INPUT SPECIFICATIONS:
GENERAL SPECIFICATIONS:
Input Voltage Range........................................................ 12V............9-18V
24V............18-36V
48V............ 36-75V
Undervoltage lockout .............................. 12Vin power up ...............8.8V
power down .................8V
24Vin power up ............... 17V
power down ............. 16V
48Vin power up ............... 34V
power down ............. 32.5V
Positive Logic Remote ON/OFF ( see note 3 & 4 )
Input Filter ......................................................................................... PI Type
Efficiency....................................................................................See Table
Isolation Voltage ...........................Input/Output............ 1500VDC min.
Input/Case................ 1500VDC min.
Output/Case............ 1500VDC min.
Isolation Resistance ............................................................ 107 ohm min.
Switching Frequency ..................(12/24)Vin....................... 400KHz, Typ.
48Vin............................... 300KHz, Typ.
Operating Case Temperature ....................................... -40˚C to 100˚C
Storage Temperature .................................................. -55˚C to +105˚C
Thermal Shutdown, Case Temp. ...........................................100˚C Typ.
Dimensions ............................................................2.28x2.40x0.50 inches
(57.9x61.0x12.7 mm)
Case Material ..........................................................................Aluminum
OUTPUT SPECIFICATIONS:
Only for Nominal Input Voltage 24 & 48 VDC
Features
•
•
•
•
25W/50W Isolated Output
Efficiency to 85%
300KHz Switching Frequency
2 : 1 Input Range
•
•
•
•
Regulated Outputs
Continuous Short Circuit Protection
Five-Sided Metal Case
Industry Standard Half-Brick Package
Voltage Accuracy : ..................................................................... ±1% max.
Transient Response :25% Step Load Change ..........................<500µ sec.
External Trim Adj. Range ......................................................................±10%
Ripple & Noise, 20MHz BW, 2.5V & 3.3V & 5V .............. 20mV RMS., max.
75mV pk-pk, max.
12V & 15V .......................... 30mV RMS., max.
100mV pk-pk, max.
24V .......................... 100mV RMS., max.
240mV pk-pk, max.
Temperature Coefficient............................................................ ±0.03%/˚C
Short Circuit Protection..............................................................Continuous
Line Regulation1 ..........................................................................±0.2% max.
Load Regulation2 .......................................................................±0.2% max.
Over Voltage Protect trip Range, % Vo nom.............................115-140%
Current Limit .................................................110% ~150% Nominal Output
CHB50
S
NOTE:
1. Measured From High Line to Low Line.
2. Measured From Full Load to Zero Load.
3. Logic Compatibility .... Open Collector ref to -Input.
Module ON ....................Open Circuit
Module OFF................... <0.8Vdc
4. Suffix "N" to the Model Number with Negative Logic Remote
ON/OFF.
CASE HB
MODEL
NUMBER
INPUT
VOLTAGE
CHB50-12S25
OUTPUT
VOLTAGE
OUTPUT
CURRENT
2.5 VDC
10A
3.3 VDC
CHB50-12S33
10A
CHB50-12S12
12 VDC
CHB50-12S15
CHB50-12S24
9-18 VDC
2740 mA
10A
5 VDC
CHB50-12S05
INPUT CURRENT
NO LOAD
FULL LOAD
3525 mA
%EFF
76
5145 mA
81
4.16A
4950 mA
84
15 VDC
3.33A
4950 mA
84
24 VDC
2.08A
4950 mA
84
50 mA
Inches
Millimeters
HB
10A
1353 mA
77
CHB50-24S33
3.3 VDC
10A
1740 mA
79
5 VDC
10A
2540 mA
82
50 mA
.XX±.02
.X±.5
Mounting Inserts
M3*0.5 Through 4pl.
78
2.5 VDC
18-36 VDC
All Dimensions In Inches(mm)
Tolerances
CHB50-24S25
CHB50-24S05
CASE
1.40
(35.56)
2.00
(50.80)
.XXX±.01
.XX±.25
0.18 min.
