A300RW Series Wide Input Range, 3W Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 3W Output Power • UL Approved (File E245422) • 2:1 Input Voltage Range • 1,500 VDC Isolation • Compact DIP Case • Single & Dual Outputs • 28 Standard Models • 1.0 MH MTBF • Industry Standard Pin-Out RoHS Compliant MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Input Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions Min. 5 VDC Input 3.5 12 VDC Input 4.5 24 VDC Input 8.0 48 VDC Input 16.0 π (Pi) Filter Typ. 4.0 7.0 12.0 24.0 Max. 4.5 9.0 18.0 36.0 Units 1,000 1.0 2,000 A mW Typ. ±0.5 ±0.5 ±0.2 ±0.2 45 Max. ±1.0 ±2.0 ±0.5 ±0.5 60 100 15 300 ±3.0 ±0.01 Continuous (Autorecover) 500 ±5.0 ±0.02 Units % % % % mV P - P mV P - P mV rms % µSec % %/ºC Conditions Min. Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% Over Line, Load & Temp. 120 50% Load Step Change Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,500 1,000 Typ. Max. 65 300 100 Conditions Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing Ambient Case VDC Units VDC MΩ pF kHz Max. +71 +90 +125 Units ºC ºC ºC 95 % 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Non-Conductive Black Plastic (UL-94V0) 0.42 Oz (12g) Conditions Min. Typ. MIL HDBK 217F, 25ºC, Gnd Benign 1.0 UL 1950, EN 60950, IEC 60950 UL, cUL; File No. E245422 Conditions 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. Units MHours Max. 11.0 25.0 50.0 100.0 260 2,500 Units VDC ºC mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Input Current (mA) Voltage (VDC) Model Number Nominal Range Full-Load 5 5 5 5 5 5 5 12 12 12 12 12 12 12 24 24 24 24 24 24 24 48 48 48 48 48 48 48 4.5 - 9.0 4.5 - 9.0 4.5 - 9.0 4.5 - 9.0 4.5 - 9.0 4.5 - 9.0 4.5 - 9.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 566 685 779 779 694 800 800 223 267 305 305 271 313 313 109 132 149 149 132 152 152 55 66 75 75 65 75 75 Output Reflected Efficiency Current Ripple Voltage Current (%, Typ) (VDC) (mA, Max) (mA, Min) No-Load Current Fuse Rating Slow-Blow (mA) (mA, Typ) A301RW A302RW A303RW A304RW A305RW A306RW A307RW A311RW A312RW A313RW A314RW A315RW A316RW A317RW A321RW A322RW A323RW A324RW A325RW A326RW A327RW A331RW A332RW A333RW A334RW A335RW A336RW A337RW 40 40 40 40 40 40 40 20 20 20 20 20 20 20 5 5 5 5 5 5 5 3 3 3 3 3 3 3 100 100 100 100 100 100 100 30 30 30 30 30 30 30 15 15 15 15 15 15 15 10 10 10 10 10 10 10 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 Notes: 1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 8.2 µF is recommended, for 12V input units, a 3.3 µF; and for 24V & 48V units a 2.2 µF. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. 600.0 500.0 250.0 200.0 ±250.0 ±125.0 ±100.0 600.0 500.0 250.0 200.0 ±250.0 ±125.0 ±100.0 600.0 500.0 250.0 200.0 ±250.0 ±125.0 ±100.0 600.0 500.0 250.0 200.0 ±250.0 ±125.0 ±100.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 70 73 77 77 72 75 75 74 78 82 82 77 80 80 76 79 84 84 79 82 82 76 79 84 84 80 84 84 1,500 1,500 1,500 1,500 1,500 1,500 1,500 700 700 700 700 700 700 700 350 350 350 350 350 350 350 135 135 135 135 135 135 135 Derating Curve Mechanical Dimensions Pin Connections Pin Single Dual Pin Single Dual 2, 3 9 11 -Vin No Pin NC -Vin Common -Vout 14 16 22, 23 +Vout -Vout +Vin +Vout Common +Vin NC: No Connection Capacitive Load Single Output Dual Output 4,000 µF Max ±1,000 µF Max Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Leads are gold plated for improved solderability. MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]