HG4138L Miniature PCB / QC Heavy Duty Power Relay FEATURES Improved HG4138 relay by magnetic arc blowout Up to 45A switching capacity PCB + QC termination TYPICAL APPLICATIONS Power supply device Industrial control Medical equipment CONTACT RATING 45A, 240VAC 45A, 28VDC Resistive 1 Form C (1Z) NO NC 30A, 240VAC 15A, 240VAC 30A, 28VDC 15A, 28VDC 1 Form B (1D) 1 Form A (1H) Form 15A, 240VAC 15A, 28VDC UL /CSA RATING Voltage 1 Form A (1H) 1 Form B (1D) 240VAC 240VAC 28VDC 240VAC 120VAC 240VAC 120VAC 120VAC 277VAC 125 - 250VAC 45A 45A 30A 3HP 1.5HP 120A/45A 147A/33A TV8 15A 700VA 20A 20A 15A 0.75HP 0.375HP Load Type General Purpose Resistive Motor LRA /FLA Tungsten Ballast Pilot Lamp 1 Form C (1Z) NO NC 30A 15A 15A 30A 30A 15A 0.75HP 2HP 1.5HP 0.375HP 45A/15A 75A/30A 30A/10.5A TV4 4.5A TV8 15A TV4 4.5A CONTACT DATA AgCdO, AgSnOInO 50 mΩ, max. at 0.1A, 6VDC Material Initial Contact Resistance Service Life Mechanical 107 ops. Electrical 1.5 x 104 ops. COIL DATA Coil Voltage Code Nominal Voltage (VDC) Resistance (Ω) ±10% Must Operate Voltage max. (VDC) Must Release Voltage min. (VDC) 005 006 009 012 024 048 110 5 6 9 12 24 48 110 27 40 97 155 660 2560 10330 3.75 4.50 6.75 9.00 18.00 36.00 82.50 0.5 0.6 0.9 1.2 2.4 4.8 11.0 CHARACTERISTICS Operate Time Release Time Insulation Resistance Dielectric Strength Shock Resistance Vibration Resistance Power Consumption Ambient Temperature Weight 15 ms. typical 10 ms. typical 1000 MΩ, at 500VDC, 50%RH 1500 Vrms, 1 min. between open contacts 1500 Vrms, 1 min. between coil and contacts 10 g, 11ms, functional; 100 g, destructive DA 1.5mm, 10 - 55 Hz, 1W, approx. -55ºC to 85ºC operating 32 g, approx. HG4138L 1/2 HG4138L ORDERING DESIGNATION Example: HG4138L / 012 - 1Z 0 1 F Model Coil Voltage Code Contact Form 1H: 1 Form A; 1D: 1 Form B; 1Z: 1 Form C Mounting Version 0: PCB Version 1: Sealed; 2: Dust Cover Thermal Class Nil: UL Class B; F: UL Class F OVERALL DIMENSIONS, MOUNTING HOLES AND WIRING DIAGRAMS (mm) Overall Dimensions Mounting Holes (Bottom View) Wiring Diagrams (Top View) NOTES 1. 2. 3. 4. 5. All parameters, unless otherwise specified, are measured at ambient temperature 23ºC. In mounting holes drawing the * holes is not needed for 1 Form A, the ** hole is not needed for 1 Form B. To exert optimum electrical life, please remove the tape of sealed version after cleaning process. Custom-made services available with operational quantity. Please let us know your special requirements. Specifications subject to change without prior notice. DB LECTRO INC. 3600 boul. Matte suite I Brossard Qc J4Y-2Z2 TEL: (450)-444-1424 FAX: (450)-444-4714 HG4138L 2/2