Emerson Network Power LPS122 120 watts active power factor correction Datasheet

Embedded Power for
Business-Critical Continuity
Rev. 09.15.09_12
LPS120 Series
of 3
LPS120 Series
120 Watts
Total Power:
Input Voltage:
# of Outputs:
80 - 130 Watts
85 - 264 VAC
Single
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Active power factor correction
3” x 5” footprint
Less than 1U high
EN61000-3-2 compliant
Remote sense
Power fail and remote inhibit
Single wire current sharing
Adjustable main output
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Thermal overload protection
5 V Standby output
and 12V Fan output
Electrical Specifications
Input
Input ra­nge:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Power factor:
Safety ground
leakage current:
85 - 264 VAC ; 127 - 300VDC
47 - 440 Hz
40 A max., cold start @ 25 °C
80% typical at full load
FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted
0.99 typical
0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power:
Adjustment range:
Fan output:
Standby outputs:
80 W for convection ; 130 W with 30CFM forced air
± 5% minimum on the main outputs
12 V @ 500mA - 5%, +7%
5V @ 500mA ± 5%
Hold-up time:
20ms @ 125 W load, 120 VAC input
Overload protection:
Short circuit protection on all outputs. Case overload protected @
120 - 135% above rating
Overvoltage protection: 20 - 35% above nominal output
Remote sense:
Compensates for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Logical Control
Power failure:
Safety
TUV:
UL:
CSA
NEMKO:
AUSTEL:
CB:
CE:
60950
60950
60950
60950
60950
Certificate and report
Mark (LVD)
Remote inhibit:
Remote sense:
TL logic signal goes high 100 - 500 msec after main output; it goes low at
T
least 4 msec before loss of regulation
Requires a contact closure to disable the outputs, except 5 V standby.
ompensates for 0.5 V lead drop min. Will operate without remote sense
C
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 09.15.09_128
LPS120 Series
of 3
Environmental Specifications
Operating temperature:
SK1
0.15" DIA. 4 places
(4.0)
NEUTRAL
MTBF demonstrated
Operating; non-condensing
10% to 95% RH
IEC68-2-6 to the levels of
IEC721-3-2
> 550,000 hours at full load and
25 °C ambient conditions
LIVE
Vibration:
3.00
(76.2)
2.55
(64.8)
EARTH
Humidity:
-40 °C to +85 °C
Designed to meet EN61000-4;
-2, -3, -4, -5, -6, -8, -11 Level 3
P1
Storage temperature:
Electromagnetic
susceptibility:
0° to 50 °C ambient derate each
Mechanical Drawing
output as 2.5% per degree from
50° to 70 °C. -20 °C start up
5.00
(127.0)
4.55
(115.6)
1
2
SK3
M3.5 (2 places)
SK2
V
Adjust
POT
1.29
(32.8)
5
1
6
10
SK3
0.20" (5)
Embedded Power for
Business-Critical Continuity
­Americas
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load
with Convection
Cooling
Maximum Load
with 30CFM
Peak Load Regulation2
Forced Air
Ripple
P/P
(PARD)3
LPS121
3.3 V
0A
21 A
36 A
29 A
± 2%
50 mV
LPS122
5V
0A
16 A
26 A
29 A
± 2%
50 mV
LPS123
12 V
0A
6.7 A
10.8 A
12.8 A
± 2%
120 mV
LPS124
15 V
0A
5.3 A
8.7 A
10.0 A
± 2%
150 mV
LPS125
24 V
0A
3.4 A
5.4 A
6.3 A
± 2%
240 mV
LPS128
48 V
0A
1.7A
2.7 A
3.2 A
± 2%
480 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3­. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4­. When in parallel a 10% load is required for each power supply.
Pin Assignments
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 09.15.09_12
LPS120 Series
of 3
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
Connector
LPS120
SK1
Pin1
Pin3
Neutral
Line
For global contact, visit:
SK2
TB-1
TB-2
COMMON
Main output
techsupport.embeddedpower
@emerson.com
SK3
Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8
Pin9
Pin10
+V1 Remote sense
-V1 Remote sense
+Remote inhibit
-Remote inhibit
+Power fail
Common
SWP
+12V
12V common
+5V standby
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
www.PowerConversion.com
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Mating Connectors
(SK1)AC Input:
Molex 09-50-8031 (connector) 08-52-0113 (pins)
Connectivity
(SK2)DC Output:
Molex series 19141-0058/0063 Spade lug
DC Power
Embedded Computing
(SK3) Control Signals:
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Emerson Network Power Connector Kit # 70-841-020, includes all of the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± .02”.
3. mounting holes MH1, MH2, MH3 should be grounded for
EMI purpose
4. Mounting MH1 is safety ground connection
5. Specifications are for convection rating at factory settings
at 115 VAC input 25 °C unless otherwise stated.
6. This power supply requires mounting on metal standoffs
0.20” (5m) in height.
7. Warranty: 2 year
8. Weight: 0.71 lb. / 0.32 kg
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2009 Emerson Electric Co.
Similar pages