EPCOS B84143-B320-S24 3-line filters for converters and power electronic Datasheet

3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
Power line filters for three-phase systems
Rated voltage 500, 690 and 760 V~
Rated current 150 A to 2500 A
Construction
■ Three-line filter
■ Metal case
Features
■
■
■
■
Low leakage current
Easy to install
Very compact design
B84143-B150...B600-S20: UL, CUL approval
B84143-B150...B600-S21/S24: UL, CUL approval for 600/350 V~
■ Optimized for operation under full load
■ Low weight
Applications
■
■
■
■
B84143-***-S24 for IT mains supply
Frequency converters for motor drives
Wind farms
Power supplies
Terminals
■ Busbars
Marking
Marking on component:
Manufacturer’s logo, ordering code, rated voltage,
rated current, rated temperature, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Typical circuit diagram
LINE
LOAD
L1
L1’
L2
L2’
L3
L3’
SSB1212-L
255 03/01
3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
Technical data
Rated voltage V R
500/290 V~, 50/60 Hz (type -S20)
690/400 V~, 50/60 Hz (type -S24); UL, CUL 600/350 V~
760/440 V~, 50/60 Hz (type -S21);UL, CUL 600/350 V~
Rated current I R
Referred to 40 °C ambient temperature
Test voltage VP
2121 V–, 2 s (line/line)
2686 V–, 2 s (lines/case) type -S20
2890 V–, 2 s (lines/case) type -S21, -S24
Overload capability
1,5 · IR for 3 min per hour or
2,5 · IR for 30 s per hour
Leakage current I leak
at VR, 50 Hz
Climatic category
25/100/21 (– 25 °C/+ 100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
IR
I leak
Rtyp
Approx.
weight
kg
A
mA
µΩ
150
<6
140
13
B84143-B150-S**
180
<6
140
13
B84143-B180-S**
250
<6
63
15
B84143-B250-S**
320
<6
67
21
B84143-B320-S**
400
<6
67
21
B84143-B400-S**
600
<6
52
22
B84143-B600-S**
1000
<6
33
28
B84143-B1000-S**
1600
<6
22
34
B84143-B1600-S**
2500
<6
15
105
B84143-B2500-S**
Ordering code
Compilation of ordering code
Replace the asterisks ** by the code number for the required version:
20 = 500 V
21 = 760 V
24 = 690 V (filter for IT mains supply. See also chapter “General, network types”, page 51)
256 03/01
3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
Dimensional drawings
B84143-B150-S**, B84143-B180-S**
32±1
LOAD
6,6
97,5
115±0,2
2 x×M5
M5/ 5/ mm
5 mm
tief deep
30
120
140
80
155±0,2
170
L3 L2
Marking
LINE
36
L1
L1
L3 L2
3
91
260
150
32±1
2
97,5
81
141
10
10
20
310±2
ø9
PE M10 x 30
SSB1266-K
B84143-B250-S**
60
LINE
36
LOAD
30
110
140
80
165
190
2
ø12
42±1
42±1
360±2
116
15
25
15
M6/ 6/ mm
6 mm
2 x×M6
tief deep
L1
Marking
L3 L2
L1
L3 L2
5
91
300
240±0,6
60
ø11
PE M10 x 30
257 03/01
SSB1206-C
3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
B84143-B320-S**, B84143-B400-S**
91
300
240±1
60
36
LINE
LOAD
ø12
42±2
15
30
180±0,5
210
2
16
42±2
15
85±0,5
116
25
360±2
120
235±1
260
L3
L2
L2
5
Marking
L3
M6/ 6/ mm
6 mm
44 x×M6
tief deep
L1
L1
60
ø11
PE M10 x 30
SSB1207-K
B84143-B600-S**
91
350
290±1
60
60
36
LOAD
2
16
ø12
410±2,5
42±3
15
85±0,5
116
30
42±3
15
120
235±1
260
L2
LINE
L3
L3
L2
5
Marking
30
180±0,5
210
L1
L1
4 x×M6
M6/ 6/ mm
6 mm
tief deep
ø11
PE M10 x 30
258 03/01
SSB1208-T
3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
B84143-B1000-S**
350
290±1
141
65
61
M6
6 mm
44x×M6
/ 6 /mm
tief deep
L3
LOAD
L3
LINE
160
L2
L2
275±1
300
Marking
40
220±0,8
250
8
L1
L1
65
2,5
16
ø12
52±3
52±3
20
135±0,8
166
20
40
420±2,5
ø14
PE M12 x 30
SSB1209-2
B84143-B1600-S**
400
340±1
105
141
105
61
20
40
220±0,8
250
L3
LOAD
L3
LINE
92±3
275±1
300
L2
L2
Marking
160
10
L1
L1
4 x×M6
M6
6 mm
/ 6/mm
tief deep
92±3
ø12
2,5
16
20
550±3
135±0,8
166
50
ø14
40
40
PE M12 x 30
259 03/01
SSB1210-5
3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
B84143-B2500-S**
650
560±1,5
125
191,5
91,5
125
4 × M6 /
20
93±3
ø14
3,5
16,5
20
810±3,5
190±1
221,5
40
40
80
40
200
L3
LOAD
L3
LINE
93±3
355±1
385
L2
L2
Marking
60
286±1
320
L1
15
L1
mm/ 6deep
4 6x M6
tief
ø14
PE M16 x 50
260 03/01
SSB1211-D
3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84143-B150-S20, B84143-B180-S20
B84143-B250-S20
SSB1267-T
100
SSB1799-S
100
dB
αe
dB
αe
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
Hz 10 8
f
0
10 4
SSB1800-Z
dB
αe
80
60
40
20
0
10 4
10 5
10 6
10 7
10 6
10 7
Hz 10 8
f
B84143-B320-S20 … B84143-B2500-S20
100
10 5
Hz 10 8
f
261 03/01
3-Line Filters
B84143-B*-S20
for Converters and Power Electronics
… B84143-B*-S24
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84143-B150-S21, B84143-B250-S21
100
αe
B84143-B320-S21 … B84143-B2500-S21
SSB1267-T
dB
αe
80
60
60
40
40
20
20
10 4
10 5
10 6
10 7
10 4
10 5
10 6
10 7
Hz 10 8
f
B84143-B320-S24 … B84143-B2500-S24
SSB1801-8
100
SSB1268-2
100
dB
αe
dB
80
80
60
60
40
40
20
20
0
0
Hz 10 8
f
B84143-B150-S24, B84143-B250-S24
αe
dB
80
0
SSB1204-V
100
10 4
10 5
10 6
10 7
Hz 10 8
f
0
10 4
10 5
10 6
10 7
Hz 10 8
f
262 03/01
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
++49 89 636 09, FAX (0 89) 636-2 26 89
 EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese
Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten
Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die
zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
++49 89 636 09, FAX (0 89) 636-2 26 89
 EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this
brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be
considered as guaranteed characteristics. Purchase orders are subject to the General Conditions
for the Supply of Products and Services of the Electrical and Electronics Industry recommended by
the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1
Similar pages