XP Power JCB0312S09 Dc-dc power supply Datasheet

DC-DC
3 Watts
xppower.com
JCB Series
•
2:1 Input Range
•
Operating Temperature -40 ºC to +100 ºC
•
Single & Dual Outputs
•
1500 VDC Isolation
•
Optional Isolation to 3000 VDC
•
Optional Metal Case
•
3 Year Warranty
Specification
Input
General
Input Voltage Range
• 5 V (4.5-9 VDC)
12 V (9-18 VDC)
24 V (18-36 VDC)
48 V (36-75 VDC)
Input Current
• See table
Input Filter
• LC network
Input Reflected Ripple • 35 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
Input Surge
• 5 V models 15 VDC for 100 ms
12 V models 24 VDC for 100 ms
24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
Output
Output Voltage
Minimum Load
Intial Set Accuracy
Start Up Delay
Start Up Rise Time
Line Regulation
Load Regulation
Cross Regulation
Transient Response
•
•
•
•
•
•
•
•
•
See table
Minimum load required, see note 1
±1% max
20 ms typical
10 ms typical
±0.5% max
±0.5% max
±5% on dual output models, see note 2
<3% deviation, recovery to within 1% in
2 ms for a 50% load change
Ripple & Noise
• 60 mV pk-pk, 20 MHz BW
Short Circuit Protection • Continuous with auto recovery
Maximum Capacitive
• See tables
Load
Temperature
• ±0.02/°C max
Coefficient
Efficiency
Isolation
Isolation Capacitance
Switching Frequency
MTBF
• See tables
• 1500 VDC Input to Output
For optional high isolation version 3000 VDC,
see note 3
1500 VDC Input to Case
1500 VDC Output to Case
• 60 pF max
• 100-400 kHz variable
• >2 MHrs to MIL-STD-217F
Environmental
Operating Temperature • -40 ºC to +100 ºC, derate from 100% load
at +80 °C to no load at +100 °C
Case Temperature
• +100 ºC max
Storage Temperature
• -40 ºC to +125 ºC
Humidity
• Up to 90%, non-condensing
Cooling
• Natural convection
Input
Voltage
Output
Voltage
4.5-9 V
5.0
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
Output
Current
V
V
V
V
V
V
V
V
V
V
600
333
250
200
125
±300
±167
±125
±100
±63
5.0 V
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
9-18 V
600 mA
V
V
V
V
V
V
V
V
V
333
250
200
125
±300
±167
±125
±100
±63
5.0 V
18-36 V
36-72 V
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
600 mA
Input Current(6)
No Load
Full Load
40
40
40
40
40
40
40
40
40
40
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
857
833
810
810
857
869
857
833
810
857
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
20 mA
328 mA
20
20
20
20
20
20
20
20
20
324
316
316
316
324
320
320
320
320
mA
mA
mA
mA
mA
mA
mA
mA
mA
Efficiency
Model (3,4,5)
Number
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
70%
72%
74%
74%
70%
69%
70%
72%
74%
70%
JCB0305S05
JCB0305S09
JCB0305S12
JCB0305S15
JCB0305S24
JCB0305D05
JCB0305D09
JCB0305D12
JCB0305D15
JCB0305D24
2200 µF
Maximum
Capacitive Load
2200
470
470
470
220
±1000
±220
±220
±220
±100
mA
mA
mA
mA
mA
mA
mA
mA
mA
76%
JCB0312S05
µF
µF
µF
µF
µF
µF
µF
µF
µF
77%
79%
79%
79%
77%
78%
78%
78%
