Nova GL3K60-270 Dc--ac iinverter Datasheet

ULTRA-LIGHTWEIGHT
RUGGED GALAXY™ SERIES DC-AC INVERTER
COMPACT 3U CHASSIS
2 - 5KVA OUTPUT POWER
270 VDC NOMINAL WIDE RANGE INPUT
OPTIONAL SNMP COMMUNICATIONS
WHEN EVERY POUND COUNTS
COUNTS!
APPLICATIONS
APP
P L I C ATIONS
S
Utilizing field proven fully isolated topology, this family
of rugged Inverters is suitable for harsh environments and
can be customized for unique applications including:
Shelters
Tactical Systems
Shipboard power
Servers
MIL-STD-810
MIL-S-901
HMMWVs
Mobile Systems
Ground support
Transit Cases
MIL-STD-461
MIL-STD-167
ELECTRIC
NOVA ELE
ECTRIC
www.novaelectric.com
[email protected]
A Leader in DC-AC Inverter Technology since 1966 - 500VA to 500+KVA
MADE IN USA
ULTRA-LIGHTWEIGHT PURE SINEWAVE DC-AC INVERTER
MEETS MIL-STD-810, MIL-STD-167, MIL-S-901, MIL-STD-740, & MIL-STD-461
APPLICATIONS
ELECTRICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
The rugged Ultra Lightweight Galaxy Series
Inverter is designed to provide years of reliable
service in harsh shock, vibration, humidity, and
EMI environments. Applications include Submarine,
Shipboard, HMMVW, UAV, Shelter, and Mobile
Power Units.
Input Voltage: 270 VDC Nominal,
180-355 VDC Operating Range
(other ranges available)
Output Voltage: 120, 208, or 230 VAC (specify)
Frequency: 50 / 60 / 400 Hz. Available
Voltage Regulation: ± 2% NL to FL
Frequency Regulation: ± 0.5% NL to FL
Harmonic Distortion: 5% THD, 3% typical
Input Power Factor: 0.95 or Better @ half-full load
(except 3 phase input models)
Efficiency at full load: 85% @ full load typical
Connections: MS Connector (mates optional)
UPS Operating Temp.: -20° to +55°C
(Extended ranges optional - Consult factory)
UPS Storage Temp. Range: -40° to +71°C
Humidity: to 95% non-condensing
Elevation: 15,000 Ft. (4,572m) operating;
40,000 ft. (12,192m) non-operating
Shock: 20g for 11mS
Audible Noise: Less than 55 dbA at 5 ft.
OPTIONS
■ 400 Hz Output
■ High IP Protection for front / rear panels
■ AUX DC Outputs
■ Ruggedization against high shock, vibration and
humidity
■ MS connector mates and multiple output outlets
■ Chassis Slide Guides
■ Electromechanical transfer switch
■ Custom Enclosures
■ CAD Free Connectors
■ Non-PVC wiring
■ Bulkhead mounting
NOMINAL DIMENSIONS
5.25" x 19" x 24"
OPTIONAL INDICATORS
Status (Red / Green)
Inverter Off (Red)
Logic Fault (Red)
Over Temperature (Red)
Load on Utility (Red) Optional with transfer
switch
OPTIONAL REMOTE CONTACTS/COMMUNICATIONS
SNMP V1.0 via CAT-5 Connector
Major Alarm: Logic Fault, Overtemperature,
Overload
Minor Alarm: Utility Off
RS 232 (Available-Optional) Via DB 9 Connector
Alarm Contacts(Available-Optional)
OPTIONAL PROTECTIVE FEATURES
DC Input Circuit Breaker, AC Output Circuit Breaker,
and Audible Alarm with Silence Switch
PARTIAL MODEL SELECTION
120 VAC OUTPUT MODELS
OUTPUT
OUTPUT VAC FREQUENCY
CONTINUOUS
OUTPUT
POWER
WEIGHT LBS.
220 VAC OUTPUT MODELS
SIZE
OUTPUT
OUTPUT VAC FREQUENCY
CONTINUOUS
OUTPUT
POWER
WEIGHT LBS.
SIZE
(HxWxD)
(HxWxD)
MODEL
GL2K60-270
120 VAC
60 Hz
2KVA
55
5.25" x 19" x 24"
GL2K50-270(220)
220 VAC
50 Hz
2KVA
55
5.25" x 19" x 24"
GL3K60-270
120 VAC
60 Hz
3KVA
57
5.25" x 19" x 24"
GL3K50-270(220)
220 VAC
50 Hz
3KVA
57
5.25" x 19" x 24"
220 VAC
50 Hz
4KVA
60
5.25" x 19" x 24"
220 VAC
50 Hz
5KVA
60
5.25" x 19" x 24"
MODEL
GL4K60-270
120 VAC
60 Hz
4KVA
60
5.25" x 19" x 24"
GL4K50-270(220)
GL5K60-270
120 VAC
60 Hz
5KVA
60
5.25" x 19" x 24"
GL5K50-270(220)
WEB : www.novaelectric.com
E-Mail : [email protected]
PHONE : (201) 385-0500 FAX : (201) 385-0702
NOVA ELECTRIC
A Division of
TECHNOLOGY DYNAMICS, INC.
100 School St., Bergenfield NJ 07621