MORNSUN F2415XT-2WR2 Dc/dc converter Datasheet

DC/DC Converter
F_XT-2WR2 Series
2W, Fixed input voltage, isolated & unregulated single
output
FEATURES
z Efficiency up to 86%
z Isolation voltage: 3KVDC
z Operating temperature range: -40℃ to +105℃
z
z
z
z
Patent Protection RoHS
Miniature SMD package
Internal surface mounted design
No external component required
International standard pin-out
F_XT-2WR2 series is specially designed for applications where an isolated voltage is required in a distributed power supply system. It is
suitable for:
1.Where the voltage of the input power supply is stable (voltage variation: ±10%Vin);
2.Where isolation is necessary between input and output (isolation voltage ≤3000VDC);
3.Where do not has high requirement of line regulation , load regulation and the ripple & noise of the output voltage;
Such as: pure digital circuits, low frequency analog circuits, relay-driven circuits and data switching circuits.
Selection Guide
Input Voltage (VDC)
Part No.
Output
Nominal
Output Voltage
Output Current (mA)
(Range)
(VDC)
(Max./Min.)
Efficiency
(%,Min./Typ.)
Max. Capacitive
Load
@ Full Load
(μF)
F0503XT-2WR2
3.3
400/40
68/72
F0505XT-2WR2
5
400/40
75/79
F0509XT-2WR2
F0512XT-2WR2
5
(4.5-5.5)
F0515XT-2WR2
9
222/22
78/82
12
167/17
78/82
15
133/13
79/83
5
400/40
75/79
F1212XT-2WR2
F1205XT-2WR2
12
12
167/17
78/82
F1215XT-2WR2
(10.8-13.2)
15
133/13
79/83
F1224XT-2WR2
24
83/8
80/84
15
(13.5-16.5)
15
133/13
79/83
5
400/40
75/79
F2412XT-2WR2
24
12
167/17
78/82
F2415XT-2WR2
(21.6-26.4)
15
133/13
79/83
24
83/8
82/86
F1515XT-2WR2
F2405XT-2WR2
F2424XT-2WR2
220
Input Specifications
Item
Operating Conditions
5V input
Input Current (full load / no-load)
Surge Voltage (1sec. max.)
Surge Voltage (1sec. max.)
Reflected Ripple Current
Input Filter
Min.
Typ.
Max.
--
506/30
--
12V input
--
212/25
--
15V input
--
169/18
--
24V input
--
105/15
--
5V input
-0.7
--
9
12V input
-0.7
--
18
15V input
-0.7
--
21
24V input
-0.7
--
30
15
--
--
Unit
mA
VDC
VDC
mA
Capacitance Filter
2014.05.22-A/1
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
F_XT-2WR2 Series
Output Specifications
Item
Operating Conditions
Min.
Output Voltage Accuracy
Line Regulation
Input voltage change: ±1%
Load Regulation
10%-100% load
Temperature Drift Coefficient
Output Short Circuit Protection **
Max.
3.3VDC output
--
--
±1.5
Other output
--
--
±1.2
3.3VDC output
--
18
--
5VDC output
--
12
--
9VDC output
--
9
--
12VDC output
--
8
--
15VDC output
--
7
--
24VDC output
Ripple & Noise*
Typ.
Unit
See tolerance envelope graph (Fig. 1)
--
%
--
6
--
20MHz bandwidth
--
100
--
mVp-p
100% load
--
--
±0.03
%/℃
5/12/15VDC input
Continuous, self-recovery
24VDC input
--
--
1
s
Notes:
* Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
**For the products of 24V Intput voltage, supply voltage must be discontinued at the end of short circuit duration.
General Specifications
Item
Operating Conditions
Min.
Isolation Voltage
Input-output, with the test time of 1 minute and the leak
current lower than 1mA.
3000
Isolation Resistance
Input-output, isolationvoltage 500VDC.
1000
Isolation Capacitance
Input-output, 100KHz/0.1V.
--40
--
105
-55
--
125
Operating Temperature
Derating if the temperature ≥71°C,
(see Fig. 2)
Derating if the temperature ≥85°C,
(see Fig. 2)
3.3V/5V
output
Other output
Storage Temperature
Typ.
Max.
--
VDC
--
--
MΩ
20
--
pF
--
Casing Temperature Rise
Ta=25℃
--
25
--
Pin Welding Resistance Temperature
Welding spot is 1.5mm away from the casing, 10
d
--
--
300
Non-condensing
Switching Frequency
100% load, nominal input voltage.
MTBF
MIL-HDFK-217F@25℃
℃
Peak temp.≤245℃, maximum duration
time≤60s at 217℃.
For actual application, please refer to
IPC/JEDEC J-STD-020D.1.