78%
JCB0312S09
JCB0312S12
JCB0312S15
JCB0312S24
JCB0312D05
JCB0312D09
JCB0312D12
JCB0312D15
JCB0312D24
2200 µF
470
470
470
220
±1000
±220
±220
±220
±100
12 mA
156 mA
80%
JCB0324S05
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
V
V
V
V
V
V
V
V
V
333
250
200
125
±300
±167
±125
±100
±63
mA
mA
mA
mA
mA
mA
mA
mA
mA
12
12
12
12
12
12
12
12
12
mA
mA
mA
mA
mA
mA
mA
mA
mA
156
152
152
156
160
158
156
156
156
mA
mA
mA
mA
mA
mA
mA
mA
mA
470
470
470
220
±1000
±220
±220
±220
±100
µF
µF
µF
µF
µF
µF
µF
µF
µF
80%
82%
82%
80%
78%
79%
80%
80%
80%
JCB0324S09
JCB0324S12
JCB0324S15
JCB0324S24
JCB0324D05
JCB0324D09
JCB0324D12
JCB0324D15
JCB0324D24
5.0
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
V
V
V
V
V
V
V
V
V
V
600
333
250
200
125
±300
±167
±125
±100
±63
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
8
8
8
8
8
8
8
8
8
8
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
81
80
78
78
78
80
79
78
78
78
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
2200
470
470
470
220
±1000
±220
±220
±220
±100
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
77%
78%
80%
80%
80%
78%
79%
80%
80%
80%
JCB0348S05
JCB0348S09
JCB0348S12
JCB0348S15
JCB0348S24
JCB0348D05
JCB0348D09
JCB0348D12
JCB0348D15
JCB0348D24
Notes
1. Minimum load required to meet noise and ripple and initial set accuracy
specificaitons. Below 25% load, noise and ripple increases to 200 mV pk-pk
typical and load regulation to ±1% max.
2. Cross regulation is ±5% when one output is at 100% the other is varied
between 25% and 100%.
3. For optional 3000 VDC isolation, add suffix ‘-H’ to end of part number.
4. For optional metal case version, add suffix ‘-M’ to end of part number,
eg. JCB0324S12-HM
5. For alternative pin out, add suffix ‘-Z’ to end of part number,
eg. JCB0324S12-HMZ
6. Input current measured at nominal input voltage
Mechanical Details
PIN CONNECTIONS
0.01
(0.25)
0.90
(22.86)
1
2
1.25 (31.75)
3
9
10 11 12
Bottom View
24 23 22
0.02
(0.50)
15.24
(0.60)
0.80
(20.32)
16 15 14 13
0.20
(5.08)
All dimensions are in inches (mm)
Weight: 0.04 lbs (20 g) approx.
Pin diameter: 0.5±0.05 (0.02±0.002)
Pin pitch tolerance: ±0.35 (±0.014)
Case tolerance: ±0.5 (±0.02)
0.40
(10.16)
0.12 (3.05) Min.
Pin
Single
Dual
Single-H
Dual-H
Single-Z,
or -HZ
Dual-Z,
or -HZ
1
2
3
9
10
11
12
13
14
15
16
22
23
24
+Vin
N.C.
N.C.
N.P.
-Vout
+Vout
-Vin
-Vin
+Vout
-Vout
N.P.
N.C.
N.C.
+Vin
+Vin
-Vout
Common
N.P.
Common
+Vout
-Vin
-Vin
+Vout
Common
N.P.
Common
-Vout
+Vin
N.P.
-Vin
-Vin
N.C.
N.P.
N.C.
N.P.
N.P.
+Vout
N.P.
-Vout
+Vin
+Vin
N.P.
N.P.
-Vin
-Vin
Common
N.P.
-Vout
N.P.
N.P.
+Vout
N.P.
Common
+Vin
+Vin
N.P.
N.P.
-Vin
-Vin
N.P.
N.P.
N.C.
N.P.
N.P.
+Vout
N.P.
-Vout
+Vin
+Vin
N.P.
N.P.
-Vin
-Vin
Common
N.P.
-Vout
N.P.
N.P.
+Vout
N.P.
Common
+Vout
+Vout
N.P.
N.C. - No Connection
N.P. - No Pin
20-Feb-09
DC-DC
JCB Series
Models and Ratings
Similar pages