Technical Data 10209 Effective December 2015 Supersedes September 2014 BUSSMANN SERIES BSPD surge protective devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels Contents Description Page Introduction 2 Applications 2 Features 2 Standards and certifications 2 Configuration 3 Enclosure options, dimensions, and weights Voltage protection ratings 3 4-5 Specifications 6 Catalog number system 7 Technical support information 7 Technical Data 10209 BSPD SPDs for overvoltage protection on switchgear and power distribution panels Effective December 2015 Introduction Factory sealed to improve electrical safety The BSPD surge protective devices are tested by Underwriters Laboratory and Listed to UL® 1449, 3rd Edition to help ensure equipment is protected with highly reliable surge protection technology. Delta and Wye system units are available in three configurations to increase application flexibility. The BSPD Series is for installation external to an electrical enclosure or panelboard. Application of BSPD Series units throughout a facility will help ensure that equipment is protected. All BSPD units are factory-sealed to eliminate arc flash and shock hazards, as the user/installer has no chance of coming into contact with energized parts. The units also contain no user-serviceable parts or wire lugs that require periodic retightening to eliminate the need for periodic maintenance. Applications BSPD units are available for common Delta and Wye system voltages in a variety of surge current capacity ratings from 120kA to 400kA. Available in three configurations, the BSPD Series’ features and options make it easy to specify units for many electrical applications including service entrances, distribution switchboards, panelboards and point-of-use. All possible combinations of product attributes are available for ordering in the catalog number system (see page 7). Features • BSPD uses Bussmann series SurgePOD™ thermally protected Metal Oxide Varistor (MOV) technology to safely shunt overvoltages to ground while its thermal disconnect capability eliminates the need for additional fusing BSPD uses Bussmann series SurgePOD modules that each contain an internal element that safely disconnects upon reaching an overvoltage breakdown condition. Prewired All BSPD units are factory wired for ease of installation. Simply install any necessary conduit runs, mount the unit and make all wire connections. No need for internal wiring or access to the unit’s inside. Compact size takes less space Available in enclosures that are up to 50% smaller than other products with comparable ratings the BSPD Series come in NEMA® 1 and 4X enclosures that differ in size according to their surge current capacity (Imax). NEMA 1 BSPD units. • The 120-200kA surge current capacity units are housed in a 74 square-inch enclosure that is only 3-1/2 inches deep. Models available to meet the overvoltage protection needs of Wye and Delta electrical systems from 208 to 600 volts, 3-phase • The 300-400kA surge current capacity units are housed in a 74 square-inch enclosure that is only 6 inches deep. BSPD has the highest nominal discharge current (In) of 20kA per UL 1449 3rd Edition. This rating indicates the SPD’s ability to handle a number of large-magnitude surges over a short period of time and remain operational. • The 120-200kA surge current capacity units are housed in a 108 square-inch enclosure that is only 5-3/8 inches deep. • The 300-400kA surge current capacity units are housed in a 108 square-inch enclosure that is only 7-11/16 inches deep. • 200kA SCCR meets the highest NEC® requirements • • Bussmann series SurgePOD technology eliminates the need for additional fusing • 120kA to 400kA surge current capacity (Imax) ratings meet the needs of larger switchgear and power distribution panel applications • Optional Form C contact relay, EMI/RFI