Rectron HER201 High efficiency rectifier voltage range 50 to 1000 volts current 2.0 ampere Datasheet

HER201
THRU
HER208
HIGH EFFICIENCY RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 2.0 Amperes
FEATURES
*
*
*
*
*
*
*
Low power loss,high efficiency
Low leakage
Low forward voltage drop
High current capability
High speed switching
High reliability
High current surge
DO-15
MECHANICAL DATA
*
*
*
*
*
Epoxy: Device has UL flammability classification 94V-O
Case: Molded plastic
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.4 gram
.034 (0.9)
1.0 (25.4)
.028 (0.7)
DIA.
MIN.
.300 (7.6)
.230 (5.8)
.140 (3.6)
.104 (2.6)
DIA.
1.0 (25.4)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
MIN.
Ratings at 25 o C ambient temperature unless otherwise specified.
resistive or inductive load.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
HER201
HER202
HER206
HER207
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
300
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
210
280
420
560
700
Volts
VDC
50
100
200
300
400
600
800
1000
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T A = 50 OC
HER203
HER204
HER205
HER208 UNITS
IO
2.0
Amps
I FSM
60
Amps
2
I T
14.9
Typical Thermal Resistance (Note 1)
RqJL
10
0
Typical Thermal Resistance (Note 1)
RqJC
15
0
Typical Thermal Resistance (Note 1)
RqJA
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squared Time
A 2S
0
40
C/W
C/W
C/W
Typical Junction Capacitance (Note 2)
CJ
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Storage Temperature Range
30
20
pF
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Instantaneous Forward Voltage at 2.0A DC
Maximum Full Load Reverse Current, Full
cycle Average T L =55 OC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
Maximum Reverse Recovery Time (Note 4)
VF
HER201
HER202
HER203
1.0
HER204
HER205
1.3
HER206
HER207
1.7
mA
5
mA
mA
100
NOTES : 1. Thermal Resistance : At 9.5mm lead length,PCB mounted.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
4. Test Conditions: IF= 0.5A, IR= -1.0A, IRR= -0.25A.
5. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
50
Volts
100
IR
trr
HER208 UNITS
75
nSec
2011-03
REV:B
RATING AND CHARACTERISTICS CURVES ( HER201 THRU HER208 )
50 W
NONINDUCTIVE
(+)
25 Vdc
(approx)
(-)
(-)
D.U.T
PULSE
GENERATOR
(NOTE 2)
1
NONINDUCTIVE
trr
+0.5A
10 W
NONINDUCTIVE
OSCILLOSCOPE
(NOTE 1)
0
-0.25A
(+)
NOTES: 1 Rise Time = 7ns max. Input Impedance =
1 megohm. 22pF.
-1.0A
2. Rise Time = 10ns max. Source Impedance =
50 ohms.
1cm
SET TIME BASE FOR 20/1 ns/cm
AVERAGE FORWARD CURRENT, (A)
2.0
1.6
1.2
0.8
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
0.4
0
0
25
50
75
100
125
150
AMBIENT TEMPERATURE, (OC)
FIG.2 TYPICAL FORWARD CURRENT
DERATING CURVE
175
INSTANTANEOUS REVERSE CURRENT, (uA)
FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
1000
100 TA = 100 OC
TA = 75 OC
10
TA = 25 OC
1.0
0.1
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE
CHARACTERISTICS
140
PEAK FORWARD SURGE CURRENT, (A)
20
10
TJ = 25 OC
3.0
HER206~HER208
1.0
0.3
HER204~HER205
0.1
HER201~HER203
0.03
0.01
Pulse Width=300uS
1% Duty Cycle
0
0.5
1.0
1.5
2.0
2.5
3.0
200
8.3ms Single Half Sine-Wave
(JEDED Method)
150
125
100
3.5
50
30
20
10
1
5
INSTANTANEOUS FORWARD VOLTAGE, (V)
10
TJ = 25 OC
100
HER201~HER205
40
20
10
HER206~HER208
6
4
2
1
0.1 0.2
100
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
200
60
50
NUMBER OF CYCLES AT 60Hz
FIG.4 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
JUNCTION CAPACITANCE, (pF)
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( HER201 THRU HER208 )
0.4
1.0
2
4
10
20
40
REVERSE VOLTAGE, (V)
FIG.6 TYPICAL JUNCTION CAPACITANCE
100
THE MARKING OF HER20X
Marking Description:
Cathode band
Logo
Part No.
V X X
HER20X
Month Code
Year Code
Marking Description
Cathode Band
Rectron Logo
Part No.
Year – code:
(Y:Last digit of year)
V Y M
H
E R 2
0
X
Month – code:
(M:0~9,O,N,D)
Voltage-code
1-------50V
2-------100V
3-------200V
4-------300V
5------400V
6-------600V
7-------800V
8-------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
DO-15
-B
EA PER BOX INNER BOX SIZE CARTON SIZE EA PER CARTON
(mm)
(mm)
500
194*84*21
450*220*255
25,000
GROSS
WEIGHT(Kg)
12.74
REEL PACK
PACKAGE
DO-15
PACKING EA PER
REEL
CODE
-T
4,000
COMPONENT TAPE SPACE
SPACE(mm)
(mm)
5.0
52
REEL DIA
(mm)
CARTON SIZE EA PER
GROSS
CARTON WEIGHT(Kg)
(mm)
330
355*350*335
16,000
10.05
BOX SIZE
(mm)
CARTON
SIZE(mm)
CARTON
( EA )
GROSS
WEIGHT (Kg)
255*73*100
400*268*225
15,000
8.8
AMMO PACK
PACKAGE
PACKING
CODE
REEL
( EA )
DO-15
-F
1,500
COMPONENT TAPE SPACE
SPACE(mm)
(mm)
5.0
52
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.