TOTAL POWER INT'L MAU200 TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -2- TOTAL POWER INT'L MAU200 Environmental Specifications Parameter Conditions Min. Typ. Max. Unit Operating Temperature -25 --- +85 ] Storage Temperature -40 --- +125 ] --- --- 95 % Max. Unit Humidity Cooling Free-Air Convection Input Specifications Parameter Model Input Voltage Range Reverse Polarity Input Current Min. 5V Input Models 4.5 5 5.5 12V Input Models 10.8 12 13.2 24V Input Models 21.6 24 26.4 --- --- 0.3 All Models Input Filter Typ. VDC A Internal Capacitor Output Specifications Parameter Conditions Min. Typ. Max. Unit --- {1.0 {3.0 % Dual Output Balance Load --- {0.1 {1.0 % Line Regulation For Vin Change 1% --- {1.2 {1.5 % Load Regulation Io=20% to 100% Output Voltage Accuracy Output Voltage Balance See Model Selection Guide Ripple & Noise (20MHz) % --- 65 100 mV P-P --- --- 150 mV P-P Ripple & Noise (20MHz) --- --- 5 mV rms. Over Load 120 --- --- % --- {0.01 {0.02 %/] Ripple & Noise (20MHz) Over Line,Load & Temp. Temperature Coefficient Output Short Circuit 0.5 Second Max. General Specification Parameter Rated Isolation Voltage Isolation Resistance Isolation Capacitance Conditions Min. Typ. Max. Unit 60 Seconds 3000 --- --- VDC 500VDC 10 --- --- G[ 100KHz,1V --- 60 100 pF 70 100 120 kHz Switching Frequency Input Fuse Selection Guide 5V Input Models 12V Input Models 24V Input Models 500mA Slow - Blow Type 200mA Slow - Blow Type 100mA Slow - Blow Type TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -3- TOTAL POWER INT'L MAU200 Typical Applications + +Vin Fuse + -Vin +Vin Fuse Single Output DC / DC Converter DC Power Source - +Out DC Power Source Load -Out - +Out Dual Output DC / DC Converter -Vin Load #1 Common Load #2 -Out Derating Curve 3.3, 5 & {5V Only Output Power % 100 100 80 80 60 60 40 40 O -3.3% / C 20 20 0 0 -25 -10 0 20 40 60 80 Ambient Temperature All Other Output Output Power % Output Power % 100 125 O C 100 100 80 80 60 60 40 40 -5% / OC 20 Output Power % 20 0 0 -25 -10 0 20 40 60 Ambient Temperature 80 100 125 O C Connecting Pin Patterns (2.54 mm / 0.1 inch grids ) Single Output Dual Output NOTE: 1. Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted. 2. Other input and output voltage may be available,Please contact factory. 3. Specifications subject to change without notice. TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -4-