filtering and surge counter available to meet additional system requirements. • 200kA Short-Circuit Current Rating (SCCR) • NEMA 1 or NEMA 4X enclosures • RoHS compliant • 10 year warranty NEMA 4X BSPD units. Agency information • Basic, standard and standard withsurge counter configurations UL Listed, 1449 3rd Edition, File E316410, Guide VZCA, CSA® Certified, Notice 516, File 243397 • Standard and standard with surge counter configurations are also UL Recognized, 1283 5th Edition, File E316410, Guide VZCA2, CSA component acceptance, Std. C22.2, No. 8-M1986, File 243397 BSPD unit mounted externally to a Bussmann series Quik-Spec™ Coordination Panelboard 2 Eaton.com/bussmannseries BSPD SPDs for overvoltage protection on switchgear and power distribution panels Technical Data 10209 Effective December 2015 Dimensions - in (mm) and weights Enhanced protection status indicators Unlike many SPDs that only have single-color indicators, all BSPD units include green and red Light Emitting Diodes (LEDs) that indicate the true protection status for each phase. 7.28 (184.9) 5.27 (133.9) If power is removed from any one phase, the unit’s LEDs continue to indicate the protection status on that phase — regardless if power is applied to the phase. This feature ensures proper indication. Although many SPDs on the market have N-G surge protection, they do not always have a means of monitoring and indicating the protection status of that mode. All BSPD units for Wye systems also contain green and red LED surge protection status indicators for the Neutral-to-Ground (N-G) connection. Like the phase protection status LEDs, the N-G protection status LEDs show the true protection status in the N-G mode. By specifying the BSPD, users are supplied with accurate information concerning the surge protection status of their electrical systems. Configurations 10.48 (266.2) 12.05 (306.1) The BSPD provides users with three configurations. These are: • Basic (UL Type 1 - can be installed in UL Type 2 locations) • Standard (UL Type 2) • Standard with surge counter (UL Type 2) 11.25 (285.8) 0.68 (17.3) 5.24 (133.1) 0.78 (19.8) 1.00 (25.4) 2.00 (50.8) 3.48 (88.4) 4.41 (112.0) Ø0.20 (Ø5.1) 7.47 (189.7) 0.40 (10.2) Figure 1. NEMA 1, 120kA-200kA Units, Weight = 6.8 Lbs (3.1 kg) 5.47 (138.9) The proper configuration can be selected based on application requirements or specification. 1.00 (25.4) Table 1. configuration comparisons Configuration Feature Surge protection using thermally protected MOV technology Green and red LED protection status indicators for each phase Green and red LED protection status indicators for the Neutralto-Ground protection mode (Wye systems only) Basic (Type 1) Standard (Type 2) Standard with surge counter (Type 2) X X X X X X X Audible alarm with silence button X X Form C relay contact X X EMI/RFI filtering, providing up to 50dB of noise attenuation from 10kHz to 100MHz X X Surge counter with reset button held in nonvolatile memory X X 12.05 (306.1) 10.48 (266.2) 0.67 (17.0) 5.24 (133.1) 0.78 (19.8) 11.25 (285.8) 2.00 (50.8) 5.76 (146.3) 6.69 (169.9) Ø0.20 (Ø5.1) 7.47 (189.7) 0.40 (10.2) Figure 2. NEMA 1, 300kA-400kA Units, Weight = 13.5 Lbs (6.1 kg) X 120-200kA 250-400kA A 2.60 (66.0) 4.10 (104.1) B 5.39 (137.0) 7.68 (195.0) Figure 3. NEMA 4X, 120kA-400kA Units, Weight = 120-200kA; 14.6 Lbs (6.6 kg), 250-400kA; 21.0 Lbs (9.5 kg) Eaton.com/bussmannseries 3 Technical Data 10209 BSPD SPDs for overvoltage protection on switchgear and power distribution panels Effective December 2015 Voltage protection ratings ANSI/UL 1449 3rd Edition voltage protection ratings Voltage Protection Rating (VPR) data for all units is included in the following tables, The data varies based upon the configuration and NEMA enclosure. VPR values for the Basic configurations are on the left-hand side of the page. Tables on the right-hand side contain VPR values for the Standard or Standard with Surge Counter configurations. NEMA 1: Basic (cat. nos. ending with 1K) NEMA 1: Standard or Standard w/ Surge Counter (cat. nos. ending with 2K or 3K) Table 2. 