(4.60)
2*R1.50
BOTTOM VIEW
4
5
3
6
0.60
(15.24)
7
8
2
2.40
(61.00)
CHB50-24S12
12 VDC
4.16A
2450 mA
85
1.90
(48.25)
CHB50-24S15
15 VDC
3.33A
2450 mA
85
2.28
(57.90)
CHB50-24S24
24 VDC
2.08A
2419 mA
86
CHB50-48S25
2.5 VDC
10A
676 mA
77
CHB50-48S33
3.3 VDC
10A
870 mA
79
CHB50-48S05
5 VDC
10A
1250 mA
83
CHB50-48S12
12 VDC
4.16A
1220 mA
85
CHB50-48S15
15 VDC
3.33A
1220 mA
85
CHB50-48S24
24 VDC
2.08A
1209 mA
86
PIN CONNECTION
Pin
1.
2.
3.
4.
5.
6.
7.
8.
9.
Ø0.08
(2.03)
2pl.
Function
+Vin
ON/OFF
CASE
-Vin
-Vout
-Sense
Trim
+Sense
+Vout
Ø0.04
(1.02)
7pl.
9
1
HB
Pin
±0.02
±0.5
0.50
(12.70)
External Output Trim
+SENSE (8)
Remote ON/OFF Control
+SENSE (8)
TRIM DOWN
36-75 VDC
69
50 mA
ON/OFF (2)
HB
TRIM (7)
TRIM (7)
HIGH SIGNAL HERE
DISABLE OUTPUT
TRIM UP
-VIN (4)
-SENSE (6)
NOTE : 1. Nominal Input Voltage 12, 24 & 48 VDC
RSG
ELECTRONIC COMPONENTS
-SENSE (6)
70
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
10K ohms
TRIMPOT
■
Änderungen vorbehalten / subject to change without notice
■
■
■
All Specifications Typical At Nominal Line, Full Load and 25˚C Unless Otherwise Noted.
Application Note
Remote ON/OFF Control
Derating
The CHB50 series allows the user to switch the module on and off electronically with remote on/off feature. The CHB50 series
are available with "positive logic" or "negative logic" (option).
The operating case temperature range of the CHB50 series is -40˚C to +100˚C. When operating the CHB50 , proper derating
or cooling is needed .
Logic Table
Following is the derating curve of CHB50 without heat sink.
ON/OFF (2)
(PIN 2)
Logic Low Power Dissipated vs Ambient Temperature and Air Flow
Power Disspated, Pd (Watts)
15
Natural Convection
20 ft./min. (0.1 m/s)
Switch Closed
HIGH SIGNAL HERE
DISABLE OUTPUT
Logic High -
-VIN (4)
100 ft./min. (0.5 m/s)
Switch Open
Negative Logic
Positive Logic
Module on
Module off
Module off
Module on
CHB50
Logic State
10
200 ft./min. (1.0 m/s)
300 ft./min. ( 1.5 m/s)
5
External Output Trimming
400 ft./min. (2.0 m/s)
Output may optionally be externally trimmed
0
0
10
20
40
30
50
60
70
80
90
100
(±10%) with a fixed resistor or an external
+SENSE (8)
+SENSE (8)
trimpot as shown.
Ambient Temperature, Ta(Deg. C)
TRIM DOWN
TRIM (7)
TRIM (7)
Forced Convection Power Derating with No Heat Sink
10K ohms
TRIMPOT
TRIM UP
-SENSE (6)
-SENSE (6)
Where:
External Output
The power dissipation (Pd):
Pd = Pi - Po = Po (1-
)/
The thermal resistance are list below:
Chart of Thermal Resistance vs Air Flow:
AIR FLOW RATE
TYPICAL Rca
Natural Convection
7.12 ˚C/W
100 ft./min.
6.21 ˚C/W
200 ft./min.
5.17 ˚C/W
300 ft./min.
4.29 ˚C/W
400 ft./min.
3.64 ˚C/W
Output Noise
The output noise is measured with 10µF tantalum capacitor and 1.0µF ceramic capacitor across output.
+Vout (9)
Ceramic
1.0µF
Resistor
Load
The temperature rise (
T ):
T = Pd * Rca
Solid Tantalum
10µF
To
Scope
-Vout (5)
Output Noise Test Circuit schematic
71
72
All Specifications Typical At Nominal Line, Full Load and 25˚C Unless Otherwise Noted.