AZ21001 40 AMP MINIATURE POWER RELAY FEATURES • • • • • • • Quick-connect leads for contacts 1 Form A, B and C contacts available AC and DC coils available Class F high temperature available Epoxy sealed versions available UL, CUR file E44211 TÜV Pending GENERAL DATA CONTACTS Arrangement Ratings UL, CUR Life Expectancy Mechanical Electrical Minimum operations 1 x 107 1 x 105 at 30 A 120 VAC Res. N.O. Operate Time 15 msec max. at nominal coil voltage Max. switched power: 1100 W or 7200 VA Max. switched current: 40 A (Form A) Release Time 10 msec max. at nominal coil voltage (without suppression) Max. switched voltage: 300 VAC, 110 VDC Dielectric Strength NO: 40A at 240 VAC 30A General Purpose 2HP at 250 VAC, 277 VAC 1500 Vrms contact to contact 2500 Vrms contact to coil Insulation Resistance 1000 megohms min. at 20°C, 500 VDC 50% RH Dropout DC: > 10% of nominal coil voltage AC: > 30% of nominal coil voltage Ambient Temperature Operating Storage -55°C -55°C -55°C -55°C SPST (1 Form A, or B) SPDT (1 Form C) Resistive load: NC: 30A at 240 VAC , 30A at 30 VDC 20A General Purpose 11/2 HP at 250 VAC, 277 VAC TÜV NO: 40A at 240 VAC, 14 VDC NC: 30A at 240 VAC, 14 VDC (at sea level for 1 min.) (-67°F) (-67°F) (-67°F) (-67°F) to to to to 100°C 130°C 125°C 155°C (212°F) (266°F) (257°F) (311°F) Class Class Class Class B B F F Material Silver cadmium oxide [1], silver tin oxide [2] Vibration 0.062" DA at 10–55 Hz Resistance < 50 milliohms initially (24 V, 1 A voltage drop method) Shock 10 g Enclosure P.B.T. polyester Terminals Tinned copper alloy, P.C., Quick Connects Note: Allow suitable slack on leads when wiring, and do not subject the terminals to excessive force. COIL Power At Pickup Voltage (typical) DC: 500 mW AC: 1.4 VA Max. Continuous Dissipation DC: 1.7 W at 20°C AC: 2.7 VA at 20°C Max. Temperature Max. 130°C (266°F) Class B Max. 155°C (311°F) Class F Max. Solder Temp. 270°C (518°F) Max. Solder Time 5 seconds Max. Solvent Temp. 80°C (176°F) Max. Immersion Time 30 seconds Weight 30 grams NOTES 1. All values at 20°C (68°F). 2. Relay may pull in with less than “Must Operate” value. 3. Specifications subject to change without notice. 3/10/09 AZ21001 RELAY ORDERING DATA COIL SPECIFICATIONS – DC Coil Nominal Coil VDC 3 Must Operate VDC 2.25 Max. Continuous VDC 3.9 Nominal Current mA ± 10% 300 Coil Resistance ± 10% 10 ORDER NUMBER* AZ21001–1A–3D 5 3.75 6.5 179 28 AZ21001–1A–5D 6 4.50 7.8 150 40 AZ21001–1A–6D 9 6.75 11.7 100 90 AZ21001–1A–9D 12 9.00 15.6 75 160 AZ21001–1A–12D 15 10.25 19.5 60 250 AZ21001–1A–15D 18 13.5 23.4 50 360 AZ21001–1A–18D 24 18.0 31.2 38 640 AZ21001–1A–24D 62.4 19 2,560 8 13,445 48 36.0 110 82.50 143 AZ21001-1A–48D AZ21001–1A–110D COIL SPECIFICATIONS – AC Coil 50/60 Hz Nominal Coil VAC 12 Must Operate VAC 9 Max. Continuous VAC 15.6 Nominal Coil Power VA 2.0 Coil Resistance ± 10% 27 31.2 2.0 120 ORDER NUMBER* AZ21001–1A–12A 24 18 120 90 156 2.0 3,040 AZ21001–1A–24A AZ21001–1A–120A 220 165 286 2.0 13,490 AZ21001–1A–240A *Substitute “-1B” or “-1C” in place of “-1A” for 1 Form B or 1 Form C respectively. For silver tin oxide contacts substitute “-1AE” or “-1CE” in place of “-1A” or “1C.” To indicate class F version, add suffix “F”. Substitute “DE” or “AE” in place of “D” or “A” for epoxy sealed version. MECHANICAL DATA Outline Dimensions PC Board Layout 32.4Max. 1.275Max. 8 32.4 Max. 1.275max. 3-6.35 0.250 10 0.394 2-0.8 1.5 0.031 0.059 0.606 0.303 0.083 0.701 0.150 0.551 0.4 0.016 3.3¡ À 00.5 .5 3.3 0.130 0.020 2- 0.8 0.031 1.2 1.2 0.047 0.047 3-0.8 0.031 28Max. 1.102max. 27.5 Max. 1.083max. 8 0.315 27.5Max. 1.083Max. 10 0.394 17.3 0.681 7.7 0.303 12.3 0.484 28Max. 1.102 M ax. 0.020(0.130) 6 0.236 0.5 0.020 5 0.75 0.029 5.4 0.213 0.197 0.5 (3.3) 0.75 0.037 0.315 0.043 0.1 Wiring Diagram FORM 1B FORM 1A 3 4 FORM 1C 5 3 2 2 1 3 5 4 2 1 1 Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010" 3/10/09