MPD MR1511S-03RU Ultra-wide input, 15w compact, railway dc/dc converter Datasheet

MR1511S Series
Ultra-Wide Input, 15W
Compact, Railway
DC/DC Converters
Electrical Specifications
Key Features:
• 15W Output Power
• 40 - 160 VDC Input Range
• Meets EN 60950, EN 50155
• 1,500 VDC Isolation
• Efficiency to 89%
• Compact 1 x 2 Inch Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Chassis Mount Option
• DIN Rail Mount Option
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
Input Filter
Conditions
Min.
40.0
Typ.
110.0
Max.
160.0
39.8
Units
VDC
VDC
VDC
Typ.
±1.0
±10
VIN = Min to Max
±0.2
IOUT = 10% to 100%
±0.5
See Note 1
75
500
25% Load Step Change
±3.0
110
130
±0.02
Continuous (Autorecovery)
Max.
±3.0
Units
%
%
%
%
mV P - P
µS
%
%
%/°C
Conditions
Max.
Units
VDC
M
pF
kHz
Max.
+85
+105
+125
Units
°C
°C
°C
95
%
IOUT = 100% 36.0
(Pi) Filter
Output
Parameter
Output Voltage Accuracy
Output Trim Range
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 2
Transient Response Deviation
Output Power Protection
Temperature Coefficient
Output Short Circuit, See Note 3
Conditions
Min.
±0.5
±1.0
100
800
±5.0
170
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
60 Seconds
500 VDC
100 kHz/0.1V
Min.
1,500
1,000
Typ.
2,000
300
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
See Mechanical Diagram (Page 4)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
0.99 Oz (28g)
Remote On/Off
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Unit On
Unit Off
Off Idle Current
Conditions
See Note 4
See Note 4
Min.
2.5
0
Typ.
Max.
12.0
1.2
Units
VDC
VDC
mA
Max.
Units
MHours
1.0
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Displacement Range
Acceleration
Vibration, 5 - 150 Hz
Min.
1.0
Typ.
7.5 mm
2G
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
Min.
-0.7
Typ.
1.5 mm From Case for 10 Sec
Max.
200.0
300
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
110
110
110
110
110
40 - 160
40 - 160
40 - 160
40 - 160
40 - 160
MR1511S-03RU
MR1511S-05RU
MR1511S-12RU
MB1511S-15RU
MB1511S-24RU
Output
Current (mA)
Voltage
Current
Current
Full-Load No-Load
(VDC)
(mA, Max)
(mA, Min)
120
153
155
155
155
15
15
8
8
8
Notes:
1. When measuring output ripple, it is recommended that an external ceramic capacitor
(approx 10 µF) be placed from the +VOUT to the -VOUT pins.
2. Transient recovery is measured to within a 1% error band for a load step change of 25%.
3. Short circuit protection is provided by a “hiccup mode” circuit.
4. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The
maximum control current to the on/off pin at logic low (-0.7V to 0.8V) is 1 mA. If the on/
off pin is left open, the unit operates. If it is grounded, the unit will shut off.
5. These units should not be operated with a load under 5% of full load. Operation at no-load
will not damage the unit, but they may not meet all specifications.
6. These units should not be operated over +85°C. Exceeding +85°C may damage the unit.
7. It is recommended that a fuse be used on the input of a power supply for protection. See
the Model Selection table above for the correct rating.
Efficiency vs Input Voltage (Full Load)
External Trim
3.3
5.0
12.0
15.0
24.0
4,000
3,000
1,250
1,000
625
Efficiency
(%, Typ)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection
Slow-Blow
(VDC Typ)
200
150
63
50
32
87
89
88
88
88
4.1
6.2
15.0
18.0
28.8
(µF, Max)
(mA)
4,020
4,020
1,600
1,000
470
300
300
300
300
300
Derating Curve
Efficiency vs Output Power (VIN= 110 VDC)
External Trim Notes:
On single output units, an external resistor can be used to adjust the converter
output up/down by about 10%. The connection is shown in the diagram at left. The
required resistor value is calculated by the formulas:
Trim UP = RTRIM = A $-R2 - R3
R2 A
Trim Down = RTRIM = A $-R1 - R3
R1 A
Where A =
VREF
$ R1
VTRIM - VREF
Where A = VTRIM VREF $ R2
VREF
Where RTRIM = Value of the external trim resistor
VTRIM = Amount of voltage adjustment required
The value of R1, R2, R3 and VREF are given in the table below.
