SL Power GECA40 Wide-range ac input 90-264 vac Datasheet

GECA40
40 Watt Series
Commercial Wide-Range Input
2 Year Warranty
• Wide-Range AC Input 90-264 VAC
• Industry Standard Footprint - 3”x 5”x 1.25”
• Conducted EMI Exceeds FCC Class B and
CISPR 22 Class B
• Single and Multiple Outputs
• Approved to UL60950-1: 2003, CSA-22.2 No. 60950-1-03,
IEC and EN60950-1
• CB Report Available
• RoHS Compliant
•
Marked to LVD
Specifications
Unless otherwise noted, all parameters are nominal values measured at 120 VAC @25˚C and 0-95%
relative humidity, non-condensing. For limits at unusual operatiing conditions, consult factory.
AC Input
Universal Input 90-264 VAC, 47-63 Hz single phase.
Output Noise
0.5% rms, 1% pk-pk typical (see chart), 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the
power supply with load terminated with 0.1 μF capacitor.
Input Current
Maximum input current at 120 VAC, 60 Hz with full rated output load:
Multiple models 1.7 A, Single models 1.0 A.
Hold-Up Time
10 ms minimum with 40 W load, nominal line (120 VAC).
Output Power
40 W continuous, 45 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Overload Protection
Fully protected against short circuit and output overload. Short circuit
protection is cycling type power limit on V1 and V2, foldback type on V3.
Overvoltage Protection
On V1 is 120% to 160%. See chart.
Efficiency
75 to 80% at full rated load, nominal input voltage, depending on model
and load distribution.
Turn-on Time
Less than 2 seconds.
Input Protection
Internal AC fuse provided. Designed to blow only if a catastrophic failure occurs in the unit. Fuse does not blow on overload or short circuit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 VAC under cold
start conditions will not exceed 37A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Temperature Range
Designed for 0 to 45°C operation at full rated output power; derate output
current and total output power by 2.5% per °C above 45°C.
Transient Response
Main output—500 μs typical response time for return to within 0.5% of
final value for a 50% load step change. ∆i/ ∆t<0.2 A/μs. Maximum voltage
deviation is 3.5%. Startup/ shutdown overshoot less than 3%.
Switching Frequency
70 kHz +/-10 kHz.
Voltage Adjustment
Provided on V1. Adjustable voltages are preset at factory. Outputs are
capable of minimum +/- 5% change from nominal setting. Multiple output
models - V2 voltage will track V1 adjustment.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions
requirements:
EMI SPECIFICATIONS
COMPLIANCE LEVEL
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
EN55022 Class B; FCC Class B
EN61000-4-2, Level 3
EN61000-4-3, Level 3
EN61000-4-4, Level 3
EN61000-4-5, Level 3
Safety Approvals
SL Power Electronics, Corp. declares under our sole responsibility
that all GECA models are in conformity with the applicable requirements of
EN60950 following the provisions of the Low Voltage Directive 73/23/EEC.
All GECA models are approved to UL60950-1: 2003,
CSA-22.2 No. 60950-1-03, IEC and EN60950-1
MTBF
120kHrs.
SL Power Electronics, Corp. • 6050 King Drive • Ventura CA, 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com
GECA40
40 Watt Series
Commercial Wide-Range Input
Commercial
Model
GECA40AG
Output
No.
Output
(V)
Current
Minimum
Current
Maximum
Line
Regulation
V1
+5 V
0.35 A
3.5 A
+/-0.5%
V2
+12 V
0A
2A
+/-1%
V3
-12 V
0A
0.3 A
+/-1%
V1
+5 V
0.35 A
3.5 A
+/-0.5%
V2
+12V
0A
2A
V3
-5 V
0A
0.3 A
V1
+3.3 V
0.4 A
4A
+/-0.5%
V2
+12 V
0A
2A
+/-1%
GECA40BG
GECA40HG
V1 OVP
Set Point
+/-3%
Ripple &
Noise(P-P)
6.6 +/-0.9 V
50 mV
+/-10%
120 mV
+/-5%
120 mV
6.6 +/-0.9 V
50 mV
+/-1%
+/-10%
120 mV
+/-1%
+/-5%
50 mV
V3
-12 V
0A
0.3 A
+/-1%
V1
+5 V
0.35 A
3.5 A
+/-0.5%
V2
+24 V
0A
1.2 A
V3
-12 V
0A
0.3 A
GECA40DG
Load
Regulation
+/-3%
+/-3%
4.4 +/-0.6 V
50 mV
+/-10%
120 mV
+/-5%
120 mV
+/-3%
6.6 +/-0.9 V
50 mV
+/-1%
+/-10%
240 mV
+/-1%
+/-5%
120 mV
GECA40-5G
V1
5V
0A
7A
+/-0.5%
+/-3%
7.0 +/-1.0 V
50 mV
GECA40-12G
V1
12 V
0A
3.3 A
+/-0.5%
+/-3%
16.8 +/-2.4 V
120 mV
GECA40-15G
V1
15 V
0A
2.7 A
+/-0.5%
+/-3%
21.0 +/-3.0 V
150 mV
GECA40-24G
V1
24 V
0A
1.7 A
+/-0.5%
+/-3%
33.6 +/-4.8 V
240 mV
Environmental Specifications
GECA40 Series Mechanical Specifications
ENVIRONMENT
OPERATING
NON-OPERATING
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
0 to 45°C
20 to 90% RH
20 gpk
-500 to 10,000 ft
1.5 grms’ 0.0032 g2/Hz
-40 to +85°C
10 to 95% RH
40 gpk
-500 to 40,000 ft
5 grms’ 0.026 g2/Hz
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction,
3 orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.
CON 1:
MOLEX P/N 26-60-4030, w/center PIN Removed
0.156 [3.96 mm] CTR Header
CON 2:
MOLEX P/N 26-60-4060, 0.156 [3.96 mm] CTR Header
Input J1
PIN 1)
PIN 3)
AC Line
AC Neutral
Output J2
Multiple Output
Models
Single Output
Models
PIN 1)
PIN 2)
PIN 3)
PIN 4)
PIN 5)
PIN 6)
Output 2
Common
Common
Output 1
Output 1
Output 3
Output 1
Output 1
Output 1
Common
Common
Common
Mating Connector
MOLEX
Housing P/N
Contacts P/N
Input
09-50-3031
08-52-0072
Output
09-50-3061
08-52-0072
Note: 5A maximum recommended current per Connector PIN
Weight
1.0 lbs Max [0.45 kg Max.]
Tolerance
X.XX=0.030
X.XXX=0.010 [0.mm]
SL Power Electronics, Corp. • 6050 King Drive • Ventura CA, 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com
Data Sheet © 2006 SL Power Electronics, Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Rev.8/30/06
Similar pages