VER : D_5 update : 2016.09.01 AC-DC Medical MSC-E1 SERIES 40 Watts KEY FEATURES Switching Power Modules for PCB Mounting Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Output Low Ripple and Noise Isolation Class II CE, CB, UL, cUL, Approvals 3-Year Product Warranty ELECTRICAL SPECIFICATIONS Model No. ( Single Output ) Max output wattage Output (W) MSC-5S MSC-9S MSC-12S MSC-15S MSC-24S -E1 -E1 -E1 -E1 -E1 -E1 26.4W 40W 40W 3.3V 5V 9V 12V 15V 24V Voltage set accuracy 8000 ±2% 4444 ±2% 3333 ±2% 2666 ±2% 1667 ±2% Line regulation (typ.) 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1% 1% 1% 1% 1% 1% Load regulation (1-100%) (typ.) Minimum load 1% 1% 1% 1% 1% 1% Efficiency (typ.) 74% 79% 82% 83% 83% 83% 70000 uF 33000 uF 10000 uF 4000 uF 3000 uF 1200 uF ( Dual Output ) MSC-5D-E1 MSC-12D-E1 40W 40W (W) Output 2 Output 1 MSC-15D-E1 40W Output 2 Output 1 Output 2 Voltage (V.DC.) +5V -5V +12V -12V +15V -15V Current (mA) max 4000 4000 1666 1666 1333 1333 Voltage set accuracy ±2% ±2% ±2% Line regulation (typ.) 0.5% 0.5% 0.5% Load regulation (10-100%) (typ.) 1% (symmetric load) 1% (symmetric load) 1% (symmetric load) Cross regulation (typ.) 5% 5% 5% Minimum load 10% 10% 10% Efficiency (typ.) 80% 83% 83% ±6000 uF ±1000 uF ±2000 uF Maximum Capacitive Load (at 230 VAC) ( Dual Output ) Max output wattage MSC-5S12S-E1 (W) Voltage (V.DC.) Current (mA) max Voltage set accuracy Line regulation (typ.) Load regulation (10-100%) (typ.) Cross regulation (typ.) MSC-5S24S-E1 40W Output 1 Output 40W 8000 ±2% Output 1 Model No. 40W Current (mA) max Max output wattage Output 40W Voltage (V.DC.) Maximum Capacitive Load (at 230 VAC) Model No. MSC-3.3S 40W Output 2 Output 1 Output 2 5V 12V 5V 24V 5000 ±3% 1250 ±5% 5000 ±3% 625 ±5% 0.5% 5% 0.5% 5% 2% (symmetric load) 6% (symmetric load) 2% (symmetric load) 6% (symmetric load) 1% 7% 1% 7% Minimum load 25% 25% Efficiency (typ.) 80% 80% 15000 uF / 750 uF 15000 uF / 200 uF Maximum Capacitive Load (at 230 VAC) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- VER : D_5 update : 2016.09.01 AC-DC Medical MSC-E1 SERIES 40 Watts ELECTRICAL SPECIFICATIONS Model No. ( Triple Output ) Max output wattage Output MSC-5S12D-E1 MSC-5S15D-E1 40W 40W (W) Output 2 Output 3 Output 1 Output 2 Voltage (V.DC.) +12 -12 5 +15 Output 3 -15 Current (mA) max 600 600 500 500 Voltage set accuracy ±5% 5000 ±3% Line regulation (typ.) Load regulation (25-100%) (typ.) (symmetric load) Cross regulation (typ.) 5% 0.5% 5% 7% 3% 7% 7% Minimum load 3% 25% Efficiency (typ.) ±150 uF 7% 25% 79% Maximum Capacitive Load (at 230 VAC) ±5% 79% 18000 uF ±400 uF ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Input Output Protection Isolation Environment Physical Voltage 90-264 VAC or 100-375 VDC Frequency (Hz) 47-440 Hz Current (Full load) 860 mA max. (115 VAC) / 460 mA max. (230 VAC) Inrush current (<2ms) 55 A max. (115 VAC) / 95 A max. (230 VAC) Leakage Current < 0.1mA / 264 VAC (Touch Current) External fuse (recommend) 3.15 A slow blow type Ripple & Noise 3.3V:50mV of Vout Hold-up time 18 ms min. Over current protection Above 105% rated output power Over voltage protection Zener diode clamp Short circuit protection Hiccup mode, indefinite (automatic recovery) OTP Input-Output (V.AC) 4000V Operating temperature -40°C…+70°C (Case Temperature max. +95°C) Storage temperature -40°C…+85°C Temperature coefficient 0.01%/°C Humidity 95% RH 100°C MTBF 200,000 h~400,000 h @ 25°C Dimension (L x W x H) 3.5 x 2.5 x 1.06 Inches Case Material Plastic resin (flammability to UL 94V-0) ( 89.0 x 63.5 x 27.0 mm ) Tolerance 0.5 mm Weight 280 g Cooling method Free air convection Class II To IEC / EN 60536 cUL / UL / CB / ANSI/AAMI ES 60601-1: 2005, 1st Edition and CAN/CSA-C22.2 No. 60601-1:08, 2nd Edition, 2XMOPP EN 55011 class B Approval EMI Safety & EMC others:1% of Vout EMC Standards EN60601-1-2 ESD Susceptibility EN60601-1-2 Radiated Susceptibility EN60601-1-2 EFT / Burst EN60601-1-2 Surge EN60601-1-2 Conducted Susceptibility EN60601-1-2 Safety Approvals EN60601-1 http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : D_5 update : 2016.09.01 AC-DC Medical MSC-E1 SERIES 40 Watts NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. It's recommended to add Varistor 14S471K at L / N input side in parallel. 3. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw MECHANICAL DIMENSION (Top View) 5S/12S PIN# Single Dual Triple 5S/24S BLOCK DIAGRAM http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 1 AC IN (L) AC IN (L) AC IN (L) AC IN (L) 2 AC IN (N) AC IN (N) AC IN (N) AC IN (N) 3 +DC OUT +DC OUT +OUT2 +DC OUT 4 NO PIN NO PIN +OUT1 +5V 5 -DC OUT COMMON +OUT2 RTN COMMON 6 NO PIN NO PIN +OUT1 RTN +5 RTN 7 NOCONNECT -DC OUT NO PIN -DC OUT DERATING -3-