MPD MPA200LX-12Z Low profi le 200w single output power factor corrected ac/dc power supply Datasheet

MPA200L Series
Low Profile 200W
Single Output
Power Factor Corrected
AC/DC Power Supplies
Key Features:
• 200W Output Power
• Universal 90-264V AC Input
• PFC to EN61000-3-2 “D”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• 3.3, 5, 12, 24 & 48 V Outputs
• Peak Power to 600W
Only
6.8 x 3.8 x
1.5 in!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without
h
notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current (Note 1)
Power Factor Correction
Input Protection
Conditions
Universal
Min.
90
47
Typ.
Max.
264
63
100 VAC
4
110 VAC
35
240 VAC
1.5
Active, Meets EN61000-3-2 Class D
T5A/250V Fuse
Units
VAC
Hz
A
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation (Note 2)
Hold Time
Ripple & Noise (20 MHz) (Note 3)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 4)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
Max.
±5.0
±1.0
80% Load
20
See Model Selection Guide
Hiccup Mode, Auto Recovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
>+85ºC Ambient with Autorecovery
±0.04
500
50% Load Change
5
At Turn On/Off
5.0
120 VAC
1
Continuous With Autorecovery
By Trim Pot
Units
%
%
mSec
%
%/ºC
µS
%
%
S
General
Parameter
Isolation Voltage
Switching Frequency
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
23
kHz
Interface Signals
MicroPower Direct
Power Supply On
292 Page Street
Suite D
Stoughton, MA 02072
USA
Power Good Signal
Remote Sense
Remote On/Off
Green LED (LED1) on the PCB
PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
RS + and RS- on CN3. Compensates for up to a 0.5V line drop.
REMO on CN3. A TTL low signal inhibits the output
Environmental
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Conditions
Min.
Typ.
Max.
Ambient
0
+25
+50
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
See Model Selection Guide
RH, Non-condensing
90
Units
ºC
ºC
%
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
Model Selection Guide
Model
Number
MPA200Lx-03z
MPA200Lx-05z
MPA200Lx-12z
MPA200Lx-24z
MPA200Lx-48z
Output Voltage
Factory
Range (Note 5)
PreSet
3.3 VDC
3.0 - 4.0 VDC
5 VDC
5.0 - 6.0 VDC
12 VDC 12.0 - 18.0 VDC
24 VDC 24.0 - 36.0 VDC
48 VDC 36.0 - 56.0 VDC
Output Current (Notes 6, 7, 8)
With
(“U” units) Max.
Min
17 CFM
22.00A
0.0A
30.00A
22.00A
0.0A
40.00A
12.50A
0.0A
16.66A
6.25A
0.0A
8.33A
3.12A
0.0A
4.16A
Notes:
1. Models are available with leakage current specified as low as 750 µA.
Contact the factory for details.
2. Output regulation includes line & load.
3. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement
connection to the unit is made with a 0.1 µF ceramic capacitor & a 22
µF electrolytic capacitor connected in parallel.
4. Transient recovery is measured to within a 1% error band for a load
step change of 50% to 100%.
Ripple &
Noise
Efficiency
50 mV p-p
50 mV p-p
1% p-p
1% p-p
1% p-p
70%
75%
80%
83%
83%
Input Connector CN1:
U-Chassis (U,C)
Mating Molex Part No. 09-91-0500 (5 pin, 3 used)
or Howder Terminal Block No. FTB-702-3P (3-pin)
or equivalent.
Output Connector CN2:
Mating Molex Part No. 09-91-1200 (12 pin) or Howder
Terminal Block No. HD-301-4P (4-pin) or equivalent.
Output Pin Assignment:
(Note 7)
5. The full output range (see table above) is covered in the safety agency certification.
Standard models are factory set to the “Preset” voltage. This may be set to other levels
within the range without affecting the agency certification. Contact the factory for
details.
6. A minimum 1% load is required to maintain load regulation and ripple specifications.
7. Output current is given for the factory preset voltage. For more information, contact the
factory.
8. Units will provide peak power of 600W for 500 µS. For units capable of longer durations, contact the factory.
Mechanical Dimensions: U-Chassis (U Suffix)
Howder
Molex
Pins 1 ~ 2: V+
Pins 1 ~ 6: V+
Pins 3 ~ 4: V-
Pins 7 ~ 12: V-
Logic Signal Connector CN3:
Mating JST XHP-6 or equivalent (CHYAO SHIUNN
JS-2001-06).
Fan driver connector (FAN):
12 VDC / 500 mA is available to drive an external fan.
Mating JST XHP-2 or equivalent (CHYAO SHIUNN
JS-2001-02).
U-Chassis Cover (C Suffix)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]