM2
VDACM5
VOUT_EN2
VOUT_EN5
VDACP3
VDACP4
VSENSEP3
VSENSEP4
VSENSEM3
VSENSEM4
VDACM3
OUT
INTERMEDIATE
BUS
CONVERTER
VDACP7
VSENSEM0
VOUT_EN3
VIN_EN
VIN
14
12
EN
3.3V
23
24
25
26
21
27
28
29
30
31
20
VDACM4
WDI/RESETB
43
32
PWRGD
42
33
CONTROL1
40
15
CONTROL0
4
16
ALERTB
RUN/SS SGND
GND
17
SCL
38
18
SDA
37
19
SHARE_CLK
LOAD
R10
65
FAULTB11
VFB
VSENSEP0
34
FAULTB10
DC/DC
CONVERTER
VDACP0
REFM
36
R30
R20
35
FAULTB01
39
FAULTB00
VOUT
DNC
13
VIN
3.3V
0.1µF
VDD33
0.1µF
VOUT_EN4
VOUT
60
2
3
R37
R27
VIN
DC/DC
CONVERTER
VFB
LOAD
R17
61
SGND RUN/SS
GND
11
VOUT
59
64
1
R36
R26
VIN
DC/DC
CONVERTER
VFB
LOAD
R16
58
SGND RUN/SS
GND
10
VOUT
56
62
63
R35
R25
VIN
DC/DC
CONVERTER
VFB
LOAD
R15
57
SGND RUN/SS
GND
9
VOUT
55
52
53
54
R34
R24
VIN
DC/DC
CONVERTER
VFB
LOAD
R14
SGND RUN/SS
GND
8
2977 F34
22
10k
10k
10k
10k
10k
10k
10k
10k
5.49k
10k
10k
10k
3.3V
TO/FROM OTHER LTC2974s, LTC2977s AND MICROCONTROLLER
Figure 34. LTC2977 Application Circuit with 3.3V Chip Power
Related Parts
PART NUMBER DESCRIPTION
COMMENTS
LTC2970
Dual I2C Power Supply Monitor and Margining Controller
5V to 15V, 0.5% TUE 14-Bit ADC, 8-Bit DAC, Temperature Sensor
LTC2974
4-Channel PMBus Power System Manager
0.25% TUE 16-Bit ADC, Voltage/Current/Temperature Monitoring and Supervision
LTC3880
Dual Output PolyPhase Step-Down DC/DC Controller
0.5% TUE 16-Bit ADC, Voltage/Current/Temperature Monitoring and Supervision
LTC3883
Single Output PolyPhase Step-Down DC/DC Controller
0.5% TUE 16-Bit ADC, Voltage/Current/Temperature Monitoring and Supervision
2977f
92 Linear Technology Corporation
1630 McCarthy Blvd., Milpitas, CA 95035-7417
For more information www.linear.com/LTC2977
(408) 432-1900 ● FAX: (408) 434-0507
●
www.linear.com/LTC2977
LT 0413 • PRINTED IN USA