120-200kA Table 5. 120-200kA Voltage/ system code Protection mode L-N L-G N-G L-L Protection mode L-N L-G N-G L-L 208Y 700 700 700 1200 208Y 600 800 600 1000 480Y 1200 1200 1200 2000 480Y 1200 1200 1200 1800 600Y 1500 1500 1500 2500 600Y 1500 1500 1500 2500 240D — 1000 — 1000 240D — 1000 — 1000 480D — 2000 — 2500 480D — 2500 — 2500 600D — 2500 — 2500 600D — 2500 — 2500 Table 6. 300kA Table 3. 300kA Voltage/ system code Protection mode L-N L-G N-G L-L Voltage/ system code Protection mode L-N L-G N-G L-L 1000 208Y 700 700 700 1000 208Y 600 700 600 480Y 1200 1200 1200 1800 480Y 1000 1200 1000 1800 600Y 1500 1500 1500 2500 600Y 1500 1500 1500 2500 240D — 1000 — 1000 240D — 1000 — 1000 — 1800 — 2000 — 2500 — 2500 480D — 1800 — 2000 480D 600D — 2500 — 2500 600D Table 7. 400kA Table 4. 400kA 4 Voltage/ system code Voltage/ system code L-N L-G N-G L-L 1000 208Y 600 700 600 1000 Voltage/ system code Protection mode L-N L-G N-G L-L 208Y 700 700 700 Protection mode 480Y 1200 1200 1200 1800 480Y 1000 1200 1000 1800 600Y 1500 1500 1500 2500 600Y 1500 1500 1500 2500 240D — 1000 — 1000 240D — 1000 — 1000 480D — 1800 — 2000 480D — 1800 — 2000 600D — 2500 — 2500 600D — 2500 — 2500 Eaton.com/bussmannseries BSPD SPDs for overvoltage protection on switchgear and power distribution panels Technical Data 10209 Effective December 2015 NEMA 4X: Basic (cat. nos ending with 1P) NEMA 4X: Standard or Standard w/ Surge Counter (cat. nos. ending with 2P or 3P) Table 8 120–200kA Table 11. 120–200kA Voltage/ system code Protection mode L-N L-G N-G L-L Voltage/ system code Protection mode L-N L-G N-G L-L 208Y 700 800 700 1200 208Y 900 900 700 1500 480Y 1200 1200 1000 2000 480Y 1200 1200 1000 2500 600Y 1500 1500 1500 2500 600Y 1500 1500 1500 2500 240D — 1000 — 1000 240D — 1000 — 1000 480D — 2000 — 2500 480D — 2500 — 2500 600D — 2500 — 2500 600D — 2500 — 2500 L-N L-G Table 9. 300kA Voltage/ system code Table 12. 300kA Protection mode L-N L-G N-G L-L Voltage/ system code Protection mode N-G L-L 208Y 700 800 700 1200 208Y 800 900 700 1500 480Y 1200 1200 1200 2000 480Y 1200 1200 1000 2000 600Y 1500 1500 1500 2500 600Y 1500 1500 1500 2500 240D — 1000 — 1000 240D — 1000 — 1000 480D — 1800 — 2000 480D — 2000 — 2000 600D — 2500 — 2500 600D — 2500 — 2500 Table 10. 400kA Table 13. 400kA Voltage/ system code Protection mode Voltage/ system code L-N L-G N-G L-L 208Y 700 800 700 Protection mode L-N L-G N-G L-L 1200 208Y 800 900 700 1500 480Y 1200 1200 1200 2000 480Y 1200 1200 1000 2000 600Y 1500 1500 1500 2500 600Y 1500 1500 1500 2500 240D — 1000 — 1000 240D — 1000 — 1000 480D — 1800 — 2000 480D — 2000 — 2000 600D — 2500 — 2500 600D — 2500 — 2500 Eaton.com/bussmannseries 5 Technical Data 10209 BSPD SPDs for overvoltage protection on switchgear and power distribution panels Effective December 2015 5.0 Specifications Table 14. specifications Description Specification Available system voltages Three-phase Wye 120/208, 277/480 and 347/600 Three-phase Delta 240, 480 and 600 Input power frequency 50/60Hz Maximum continuous operating voltage (MCOV) 208Y, and 240D voltage/system type codes 150 L-N,150 L-G, 150 N-G, 300 L-L 480Y Voltage/system type code 320 L-N, 320 L-G, 320 N-G, 640 L-L 600Y Voltage/system type code 420 L-N, 420 L-G, 420 N-G, 840 L-L 480D Voltage/system type code 640 L-G, 640 L-L 600D Voltage/system type code 840 L-G, 840 L-L Short-Circuit Current Rating (SCCR) 200kA Nominal discharge current (In) 20kA Surge current capacity per phase (Imax) 120kA, 200kA, 300kA and 400kA ratings available SPD Types Type 1 (Basic configuration, can also be used in Type 2 applications) Type 2 (Standard and Standard With Surge Counter configurations) Enclosure