3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 Power line filters for three-phase systems Rated voltage 500, 690 and 760 V~ Rated current 150 A to 2500 A Construction ■ Three-line filter ■ Metal case Features ■ ■ ■ ■ Low leakage current Easy to install Very compact design B84143-B150...B600-S20: UL, CUL approval B84143-B150...B600-S21/S24: UL, CUL approval for 600/350 V~ ■ Optimized for operation under full load ■ Low weight Applications ■ ■ ■ ■ B84143-***-S24 for IT mains supply Frequency converters for motor drives Wind farms Power supplies Terminals ■ Busbars Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Typical circuit diagram LINE LOAD L1 L1’ L2 L2’ L3 L3’ SSB1212-L 255 03/01 3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 Technical data Rated voltage V R 500/290 V~, 50/60 Hz (type -S20) 690/400 V~, 50/60 Hz (type -S24); UL, CUL 600/350 V~ 760/440 V~, 50/60 Hz (type -S21);UL, CUL 600/350 V~ Rated current I R Referred to 40 °C ambient temperature Test voltage VP 2121 V–, 2 s (line/line) 2686 V–, 2 s (lines/case) type -S20 2890 V–, 2 s (lines/case) type -S21, -S24 Overload capability 1,5 · IR for 3 min per hour or 2,5 · IR for 30 s per hour Leakage current I leak at VR, 50 Hz Climatic category 25/100/21 (– 25 °C/+ 100 °C/21 days damp heat test) in accordance with EN 60068-1 Characteristics and ordering codes IR I leak Rtyp Approx. weight kg A mA µΩ 150 <6 140 13 B84143-B150-S** 180 <6 140 13 B84143-B180-S** 250 <6 63 15 B84143-B250-S** 320 <6 67 21 B84143-B320-S** 400 <6 67 21 B84143-B400-S** 600 <6 52 22 B84143-B600-S** 1000 <6 33 28 B84143-B1000-S** 1600 <6 22 34 B84143-B1600-S** 2500 <6 15 105 B84143-B2500-S** Ordering code Compilation of ordering code Replace the asterisks ** by the code number for the required version: 20 = 500 V 21 = 760 V 24 = 690 V (filter for IT mains supply. See also chapter “General, network types”, page 51) 256 03/01 3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 Dimensional drawings B84143-B150-S**, B84143-B180-S** 32±1 LOAD 6,6 97,5 115±0,2 2 x×M5 M5/ 5/ mm 5 mm tief deep 30 120 140 80 155±0,2 170 L3 L2 Marking LINE 36 L1 L1 L3 L2 3 91 260 150 32±1 2 97,5 81 141 10 10 20 310±2 ø9 PE M10 x 30 SSB1266-K B84143-B250-S** 60 LINE 36 LOAD 30 110 140 80 165 190 2 ø12 42±1 42±1 360±2 116 15 25 15 M6/ 6/ mm 6 mm 2 x×M6 tief deep L1 Marking L3 L2 L1 L3 L2 5 91 300 240±0,6 60 ø11 PE M10 x 30 257 03/01 SSB1206-C 3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 B84143-B320-S**, B84143-B400-S** 91 300 240±1 60 36 LINE LOAD ø12 42±2 15 30 180±0,5 210 2 16 42±2 15 85±0,5 116 25 360±2 120 235±1 260 L3 L2 L2 5 Marking L3 M6/ 6/ mm 6 mm 44 x×M6 tief deep L1 L1 60 ø11 PE M10 x 30 SSB1207-K B84143-B600-S** 91 350 290±1 60 60 36 LOAD 2 16 ø12 410±2,5 42±3 15 85±0,5 116 30 42±3 15 120 235±1 260 L2 LINE L3 L3 L2 5 Marking 30 180±0,5 210 L1 L1 4 x×M6 M6/ 6/ mm 6 mm tief deep ø11 PE M10 x 30 258 03/01 SSB1208-T 3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 B84143-B1000-S** 350 290±1 141 65 61 M6 6 mm 44x×M6 / 6 /mm tief deep L3 LOAD L3 LINE 160 L2 L2 275±1 300 Marking 40 220±0,8 250 8 L1 L1 65 2,5 16 ø12 52±3 52±3 20 135±0,8 166 20 40 420±2,5 ø14 PE M12 x 30 SSB1209-2 B84143-B1600-S** 400 340±1 105 141 105 61 20 40 220±0,8 250 L3 LOAD L3 LINE 92±3 275±1 300 L2 L2 Marking 160 10 L1 L1 4 x×M6 M6 6 mm / 6/mm tief deep 92±3 ø12 2,5 16 20 550±3 135±0,8 166 50 ø14 40 40 PE M12 x 30 259 03/01 SSB1210-5 3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 B84143-B2500-S** 650 560±1,5 125 191,5 91,5 125 4 × M6 / 20 93±3 ø14 3,5 16,5 20 810±3,5 190±1 221,5 40 40 80 40 200 L3 LOAD L3 LINE 93±3 355±1 385 L2 L2 Marking 60 286±1 320 L1 15 L1 mm/ 6deep 4 6x M6 tief ø14 PE M16 x 50 260 03/01 SSB1211-D 3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-B150-S20, B84143-B180-S20 B84143-B250-S20 SSB1267-T 100 SSB1799-S 100 dB αe dB αe 80 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 SSB1800-Z dB αe 80 60 40 20 0 10 4 10 5 10 6 10 7 10 6 10 7 Hz 10 8 f B84143-B320-S20 … B84143-B2500-S20 100 10 5 Hz 10 8 f 261 03/01 3-Line Filters B84143-B*-S20 for Converters and Power Electronics … B84143-B*-S24 Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-B150-S21, B84143-B250-S21 100 αe B84143-B320-S21 … B84143-B2500-S21 SSB1267-T dB αe 80 60 60 40 40 20 20 10 4 10 5 10 6 10 7 10 4 10 5 10 6 10 7 Hz 10 8 f B84143-B320-S24 … B84143-B2500-S24 SSB1801-8 100 SSB1268-2 100 dB αe dB 80 80 60 60 40 40 20 20 0 0 Hz 10 8 f B84143-B150-S24, B84143-B250-S24 αe dB 80 0 SSB1204-V 100 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 10 5 10 6 10 7 Hz 10 8 f 262 03/01 Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND ++49 89 636 09, FAX (0 89) 636-2 26 89 EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY ++49 89 636 09, FAX (0 89) 636-2 26 89 EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1