Reflow Soldering Temperature
Storage Humidity
Unit
--
--
--
100
3500
--
95
300
--
%
KHz
K hours
Physical Specifications
Casing Material
Black flame-retardant heat-proof epoxy resin (UL94-V0)
Package Dimensions
12.70*11.20*7.25mm
Weight
1.5g (Typ.)
Cooling Method
Free air convection
EMC Specifications
EMI
EMS
Conducted disturbance
CISPR22/EN55022
CLASS B (see Fig. 4 for recommended circuit)
Radiated emission
CISPR22/EN55022
CLASS B (see Fig. 4 for recommended circuit)
Electrostatic discharge
IEC/EN61000-4-2
Contact ±6KV
perf. Criteria B
2014.05.22-A/1
Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
F_XT-2WR2 Series
Product Characteristic Curve
Tolerance Envelope Graph
Te mperat ure Derating Grap h
Ty p ic a
+5%
Rated
Output Voltage
l Lo ad
C u rv e
O utp ut Pow er Pe rce nt (%)
+10%
+2.5%
Output Voltage
Accuracy(%)
-2.5%
-7.5%
70
50
100
1 20
1 00
80
Output Current Percentage(%)
60
5 0 Sa fe Op e ra t ing Are a
40
20
0
- 40
40
7 1 8 5 1 05
0
Am bi ent Te mp .(℃ )
(Nominal Input Voltage)
Fig. 2
Fig. 1
Efficiency Vs Input Voltage (Full Load)
95
90
90
80
85
70
80
F0505XT-2WR2
75
70
65
Efficiency(%)
100
40
30
10
5.5
5.4
5.3
5.2
5
5.1
0
4.9
10
50
4.8
20
4.7
F0505XT-2WR2
50
55
4.6
Efficiency Vs Output Load(Vin=5V)
60
60
4.5
Efficiency(%)
100
20
Input Voltage(V)
Efficiency Vs Input Voltage (Full Load)
90
F1212XT-2WR2
75
70
65
60
55
60
70
80
90
100
100
90
80
70
60
50
40
30
20
10
0
F1212XT-2WR2
10
13.2
13.0
12.8
12.5
12.2
12.0
11.8
11.3
11.0
50
10.8
50
Efficiency(%)
Efficiency(%)
95
80
40
Efficiency Vs Output Load(Vin=12V)
100
85
30
Output Current Percentage(%)
20
30
40
50
60
70
80
90
100
Output Current Percentage(%)
Input Voltage(V)
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.3.
Moreover, choosing suitable filter capacitor is very important, start-up problems may be caused by too large capacitance. To ensured the
modules running well, the recommended capacitive load values as shown in Table 1.
Recommended capacitive load value table (Table 1)
+Vo
Vin
C in
DC
DC
GND
C out
0V
Fig.3
Vin(VDC)
Cin(μF)
Vo (VDC)
5
4.7
3.3
Cout(μF)
10
12
2.2
5
10
15
2.2
9
4.7
24
1
12
2.2
--
--
15
1
--
--
24
0.47
It is not recommended to connect any external capacitor when
output power is less than 0.5W.
2014.05.22-A/1
Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
F_XT-2WR2 Series
2. EMC typical recommended circuit
LDM
Vin
Vin
C1
GND
C2
+Vo
DC/DC
GND
C3
LOAD
0V
CY
Fig. 4
Input voltage (VDC)
C1
C2
EMI
C3
CY
LDM
5/12/15/24
4.7μF /50V
4.7μF /50V
Refer to the Cout in Fig.3
-6.8μH
Note: 1. F2424XT-2WR2 is subject to CY (CY : 470pF/3KV).
2. It is not needed to add the component in the peripheral circuit
when parameter with the symbol of "--".
3. Output load requirements
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If
the actual output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of
the rated power, and derating is required during operation.
4. For more information please find DC-DC converter application notes on www.mornsun-power.com
Dimensions and Recommended Layout
Notes:
1.
Packing information please refer to "Product Packing Information ".Packing bag number: 58210024;
2.
If the product is operated out of the min. load requirement, the product performance may not meet all parameter indexes in this
datasheet;
3.
The max. capacitive load offered is tested at nominal input voltage and full load;
4.
Unless otherwise specified, parameter indexes in this datasheet is measured under the conditions of Ta=25°C, humidity<75% with
nominal input voltage and rated output load;
5.
All testing methods in this datasheet are based on our Company’s corporate standards;
6.
The parameter indexes above are for the modules listed in this datasheet, for non-standard module's parameter indexes, please
contact our technicians for specific information;
7.
We can provide custom design;
8.
Specifications are subject to change without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2014.05.22-A/1
Page 4 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages