HRS GT11N-2PP-HU

Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
GT11 Series
— Connectors for coaxial cables —
Features
Cost efficient termination
Highly efficient and reliable single motion crimp termination allows high volume production with semiautomatic equipment.
Lock-release latching system
Shock / vibration resistant electrical connections
Verification of the full contact insertion
77
For Double-Conductor coaxial shielded cable
F Connectors
Outer terminals
Part Number
CL No.
Applicable Cable
Item
Material
Finish
GT11-2S-5.2C
GT11-2S-6.0C
761-0002-3
761-0028-7
4.5 to 5.2mm
5.8 to 6.2mm
Outer terminal
Insulator
Brass
PT
Tin plating
Color: Dark gray
* The suitable terminals might differ depending on the internal structure of the cable.
Inner Terminals
Part Number
CL No.
Conductor Size (AWG)
Material
Finish
Packaging
GT11-1822SCF
GT11-2428SCF
761-0004-9
761-0020-5
#18 to 22
#24 to 28
Brass
Tin plating
8,000 pcs.
per reel
M Connectors
Outer terminals
Part Number
CL No.
Applicable Cable
Item
Material
Finish
GT11-2P-5.2C
GT11-2P-6.0C
761-0001-0
761-0027-4
4.5 to 5.2mm
5.8 to 6.2mm
Outer terminal
Insulator
Brass
PT
Tin plating
Color: Dark gray
* The suitable terminals might differ depending on the internal structure of the cable.
Inner Terminals
Part Number
CL No.
Conductor Size (AWG)
Material
Finish
Packaging
GT11-1822PCF
GT11-2428PCF
761-0003-6
761-0019-6
#18 to 22
#24 to 28
Brass
Tin plating
8,000 pcs.
per reel
78
For Double-Conductor coaxial cable
BShown with inserted retainer
F Connectors
Housing
Part Number
CL No.
Material
Color
GT11-2S-HU
761-0005-1
PBT
Light gray
M Connectors
Housing
BShown with inserted retainer
Part Number
CL No.
Material
Color
GT11-2P-HU
761-0006-4
PBT
Light gray
BShown with inserted retainer
BFully mated connector assemblies
Part Number
CL No.
Material
Color
GT11N-2PP-HU
761-0008-0
PBT
Light gray
79
M Connectors
BRecommended Board Mounting Pattern
Housing
For outer conductor
For inner conductor
パネル
Part Number
GT11-2S-HU
CL No.
Material
PBT
Brass
761-0005-1
PBT
Phosphor bronze
Finish
Color
---Tin plating
---Tin plating
Light gray
---Dark gray
----
BFully mated connector
assemblies
Housing (2-position Type)
BRecommended
Panel Cut-out
基板
BRecommended Board
Mounting Pattern
For outer conductor
For inner conductor
Part Number
GT11X-2/2P-DS
CL No.
Material
PBT
Brass
761-0022-0
PBT
Phosphor bronze
Housing (Straight Type)
Finish
Color
---Tin plating
---Tin plating
Light gray
---Dark gray
----
パネル
BRecommended Board Mounting Pattern
BFully mated connector assemblies
80
Part Number
CL No.
GT11-2P-DSA
761-0038-0
Waterproof type For Double-Conductor coaxial cable
F Connectors
Housing
BFully mated connector assemblies
Part Number
CL No.
Material
GT11W-2P-HU
761-0023-3
PBT
M Connectors
Housing
Part Number
CL No.
Material
GT11W-2S-HU
761-0024-6
PBT
Retainer (used with GT11W-2S-HU and GT11W-2P-HU)
Part Number
CL No.
Applicable Cable
GT11W-6.0R
761-0025-9
PBT
Silicon rubber compound
81
Waterproof type For Double-Conductor coaxial cable
F Connectors
Housing
BShown with inserted retainer
Part Number
CL No.
Material
Color
GT11K-2/2S-HU
761-0039-3
PBT
Light gray
* Mates only with GT11KN-2/2PP-HU.
M Connectors
Housing
BShown with inserted retainer
Part Number
CL No.
GT11KN-2/2PP-HU 761-0040-2
82
Material
Color
PBT
Light gray
BTermination sequence
6Insert the internal terminals into the Outer terminals.
1Strip the cable.
Shield
The joined side of the crimp portion faces upward
(for both male and female).
Cable
2Cut the shield and expose the wire.
Wire
7Crimp the Outer terminal.
3Cut back the shield above the sheath and wrap with
conductive tape.
The shield must be visible.
Jig used: Outside tube caulking jig.
(Refer to Page 91 for detail.)
8Insert the terminal into the housing.
(Please insert until the terminal is stopped by the lance.)
4Strip the wire and form it.
Conductor
Jig used: Cable-forming strip jig
(Refer to Page 85 for detail.)
5Crimp the wire to the internal terminal.
1mm max.
Jig used: Automatic crimping machine.
(Refer to Page 85 for detail.)
9Mount the retainer to complete the task.
Refer to Page 84 for information
about the retainer mounting
method.
83
BRetainer Mounting Method
a. Insert so that the terminal
locking tab is inserted
between the top surface
of the terminal and the
housing.
b. Push in while changing
the angle of the retainer
until the front surface
comes to a stop.
c. Press the rear portion of
the retainer and snap it
into the locked position.
d. If locking is not complete,
press the rear portion of
the retainer again while
pulling it backward.
* Check that all locations are locked.
* Check that the bands are housed in all of the receiving areas.
84
BTermination Tools
User's manuals are available. Please ask your Hirose Electric account representative.
Cable-Forming Strip Jig (for 2-conductor cable)
Main Unit
Accessory (Electrical Box)
Specifications
Remarks
Capacity
Mounting Dimensions Approximately 400 W x 500 D x 300 H
Approximately 40 kg
Weight
Approximately 5 kg
AC100V (50/60Hz)
Power supply
Part Number CT11-ST/AD
Approximately 300 W x 250 D x 200 H
Air pressure
5-6Kgf/cm
Task time
Approximately 14 seconds
Automatic Crimping Machine (for 2-conductor and 8-conductor cable)
Specifications
Item
Specification
Capacity
1.5tons
Stroke
30mm
Number of strokes
200spm (50Hz)
Weight
75kg
Remarks
200spm (60Hz)
Motor
0.2kW
Crimping speed
2000 to 4000 pcs. per day
AC100V
Part Number CM-105
Cable-Forming Strip Jig (for 2-conductor cable)
Main Unit
Accessory (Electrical Box)
Specifications
Specification
Remarks
Mounting Dimensions Approximately 300 W x 400 D x 300 H
Weight
Approximately 300 W x 250 D x 200 H
Approximately 25 kg
Approximately 5 kg
Power supply
AC100V (50/60Hz)
Air pressure
5-6Kgf/cm
Part Number CT11-CT/AD
* Crimp height setting tables are available for each cable type. Please contact your nearest Hirose Electric account representative.
Different cables will require different crimp height settings.
85
For 8-Conductor coaxial shielded cable
F Connectors
Inner Terminal
Part Number
GT11-1822SCF
GT11-2428SCF
CL No.
761-0004-9
761-0020-5
Conductor Size (AWG)
Material
#24 to 28
Phosphor bronze
#24 to 28
Phosphor bronze
Insulator
Part Number
GT11-8DS-2.8C
CL No.
761-0014-2
Material
PBT
Outer terminals
Part Number
GT11-8DS-5C
86
CL No.
761-0015-5
Material
Brass
Finish
Phosphor bronze
Finish
Tin plating
Tin plating
Shield Plate
Part Number
GT11-8DS-SB
CL No.
761- 0016-8
Material
Brass
CL No.
761-0017-0
Material
PBT
Finish
Tin plating
Housing
Part Number
GT11-8DS-HU
Retainer (used with GT11-8DS-HU)
Part Number
GT11-8DS-6R
CL No.
761-0018-3
Material
PBT
87
M Connectors
Inner Terminals
Part Number
GT11-1822PCF
GT11-2428PCF
CL No.
761-0003-6
761-0019-6
Conductor Size (AWG)
Material
#18 to 22
Phosphor bronze
#24 to 28
Phosphor bronze
Insulator
Part Number
GT11-8DP-2.8C
CL No.
761-0009-2
Material
PBT
Outer terminals
Part Number
GT11-8DP-5C
88
CL No.
761-0010-1
Material
Brass
Finish
Phosphor bronze
Finish
Tin plating
Tin plating
Shield Plate
Part Number
GT11-8DP-SB
CL No.
761-0011-4
Material
Brass
CL No.
761-0012-7
Material
PBT
Finish
Phosphor bronze
Housing
Part Number
GT11-8DP-HU
Retainer (Used with GT11-8DS-HU)
Part Number
CL No.
GT11-8DP-6R
761-0013-0
* Reserved for product expansion
Material
PBT
89
Printed Circuit Board Type
BRecommended Board Mounting Pattern
BFully mated connector assemblies
Board
90
Part Number
CL No.
GT11-8DP-2.8DS
761-0021-8
Item
Material
Housing
PBT
Outer Terminal Phosphor bronze
Insulator
PBT
Terminal
Brass
Finish
Tin plating
Tin plating
BTermination sequence
6Insert the inner terminals into the insulated case.
1Strip the Cable.
Inner terminal
Cable
Shield
2Cut the shield and expose
the wire.
7Insert what was made in Step 6 into the Outer
terminals.
Outer terminals
Wire
3Cut back the shield above
the sheath and wrap with
conductive tape.
8Insert the caulking shield cover onto the Outer
terminals.
Shield cover
Conductive tape
9Insert what was made in Step 8 into the housing.
4Strip the wire.
Housing
5Crimp the internal terminals.
!0Insert the retainer.
Internal terminals
Retainer
Completion
91
BTermination Tools
User's manuals are available. Please ask your Hirose Electric account representative.
Cable-Forming Strip Jig (for 2-conductor cable)
Main Unit
Accessory (Electrical Box)
Specifications
Remarks
Capacity
Mounting Dimensions Approximately 400 W x 500 D x 300 H
Approximately 300 W x 250 D x 200 H
Approximately 40 kg
Weight
Approximately 5 kg
Power supply
AC100V (50/60Hz)
Air pressure
5-6Kgf/cm
Task time
Approximately 14 seconds
Part Number CT11-ST/AD
Automatic Crimping Machine (for 2-conductor and 8-conductor cable)
Specifications
Item
Specification
Remarks
Capacity
1.5Ton
Stroke
30mm
Number of strokes
200 spm (50Hz)
Weight
75kg
Motor
0.2kW
Crimping speed
2000 to 4000 pcs. per day
240spm (60Hz)
AC100V
Part Number CM-105
Cable-Forming Strip Jig (for 2-conductor cable)
Main Unit
Accessory (Electrical Box) Specifications
Specification
Remarks
Mounting Dimensions Approximately 300 W x 400 D x 300 H
Weight
Approximately 300 W x 250 D x 200 H
Approximately 25 kg
Approximately 5 kg
Power supply
AC100V (50/60Hz)
Air pressure
5-6Kgf/cm
* Crimp height setting tables are available for each cable type. Please contact your
nearest Hirose Electric account representative.
Different cables will require different crimp height settings.
Part Number CT11-CT/AD
Outer terminal Caulking Jig (for 8-conductor cable)
Hand Press
Part Number GT11-8S/P-HP
92