Parameter
R1 (k)
R2 (k)
R3 (k)
VREF (V)
292 Page Street Ste D Stoughton, MA 02072
3.3
4.801
2.864
15.00
1.24
Output Voltage (VDC)
5.0
12
15
24
2.883 10.971 14.497 24.872
2.864
2.864
2.864
2.864
10.00
17.80
17.80
20.00
2.50
2.50
2.50
2.50
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
Parameter
Transient Input Voltage, See Note 1
Maximum Input Voltage, See Note 2
Radiated Emissions, See Note 3
Conducted Emissions, See Note 3
ESD
RS
EFT, See Note 4
Surge, See Note 5
CS
Voltage Dips
Standard
Criteria
RIA 12
A
385V/20mS Criteria A
B
1,800V (5/50 µS, 50 OR 100
EN 50155
B
8,400V (0.05/0.1 µS, 100
EN 55022
Class B
EN 55022
Class B
EN 61000-4-2
B
±6 kV Contact
EN 61000-4-3
A
10V/m
EN 61000-4-4
B
±2 kV
EN 61000-4-5
B
±2 kV/ ±4 kV
EN 61000-4-6
A
3 Vrms
EN 61000-4-29
B
0% - 70%
Notes:
1. With a pulse interval that is >60S. Requires the addition of the filter
module MDCFM-40U (or a similar discrete filter circuit) as shown in the circuit/
board layout diagrams below. Contact the factory for more information.
2. With a pulse interval that is >60S. Requires the addition of the filter
module MDCFM-40U (or a similar discrete filter circuit) as shown in the circuit/
board layout diagrams below. Contact the factory for more information.
3. All units will meet class B with the addition of the MDCFM-40U (or a similar
discrete filter circuit) as shown in the circuit/board layout diagrams below.
Contact the factory for more information.
4. To meet the requirements of EN 61000-4-4 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the MDCFM-40U.
Contact the factory for more information.
5. To meet the requirements of EN 61000-4-5 (±2 kV/±4 kV), external components are needed. This can be done discretely, or with the addition of the
MDCFM-40U. Contact the factory for more information.
5. Suggested component values are:
the MRxx11S product series, the MDCFM-40U DC filter modules are
recommended. For pricing or
Input
Vout Output
full technical information, please Vin
(VDC) Capacitor (VDC) Capacitor
contact the factory.
7. In many applications simply
3.3
470 µF
adding input/output capaci5
470 µF
tors will enhance the input
110
12
100 µF
220 µF
surge protection and reduce
15
220 µF
output ripple sufficiently.
24
100 µF
In this case, the capacitors
Typical Connection
The diagram above illustrates a typical connection of the MR1511S series The
MDCFM-40U filter module is used to make the circuit compliant with input
surge and EMC standards EN 55022, EN61000 and EN 50155. This can also be
accomplished by using external filter components as shown in the board layout
drawing below. Some notes on these components are:
1. It is recommended that an external fuse be used. The recommended fuse is
shown in the model chart on page 2.
2. An external MOV is recommended on the input to protect the unit in the event
of a surge. A recommended value is given in the table at right.
3. An external TVS is recommended on the input to protect the unit in the event
of a voltage spike. A recommended value is given in the table at right.
4. The output filtering capacitor (C3) is a high frequency, low resistance electrolytic
capacitor. Care must be taken in choosing this capacitor not to exceed the
capacitive load specification for the unit. Voltage derating of capacitors should
be 80% or above.
Component
MOV
L1
TVS
C1
C3
L2
CY1, CY2
Value
S14K130
56 µH
SMCJ170A
100 µF/200V
1.0 µF/50V
4.7 µH
1,000 pF/2 kV
6. Input noise and surge suppression modules are available
for a number of MPD DC/DC power supplies. For use with
C1 and C3 would be connected as shown without the other filter
components. Recommended capacitor values are given in the table
above.
Typical Board Layout: With External Filter/Surge Components
Typical Board Layout: With External Filter Module
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
1
2
3
4
5
6
+VIN
-VIN
+VOUT
Trim
-VOUT
Remote On/Off
1
2
3
4
5
6
+VIN
-VIN
+VOUT
Common
-VOUT
Remote On/Off
Adapter Plate
Mechanical Dimensions: With Optional Heatsink
All models of the MR1511S-xxRU series are available mounted
on an adapter plate similar to the one pictured above. The adapter
plate makes it easier to mount the unit to a chassis or to a standard
DIN rail. Please contact the factory for more information.
For the heatsink option, add suffix “H” to the
model number (i.e. MR1511S-xxRU-H)
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]