types NEMA 1, NEMA 4X 304 Stainless Steel Ports 1 SPD Conductor length/gauge 48” (1.22m) 10AWG Stranded copper Form C contact relay (Standard and standard with surge counter configurations only) Contact ratings 150Vac or 125Vdc, 1A maximum Lead length/gauge 48 inches (1.22m) / 14AWG Contact logic Power ON, normal state; N.O. contact = Open, N.C. contact = Closed Power OFF, fault state; N.O. contact = Closed, N.C. contact = Open Power consumption Basic configuration 208Y and 240D voltage/system type codes 0.5W 480Y and 480D voltage/system type codes 1.1W 600Y and 600D voltage/system type codes 1.3W Standard and Standard With Surge Counter configurations 6 208Y and 240D voltage/system type codes 0.6W 480Y, and 480D voltage/system type codes 1.7W 600Y and 600D voltage/system type codes 2.1W Protection modes Three-phase Delta; L-G, L-L Three-phase Wye; L-N, L-G, N-G, L-L Operating temperature / humidity -40 to +50°C (-40 to +122°F) / 5% to 95%, non-condensing Operating altitude - ft (m) 16,000 (5000) EMI/RFI filtering attenuation Up to 50dB from 10kHz to 100MHz (standard and standard with surge counter configurations) Weight - lbs (kg) NEMA 1: 120kA-200kA - 6.8 (3.1), 30- 400kA -13.5 (6.1) NEMA 4X: 120-200kA - 14.6 (6.6), 300-400kA - 21.0 (9.5) Agency information - Basic, Standard and Standard With Surge Counter configurations UL Listed 1449 3rd Edition File E316410 Guide VZCA, CSA Certified Notice 516 File 243397 - Standard and Standard With Surge Counter configurations are also UL Recognized 1283 5th Edition File E316410 Guide VZCA2, CSA Component Acceptance Std. C22.2 No. 8-M1986 File 243397 Seismic withstand capability Meets or exceeds the requirements specific to I.B.C. 2006, C.B.C 2007 and U.B.C zone 4 Warranty 10 Years (see warranty statement 3A1502 for details at www.cooperbussmann.com/ Surge) Eaton.com/bussmannseries BSPD SPDs for overvoltage protection on switchgear and power distribution panels Technical Data 10209 Effective December 2015 6.0 Catalog Number System Table 15. BSPD part number system All possible combinations of the BSPD attributes are available for ordering. BSPD 200 480D 2 K Enclosure rating Series BSPD K = NEMA 1 P = NEMA 4X kA Rating per phase 120kA 200kA 300kA 400kA Voltage/system type code 208Y = 120/208 Wye (4W + G) 480Y = 277/480 Wye (4W + G) 600Y = 347/600 Wye (4W + G) 240D = 240 Delta (3W + G) 480D = 480 Delta (3W + G) 600D = 600 Delta (3W + G) Configurations 1 = Basic Green and red LEDs per phase to indicate protection status Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode 2 = Standard Green and red LEDs per phase to indicate protection status Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode Audible alarm with Silence button Form C contact relay. See Table 3, Specifications EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz 3 = Standard With Surge Counter Green and red LEDs per phase to indicate protection status Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode Audible alarm with silence button Form C contact relay EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz Surge counter with reset button Technical support information If you have any questions or need additional information, please contact the Eaton’s Bussmann Division application engineers between the hours of 7:00 am and 5:00 pm central time at 855-287-7626 (855-Bussmann) or by email, [email protected]. The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries © 2015 Eaton All Rights Reserved Printed in USA Publication No. 10209 – BU-SB14678 December 2015 For Eaton’s Bussmann series product information, call 1-855-287-7626 or visit: Eaton.com/bussmannseries Eaton and Bussmann are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. UL is a registered trademark of the Underwriters Laboratories, Inc. Follow us on social media to get the latest product and support information. 7